NONDESTRUCTIVE TESTING MANUAL Part 4 - Ultrasonic Part 4 Part 5 Part 6 Part 7 Part 8 Part 9 Page 1 53- 61- 110 EFFECTIVITY: SEE PARAGRAPH 2 TR 53- TEMPORARY REVISION 53- FILING INSTRUCTIONS: Insert this Temporary Revision facing TASK Part 4, 53- 61- 110.

Record the incorporation of this Temporary Revision on the yellow RECORD OF TEMPORARY REVISIONS sheet at the front of this volume.

Keep this Temporary Revision until Revision 45 incorporates this information into the Nondestructive Testing Manual.

DESCRIPTION: This Temporary Revision revises TASK Part 4, 53- 61- 110 SPECIAL

DETAILED INSPECTION OF THE ENGINE SUPPORT BEAM UPPER AND LOWER CAP ANGLES AT FS625.3 AND FS640.0 BETWEEN LBL36.2 AND RBL36.2 to introduce a new calibration reference standard (CRS) and make other miscellaneous changes.

Part 4 of 10 130 130 Sep 15/23

NONDESTRUCTIVE TESTING MANUAL Part 4 − Ultrasonic Part 4 53−61−110 EFFECTIVITY: SEE PARAGRAPH 2

SPECIAL DETAILED INSPECTION OF THE ENGINE SUPPORT BEAM UPPER AND LOWER CAP ANGLES AT FS625.3 AND FS640.0, BETWEEN LBL36.2 AND RBL36.2

1. General A. Function

(1) This inspection procedure is used to detect subsurface cracks propagating from the fasteners holes in the top and bottom webs, 601−35006−3 and 601−35006−5 respectively, of the engine support beam covered by the transversal angles, along WL119.12 and WL111.

09 between LBL38.00 and RBL38.00 at FS625.30.

NOTE: This subsurface inspection is to be done at the same time as the eddy current inspection (Refer to Part 6, 53−61−110).

This inspection procedure applies to both sides of the aircraft.

B. Reference Information

(1) For added data that is necessary to do this inspection, refer to the manuals that follow:

− Nondestructive Test Manual (NDTM) Part 1−General Information − Structural Repair Manual (SRM) − Aircraft Maintenance Manual (AMM).

certified to an NDT Standard approved by the National Airworthiness Authority.

C. Location

(1) The area is in Zone 311/312 (Refer to NDTM Part 1, 51−01−03).

D. Access

(1) Access to the engine support beam is from the aft−equipment compartment door 311BB.

E. Parts Examined in this Procedure Refer to Table 1.

Table 1 − Part Identification Data ITEM NO. [1] DESCRIPTION DRAWING OR PARTNUMBER [2] MATERIAL SPECIFICATION 1 Top web 601−35006−3 7075−T62 QQ−A−250/132 Bottom web 601−35006−5 7075−T62 QQ−A−250/13 NOTE [1]: Parts that do not include an item number are not identified in Figure 3.

NOTE [2]: Numbers that do not include a dashed suffix are drawing numbers.

2. Effectivity A. All aircraft Pre−SB 601R−53−059 Rev A or later, or (Pre−SB 601R−53−065 and Pre−SB 601−53−068).

NOTE: Part 6, 53−61−110 must be accomplished in order to complete the full inspection.

TR 53-

(2) This inspection must be done by a Level II or Level III ultrasonic quali-fied individual AWL 53-61-110 Page 2of 10 130 Sep 15/23

NONDESTRUCTIVE TESTING MANUAL Part 4 − Ultrasonic Part 4 53−61−110 EFFECTIVITY: SEE PARAGRAPH 2

3. Tools and Equipment A. Use the items identified as follows, or their equivalent (Refer to NDTM Part 1, 51−20−04):

NOTE: Equivalent ultrasonic equipment may be used provided that it satisfies the requirements of this procedure and is capable of resolving the reference notch in the calibration reference standard at the required level of resolution.

− Ultrasonic Flaw Detector, Sonatest Model: UFDS − Miniature angle−beam transducer, 45 degrees in Al, 0.25 X 0.375 in. (6.35 X 9.52 mm), 5 MHz frequency, Model: VM 7−121−TC−A − Coaxial cable (BNC to microdot) − Gorptech industrial ultrasonic couplant gel supplied by Inspectech Ltd − MHI RJ Aviation calibration reference standard No. EXCM601R30039, similar and cross section as the inspection area containing electrical discharge machined (EDM) notches − High intensity light source.

4. Preparation and Cleaning A. Prepare the inspection area as follows:

(1) Identify the location of the area to be inspected.

WARNING: MAKE SURE THAT THERE IS A GOOD FLOW OF CLEAN AIR AND SUFFICIENT FIRE PROTECTION. USE APPROVED BODY PROTECTION WHEN YOU USE SOLVENTS. ALL SOLVENTS ARE POISONOUS AND SOME ARE FLAMMABLE.

(2) Open the aft−equipment compartment door to get access to the engine support beam (Refer to Part 1, 51−01−04).

(3) Clean the inspection surfaces (Refer to the SRM, 51−26−00).

NOTE: It is not necessary to remove the finish from the parts unless it shows deterioration or local damage.

(4) If the finish in the area to be inspected is damaged or deteriorated, remove the finish (Refer to the SRM, chapter 51).

5. Inspection for Subsurface Cracks Initiating from the Most Forward Row of Fasteners in the

0.032−in. (0.81 mm) Thick Section of the Top and Bottom Webs at FS625.30, at BL0.00 and BL4.00, along WL119.12 and WL111.09 A. Equipment Calibration Refer to Figure 1 and Figure 2.

(1) Connect the microminiature angle−beam transducer VM 7−121−TC−A to the ultrasonic instrument using the coaxial cable.

(2) Turn the power ON and set the instrument to pulse−echo test mode and 5 MHz test frequency.

TR 53- of 10Page 3 130 Sep 15/23

NONDESTRUCTIVE TESTING MANUAL Part 4 − Ultrasonic Part 4 53−61−110 EFFECTIVITY: SEE PARAGRAPH 2 rnd5361110_003.dg, jp/gg, 11/09/00

0.62 in.

(15.75 mm)

0.62 in.

(15.75 mm) NOTE Letters A through D are EDM notches.

TRANSDUCER PLACEMENT 1

TRANSDUCER PLACEMENT 2 A B D C

TRANSDUCER PLACEMENT 3

TRANSDUCER PLACEMENT 4 −4 ANGLE −3 WEB CALIBRATION REFERENCE STANDARD EXCM601R 30039

AND TRANSDUCER PLACEMENTS

CHEM MILL LINE (REF)

1.00 in.

(25.4 cm)

0.032 in.

(0.81 mm)

0.050 in.

(1.27 mm)

0.25 in.

(6.35 mm) −4 ANGLE −5 ANGLE −3 WEB (FOUR PLACES) Calibration Reference Standard − Calibration and Inspection Figure 1

TR 53- of 10Page 4 130 Sep 15/23

NONDESTRUCTIVE TESTING MANUAL Part 4 − Ultrasonic Part 4 53−61−110 EFFECTIVITY: SEE PARAGRAPH 2 rnd5361110_004.dg, gg/jp, 01/11/00 NEB NEA IP

CRT DISPLAY IP EFH IP NEC TRANSDUCER PLACEMENT 3 50 1000 TRANSDUCER PLACEMENT 4 TRANSDUCER PLACEMENT 1 TRANSDUCER PLACEMENT 2 50 100 50 10050 1000 0 0 IP NED NOTES 50 100 50 100 50 100SIGNAL AMPLITUDE 50 100

SIGNAL AMPLITUDE SIGNAL AMPLITUDE

SIGNAL AMPLITUDE IP = Initial pulse.

EFH = echo from hole.

NEA = Echo from notch A.

NEB = Echo from notch B.

NEC = Echo from notch C.

NED = Echo from notch D.

CRT DISPLAY

CRT DISPLAY CRT DISPLAY EFH CRT Displays − Calibration and Indications Figure 2

TR 53- of 10Page 5 130 Sep 15/23

NONDESTRUCTIVE TESTING MANUAL Part 4 − Ultrasonic Part 4 53−61−110 EFFECTIVITY: SEE PARAGRAPH 2

(3) Apply an even layer of couplant gel on the 0.032−in. (0.81 mm) thick section of −3 web adjacent to the −4 and −5 angles (0.62 in. (15.75 mm) edge distance side) of the calibration reference standard EXCM601R30039, as shown in Figure 1.

(4) Do the instrument calibration on the calibration reference standard as follows:

(a) Position the front of the transducer against the −4 angle so that the sound beam is directed at EDM notch A, see Transducer Placement 1, Figure 1. Swivel the transducer to obtain a maximized reflection signal from EDM notch A.

(b) Adjust the instrument (GAIN) control to obtain a 100% full screen height (FSH) signal from EDM notch A.

(c) Use the instrument (DELAY) and (RANGE) controls to set the leading edge of the reflection signal from EDM notch A at 20% of the horizontal limit on the baseline.

B. Inspection Procedure Refer to Figure 2 and Figure 3.

(1) After equipment calibration as outlined in Paragraph 5.A., apply an even layer of couplant gel on the 0.32−in. (0.81 mm) thick sections of the top and bottom webs, 601−35006−3 and 601−35006−5 respectively, forward corner at BL0.00 and BL4.00 adjacent to the edge of the transversal angles (with the vertical flange) at FS625.30. The couplant gel must cover approximately 0.50 in. (12.70 mm) each side of the most forward row of fasteners.

(2) Position the transducer on the top web 601−35006−3 forward corner with its front against the transversal angle (the side with the vertical flange) at BL0.00. Scan both sides of the fastener with a slight swivel movement and use the edge of the transversal angle as a guide.

(3) Repeat Paragraph 5.B.(2) at BL4.00.

(4) Repeat Paragraph 5.B.(2) and 5.B.(3) for the bottom web 601−35006−5.

C. Acceptance or Rejection Criteria

(1) Any distinct indications with an amplitude signal of 50% FSH or greater is classified as a crack and cause for rejection.

(2) Record and report results in accordance with company guidelines and policies.

(3) For indications that exceed the allowable limits, it is recommended that you contact MHIRJ Customer Support (refer to SRM 51−13−01).

TR 53- of 10Page 6 130 Sep 15/23

NONDESTRUCTIVE TESTING MANUAL Part 4 − Ultrasonic Part 4 53−61−110 EFFECTIVITY: SEE PARAGRAPH 2 FS 625.30 BL 0.00 LBL 38.00 WL 119.12 WL 111.09 FS 625.30 rnd5361110_005.dg, gg, 14/09/00 RBL 38.00 NOTE 1 Examine the shaded area.

A B B A −B B 1

TRANSVERSAL WL 119.12 WL 111.09 FS 625.30

TRANSVERSAL (19 PLACES) (19 PLACES) LBL 36.20 LBL 27.50 LBL 18.00 LBL 4.00 RBL 18.00 RBL 4.00 RBL 9.50 RBL 27.50 RBL 36.20 LBL 9.50 (19 PLACES) FS 640.00 (TYPICAL)

TOP WEB 1 2ND FORWARD

FASTENER 2ND FORWARD

FASTENER

MOST FORWARD

FASTENER Inspection of the Engine Support Beam at FS625.30 Between RBL38.00 and LBL38.00 − Location and Inspection Figure 3

TR 53- of 10Page 7 130 Sep 15/23

NONDESTRUCTIVE TESTING MANUAL Part 4 − Ultrasonic Part 4 53−61−110 EFFECTIVITY: SEE PARAGRAPH 2

6. Inspection for Subsurface Cracks Initiating from the Second Forward Row of Fasteners in the

0.032−in. (0.81 mm) Thick Section of the Top and Bottom Webs at FS625.30, at BL0.00 and BL4.00, along WL119.12 and WL111.09 A. Equipment Calibration Refer to Figure 1 and Figure 2.

(1) Do the instrument calibration on the calibration reference standard as follows:

(a) Position the front of the transducer against the −4 angle so that the sound beam is directed at EDM notch B, see Transducer Placement 2, Figure 1. Swivel the transducer to obtain a maximized reflection signal from EDM notch B.

(b) Adjust the instrument (GAIN) control to obtain a 100% full screen height (FSH) signal from EDM notch B.

(c) Use the instrument (DELAY) and (RANGE) controls to set the leading edge of the reflection signal from EDM notch B at 20% of the horizontal limit on the baseline.

B. Inspection Procedure Refer to Figure 2 and Figure 3.

(1) After equipment calibration as outlined in Paragraph 6.A., apply an even layer of couplant gel on the 0.32−in. (0.81 mm) thick sections of the top and bottom webs, 601−35006−3 and 601−35006−5 respectively, forward corner at BL0.00 and BL4.00 adjacent to the edge of the transversal angles (with the vertical flange) at FS625.30. The couplant gel must cover approximately 0.50 in. (12.70 mm) each side of the second forward row of fasteners.

(2) Position the transducer on the top web 601−35006−3 aft corner with its front against the transversal angle (the side with the vertical flange) at BL0.00. Scan both sides of the fastener with a slight swivel movement and use the edge of the transversal angle as a guide.

(3) Repeat Paragraph 6.B.(2) at BL4.00.

(4) Repeat Paragraph 6.B.(2) and 6.B.(3) for the bottom web 601−35006−5.

C. Acceptance or Rejection Criteria

(1) Any distinct indications with an amplitude signal of 50% FSH or greater is classified as a crack and cause for rejection.

(2) Record and report results in accordance with company guidelines and policies.

(3) For indications that exceed the allowable limits, it is recommended that you contact MHIRJ Customer Support (refer to SRM 51−13−01).

7. Inspection for Subsurface Cracks Initiating from the Most Forward Row of Fasteners in the

0.05−in. (1.27 mm) Thick Section of the Top and Bottom Webs at FS625.30, Between BL9.50 and BL38.00, along WL119.12 and WL111.09 A. Equipment Calibration Refer to Figure 1 and Figure 2.

TR 53- of 10Page 8 130 Sep 15/23

NONDESTRUCTIVE TESTING MANUAL Part 4 − Ultrasonic Part 4 53−61−110 EFFECTIVITY: SEE PARAGRAPH 2

(1) Apply a thick even layer of couplant gel on the 0.05−in. (1.27 mm) thick section of the −3 web adjacent to the −4 and −5 angles (0.62 in. (15.75 mm) edge distance side) of the calibration reference standard EXCM601R30039, as shown in Figure 1 .

(2) Do the instrument calibration on the calibration reference standard as follows:

(a) Position the front of the transducer against the −4 angle so that the sound beam is directed at EDM notch C, see Transducer Placement 3, Figure 1.

Swivel the transducer to obtain a maximized reflection signal from EDM notch C.

(b) Adjust the instrument (GAIN) control to obtain a 100% full screen height (FSH) signal from EDM notch C.

(c) Use the instrument (DELAY) and (RANGE) controls to set the leading edge of the reflection signal from EDM notch C at 20% of the horizontal limit on the baseline.

B. Inspection Procedure Refer to Figure 3.

(1) After equipment calibration as outlined in Paragraph 7.A., apply an even layer of couplant gel on the 0.05−in. (1.27 mm) thick section of the top and bottom webs, 601−35006−3 and 601−35006−5 respectively, forward corner between BL9.50 and BL38.00 adjacent to the edge of the transversal angles (with the vertical flange) at FS625.30. The couplant gel must cover approximately 0.50 in. (12.70 mm) each side of the most aft row of fasteners.

(2) Position the transducer on the top web 601−35006−3 forward corner with its front against the transversal angle (the side with the vertical flange) at BL9.50. Scan both sides of the fastener with a slight swivel movement and use the edge of the transversal angle as a guide.

(3) Repeat Paragraph 7.B.(2) between BL9.50 and BL38.00.

(4) Repeat Paragraph 7.B.(2) and 7.B.(3) for the bottom web 601−35006−5.

C. Acceptance or Rejection Criteria

(1) Any distinct indications with an amplitude signal of 50% FSH or greater is classified as a crack and cause for rejection.

(2) Record and report results in accordance with company guidelines and policies.

(3) For indications that exceed the allowable limits, it is recommended that you contact MHIRJ Customer Support (refer to SRM 51−13−01).

8. Inspection for Subsurface Cracks Initiating from the Second Forward Row of Fasteners in the

0.05−in. (1.27 mm) Thick Sections of the Top and Bottom Webs at FS625.30, Between BL9.50 and BL38 .00, along WL119.12 and WL111.09 A. Equipment Calibration Refer to Figure 1 and Figure 2.

(1) Apply an even layer of couplant gel on the 0.05−in. (1.27 mm) thick section of the −3 web adjacent to the −4 and −5 angles (0.62 in. (15.75 mm) edge distance side) of the calibration reference standard EXCM601R30039, as shown in Figure 1.

TR 53- of 10Page 9 130 Sep 15/23

NONDESTRUCTIVE TESTING MANUAL Part 4 − Ultrasonic Part 4 53−61−110 EFFECTIVITY: SEE PARAGRAPH 2

(2) Do the instrument calibration on the calibration reference standard as follows:

(a) Position the front of the transducer against the −4 angle so that the sound beam is directed at EDM notch D, see Transducer Placement 4, Figure 1. Swivel the transducer to obtain a maximized reflection signal from EDM notch D.

(b) Adjust the instrument (GAIN) control to obtain a 100% full screen height (FSH) signal from EDM notch D.

(c) Use the instrument (DELAY) and (RANGE) controls to set the leading edge of the reflection signal from EDM notch D at 20% of the horizontal limit on the baseline.

B. Inspection Procedure Refer to Figure 3.

(1) After equipment calibration as outlined in Paragraph 8.A., apply an even layer of couplant gel on the 0.05−in. (1.27 mm) thick section of the top and bottom webs, 601−35006−3 and 601−35006−5 respectively, forward corner between BL9.50 and BL38.00 adjacent to the edge of the transversal angles (with the vertical flange) at FS625.30. The couplant gel must cover approximately 0.50 in. (12.70 mm) each side of the second forward row of fasteners.

(2) Position the transducer on the top web 601−35006−3 forward corner with its front against the transversal angle (the side with the vertical flange) at BL9.50. Scan both sides of the fastener with a slight swivel movement and use the edge of the transversal angle as a guide.

(3) Repeat Paragraph 8.B.(2) between BL9.50 and BL38.00.

(4) Repeat Paragraph 8.B.(2) and 8.B.(3) for the bottom web 601−35006−5.

C. Acceptance or Rejection Criteria

(1) Any distinct indications with an amplitude signal of 50% FSH or greater is classified as a crack and cause for rejection.

(2) Record and report results in accordance with company guidelines and policies.

(3) For indications that exceed the allowable limits, it is recommended that you contact MHIRJ Customer Support (refer to SRM 51−13−01).

9. Close Out A. Remove the couplant gel from the inspection surfaces.

B. Make sure that NDTM Part 6, 53−61−110 has been completed.

C. If the finish in the inspection area was removed, replace the finish (Refer to the SRM, Chapter 51).

D. Remove all tools, equipment and unwanted materials from the work area.

E. Close the aft−equipment compartment door (Refer to Part 1, 51−01−04).

TR 53- of 10Page 10 130 Sep 15/23