- Holder
- Head Balloons Inc.
- Revision
- 6
- Revised
- April 8, 2009
- Status
- Current
- Product
- Aircraft · Balloon
- Certification basis
- Part 21, Part 31
- Models
- 6
- Registered
- 190 aircraft
The release keeps the latest revision of each data sheet. Model names are as the data sheet lists them.
On this page
Models · 6
| Model | Also known as | Note |
|---|---|---|
| AX7-77b | ||
| AX9-118 | ||
| AX8-88 | ||
| AX7-77 | ||
| AX8-105 | ||
| AX8-88b |
Airworthiness directives · 1
ADs whose products are models on this data sheet, matched by model and maker.
Registered aircraft
Registry models that point at this data sheet, with their registered aircraft.
STCs approved under this data sheet · 13
STC SB10564SCInstallation of Night Position LightsSTC SB09657RCInstallation of Aircraft Position LightsSTC SB04407ATInstallation of the DBI-III OmegaSTC SB04010CHReplace the Head Balloons Burner system with the Balony Kubicek Burner Model IGNIS 2 Units, S/N 1125 and 1126STC SB04011CHReplace the Head Balloons Burner system with the Balony Kubicek Burner Model IGNIS 2 Units, S/N 1125 and 1126.STC SB00463ATInstallation of Cameran basket and burner systemsSTC SL2263SOInstallation of Aerostar (Raven) Models CW, W, and RW basket and burner systems.STC SB02317ATInstallation of Sky Balloons (TC B01CE) baskets (sizes: 1.29m X 1.07M, 1.55M X 1.19M, and 1.80M X 1.29M) and burners (BR1 double burner and BR2 Mistral Double Burner) under Head Balloons' Model AX7-77, AX7-77b, AX8-88, AX8-88b, AX8-105 and AX9-118 envelopes.STC SL2407SOAttachment of Head Balloons hot air balloon envelopes with Adams Balloon Loft Model A50/A50S basket, burner, instruments, and fuel system components.STC SB01867ATAttachment of Head Balloons hot air balloon envelopes with Lindstrand Balloon basket, burner, instruments, and fuel system components.STC SB01048ATInstallation of Thunder and Colt40X40, 40X48, 40X54, and 40X60 basket assemblies.STC SB534CHInstallation of basket/burner system and fuel tanks. (AX8-88B S/N 161)STC SL1748SOInstallation of Balloon Works sizes3.9, 4.0, 4.5, 4.9, and 5.0 baskets.
What the data sheet says
From the PDF’s text layer, line by line: tables lose their columns. The PDF is the record.
Page No. 1 2 3
Rev. No. 5 6 6
Reformatted 6/94.
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
A29SO
Revision 6
Head Balloons
AX7-77
AX8-88
AX7-77b
AX8-105
AX9-118
AX8-88b
April 8, 2009
TYPE CERTIFICATE DATA SHEET NO. A29SO
This data sheet, which is part of Type Certificate No. A29SO prescribes conditions and limitations under which the product for
which the type certificate was issued meets the Airworthiness requirements of the Federal Aviation Regulations.
Type Certificate Holder: Head Balloons, Inc.
P.O. Box 28
Helen, Georgia 30545
I. - Model AX7-77 Hot Air Balloon, Approved June 1, 1984.
Air Heater Head DBII Burner
Fuel Commercial LPG or Propane
Maximum Weight 1400 pounds (This weight includes the weight of the envelope.)
Allowable Envelope Temperature 250° F
Fuel Capacity Two, Three or Four Ten-Gall on Propane Cylinder, Worthington
Model 43-04 or Manchester Model 43
Serial Numbers Eligible 2 and subsequent
II. - Model AX8-88 Hot Air Balloon, Approved August 15, 1984
Air Heater Head DBII burner
Fuel Commercial LPG or Propane
Maximum Weight 1500 pounds (This weight includes the weight of the envelope.)
Allowable Envelope Temperature 250° F
Fuel Capacity Two, Three or Four Ten-Ga llon Propane Cylinder, Worthington
Model 43-04 or Manchester Model 43
Serial Numbers 102 and subsequent
III. Model AX7-77b Hot Air Balloon, Approved October 1, 1985
Air Heater Head DBII Burner
Fuel Commercial LPG or Propane
Maximum Weight 1400 Pounds (This weight include s the weight of the envelope.)
Allowable Envelope Temperature 250° F
Fuel Capacity Two, Three or Four Ten-Gall on Propane Cylinder, Worthington
Model 43-04 or Manchester Model 43.
IV. Model AX8-105 Hot Air Balloon, Approved July 23, 1987
Air Heater Head DBII Burner
Fuel Commercial LPG or Propane
Maximum Weight 1650 pounds (This weight includes the weight of the envelope.)
Allowable Envelope Temperature 250°F
Fuel Capacity Two, Three or Four Ten-Gall on Propane Cylinder, Worthington
Model 43-04 or Manchester Model 43.
V. Model AX9-118 Hot Air Balloon, Approved September 23, 1987
Air Heater Head DBII Burner
Fuel Commercial LPG or Propane
Maximum Weight 1650 pounds (This weight includes the weight of the envelope.)
Allowable Envelope Temperature 250°F
Fuel Capacity Two, Three or Four Ten-Gall on Propane Cylinder, Worthington
Model 43-04 or Manchester Model 43.
Serial Numbers Eligible 144 and subsequent
VI. - Model AX8-88b Hot Air Balloon, Approved October 6, 1989
Air Heater Head DBII Burner
Fuel Commercial LPG or Propane
Maximum Weight 1500 pounds (This weight includes the weight of the envelope.)
Allowable Envelope Temperature 250°F
Fuel Capacity Two, Three or Four Ten-Gall on Propane Cylinder, Worthington
Model 43-04 or Manchester Model 43
Serial Numbers Eligibl e 161 and subsequent
Page 3 A29SO
DATA PERTINENT TO ALL MODELS
Certification Basis Part 31 of the Federal Aviation Regulations dated July 1, 1964, as amended by 31-1
through 31-4. Application for Type Certif icate dated July 13, 1981. Type Certificate
No. A29SO issued June 1, 1984, amended August 15, 1984, October 1, 1985, July 23,
1987, September 23, 1987, and October 6, 1989.
Production Basis APIS, issued under FAR 21, Subpart F.
Export Eligibility Balloon will be eligible for issuance of an E xport Certificate of Airworthiness subject to
compliance with Federal Aviation Regula tion Part 21, Subpart L, Sections 21.321
through 21.339. The applicable procedures are contained in Advisory Circular
No. 21-2, latest revision.
Equipment The basic required equipment as prescribed in the applicable airworthiness regulations
(see certification basis) must be installed in the aircraft for certification. In addition,
the following equipment must be installed:
1. Burner lighter or sparker.
2. FAA approved flight manual.
Maintenance and Inspection The basket, burner, envelope and attaching means shall be inspected,. maintained and
repaired in accordance with Head Hot Air Balloon Maintenance Manual.
NOTE 1: (a) Prior to shipment of a balloon envelope (and necessary attaching system), produced for use with a
burner/basket assembly that is eligible for use with that envelope, the production approval holder must
determine that the envelope and necessary attachi ng system conforms to the type design and is in a
condition for safe operation. A Statement of C onformity, FAA Form 8130-9, may be used for this
purpose. This envelope, in comb ination with an eligible burner/basket assembly may be registered and
is eligible for issuance of a standard airworthin ess certificate when the applicant for such certificate
shows, and the Administrator finds, that the envel ope, burner, and basket combination conforms to the
type design and is in a condition for safe operation.
(b) Balloon burner/basket assemb lies specifically designed for quick removal and installation from one
envelope to another may be accomplished by th e pilot/owner who holds at least a private pilot
certificate. Appropriate entries must be made in the balloon records noting the removal and/or
installation of bur ner/basket assemblies.
(c) Appropriate entries into balloon records of burner/ basket assembly removals and installations must be
made by FAA certificated mechanics if the p ilot/owner is not eligible to accomplish this task.
...END...