- Holder
- Lindstrand Balloons USA Inc.
- Revision
- 13
- Revised
- July 8, 2022
- Status
- Current
- Product
- Aircraft · Balloon
- Certification basis
- Part 31
- Models
- 37
- Registered
- 159 aircraft
The release keeps the latest revision of each data sheet. Model names are as the data sheet lists them.
On this page
Models · 37
| Model | Also known as | Note |
|---|---|---|
| 260A | Formerly Kempner, then Elisabeth A. | |
| 77B | Formerly Kempner, then Elisabeth A. | |
| 90B | Formerly Kempner, then Elisabeth A. |
Airworthiness directives · 1
ADs whose products are models on this data sheet, matched by model and maker.
Registered aircraft
Registry models that point at this data sheet, with their registered aircraft.
Arbc Inc DBA Lindstrand 77X38 registered aircraftArbc Inc DBA Lindstrand 60X34 registered aircraftLindstrand Balloons 60X14 registered aircraft
See all 23 registry modelsSTCs approved under this data sheet · 25
STC SB10564SCInstallation of Night Position LightsSTC SB09657RCInstallation of Aircraft Position LightsSTC SB04407ATInstallation of the DBI-III Omega
See all 25 STCsWhat the data sheet says
From the PDF’s text layer, line by line: tables lose their columns. The PDF is the record.
Page No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
Rev. No. 12 10 10 10 10 10 10 10 10 10 10 10 10 10 11 11 11 12 13 12 12
DEPARTMENT OF TRANSPORTATION
FEDERAL AVIATION ADMINISTRATION
B00010CH
Revision 13
LINDSTRAND
USA
(KEMPNER)
42A 210A
56A 210S
56X 240A
58X
60A 260A
60X 310A
62X
65X 317A
69A 330A
69X 69B
77A 77B
77X 90B
90A 105B
105A 50E
120A 60E
140A 70E
150A 80E
160A 90E
180A 100E
CAN-90
LBL BOX
SPHERE-105
July 8, 2022
TYPE CERTIFICATE DATA SHEET NO. B00010CH
This data sheet, which is part of Type Certificate No. B00010CH, prescribes conditions and limitations under which the
product for which the type certificate was issued meets the airworthiness requirements of the Federal Aviation Regulations.
Type Certificate Holder: Lindstrand Balloons USA, Inc.
11440 Dandar Street
Galena, IL 61036
Type Certificate Holder Record: Elisabeth A. Kempner transferred TC
B00010CH to Lindstrand Balloons USA, Inc. on
April 30, 2008
I - Model 42A, Hot Air Balloon, Approved December 20, 1999
Envelope Volume: 42,000 cu.ft., drawing EA-042-A-001.
Air Heaters Lindstrand Jetstream Series 1 Burner Assembly:
Super Single Burner, drawing BU-007-A-001.
Double Burner, drawing BU-002-A-001.
Lindstrand Jetstream Series 2 Burner Assembly:
Double Burner, drawings BU-008-A-001 and BU-008-A-002.
Lindstrand Vortech Burner Assembly:
Double Burner, drawing BU-001-A-001.
Baskets Lindstrand Baskets to drawings BA-001-A-001, BA-004-A-001, BA-005-A-001, BA-006-A-
001, and BA-009-A-001.
Fuel Commercial LPG or Propane.
Maximum Weight 924 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF,
whichever is less. See approved Balloon Flight Manual.
Allowable Envelope
Temperature 1. Never exceed: 275oF.
2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to
275oF.
3. Maximum continuous: 257oF.
B00010CH 2 of 21
Minimum Crew One (1) Pilot.
Fuel Capacity Two standard cylinders must be present (see also NOTE 6).
Serial Nos.
Eligible 5135 and up.
II - Model 56A, Hot Air Balloon, Approved December 20, 1999
Envelope Volume: 56,000 cu.ft, drawing EA-056-A-001.
Air Heaters Lindstrand Jetstream Series 1 Burner Assembly:
Super Single Burner, drawing BU-007-A-001.
Double Burner, drawing BU-002-A-001.
Lindstrand Jetstream Series 2 Burner Assembly:
Double Burner, drawings BU-008-A-001 and BU-008-A-002.
Lindstrand Vortech Burner Assembly:
Double Burner, drawing BU-001-A-001.
Baskets Lindstrand Baskets to drawings BA-001-A-001, BA-002-A-001, BA-002-A-002, BA-005-A-
001, BA-006-A-001, BA-006-A-002, BA-007-A-001, and BA-009-A-001.
Fuel Commercial LPG or Propane.
Maximum Weight 1232 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF,
whichever is less. See approved Balloon Flight Manual.
Allowable Envelope
Temperature 1. Never exceed: 275oF.
2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to
275oF.
3. Maximum continuous: 257oF.
Minimum Crew One (1) Pilot.
Fuel Capacity Two standard cylinders must be present (see also NOTE 6).
Serial Nos.
Eligible 5135 and up.
III - Model 60A, Hot Air Balloon, Approved December 20, 1999
Envelope Volume: 60,000 cu.ft., drawing EA-060-A-001.
Air Heaters Lindstrand Jetstream Series 1 Burner Assembly:
Super Single Burner, drawing BU-007-A-001.
Double Burner, drawing BU-002-A-001.
Lindstrand Jetstream Series 2 Burner Assembly:
Double Burner, drawings BU-008-A-001 and BU-008-A-002.
Lindstrand Vortech Burner Assembly:
Double Burner, drawing BU-001-A-001.
Baskets Lindstrand Baskets to drawings BA-001-A-001, BA-002-A-001, BA-002-A-002, BA-003-A-
001, BA-003-A-002, BA-005-A-001, BA-006-A-001, BA-006-A-002, BA-007-A-001, and
BA-009-A-001.
Fuel Commercial LPG or Propane.
Maximum Weight 1320 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF,
whichever is less. See approved Balloon Flight Manual.
Allowable Envelope
Temperature 1. Never exceed: 275oF.
2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to
275oF.
3. Maximum continuous: 257oF.
Minimum Crew One (1) Pilot.
Fuel Capacity Two standard cylinders must be present (see also NOTE 6).
Serial Nos.
3 of 21 B00010CH
Eligible 5135 and up.
IV - Model 69A, Hot Air Balloon, Approved December 20, 1999
Envelope Volume: 69,000 cu.ft., drawing EA-069-A-001.
Air Heaters Lindstrand Jetstream Series 1 Burner Assembly:
Super Single Burner, drawing BU-007-A-001.
Double Burner, drawing BU-002-A-001.
Lindstrand Jetstream Series 2 Burner Assembly:
Double Burner, drawings BU-008-A-001 and BU-008-A-002.
Lindstrand Vortech Burner Assembly:
Double Burner, drawing BU-001-A-001.
Baskets Lindstrand Baskets to drawings BA-001-A-001, BA-002-A-001, BA-002-A-002, BA-003-A-
001, BA-003-A-002, BA-005-A-001, BA-006-A-001, BA-006-A-002, BA-007-A-001, BA-
009-A-001 and BA-262-A-001.
Fuel Commercial LPG or Propane.
Maximum Weight 1518 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF,
whichever is less. See approved Balloon Flight Manual.
Allowable Envelope
Temperature 1. Never exceed: 275oF.
2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to
275oF.
3. Maximum continuous: 257oF.
Minimum Crew One (1) Pilot.
Fuel Capacity Two standard cylinders must be present (see also NOTE 6).
Serial Nos.
Eligible 5135 and up.
V - Model 77A, Hot Air Balloon, Approved December 20, 1999
Envelope Volume: 77,000 cu.ft., drawing EA-077-A-001.
Air Heaters Lindstrand Jetstream Series 1 Burner Assembly:
Super Single Burner, drawing BU-007-A-001.
Double Burner, drawing BU-002-A-001.
Lindstrand Jetstream Series 2 Burner Assembly:
Double Burner, drawings BU-008-A-001 and BU-008-A-002.
Lindstrand Vortech Burner Assembly:
Double Burner, drawing BU-001-A-001.
Baskets Lindstrand Baskets to drawings BA-001-A-001, BA-002-A-001, BA-002-A-002, BA-003-A-
001, BA-003-A-002, BA-005-A-001, BA-006-A-001, BA-006-A-002, BA-007-A-001, BA-
008-A-001, BA-009-A-001, and BA-262-A-001.
Fuel Commercial LPG or Propane.
Maximum Weight 1694 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF,
whichever is less. See approved Balloon Flight Manual.
Allowable Envelope
Temperature 1. Never exceed: 275oF.
2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to
275oF.
3. Maximum continuous: 257oF.
Minimum Crew One (1) Pilot.
Fuel Capacity Two standard cylinders must be present (see also NOTE 6).
Serial Nos.
Eligible 5135 and up.
B00010CH 4 of 21
VI - Model 90A, Hot Air Balloon, Approved December 20, 1999
Envelope Volume: 90,000 cu.ft., drawing EA-090-A-001.
Air Heaters Lindstrand Jetstream Series 1 Burner Assembly:
Super Single Burner, drawing BU-007-A-001.
Double Burner, drawing BU-002-A-001.
Lindstrand Jetstream Series 2 Burner Assembly:
Double Burner, drawings BU-008-A-001 and BU-008-A-002.
Lindstrand Vortech Burner Assembly:
Double Burner, drawing BU-001-A-001.
Baskets Lindstrand Baskets to drawings BA-001-A-001, BA-002-A-001, BA-002-A-002, BA-003-A-001,
BA-003-A-002, BA-005-A-001, BA-006-A-001, BA-006-A-002, BA-007-A-001, BA-008-A-001,
BA-009-A-001, BA-011-A-001, BA-011-A-002, BA-012-A-001, BA-262-A-001, BA-263-A-001,
BA-264-A-001, BA-270-A-001, and BA-270-A-002.
Fuel Commercial LPG or Propane.
Maximum Weight 1980 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF,
whichever is less. See approved Balloon Flight Manual.
Allowable Envelope
Temperature 1. Never exceed: 275oF.
2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to
275oF.
3. Maximum continuous: 257oF.
Minimum Crew One (1) Pilot.
Fuel Capacity Two standard cylinders must be present (see also NOTE 6).
Serial Nos.
Eligible 5135 and up.
VII - Model 105A, Hot Air Balloon, Approved December 20, 1999
Envelope Volume: 105,000 cu.ft., drawing EA-105-A-001.
Air Heaters Lindstrand Jetstream Series 1 Burner Assembly:
Double Burner, drawing BU-002-A-001.
Lindstrand Jetstream Series 2 Burner Assembly:
Double Burner, drawings BU-008-A-001 and BU-008-A-002.
Lindstrand Vortech Burner Assembly:
Double Burner, drawing BU-001-A-001.
Baskets Lindstrand Baskets to drawings BA-002-A-001, BA-002-A-002, BA-003-A-001, BA-003-A-002,
BA-006-A-001, BA-006-A-002, BA-007-A-001, BA-008-A-001, BA-010-A-001, BA-011-A-001,
BA-011-A-002, BA-012-A-001, BA-262-A-001, BA-263-A-001, BA-264-A-001, BA-270-A-001,
and BA-270-A-002.
Fuel Commercial LPG or Propane.
Maximum Weight 2310 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF,
whichever is less. See approved Balloon Flight Manual.
Allowable Envelope
Temperature 1. Never exceed: 275oF.
2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to
275oF.
3. Maximum continuous: 257oF.
Minimum Crew One (1) Pilot.
Fuel Capacity Two standard cylinders must be present (see also NOTE 6).
Serial Nos.
Eligible 5135 and up.
5 of 21 B00010CH
VIII - Model 120A, Hot Air Balloon, Approved December 20, 1999
Envelope Volume: 120,000 cu.ft., drawing EA-120-A-001.
Air Heaters Lindstrand Jetstream Series 1 Burner Assembly:
Double Burner, drawing BU-002-A-001.
Triple Burner, drawing BU-004-A-001.
Lindstrand Jetstream Series 2 Burner Assembly:
Double Burner, drawings BU-008-A-001 and BU-008-A-002.
Triple Burner, drawings BU-010-A-001, BU-010-A-002, and BU-010-A-003.
Quad Burner, drawings BU-012-A-001, BU-012-A-002, and BU-012-A-003.
Lindstrand Vortech Burner Assembly:
Double Burner, drawing BU-001-A-001.
Baskets Lindstrand Baskets to drawings BA-003-A-001, BA-003-A-002, BA-008-A-001, BA-010-A-001,
BA-011-A-001, BA-011-A-002, BA-012-A-001, BA-013-A-001, BA-014-A-001, BA-015-A-001,
BA-034-A-001, BA-035-A-001, BA-040-A-001, BA-262-A-001, BA-263-A-001, BA-264-A-001,
BA-244-A-001, BA-265-A-001, BA-270-A-001, and BA-270-A-002.
Fuel Commercial LPG or Propane.
Maximum Weight 2640 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF,
whichever is less. See approved Balloon Flight Manual.
Allowable Envelope
Temperature 1. Never exceed: 275oF.
2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to
275oF.
3. Maximum continuous: 257oF.
Minimum Crew One (1) Pilot.
Fuel Capacity Two standard cylinders must be present (see also NOTE 6).
Serial Nos.
Eligible 5135 and up.
IX - Model 150A, Hot Air Balloon, Approved December 20, 1999
Envelope Volume: 150,000 cu.ft., drawing EA-150-A-001.
Air Heaters Lindstrand Jetstream Series 1 Burner Assembly:
Double Burner, drawing BU-002-A-001.
Triple Burner, drawing BU-004-A-001.
Lindstrand Jetstream Series 2 Burner Assembly:
Double Burner, drawings BU-008-A-001 and BU-008-A-002.
Triple Burner, drawings BU-010-A-001, BU-010-A-002, and BU-010-A-003.
Quad Burner, drawings BU-012-A-001, BU-012-A-002, and BU-012-A-003.
Lindstrand Vortech Burner Assembly:
Double Burner, drawing BU-001-A-001.
Baskets Lindstrand Baskets to drawings BA-011-A-001, BA-011-A-002, BA-012-A-001, BA-013-A-
001, BA-014-A-001, BA-015-A-001, BA-020-A-001, BA-031-A-001, BA-034-A-001, BA-
035-A-001, BA-040-A-001, BA-263-A-001, BA-264-A-001, BA-244-A-001, and BA-265-A-
001.
Fuel Commercial LPG or Propane.
Maximum Weight 3190 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF,
whichever is less. See approved Balloon Flight Manual.
Allowable Envelope
Temperature 1. Never exceed: 275oF.
2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to
275oF.
3. Maximum continuous: 257oF.
Minimum Crew One (1) Pilot.
Fuel Capacity Two standard cylinders must be present (see also NOTE 6).
B00010CH 6 of 21
Serial Nos.
Eligible 5135 and up.
X - Model 180A, Hot Air Balloon, Approved December 20, 1999
Envelope Volume: 180,000 cu.ft., drawing EA-180-A-001.
Air Heaters Lindstrand Jetstream Series 1 Burner Assembly:
Double Burner, drawing BU-002-A-001.
Triple Burner, drawing BU-004-A-001.
Lindstrand Jetstream Series 2 Burner Assembly:
Double Burner, drawing BU-008-A-001, BU-008-A-002.
Triple Burner, drawings BU-010-A-001, BU-010-A-002, and BU-010-A-003.
Quad Burner, drawings BU-012-A-001, BU-012-A-002, and BU-012-A-003.
Lindstrand Vortech Burner Assembly:
Double Burner, drawing BU-001-A-001.
Baskets Lindstrand Baskets to drawings BA-013-A-001, BA-014-A-001, BA-015-A-001, BA-020-A-
001, BA-021-A-001, BA-022-A-001, BA-023-A-001, BA-024-A-001, BA-025-A-001, BA-
028-A-001, BA-030-A-001, BA-031-A-001, BA-032-A-001, BA-033-A-001, BA-034-A-001,
BA-035-A-001, BA-036-A-001, BA-037-A-001, BA-038-A-001, BA-040-A-001, BA-244-A-
001, and BA-265-A-001.
Fuel Commercial LPG or Propane.
Maximum Weight 3586 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF,
whichever is less. See approved Balloon Flight Manual.
Allowable Envelope
Temperature 1. Never exceed: 275oF.
2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to
275oF.
3. Maximum continuous: 257oF.
Minimum Crew One (1) Pilot.
Fuel Capacity Two standard cylinders must be present (see also NOTE 6).
Serial Nos.
Eligible 5135 and up.
XI - Model 210A, Hot Air Balloon, Approved December 20, 1999
Envelope Volume: 210,000 cu.ft., drawing EA-210-A-001.
Air Heaters Lindstrand Jetstream Series 1 Burner Assembly:
Double Burner, drawing BU-002-A-001.
Triple Burner, drawing BU-004-A-001.
Lindstrand Jetstream Series 2 Burner Assembly:
Double Burner, drawing BU-008-A-001, BU-008-A-002.
Triple Burner, drawings BU-010-A-001, BU-010-A-002, and BU-010-A-003.
Quad Burner, drawings BU-012-A-001, BU-012-A-002, and BU-012-A-003.
Lindstrand Vortech Burner Assembly:
Double Burner, drawing BU-001-A-001.
Baskets Lindstrand Baskets to drawings BA-015-A-001, BA-020-A-001, BA-021-A-001, BA-022-A-
001, BA-023-A-001, BA-024-A-001, BA-025-A-001, BA-026-A-001, BA-028-A-001, BA-
030-A-001, BA-031-A-001, BA-032-A-001, BA-033-A-001, BA-034-A-001, BA-035-A-001,
BA-036-A-001, BA-037-A-001, BA-038-A-001, and BA-040-A-001.
Fuel Commercial LPG or Propane.
Maximum Weight 4180 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF,
whichever is less. See approved Balloon Flight Manual.
Allowable Envelope
Temperature 1. Never exceed: 275oF.
2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to
275oF.
3. Maximum continuous: 257oF.
7 of 21 B00010CH
Minimum Crew One (1) Pilot.
Fuel Capacity Two standard cylinders must be present (see also NOTE 6).
Serial Nos.
Eligible 5135 and up.
XII - Model 240A, Hot Air Balloon, Approved December 20, 1999
Envelope Volume: 240,000 cu.ft., drawing EA-240-A-001.
Air Heaters Lindstrand Jetstream Series 1 Burner Assembly:
Triple Burner, drawing BU-004-A-001.
Lindstrand Jetstream Series 2 Burner Assembly:
Triple Burner, drawings BU-010-A-001, BU-010-A-002, and BU-010-A-003.
Quad Burner, drawings BU-012-A-001, BU-012-A-002, and BU-012-A-003.
Baskets Lindstrand Baskets to drawings BA-021-A-001, BA-022-A-001, BA-023-A-001,
BA-024-A-001, BA-025-A-001, BA-026-A-001, BA-028-A-001, BA-030-A-001, BA-031-A-
001, BA-032-A-001, BA-033-A-001, BA-034-A-001, BA-035-A-001, BA-036-A-001, and
BA-037-A-001.
Fuel Commercial LPG or Propane.
Maximum Weight 4800 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF,
whichever is less. See approved Balloon Flight Manual.
Allowable Envelope
Temperature 1. Never exceed: 275oF.
2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to
275oF.
3. Maximum continuous: 257oF.
Minimum Crew One (1) Pilot.
Fuel Capacity Two standard cylinders must be present (see also NOTE 6).
Serial Nos.
Eligible 5135 and up.
XIII - Model 260A, Hot Air Balloon, Approved December 20, 1999
Envelope Volume: 260,000 cu.ft., drawing EA-260-A-001.
Air Heaters Lindstrand Jetstream Series 1 Burner Assembly:
Triple Burner, drawing BU-004-A-001.
Lindstrand Jetstream Series 2 Burner Assembly:
Triple Burner, drawings BU-010-A-001, BU-010-A-002, and BU-010-A-003.
Quad Burner, drawings BU-012-A-001, BU-012-A-002, and BU-012-A-003.
Baskets Lindstrand Baskets to drawings BA-022-A-001, BA-023-A-001, BA-024-A-001, BA-025-A-
001, BA-026-A-001, BA-028-A-001, BA-030-A-001, BA-031-A-001, BA-032-A-001, BA-
033-A-001, BA-036-A-001, and BA-037-A-001.
Fuel Commercial LPG or Propane.
Maximum Weight 5200 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF,
whichever is less. See approved Balloon Flight Manual.
Allowable Envelope
Temperature 1. Never exceed: 275oF.
2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to
275oF.
3. Maximum continuous: 257oF.
Minimum Crew One (1) Pilot.
Fuel Capacity Two standard cylinders must be present (see also NOTE 6).
Serial Nos.
Eligible 5135 and up.
B00010CH 8 of 21
XIV - Model 310A, Hot Air Balloon, Approved December 20, 1999
Envelope Volume: 310,000 cu.ft., drawing EA-310-A-001.
Air Heaters Lindstrand Jetstream Series 2 Burner Assembly:
Triple Burner, drawings BU-010-A-001, BU-010-A-002, and BU-010-A-003.
Quad Burner, drawings BU-012-A-001, BU-012-A-002, and BU-012-A-003.
Baskets Lindstrand Baskets to drawings BA-022-A-001, BA-024-A-001, BA-025-A-001, BA-026-A-
001, BA-027-A-001, BA-028-A-001, BA-030-A-001, BA-031-A-001, BA-032-A-001, BA-
033-A-001, BA-036-A-001, and BA-037-A-001.
Fuel Commercial LPG or Propane.
Maximum Weight 6200 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF,
whichever is less. See approved Balloon Flight Manual.
Allowable Envelope
Temperature 1. Never exceed: 275oF.
2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to
275oF.
3. Maximum continuous: 257oF.
Minimum Crew One (1) Pilot.
Fuel Capacity Two standard cylinders must be present (see also NOTE 6).
Serial Nos.
Eligible 5135 and up.
XV - Model 69B, Hot Air Balloon, Approved December 20, 1999
Envelope Volume: 69,000 cu.ft., drawing EB-069-A-001.
Air Heaters Lindstrand Jetstream Series 1 Burner Assembly:
Super Single Burner, drawing BU-007-A-001.
Double Burner, drawing BU-002-A-001.
Lindstrand Jetstream Series 2 Burner Assembly:
Double Burner, drawings BU-008-A-001 and BU-008-A-002.
Lindstrand Vortech Burner Assembly:
Double Burner, drawing BU-001-A-001.
Baskets Lindstrand Baskets to drawings BA-001-A-001, BA-002-A-001, BA-002-A-002, BA-003-A-
001, BA-003-A-002, BA-005-A-001, BA-006-A-001, BA-007-A-001, and BA-009-A-001.
Fuel Commercial LPG or Propane.
Maximum Weight 1518 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF,
whichever is less. See approved Balloon Flight Manual.
Allowable Envelope
Temperature 1. Never exceed: 275oF.
2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to
275oF.
3. Maximum continuous: 257oF.
Minimum Crew One (1) Pilot.
Fuel Capacity Two standard cylinders must be present (see also NOTE 6).
Serial Nos.
Eligible 5135 and up.
XVI - Model 77B, Hot Air Balloon, Approved December 20, 1999
Envelope Volume: 77,000 cu.ft., drawing EB-077-A-001.
Air Heaters Lindstrand Jetstream Series 1 Burner Assembly:
Super Single Burner, drawing BU-007-A-001.
Double Burner, drawing BU-002-A-001.
9 of 21 B00010CH
Lindstrand Jetstream Series 2 Burner Assembly:
Double Burner, drawings BU-008-A-001 and BU-008-A-002.
Lindstrand Vortech Burner Assembly:
Double Burner, drawing BU-001-A-001.
Baskets Lindstrand Baskets to drawings BA-001-A-001, BA-002-A-001, BA-002-A-002, BA-003-A-
001, BA-003-A-002, BA-005-A-001, BA-006-A-001, BA-007-A-001, BA-008-A-001, and
BA-009-A-001.
Fuel Commercial LPG or Propane.
Maximum Weight 1694 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF,
whichever is less. See approved Balloon Flight Manual.
Allowable Envelope
Temperature 1. Never exceed: 275oF.
2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to
275oF.
3. Maximum continuous: 257oF.
Minimum Crew One (1) Pilot.
Fuel Capacity Two standard cylinders must be present (see also NOTE 6).
Serial Nos.
Eligible 5135 and up.
XVII - Model 90B, Hot Air Balloon, Approved December 20, 1999
Envelope Volume: 90,000 cu.ft., drawing EB-090-A-001.
Air Heaters Lindstrand Jetstream Series 1 Burner Assembly:
Super Single Burner, drawing BU-007-A-001.
Double Burner, drawing BU-002-A-001.
Lindstrand Jetstream Series 2 Burner Assembly:
Double Burner, drawings BU-008-A-001 and BU-008-A-002.
Lindstrand Vortech Burner Assembly:
Double Burner, drawing BU-001-A-001.
Baskets Lindstrand Baskets to drawings BA-001-A-001, BA-002-A-001, BA-002-A-002, BA-003-A-001,
BA-003-A-002, BA-005-A-001, BA-006-A-001, BA-007-A-001, BA-008-A-001, BA-009-A-001,
BA-011-A-001, BA-012-A-001, BA-262-A-001, BA-263-A-001, BA-264-A-001, BA-270-A-001,
and BA-270-A-002.
Fuel Commercial LPG or Propane.
Maximum Weight 1989 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF,
whichever is less. See approved Balloon Flight Manual.
Allowable Envelope
Temperature 1. Never exceed: 275oF.
2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to
275oF.
3. Maximum continuous: 257oF.
Minimum Crew One (1) Pilot.
Fuel Capacity Two standard cylinders must be present (see also NOTE 6).
Serial Nos.
Eligible 5135 and up.
XVIII - Model 105B, Hot Air Balloon, Approved December 20, 1999
Envelope Volume: 105,000 cu.ft., drawing EB-105-A-001.
Air Heaters Lindstrand Jetstream Series 1 Burner Assembly:
Super Single Burner, drawing BU-007-A-001.
Double Burner, drawing BU-002-A-001.
Lindstrand Jetstream Series 2 Burner Assembly:
Double Burner, drawings BU-008-A-001 and BU-008-A-002.
Lindstrand Vortech Burner Assembly:
B00010CH 10 of 21
Double Burner, drawing BU-001-A-001.
Baskets Lindstrand Baskets to drawings BA-002-A-001, BA-002-A-002, BA-003-A-001, BA-003-A-002,
BA-006-A-001, BA-007-A-001, BA-008-A-001, BA-010-A-001, BA-011-A-001, BA-012-A-001,
BA-262-A-001, BA-263-A-001, BA-264-A-001, BA-270-A-001, and BA-270-A-002.
Fuel Commercial LPG or Propane.
Maximum Weight 2310 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF,
whichever is less. See approved Balloon Flight Manual.
Allowable Envelope
Temperature 1. Never exceed: 275oF.
2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to
275oF.
3. Maximum continuous: 257oF.
Minimum Crew One (1) Pilot.
Fuel Capacity Two standard cylinders must be present (see also NOTE 6).
Serial Nos.
Eligible 5135 and up.
XIX - Model CAN-90, Hot Air Balloon, Approved December 20, 1999
Envelope Volume: 90,000 cu.ft., drawing SS-009-A-001.
Air Heaters Lindstrand Jetstream Series 1 Burner Assembly:
Super Single Burner, drawing BU-007-A-001.
Double Burner, drawing BU-002-A-001.
Lindstrand Jetstream Series 2 Burner Assembly:
Double Burner, drawings BU-008-A-001 and BU-008-A-002.
Lindstrand Vortech Burner Assembly:
Double Burner, drawing BU-001-A-001.
Baskets Lindstrand Baskets to drawings BA-001-A-001, BA-002-A-001, BA-002-A-002, BA-003-A-001,
BA-003-A-002, BA-005-A-001, BA-006-A-001, BA-007-A-001, BA-008-A-001, BA-009-A-001,
BA-011-A-001, BA-011-A-002, BA-012-A-001, BA-262-A-001, BA-263-A-001, BA-264-A-001,
BA-270-A-001, and BA-270-A-002.
Fuel Commercial LPG or Propane.
Maximum Weight 1980 lbs, or to the weight requiring a maximum continuous envelope temperature of 257ºF,
whichever is less. See approved Balloon Flight Manual.
Allowable Envelope
Temperature 1. Never exceed: 275oF.
2. For no longer than 10 minutes continuous or 10 minutes per 2 hours of flight: 257oF. to
275oF.
3. Maximum continuous: 257oF.