KIDDE AEROSPACE & DEFENSE

SERVICE BULLETIN FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) –

AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER

OPERATION

January 13/22 CFD-26-3 523-0832622 U.S. Export Classification: EAR 9E991 Page 24 of 30

Zeq(Calc) = 1 / {(1/Z 1 + 1/Z2 + 1/Z3)}

The Zeq(calc) value must be less than the Zeq(limit) value. Zeq(limit) = Zeq(snsr) from Table 1 for the salt type sensing element + ½ * CWR measured value in ohms and greater than 0.4 Ω.

EXAMPLE: Target Limit = 127 Ω CWR = 4 Ω Zeq(Calc) < 127 + 4/2 Zeq(Calc) < 129 Z 1 = 170 Ω Z 2 = 400 Ω Z 3 = 1200 Ω Zeq(Calc) = 1 / {(1/170 + 1/400 + 1/1200)} Zeq(Calc) = 108 Ω Unit Passes

NOTE: The calculation is derived to account for differences between this test procedure and the Acceptance Test Procedure (ATP).

(h) Log the Zeq(limit) and Zeq(calc) value on the Data Sheet Table 2 (Refer Appendix A).

NOTE: The Zeq(Calc) value may be calculated once all 3 test points within a test location are complete. It is not required to calculate Zeq(Calc) before moving on from a single test location.

(i) Remove the heat gun from sensing element and let it cool for three (3) minutes or until the “Room Temperature Impedance” is above the limit (see next step). Wipe the sensing element with a damp cloth to restore it to room temperature.

1) If the sensing element does not result in a Zeq value less than the limit with the heat gun applied, then check the connections and repeat Steps c) thru g) and if necessary change the test connection to the sensing element to the end nearest the test location.

2) If the sensing element does not result in a Zeq value less than the limit with the heat gun applied upon retest, then refer to Section 3.C.(5).(b) Post Test for values that are out of tolerance.

KIDDE AEROSPACE & DEFENSE

SERVICE BULLETIN FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) –

AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER

OPERATION

January 13/22 CFD-26-3 523-0832622 U.S. Export Classification: EAR 9E991 Page 25 of 30

NOTE: If the “Room Temperature Impedance” increases abov e the limit for five (5) or more seconds prior to three (3) minutes with the damp cloth removed, the full three (3) minutes wait time is NOT required (can proceed to next test location).

(j) Measure and record the “Room Temperature Impedance” using the LCR me ter and SCI Measurement criteria. The value must be between 10 kΩ and 3MΩ. Log the value on the Data Data Sheet Table 2 (Refer Appendix A). Refer to Section 3.C.(5).(b) Post Test for values that are out of tolerance.

(k) Heat the 1 st test point in the second test location for a minimum of 60 seconds (1 minute) and no more than 120 seconds (2 minutes). Refer to Section 3.B.(4).(a) Test Locations for instructions on test locations.

NOTE: If the “Heated Impedance” is below the Zeq (limit) for five (5) or more seconds prior to 60 seconds, the full 60 seconds wait time is NOT required (can proceed to next test location).

NOTE: For optimum test execution it is best to measure the CWR value first, then calculate the Zeq(limit). Perform the individual heated test points and assess if they are below the Zeq(limit). If not, continue heating additional local test points up to three

(3) total before advancing to the next test location of the sensing element. Individual Z readings are not required to be ≤ Zeq(limit). Individual Z readings must be >0.4 Ω and < 3 M Ω (the upper room temperature impedance limit). Repeat the same testing method until all three (3) test locations of the sensing element are tested. Then go back and perform the Zeq(Calc) math calculations to assess pass/fail.

(l) Measure and record the “Heated Impedance” using the LCR meter and SCI Measurement criteria. Repeat Steps k) thru m) for a total of three (3) times within this test location area (3 readings) with a 3 to 4 inch (7.62 to 10.16 cm) spacing.

KIDDE AEROSPACE & DEFENSE

SERVICE BULLETIN FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) –

AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER

OPERATION

January 13/22 CFD-26-3 523-0832622 U.S. Export Classification: EAR 9E991 Page 26 of 30

NOTE: If the “Heated Impedance” Z value is below the Zeq(limit) for test point 1, test point 2, or test point 3, no additional test points within this test location are required and can be entered directly on the data sheet as the final Zeq(Calc).

(m) Record each value on the data sheet and then use the values to calculate the Zeq(calc) value using the formula below:

Zeq(Calc) = 1 / {(1/Z 1 + 1/Z2 + 1/Z3)}

The Zeq(calc) value must be less than the Zeq(limit) value. Zeq(limit) = Zeq(snsr) from Table 2 for the salt type sensing element + ½ * CWR measured value in ohms and greater than 0.4 Ω.

(n) Log the Zeq(limit) and Zeq(calc) value on the Data Sheet Table 2 (Refer Appendix A).

NOTE: The Zeq(Calc) limit may be calculated once all three (3) test points on a sensing element are complete. It is not required to calculate Zeq(Calc) before moving on from a test location.

(o) Remove the heat gun from sensing element and let it cool for at least 3 minutes. A damp cloth can be used to restore sensing element to room temperature.

1) If the sensing element does not result in a Zeq value less than the limit with the heat gun applied, then check the connections and repeat steps j) through m) and if necessary change the test connection to the sensing element to the end nearest the test location.

2) If the sensing element does not result in a Zeq value less than the limit with the heat gun applied upon retest, then refer to Section 3.C.(5).(b) Post Test for values that are out of tolerance.

NOTE: If the “Room Temperature Impedance” increases above the limit for five (5) or more seconds prior to three (3) minutes with the damp cloth removed, the full three (3) minutes wait time is NOT required (can proceed to next test location).

KIDDE AEROSPACE & DEFENSE

SERVICE BULLETIN FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) –

AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER

OPERATION

January 13/22 CFD-26-3 523-0832622 U.S. Export Classification: EAR 9E991 Page 27 of 30

(p) Measure and record the “Room Temperature Impedance” using the LCR meter and SCI Measurement criteria. The value must be ≥ 10 k Ω and < 3 MΩ. Log the value on the Data Sheet Table 2 (Refer Appendix A). Refer to Section 3.C.(5).(b) Post Test for values that are out of tolerance.

(q) Heat the 1 st test point in the third test location for a minimum of 60 seconds (1 minute) and no more than 120 seconds (2 minutes). Refer to Section 3.B.(4).(a) Test Locations for instructions on test locations.

NOTE: If the “Heated Impedance” is below the Zeq limit for 5 or more seconds prior to 60 seconds, the full 60 seconds wait time is NOT required (can proceed to next test location).

NOTE: For optimum test execution it is best to measure the CWR value first, then calculate the Zeq(limit). Perform the individual heated test points and assess if they are below the Zeq(limit). If not, continue heating additional local test points up to three

(3) total before advancing to the next test location of the sensing element. Individual Z readings are not required to be ≤ Zeq(limit). Individual Z readings must be >0.4 Ω and < 3 M Ω (the upper room temperature impedance limit). Repeat the same testing method until all three (3) test locations of the sensing element are tested. Then go back and perform the Zeq(Calc) math calculations to assess pass/fail.

(r) Measure and record the “Heated Impedance” using the LCR meter and SCI Measurement criteria. Repeat Steps q) thru s) for a total of three (3) times within this test location area (3 readings) with a 3 to 4 (7.62 to 10.16 cm) inch spacing.

NOTE: If the “Heated Impedance” Z value is below the Zeq(limit) for test point 1, test point 2, or test point 3, no additional test points within this test location are required and can be entered directly on the data sheet as the final Zeq(Calc).

(s) Record each value on the data sheet and then use the values to calculate the Zeq(calc) value using the formula below:

KIDDE AEROSPACE & DEFENSE

SERVICE BULLETIN FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) –

AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER

OPERATION

January 13/22 CFD-26-3 523-0832622 U.S. Export Classification: EAR 9E991 Page 28 of 30

Zeq = 1 / {(1/Z 1 + 1/Z2 + 1/Z3)}

The Zeq(calc) value must be less than the Zeq(limit) value. Zeq(limit) = Zeq(snsr) from Table 1 for the salt type sensing element + ½ * CWR measured value in Ohms and greater than 0.4 Ω.

(t) Log the Zeq(limit) and Zeq(calc) value on the Data Sheet Table 2 (Refer Appendix A).

NOTE: The Zeq(Calc) limit may be calculated once all 3 test points on a sensing element are complete. It is not required to calculate Zeq(Calc) before moving on from a test location .

(u) Remove the heat gun from sensing element and let it cool for at least 3 minutes. A damp cloth can be used to restore sensing element to room temperature.

1) If the sensing element does not result in a Zeq value less than the limit with the heat gun applied, then check the connections and repeat Steps p) thru s) and if necessary change the test connection to the sensing element to the end nearest the test location.

2) If the sensing element does not result in a Zeq value less than the limit with the heat gun applied upon retest, refer to Section 3.C.(5).(b) Post Test for values that are out of tolerance.

(v) Measure and record the “Room Temperature Impedance” after testing the third sensing element test location using the LCR meter and SCI Measurement criteria. The value must be ≥ 10 kΩ and < 3 MΩ. Log the value on the Data Sheet Table 2 (Refer Appendix A). Refer to Section 3.C.(5).(b) Post Test for values that are out of tolerance.

(w) Run the heat gun on fan only mode for at least five (5) minutes to cool, then turn off the heat gun.

(x) Ensure all data is logged on the Data Sheet Table 2 (Refer Appendix A).

(5) Post test

(a) Verify that all sensing element impedance (Z and Zeq(Calc)) measurements are within the applicable value limits listed in the attached Data Sheet Table 2 (Refer Appendix

KIDDE AEROSPACE & DEFENSE

SERVICE BULLETIN FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) –

AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER

OPERATION

January 13/22 CFD-26-3 523-0832622 U.S. Export Classification: EAR 9E991 Page 29 of 30

A). Verify that all test result entries are completed, passing results for each sensing element test location or sensing elements tested, and sensing element impedance (Z and Zeq(Calc)) measurements are within applicable value limits.

(b) Any unit that does not meet all requirements of Section 3.C. Test Procedure, does not meet the requirements of Federal Aviation Administration (FAA) Technical Standard Order (TSO)-C11e, is not airworthy and cannot be installed on an aircraft. Mark the “Reject” box at the bottom of Table 2 (Refer Appendix A).

(c) Ensure that the sensing element has returned to ambient temperature.

(d) Remove LCR meter test leads. Inspect the connector both ends of the CFD sensing element for damage. Replace the sensing element connector caps if applicable.

(e) Continue to Step 3.D. Identification Procedure.

D. RC - Re-identification of Equipment

(1) If the element fails any of the tests, continue to Section 3.D.(4).

(2) For conforming material, mark one face of the connector hex nut.

(3) Carefully recoil the sensing element to the same original coil diameter (approximately 7.5 inch), taking minimum bend radius into consideration (no kinks permitted), free from bends within 1 inch (2.54 cm) of hex nut of sensing element connectors, and replace it in the original packaging material.

NOTE: Minimum Bend radius is 1 inch (2.54 cm).

(4) Apply a dot to the exterior packaging and insert a copy of the Test Datasheet in the packaging.

NOTE: The identification procedure must be accomplished in order for the service bulletin to be complete.

If unit fails testing, send unit to address below with Record of Accomplishment form f illed out. Any unit that fails any portion of the test must not be installed/re-installed on an aircraft.

KIDDE AEROSPACE & DEFENSE

SERVICE BULLETIN FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) –

AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER

OPERATION

January 13/22 CFD-26-3 523-0832622 U.S. Export Classification: EAR 9E991 Page 30 of 30

Collins Aerospace Attn: CFD NOE Return 4200 Airport Dr.

Wilson, NC 27896

TELEPHONE: 1.888.265.5467 INTERNATIONAL: 1.319.295.5467 FAX NO: 1.319.295.4941

Email: kiddeCFDreturns@collins.com

(5) Record of Accomplishment

(a) Record the test results on the form in Appendix A.

NOTE: At the discretion of the OEM/customer, send the Record of Accomplishment to:

Email: AvionicsSupport@collins.com E. Test Refer to Section 3.C. RC – Procedure - Bench Top Thermal Test

F. Close-Up Not Applicable

KIDDE AEROSPACE & DEFENSE

SERVICE BULLETIN FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) –

AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER

OPERATION

January 13/22 CFD-26-3 523-0832622

U.S. Export Classification: EAR 9E991 Appendix A

APPENDIX A

KIDDE AEROSPACE & DEFENSE

SERVICE BULLETIN FIRE PROTECTION – AIRBUS CONTINUOUS FIRE DETECTOR (CFD) –

AIRBUS SENSING ELEMENT - FIELD TESTING OF CFD FOR PROPER

OPERATION

January 13/22 CFD-26-3 523-0832622

U.S. Export Classification: EAR 9E991 Appendix A

Test Datasheet - Bench Top Thermal Test P/N: Date: ____________ S/N – Date Code: Pre Test Remarks: ____________________________________________________ Test Site Ambient Conditions: Temperature: °F (°C) Pre-test sensing element CWR (30 Ω max) Location (PN, MID, SN) Description Target Z or Zeq(limit) (Ω) Measured Z (Ω) Calculated Zeq(Calc) (Ω)

PASS/FAIL (Circle One) Pre-Location 1 Room Temperature Impedance (Z) ≥ 10 k Ω & < 3 M Ω N/A Pass Fail Location 1 ( ) Heated Impedance(Z) / Zeq(Calc) (Zeq(limit) = Zeq(Snsr) from Table 1 + ½*CWRmeas > 0.4 Ω & ≤ Zeq(Snsr) + ½ CWR meas Ω ≤ _______ *Z1= Pass Fail *Z2= *Z3= Pre-Location 2 Room Temperature Impedance (Z) ≥ 10 k Ω & < 3 M Ω N/A Pass Fail Location 2 ( ) Heated Impedance(Z) / Zeq(Calc) (Zeq(limit) = Zeq(Snsr) from Table 1 + ½*CWRmeas > 0.4 Ω & ≤ Zeq(Snsr) + ½ CWR meas Ω ≤ _______ *Z1= Pass Fail *Z2= *Z3= Pre-Location 3 Room Temperature Impedance (Z) ≥ 10 k Ω & < 3 M Ω N/A Pass Fail Location 3 ( ) Heated Impedance(Z) / Zeq(Calc) (Zeq(limit) = Zeq(Snsr) from Table 1 + ½*CWRmeas > 0.4 Ω & ≤ Zeq(Snsr) + ½ CWR meas Ω ≤ _______ *Z1= Pass Fail *Z2= *Z3=

Post Test Room Temperature Impedance (Z) ≥ 10 k Ω & < 3 M Ω N/A Pass Fail

Sensing Element Performance: Accept [ ] Reject [ ]

Test Technicia n: Date:

Test Witness: Date:

*Individual Z readings are not required to be ≤ Zeq(limit). Individual Z readings must be >0.4 Ω and < 3 M Ω (the upper room temperature impedance limit).

Table 2: Test Datasheet - Bench Top Thermal Test