duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = '09d9913d2ade70db809f825409f77576aa8762b5e4b77d9433e8abb6ca118ae4' ORDER BY p.page"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = '09d9913d2ade70db809f825409f77576aa8762b5e4b77d9433e8abb6ca118ae4' ORDER BY p.page
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
TEMPORARY REVISION ALI−0192 REF#: 84ALI_198_R 4−28 FUEL SYSTEM LIMITATIONS The contents of this Temporary Revision have been approved by the Chief, Engineering (or designate), National Aircraft Cerification Branch, Transport Canada Civil Aviation Date 24 Apr 2018 Signed Philippe Ngassam FILING INSTRUCTIONS: This Temporary Revision (TR) replaces the TR ALI−0181. In the Maintenance Requirements Manual Part 2, remove the TR ALI−0181 from Section 4−28 Fuel System Limitations of the Maintenance Requirements Manual Part 2 and insert this new Temporary Revision in front of page 1.
Record the incorporation of this Temporary Revision on the RECORD OF TEMPORARY REVISIONS sheet at the front of the Manual.
Keep this Temporary Revision until the normal revision service puts this information into the Maintenance Requirements Manual.
DESCRIPTION: This Temporary Revision (TR) replaces the entire Section 4−28 Fuel System Limitations with the updates as follows:
Revises the task 284000−405 Description by removing the Note, task now applies to all.
Revises the task 284000−417 Description Applicability (was For non−APU lines, couplings and fittings: Post Modsum (4−126330), or Post Modsums (4−126330 and 4−126537), or Post Modsum (4−126336). For APU lines, couplings and fittings (Modsum 4−302000): Post Modsums (4−901425 or 4−901423), is now applicable to all).
New task 284000−419 is added.
Replaced TR ALI−0181 was issued previously to Section 4−28 to update task 284000−406. Revised Applicability (was (Post Modsum 4−113299) or (Post Modsum 4−121195) or (Post Modsum 4−110139) or (Post Modsum 4−113977) or (Post Modsum 4−113978) or (Post Modsum 4−124440), is now applicable to all).
Replaced TR ALI−0179 was issued previously to Section 4−28 to update task 284000−406. Revised Applicability (was (Post Modsum 4−113299) or (Post Modsum 4−121195) or (Post Modsum 4−110139)), (is now (Post Modsum 4−113299) or (Post Modsum 4−121195) or (Post Modsum 4−110139) or (Post Modsum 4−113977) or (Post Modsum 4−113978) or (Post Modsum 4−124440)).
E
AIRWORTHINESS LIMITATIONS PSM 1−84−7 − Maintenance Requirements Manual − Part 2 EFFECTIVITY: DHC−8−400 Series
4−28 TR ALI−0192 Page 1 of 4 Apr 24/2018
TEMPORARY
REVISION
TEMPORARY
REVISION
FUEL SYSTEM LIMITATIONS 28 − FUEL SYSTEM LIMITATIONS
ALI TASK NUMBER CONF LTR MODEL
EFFECTIVITY
DESCRIPTION INTERVAL TASK TYPE 284000−401 ALL FUEL QUANTITY GAUGING: Detailed Inspection of the Metal Overall Shield on the Fuel Quantity Gauging System DET18000 FH or 108 MO 284000−402 ALL FUEL QUANTITY GAUGING: Detailed Inspection of the Fuel Probe Harness Inside the Fuel Tank APPLICABILITY: (Post Modsum 4−126370) or (Post Modsum 4−126336) DET18000 FH or 108 MO 284000−403 ALL FUEL QUANTITY GAUGING: Detailed Inspection of the Low Level Float Switch Harness Inside the Fuel Tank APPLICABILITY: (Post Modsum 4−126370) or (Post Modsum 4−126336) DET18000 FH or 108 MO 284000−404 ALL FUEL QUANTITY GAUGING: Detailed Inspection of the High Level Sensor Harness Inside the Fuel Tank APPLICABILITY: (Post Modsum 4−126370) or (Post Modsum 4−126336) DET18000 FH or 108 MO 284000−405 ALL FUEL STORAGE: Detailed Inspection of the Self Bonding Couplings Inside the Fuel Tank DET18000 FH or 108 MO 284000−406 ALL FUEL STORAGE: Detailed Inspection of the Teflon Sleeve on the Fuel Tank Vent Line DET18000 FH or 108 MO 284000−407 ALL FUEL STORAGE: Detailed Inspection of the Sealant Around the Anchor Nuts at Access Panels, Sta. YW 42.000 to YW 191.200 DET18000 FH or 108 MO E
AIRWORTHINESS LIMITATIONS PSM 1−84−7 − Maintenance Requirements Manual − Part 2 EFFECTIVITY: DHC−8−400 Series
4−28 TR ALI−0192 Page 2 of 4 Apr 24/2018
TEMPORARY
REVISION
TEMPORARY
REVISION
FUEL SYSTEM LIMITATIONS 28 − FUEL SYSTEM LIMITATIONS
ALI TASK NUMBER CONF LTR MODEL
EFFECTIVITY
DESCRIPTION INTERVAL TASK TYPE 284000−408 ALL FUEL STORAGE: Detailed Inspection of the Access Panel to Wing Skin Mating Surfaces and Access Panel Gasket, Sta. YW 191.200 to YW 425.019 DET18000 FH or 108 MO 284000−409 ALL FUEL STORAGE: Detailed Inspection of the Dome Nut on the Fuel Tank Water Drain Valve DET18000 FH or 108 MO 284000−410 ALL FUEL STORAGE: Detailed Inspection of the Sealant on the Vent Line Support Bracket and Attachment Hardware, Sta. YW 42.000 APPLICABILITY: (Post Modsum 4−126330) or (Post Modsum 4−122242) DET18000 FH or 108 MO 284000−411 ALL FUEL QUANTITY GAUGING: Functional Check of the Fuel Quantity Metal Overall Shield for Electrical Bonding FNC18000 FH or 108 MO 284000−412 ALL FUEL STORAGE: Functional Check of the Fuel Tank Water Drain Valve for Electrical Bonding FNC18000 FH or 108 MO 284000−413 ALL FUEL STORAGE: Functional Check of the Magnetic Dipstick for Electrical Bonding FNC18000 FH or 108 MO 284000−414 ALL FUEL STORAGE: Operational Check of the Low Level Float Switch OPC18000 FH or 108 MO E
AIRWORTHINESS LIMITATIONS PSM 1−84−7 − Maintenance Requirements Manual − Part 2 EFFECTIVITY: DHC−8−400 Series
4−28 TR ALI−0192 Page 3 of 4 Apr 24/2018
TEMPORARY
REVISION
TEMPORARY
REVISION
FUEL SYSTEM LIMITATIONS 28 − FUEL SYSTEM LIMITATIONS
ALI TASK NUMBER CONF LTR MODEL
EFFECTIVITY
DESCRIPTION INTERVAL TASK TYPE 284000−415 ALL FUEL STORAGE: Functional Check of the Auxiliary Boost Pump for Electrical Bonding FNC18000 FH or 108 MO 284000−416 ALL FUEL STORAGE: Functional Check of the High Level Sensor for Electrical Bonding FNC18000 FH or 108 MO 284000−417 ALL FUEL STORAGE: Functional Check of the Fuel Tank Components and Plumbing Lines for Electrical Bonding FNC18000 FH or 108 MO 284000−418 ALL FUEL STORAGE: Detailed Inspection of the Teflon Sleeve on the Fuel Tank Lines and Clearances Between Fuel Lines and Structure APPLICABILITY: (Post Modsum 4−113643 and Post Modsum 4−113754) or (Post Modsum 4−113643 and Post Modsum 4−113745 and Post Modsum 4−113754) or (Post Modsum 4−113762) DET18000 FH or 108 MO 284000−419 ALL Detailed Inspection of the Fuel Tank Plumbing Lines Isolator Assemblies APPLICABILITY: Post Modsum 4−113969 or Post Modsum 4−113970 DET18000 FH or 108 MO E
AIRWORTHINESS LIMITATIONS PSM 1−84−7 − Maintenance Requirements Manual − Part 2 EFFECTIVITY: DHC−8−400 Series
4−28 TR ALI−0192 Page 4 of 4 Apr 24/2018