On this page
ADs that cite it · 1
Newest first, with the revision each names, as OpenAirDocs read it from the AD’s text: check it against the AD.
Also cited in 1 proposed AD.
Text · 9OCR
This text is OCR from a scan. OCR can misread letters and numbers. © Bombardier Inc. Filed by the FAA in regulations.gov docket FAA-2011-1095; AD 2012-08-15 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.
Query with SQL
duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = 'b73dce369e9dee2365c29d4d0658ccdc0bfd814b8804d30f86f5d3a859291523' ORDER BY p.page"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = 'b73dce369e9dee2365c29d4d0658ccdc0bfd814b8804d30f86f5d3a859291523' ORDER BY p.page
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
ČHÄLLỀNGĚŘ 605 CUSTOMER SERVICES
SERVICE BULLETIN SUMMARY This Service Bulletin is available at:
www.cic.bombardier.com MODEL CL-600-2B16 ATA 24-50
ELECTRICAL POWER
INSPECTION/REWORK - AC ELECTRICAL LOAD DISTRIBUTION -
INSPECTION OF LOOSE AND IMPROPERLY CRIMPED TERMINAL LUG CONNECTIONS IN CBP-2, CBP-3, CBP-4, JB17 AND JB18 The information below is provided for your reference. For full details, please see corresponding paragraph contained within this bulletin.
COMPLIANCE TIME RECOMMENDED Before or at the next 800 hour check
SPECIFIED TIME COMPLIANCE EFFECTIVITY: A/C Serial No. 5701 to 5752, 5754 to 5756, 5758 to 5775, 5779, 5781, 5788, 5789, 5792, 5795, 5798, 5801 and 5804 MANPOWER: 3 man-hours KITS and/or PARTS YES NO
TOOLING/GSE YES NO PLANNING INFORMATION: See important information at the start of Paragraph 1. YES J NO
DEDICATED SCHEDULE YES NO PREREQUISITE SERVICE BULLETINS: N/A To place an order for parts or kits, please call Bombardier Parts Logistics at:
514-855-2999 or 1-866-538-1247 Basic Issue: Dec 07/2009 605-24-002 Page 1 of 1
CHALLENGER 605 OMBARDIE CUSTOMER SERVICES
SERVICE BULLETIN This Service Bulletin is available at:
www.cic.bombardier.com MODEL CL-600-2B16 ATA 24-50
ELECTRICAL POWER
INSPECTION/REWORK - AC ELECTRICAL LOAD DISTRIBUTION -
INSPECTION OF LOOSE AND IMPROPERLY CRIMPED TERMINAL LUG CONNECTIONS IN CBP-2, CBP-3, CBP-4, JB17 AND JB18
1. PLANNING INFORMATION.
A. Effectivity CL-600-2B16 aircraft, Serial No. 5701 to 5752, 5754 to 5756, 5758 to 5775, 5779, 5781, 5788, 5789, 5792, 5795, 5798, 5801 and 5804.
All other subsequent CL-600-2B16 aircraft are scheduled for the modification in production (Ref.: Restriction and/or Special Instruction, C-4040).
NOTE: The instructions given in this Service Bulletin are only applicable to the systems and parts installed at the time of delivery of the aircraft or as changed by Bombardier Aerospace Service Bulletin(s).
Before you do this bulletin, examine all STC, STA or equivalent action changes to make sure that this bulletin can be completed.
B. Reason Quality Control investigations have reported conditions affecting the wiring of Circuit Breaker Panels 2, 3 and 4 (CBP-2, CBP-3, CBP-4) and Junction Boxes JB17 and JB18. It was discovered that Foreign Object Damage (FOD) may be found in these locations. In addition, the crimping process of the nickel plated terminal lugs, size #22-20 with the green color insulating sleeve, may not have been manufactured as per applicable standards.
This Service Bulletin gives instruction to inspect for FOD in the affected areas and to replace any loose or badly crimped lugs to ensure safety, reliability and wiring integrity.
tefer to applicable govemmental agency regulations and requirements and make sure that the work described in this Service Bulletin is performed in compliance with manufacturer's recommendations and/or acceptable industry standards This document is proprietary to Bombardier Inc. and/or its affiliates and may not be reproduced or copied in any form or by any means without the prior witten consent of Bombardier Inc. and/or its affiliates.
© 2009 Bombardier Inc. All rights reserved Challenger*, Global Express*, Global Express **, Global 5000*, Learjet* are Trademarks of Bombardier Inc Basic Issue: Dec 07/2009 605-24-002 Page 1 of 8
CHALLENGER 605 MODEL CL-600-2B16 C. Description This Service Bulletin gives instructions to:
- Get access to circuit breaker panels 2, 3 and 4 (CBP-2, CBP-3, CBP-4) and junction boxes JB17 and JB18, Inspect and pull test all terminal lugs, size #22-20 with the green color insulating sleeve and replace if necessary,
• Perform a FOD inspection of the areas, and
- Do the necessary tests to make sure that the system operates correctly.
D. Compliance Recommended before or at the next 800 hour check from this Service Bulletin release date (Basic Issue).
E. Approval The technical content of this Service Bulletin has been approved under the authority of Transport Canada Civil Aviation (TCCA) Design Approval Organization (DAO) No. DAO #93-Q-02.
NOTES: 1. The technical content of this Service Bulletin is accepted by the FAA under the Canada/USA bilateral Aviation Safety Agreement.
2. The technical content of this Service Bulletin is accepted by the JAA and by EASA in accordance with established procedures.
F. Manpower NOTES: 1. The man-hours given are estimates to help you schedule the tasks given in this bulletin. The estimates are for direct labor performed by an experienced crew and do not include the time for familiarization, planning, aircraft preparation in hangar such as towing and positioning of scaffolds, removal of interior furnishings, repainting, supervision and inspection.
For more information related to the manpower estimates, refer to SB 605-00-002.
2. This Service Bulletin may require consumable materials that have specific curing times (refer to Paragraph 3). The accumulated curing time is not included in the labor estimates and should be considered for planning purposes before you schedule this Service Bulletin.
3. Labor hours are based on the fact that the modification will be done at the next scheduled maintenance task or inspection (e.g. 800 hour inspection).
3 man-hours are necessary to do this inspection/rework.
Basic Issue: Dec 07/2009 605-24-002 Page 2 of 8
CHALLENGER 605 MODEL CL-600-2B16 The labor required to do this Service Bulletin is available at no cost if:
the work is done during new aircraft warranty period, (i¡) the work is done at Bombardier Business Aviation Services (BBAS) or Authorized Service Facilities (ASF), and
(ili) this Service Bulletin is scheduled in less than 12 months from its release date (Basic Issue).
G. Material - Cost and Availability Parts may be necessary to do this inspection/rework. For material data, refer to Paragraph 3.B.
The parts are available at no cost if:
(i) ordered during new aircraft warranty period, and
(il) a no-charge purchase order is sent to Bombardier Aerospace in less than 12 months from this Service Bulletin release date (Basic Issue).
For those aircraft in new aircraft warranty at the time of this Service Bulletin distribution (Basic Issue), Smart Parts Plus does not pay for the parts at any time.
For those aircraft out of new aircraft warranty at the time of this Service Bulletin distribution, Smart Parts Plus pays for the parts for up to one year from this Service Bulletin distribution date (Basic Issue).
H. Tooling GSE REFERENCE NO. PART NO. DESCRIPTION Commercially Available Tag Rag Commercially Available Vacuum Commercially Available 69692-1 Crimper Commercially Available 69710-1 Crimper Commercially Available 22-20 Positioner Commercially Available 69732 Positioner NOTES: 1. Refer to the CL-605 Illustrated Tool and Equipment Manual to make sure that you use the correct equipment configuration.
2. Refer to the Liability Statement for acceptable GSE equivalents.
Basic Issue: Dec 07/2009 605-24-002 Page 3 of 8
CHALLENGER 605 MODEL CL-600-2B16 I. Weight and Balance No change.
J. Electrical Load Data No change.
K. References
- Bombardier Aerospace, Restriction and/or Special Instruction (RSI), C-4040, Rev. --.
- CL-605 Aircraft Maintenance Manual (AMM), Chapters 6, 24 and 31.
- CL-605 Wiring Manual (WM), Chapter 20.
L. Other Publications Affected None M. Equivalent Service Bulletin None.
2. ACCOMPLISHMENT INSTRUCTIONS NOTES: 1. All TASKs given in the procedures that follow are from the CL-605 Aircraft Maintenance Manual unless otherwise specified.
2. All references made to zones, access panels and/or doors, are from the CL-605 Aircraft Maintenance Manual, Chapter 6.
A. Aircraft Setup
(1) Obey all electrical/electronic safety precautions. Refer to TASK 24-00-00-910-801.
(2) Make sure that the BATT MASTER switch on the ELECTRICAL POWER control panel is set to the OFF position. Put a tag on the BATT MASTER switch.
(3) Disconnect the main battery. Refer to TASK 24-32-00-040-801.
(4) Disconnect the APU battery. Refer to TASK 24-32-00-040-802.
Basic Issue: Dec 07/2009 605-24-002 Page 4 of 8
CHALLENGER 605 MODEL CL-600-2B16 B. Inspection/Rework
(1) Gain access to the affected CB panels and junction boxes. Refer to Figure 1 below:
CBP-2 CBP-3 CBP-4 604-54047-1 604-54052-3 604-54053-5
TASK TASK TASK 31-18-01-000-802 31-18-01-000-803 31-18-01-000-804 31-18-01-400-802 31-18-01-400-803 31-18-01-400-804 JB18 JB17 601A51646-1 604-51649-35 or 601A51646-9
TASK TASK 24-01-17-000-801 24-01-18-000-801 24-01-17-400-801 24-01-18-400-801 Figure 1 Locations of Affected CB Panels and Junction Boxes Basic Issue: Dec 07/2009 605-24-002 Page 5 of 8
CHALLENGER 605 MODEL CL-600-2B16
(2) Inspect all green terminal lugs (Part No. B0808005-004N,-005N,-006N) within CBP-2, CBP-3, CBP-4, JB17 and JB18 by performing the following:
(a) Verify all affected terminal lugs by doing a manual pull test (light finger force) on all size #22 and #20 gauge wires located in the specified circuit panel locations.
(b) If any wire is found loose or any wire separates from the lug, the lug must be discarded and the wire tip is cut back and re-terminated with a new lug of the appropriate part number. Refer to chapter 20, Wiring Manual, Standard Practices and the Table 1 below:
Part Number Equivalent P/N Tool Positioner Remarks B0808005-004N N538-16362 69692-1 22-20 SEL #3 AWG 22 B0808005-004N N538-16362 69710-1 69732 SEL #1 AWG 20-22 B0808005-005N N538-8043 69692-1 22-20 SEL #1 AWG, #3 AWG 22 B0808005-006N 50832-1 69692-1 20-22 24 AWG + 1 FILLER B0808005-006N 69710-1 69732 SEL #1 AWG 20-22 Table 1
(c) The above procedure is repeated until all wires successfully pass the pull test.
(d) All crimped terminal lugs in these locations showing any of the following conditions must also be repaired per the same standard practices:
Cracked lug barrel, Cracked or perforated lug insulation, Asymmetrical secondary crimp, Broken wire strands, or Insufficient or partial wire insertion into lug barrel.
Basic Issue: Dec 07/2009 605-24-002 Page 6 of 8
CHALLENGER 605 DIE MODEL CL-600-2B16
(3) Verify all electrical connections involving screw and nut fasteners. Make sure that there are no loose connections and that the lugs cannot rotate on the fastener axis. Refer to Table 2 that follows for the recommended torque values:
Component Screw / Stud Size Torque Value (in Ibs) Circuit Breaker #8 - Steel 18 + 1 P/N MS24571-50 (Qty 2 per unit) (Qty 7 units on CBP-2) All other Circuit Breaker P/N's #8 - Steel 14 ÷ 1 (Qty 2 per unit) Power Diodes M5 - Steel 27 + 3 (Qty 4 units in JB17) (Qty 2 per unit) Shunts ¼ inch - Brass 35 + 5 (Qty 2 units in JB17) (Qty 2 per unit) #8 - Brass 8 + 1 (Qty 2 per unit) Contactors #10 - Steel 27 + 3 (Qty 1 unit in JB17) (Power Terminals) (Qty 2 units in JB18) #6 - Steel 10 + 1 (Coil/AUX Terminals) Table 2
(4) Do a visual inspection of the affected areas to ensure that there is no FOD.
(5) Reinstall the covers on JB17 and JB18.
(6) Close circuit breaker panels CBP-2, CBP-3 and CBP-4.
(7) Reconnect the main battery. Refer to TASK 24-32-00-440-801.
(8) Reconnect the APU battery. Refer to TASK 24-32-00-440-802.
(9) Set the BATT MASTER switch on the ELECTRICAL POWER control panel to the ON position. Remove the tag on the BATT MASTER switch.
C. Testing
(1) Connect and energize the external ac power. Refer to TASK 24-41-00-861-801.
(2) When applicable, do the system operational test, associated with the lugs) that was/were replaced.
(3) When applicable, do the operational test, of the circuit breaker panel(s), disconnected in the accomplishment instructions of Paragraph 2.
(4) Do an operational test of the Junction Box JB17.
Refer to TASK 24-01-17-710-801.
(5) Do the operational test of the Junction Box JB18.
Refer to TASK 24-01-18-710-801.
Basic Issue: Dec 07/2009 605-24-002 Page 7 of 8
B O CHALLENGER 605 MODEL CL-600-2B16 D. Close-out
(1) Remove all tools, equipment and unwanted materials from the aircraft.
(2) Ensure the side console panels 221EZ and 222EZ are closed.
E. Recording When this Service Bulletin is completed, make an entry in the aircraft log and send the attached Incorporation Notice to Bombardier Business Aircraft Customer Services (BBACS).
3. MATERIAL INFORMATION A. Kit No kits required.
B. Parts The parts that follow may be necessary to do this Service Bulletin and are available from Bombardier Aerospace Parts Logistics, Montréal:
NEW QTY ITEM USED INSTRUCTIONS - PART NO. PART NO. DISPOSITION B0808005-004N A/R Terminal Lug same Discard or 50831-1 B0808005-005N A/R Terminal Lug same Discard or 50832 B0808005-006N A/R Terminal Lug same Discard or 50832-1 NOTE: The part numbers for the items listed above are subject to change without revision to this Service Bulletin. In case of discrepancy between this list and any other list, the Illustrated Parts Catalog prevails and shall be used to determine the latest part number.
C. Material No materials required.
D. Publications No publications required.
Basic Issue: Dec 07/2009 605-24-002 Page 8 of 8