On this page
ADs that cite it · 2
Newest first, with the revision each names, as OpenAirDocs read it from the AD’s text: check it against the AD.
Also cited in 2 proposed ADs.
Text · 12OCR
This text is OCR from a scan. OCR can misread letters and numbers. © Grimes Aerospace. Filed by the FAA in regulations.gov docket FAA-2017-0906; AD 2018-07-21 incorporates this document by reference. Not covered by OpenAirDocs’ CC0 dedication.
Query with SQL
duckdb -csv -c "SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = 'd97a04092eb67a6f05315a585389ca140723c55ca4bc1e69e992d7e07ec3fa14' ORDER BY p.page"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT p.page, p.text_source, p.text, f.rights_holder, f.license FROM 'https://openairdocs.org/data/latest/service_document_file_page.parquet' p JOIN 'https://openairdocs.org/data/latest/service_document_file.parquet' f USING (file_sha256) WHERE p.file_sha256 = 'd97a04092eb67a6f05315a585389ca140723c55ca4bc1e69e992d7e07ec3fa14' ORDER BY p.page
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
GRIMES SERVICE
AEROSPACE
BULLETIN
PASSENGER SERVICE UNIT GRIMES PART NUMBER 10-1571-(SERIES) FOKKER 100
PLANNING INFORMATION
a. EFFECTIVITY This service bulletin describes the procedures to modify the 10-1571-(SERIES) Passenger Service Unit (PSU), to prevent moisture from contributing to electrical shorting and or failure of the PSU. These recommended changes will be incorporated into new production PSU with serial number 1000 and subsequent.
b. REASON Excessive moisture may cause shorting of the connectors J1 or J2 and terminals of transformers T1, 12 or T3.
C. DESCRIPTION Incorporation of this service bulletin and associated kit, will insulate these components from moisture that could result in electrical shorting and failure of the PSU. After incorporation of this Service Bulletin the change will be identified with revision "C".
a. COMPLIANCE Incorporation of this service bulletin is recommended, specifically in known locations where heavy moisture / condensation has been reported, around or near the PSU.
e. APPROVAL This service bulletin contains no modification information that revises the approved configuration and therefore does not require government or other regulatory agency approval.
DATE 10/15/93 TITLE: PASSENGER SERVICE UNIT 10-1571-33-0041 REV. DATE __ _ FIGURE NO.. PAGE NO. 1 ~ 12
GRIMES SERVICE
AEROSPACE
BULLETIN
PASSENGER SERVICE UNIT GRIMES PART NUMBER 10-1571-(SERIES) FOKKER 100
PLANNING INFORMATION---(CONTINUED)
MANPOWER The estimated manhours required to accomplish the modifications contained in this service bulletin are as follows:
Disassembly 0.05 hours Modification 0.33 hours Assembly 0.10 hours Test 0.10 hours Total 0.58 hours
g. MATERIAL, COST AND AVAILABILITY Grimes Modification Kit 10-1624-1 may be procured from :
Grimes Aerospace Company Product Support Group 240 Twain Avenue Urbana, OH 43078 USA Telephone: 513-653-5225 Fax: 513-652-2322 SITA: DAYFLCR The price of Grimes Modification Kit 10-1624-1 is $ 5.45 for all orders shipped on or before 12/31/93. After this date the price is subject to change.
DATE 10/15/93 TITLE: PASSENGER SERVICE UNIT 10-1571-33-0041 REV. _ DATE _ FIGURE NO. PAGE NO. _ 2
GRIMES AEROSPACE SERVICE
BULLETIN
PASSENGER SERVICE UNIT GRIMES PART NUMBER 10-1571-(SERIES) FOKKER 100
PLANNING INFORMATION---(CONTINUED) MATERIAL, COST AND AVAILABILITY-.-(CONTINUED) The following additional customer furnished materials or EQUIVALENT are required to incorporate these changes.
(1) ADHESIVE / SEALANT, SILICONE RUBBER SEALANT, NO. 3145 Dow Corning Corp, Midland Michigan.
n. TOOLING - Not Applicable
i. WEIGHT AND BALANCE - None ELECTRICAL LOAD DATA - Not Affected SOFTWARE ACCOMPLISHMENT SUMMARY - Not Applicable
REFERENCES GRIMES DRAWING 10-1571, REV C, PASSENGER SERVICE UNIT GRIMES DRAWING 10-1624, KIT, MODIFICATION COMPONENT MAINTENANCE MANUAL 33-20-64
m. OTHER PUBLICATIONS AFFECTED None
n. FAMILY TREE CHARTS OF MODIFICATION RELATIONSHIPS Not Applicable DATE 10/15/93 TITLE: PASSENGER SERVICE UNIT 10-1571-33-0041 REV. _ _ DATE _ _ FIGURE NO. _ PAGE NO.3
GRIMES SERVICE
AEROSPACE
BULLETIN
PASSENGER SERVICE UNIT GRIMES PART NUMBER 10-1571-(SERIES) FOKKER 100 ACCOMPLISHMENT INSTRUCTIONS---(See Figure 1)
CAUTION
PLEASE USE ELECTRO-STATIC DEVICE (ESD) PRECAUTIONS
1. DISASSEMBLY NOTE: Place a soft cloth on the bench before proceeding with disassembly.
Position the LENS side of the PSU face down on the cloth, to protect the lens side of PSU from damage.
A. (Fig. 1) Unplug connector J2 of lead wire assembly (110) from the mating connector of access cover assembly (60). Loosen four (captive), ¼ turn fasteners, to "partially" free the access cover assembly from the mounting plate assembly (280).
CAUTION:
Use care with the handling of access cover assembly as it will still be attached electrically to mounting plate assembly by way of electrical wires to the circuit card assembly (CCA) and mounting plate assembly.
B. (Fig. 1) Disconnect connector J3 of lead wire assembly (185), from the (Fig. 2) mating connector (75) J3 on (Fig. 1) CCA (45A).
C. (Fig. 1) Remove six screw assemblies (55) holding CCA (45A) to access cover assembly (60).
D. Remove CCA (45A) from access cover assembly (60).
DATE 10/15/93 TITLE: PASSENGER SERVICE UNIT 10-1571-33-0041 REV. DATE __ FIGURE NO. PAGE NO. 4
GRIMES AEROSPACE SERVICE
BULLETIN
PASSENGER SERVICE UNIT GRIMES PART NUMBER 10-1571-(SERIES) FOKKER 100
ACCOMPLISHMENT INSTRUCTIONS---(CONTINUED)
2. MODIFICATION... (See Figure 2 and 3) NOTE:
Use extreme care in all handling and modification procedures, to avoid damage to any electrical component.
A. (Fig. 2) Examine the board-mounted mating connectors J1 and J2 of CCA (45A), for foreign objects and or broken / bent pins inside connector.
Clean CCA and replace connector it necessary.
B. (Fig. 3) Remove from the Kit, gaskets (65A) and (70A).
C. (Fig. 3) Install gasket (65A), inside connector (J1), carefully compressing the gasket over the pins, so that both halves of each pin are visible after installation of gasket. Repeat this identical procedure for gasket (70A), installing gasket (70A) inside connector (J2).
CAUTION Area should be well ventilated before applying adhesive / sealant.
D. (Figs. 2 and 3) Using a syringe (or similar application device), apply silicone rubber adhesive / sealant over the pins of transformers (115) T1, T2, and T3, per Figure 3.
DATE 10/15/93 TITLE: PASSENGER SERVICE UNIT 10-1571-33-0041 REV. DATE _ FIGURE NO. PAGE NO.
GRIMES AEROSPACE SERVICE
BULLETIN
PASSENGER SERVICE UNIT GRIMES PART NUMBER 10-1571-(SERIES) FOKKER 100
ACCOMPLISHMENT INSTRUCTIONS---(CONTINUED)
2. MODIFICATION... (CONTINUED) (See Figure 2 and 3) Apply sealant to form a radius, approximately 0.063 inches
(1.6 mm), along bottom edges of connectors J1 and J2.
NOTE: This material cures in any position but should not be disturbed after 5 - 10 minutes of application. Allow 24 hours for full cure.
ASSEMBLY---(See Figure 1) A. (Fig. 1) Carefully position CCA (45A) in access cover assembly (60) and secure CCA with six screw assemblies (55).
B. Install connector (185) of lead wire assembly to the mating connector J3 on the CCA. Carefully position access cover assembly (60) in place and then secure access cover assembly using the four (captive), ¼ turn fasteners.
C. Install connector of lead wire assembly (110) to mating connector J2 of access cover assembly (60).
D. Stamp or mark, with permanent ink, "REV C" and "MODIFIED PER SB10-1571-33-0041" on the access cover assembly (60).
DATE 10/15/93 TITLE: PASSENGER SERVICE UNIT 10-1571-33-0041 REV. DATE _ FIGURE NO. PAGE NO.
GRIMES SERVICE
AEROSPACE
BULLETIN
PASSENGER SERVICE UNIT GRIMES PART NUMBER 10-1571-(SERIES) FOKKER 100
ACCOMPLISHMENT INSTRUCTIONS---(CONTINUED)
4. TESTING---(See Figure 4) NOTE: For the following tests, DC ground should be connected to earth ground for maximum touch switch sensitivity.
A. Apply + 28 volts to pin 1 of connector J1 and ground pin 9.
B. The three lamps in "NO SMOKING" sign shall illuminate.
C. Remove the ground lead from pin 9 and connect it to pin 12.
D. The three lamps in "Fasten Seat Belt" sign shall illuminate.
E. Apply 115 VAC, 400 Hz, between pins 2 and 3 of connector J1 and + 28 VDC to pin 1 and DC ground to pin 4.
F. Sequentially touch the reading light touch plates. The two or three reading lights, as applicable, shall illuminate.
G. Touch the call touch plate. The attendant call light shall illuminate.
With an oscilloscope connected to pin 5, a momentary chime signal shall be present.
DATE 10/15/93 TITLE: PASSENGER SERVICE UNIT 10-1571-33-0041 REV. _ DATE FIGURE NO. PAGE NO.
GRIMES SERVICE
AEROSPACE
BULLETIN
PASSENGER SERVICE UNIT GRIMES PART NUMBER 10-1571-(SERIES) FOKKER 100
ACCOMPLISHMENT INSTRUCTIONS---(CONTINUED)
4. TESTING---(CONTINUED) (See Figure 4) H. Momentarily apply ground (use DC ground) to J1-pin 7. All reading lights shall illuminate. Repeat this step to turn off lights.
. Test complete. Disconnect 115 VAC, 400 HZ from pins 2 and 3 of connector J1 and + 28 VDC from pin 1 and DC ground from pin 4.
MATERIAL INFORMATION
FIG ITEM NEW QTY PRICE KEY WORD OLD INSTRUCTIONS NO. NO. PART NUMBER PART NUMBER DISPOSITION 20 NONE N/A LENS 25-1301-() RETAIN 1, 2 45A NONE N/A CIRCUIT CARD ASSY 11-5341-() MODIFY 1 55 NONE 6 NA SCREW ASSY NAS1301-4-4 RETAIN 1 60 NONE 1 ACCESS CVR. ASSY 11-5339-() RETAIN 185 NONE 1 N/A LEAD WIRE ASSY 11-5337-() RETAIN 280 NONE N/A MTG PLATE ASSY 11-5328-() RETAIN 2, 3 65 NONE 1 N/A CONNECTOR J1 CO-7636 RETAIN 2,3 65A 60-4940-3 1 *** GASKET (KIT) NONE INSTALL 2,3 70 NONE 1 NA CONNECTOR J2 CO-7622 RETAIN 2,3 70A 60-4940-1 1 **7 GASKET (KIT) NONE INSTALL 2,3 115 NONE 3 N/A XMFR. T1,12,13 55-1085-1 RETAIN REF N/A 10-1624-1 EA $5.45 KIT, MOD NONE INSTALL NOTE: ITEMS WITH THE ***, ARE COMPONENTS OF THE KIT AND ARE NOT SEPARATELY PRICED.
DATE 10/15/93 TITLE: PASSENGER SERVICE UNIT 10-1571-33-0041 REV. DATE _ FIGURE NO. - PAGE NO. 8
GRIMES AEROSPACE SERVICE
BULLETIN
PASSENGER SERVICE UNIT GRIMES PART NUMBER 10-1571-(SERIES) FOKKER 100 33¢ 225A DATE 10/15/93 TITLE: PASSENGER SERVICE UNIT 10-1571-33-0041 REV. — DATE FIGURE NO. PAGE NO.
GRIMES SERVICE
AEROSPACE
BULLETIN
PASSENGER SERVICE UNIT GRIMES PART NUMBER 10-1571-(SERIES) FOKKER 100 -35 135- —115 K3
•35 130- 10- 15 70A
65. -35 65A 20- -115 35 125~ -35 75~ -105 -35 25 II0A 95,100 DATE 10/15/93 TITLE: PASSENGER SERVICE UNIT 10-1571-33-0041 REV. DATE FIGURE NO. 2 PAGE NO.
GRIMES AEROSPACE SERVICE
BULLETIN
PASSENGER SERVICE UNIT GRIMES PART NUMBER 10-1571-(SERIES) FOKKER 100 J2
• Sealant (7 Places)
- 60-4940-1 - 60-4940-3 DATE 10/15/93 TITLE: PASSENGER SERVICE UNIT 10-1571-33-0041 REV. _ DATE _ _ FIGURE NO. _ 3 PAGE NO.
GRIMES AEROSPACE SERVICE
BULLETIN
PASSENGER SERVICE UNIT GRIMES PART NUMBER 10-1571-(SERIES) FOKKER 100 300 CALL 7 ON IISVAC 400Hz AC GNO NO SMOKING OPTIONAL SPKR TEST GNO Electrical Schematic Diagram DATE 10/15/93 TITLE: PASSENGER SERVICE UNIT 10-1571-33-0041 REV. _ DATE _ FIGURE NO.4 PAGE NO. 12