Page MG 6 - 11 ( 6 ) System Marking . The rotorcraft should be permanently and legibly marked, as applicable, in the locations specified below (a minimum letter height of ¼ inch is recommended):
( i ) Adjacent to the overboard vent opening:
CAUTION
LIQUID OXYGEN VENT
( i i ) On outside surface of f iller box cover plate:
LIQUID OXYGEN (BREATHING) FILL ACCESS
(iii ) On underside surface of filler box cover plate:
CAUTION - KEEP CLEAN, DRY, AND FREE FROM OILS
( i v ) In prominent place when filler bo x is open, preferably near liquid oxygen drain valve:
DO NOT OPEN DRAIN VALVE UNTIL DRAIN HOSE
AND DRAIN TANK ARE CONNECTED
( v ) Other placards, such as one at the converter cautioning about the presence of liquid oxygen, may also be appropriate.
( 7 ) Other installation criteria are given in Chapter 6, AC 43.13-2A, Acceptable Methods, Techniques, and Practices-Aircraft Alterations, dated June 9, 1977, and should be given full consideration.
(D) Precautions . The referenced SAE report contains precautions peculiar to a liquid oxygen installation, and this material should be reviewed. It should also be emphasized that liquid oxygen equipment and the aircraft being serviced must be electrically grounded during servicing to prevent an accumulation of static electricity and discharge. The following considerations are included for special emphasis:
( 1 ) System Cleanliness . The completed installation should be free of oil, grease, fuels, water, dust, dirt, objectionable odors, or any other foreign matter, both internally and externally prior to introducing oxygen in the system.
( 2 ) Closures . Lines which are required to be disconnected, due to the location of the converter within the rotorcraft during rotorcraft maintenance checks or overhaul, should be capped to prevent materials which are incompatible with oxygen from entering the system when the system integrity is broken. Caps which introduce moisture and tapes that leave adhesive deposits shall not be used for these purposes.
Page MG 6 - 12 All openings of lines and fittings shall be kept securely capped until closed within the installation.
( 3 ) Degreasing . All components of the oxygen system should be procured for oxygen service use in an “oxygen clean” condition. Parts of the oxygen system, such as tubing, not specifically covered by cleaning procedures should be degreased using a vapor phase trichloroethane degreaser. Ultrasonics may be used in conjunction with vapor phase degreasing for the cleaning of components.
( 4 ) Purging . The system should be purged with hot, dry 99.5 percent pure oxygen gas in accordance with the manufacturers recommendations after:
( i ) Initial assembly of the oxygen system; and
( i i ) After system closure whenever t he oxygen system pressures have been depleted to zero, or the system has been left open to atmospheric conditions for a period of time or is opened for repairs.
( 5 ) Maintenance and Replacement . All parts of the oxygen system should be installed to permit ready removal and replacement without the use of special tools. All tubing connections and fittings should be readily accessible for leak testing with a leak test compound formulated for leak testing oxygen systems and for tightening of fittings without removal of surrounding parts.
(ii) Gaseous Oxygen .
(A) General . This guidance is intended to supplement the existing guidance in AC 43.13-2A, Chapter 6. If there are any differences within the two AC’s, this guidance shall prevail since it pertains specifically to Part 29 requirements.
(B) System Components .
( 1 ) High Pressure Cylinders . Many installations utilize hospital type cylinders rather than aviation type cylinders. A concern with the hospital type cylinders is the yoke and the hard plastic washer that is commonly used with these cylinders. It is very difficult to properly attach these yokes since the rotorcraft provides a high vibration environment and no positive lock is provided. Leaks are a continuous problem with this configuration. Yokes are available for these bottles that provide for a positive lock.
Improved washers that provide for a good elastomeric seal and include a metal ring to limit crushing the washer are also available. If the hospital type bottles are to be used, only the modified yokes and improved seals should be considered for future installations. The preferred cylinder is the aviation type cylinder with the integral shut-off valve and regulator. All cylinders should be DOT approved.
( 2 ) Lines .
Page MG 6 - 13 ( i ) General . Any lines that pass through potential fire zones should be stainless steel.
( i i ) High Pressure . Use of high pressure lines may be necessitated by the use of a pressure regulator that is remote from the cylinder. The intent is to locate the regulator as close as physically possible to the cylinder, and to minimize the use of fittings. Lines of 6-inch lengths are encouraged with 18-inch lengths being the maximum in unusual circumstances. Lines made of stainless steel are recommended.
(iii ) Low Pressure . Although lines may only be subjected to low pressures, if they are located behind upholstery or for any reason are not 100 percent visible during normal operation, they should be solid metal lines or high pressure flexible lines such as Aeroquip 300 series hose, or Stratoflex 124, or 170 series hose assemblies. The so called “green lines” should only be used in locations that are 100 percent visible during normal operation. This would restrict their use to the run between the mask and the bulkhead disconnect in the aircraft cabin. Synthetic lines such as plastic, nylon, or rubber cannot be recommended for applications that will be exposed to continuous pressure (i.e., as opposed to pressurized when needed). These materials can cold flow.
( 3 ) Fittings .
( i ) High Pressure . Intercylinder connections are made with regular flared or flareless tube fittings with stainless steel. Usually fittings are of the same material as the lines. Mild steel or aluminum alloy fittings with stainless steel lines are discouraged.
Titanium fittings should never be used because of a possible chemical reaction and resulting fire. An example of a series of fittings that has been accepted is the “SS” series Swagelok tube fittings (flareless).
( i i ) Low Pressure . Fittings for metallic low pressure lines are flared or flareless, similar to high pressure lines. Line assemblies should be terminated with “B” nuts in a similar manner to a manufactured terminating connection. Universal adapters (AN 807) or friction nipples used in conjunction with hose clamps are not accepted for use in pressurized oxygen systems.
( 4 ) Shut-off Valve . Each system should contain a shutoff valve that is located as close as practical to the high pressure cylinder(s), and it should be assessable to a flightcrew member. High pressure cylinders should use slow opening/closing system shut-off valves. Where the regulator is part of the cylinder, and low pressure oxygen is controlled, the emphasis in slow acting valves is not as significant, and use of a flow fuse may be possible. Use of a flow fuse must be supported by a system fault analysis and testing to show maximum normal flow will not result in nuisance trips, and reliable trips will be provided for malfunction conditions resulting in excess flow.
Page MG 6 - 14 ( 5 ) Regulators . The regulator should be mounted as close as possible to the cylinders (reference b(9)(ii)(B)(2)(i)). If nonaviation qualified regulators are to be considered, their service history should be reviewed and careful consideration should be given to the manufacturer’s environmental qualification. Radio Technical Commission for Aeronautics Document D0-160 is a recognized and accepted standard for environmental considerations. As a minimum, consideration should be given to operation during altitude, temperature, and vibration extremes.
( 6 ) Placards . Appropriate placards should be provided with the installed system. Emphasis should be placed on any precautions that are appropriate during filling of the system and so forth.
( 7 ) Filler Connections . When a filler connection is provided, it is recommended it be located outside the fuselage skin or isolated in a manner that would prevent leaking oxygen from entering the rotorcraft. Careful evaluation should also be made of any nearby sources of fuel, oil, or hydraulic fluid under normal or malfunction conditions. Each filler connection should be placarded. In addition, any valves (on aircraft or ground servicing equipment) associated with high pressure should be slow acting.
(C) “Provisions Only” Considerations . In some instances systems are approved that only include provisions for a supply system consisting of the high pressure cylinders, regulators, and their associated lines and fittings. In these instances, a placard should be provided that refers to a supply system that is considered satisfactory for the remainder of the installation. Other supply system configurations may very well be acceptable; however, they should be evaluated by the ACO that evaluated the original installation. An example of an acceptable placard for this situation is:
Oxygen Supply System must be in accordance with the requirements given in STC SH _________. Deviations to the configuration specified must be evaluated and approved by the Manager (include reference to the appropriate FAA ACO).
(11) Medical Communication Equipment . This equipment is provided to allow for communication between the rotorcraft and ground medical personnel. It includes voice communication and may also include telemetry equipment for the transmission of graphic data. It should be demonstrated that this equipment functions, and the range at which this determination was made should be recorded in the project file. The functional demonstration should include a 360° turn (clockwise and counterclockwise) to assure no significant sections of signal blanking exists. The remainder of the emphasis on this equipment should be to assure that operation of this equipment does not interfere with normal operation of any avionic systems whose installation is required for safe operation of the rotorcraft.
Page MG 6 - 15
(12) Cabin Lighting . EMS interiors normally include higher intensity cabin lighting than other interiors. This lighting capability should be carefully evaluated to ensure it does not interfere with operation of the rotorcraft. In some installations a special curtain is required to separate the cockpit from any interference by the lighting.
The FAA/AUTHORITY project file should include a short discussion of how this evaluation was conducted. See paragraph b(6) for other curtain considerations.
(13) Other EMS Equipment . These items of equipment that are installed for the EMS mission are considered to be optional equipment and should be operated to assure they function properly. This evaluation would normally be done by someone that is knowledgeable about the particular type of equipment since correct operation of the equipment is essential to a valid determination that the required rotorcraft systems are not being interfered with. This includes all removable pieces of medical equipment that are used for patient care. The primary purpose of the evaluation of this equipment is to emphasize the possibility of any adverse interference between operation of the EMS equipment and the systems whose installation is required for safe operation of the aircraft, the adequacy of the installation provisions, and assurance that failure modes will not result in a hazardous condition for the rotorcraft.
(14) Miscellaneous . The following areas are not peculiar to EMS installations;
however, their significance is enhanced by the complexity of an EMS installation.
(i) Compatibility . Many EMS installations are a collection of several STC’s and may also include some “FAA/AUTHORITY field approvals.” For this situation it should be shown that the overall installation provides for safe operation of the aircraft.
Operation of a search light, if included, should be emphasized since this system can be difficult to keep out of the cockpit.
(ii) Electrical Load Analysis . An electrical load analysis should be conducted, and additional guidance is available in paragraph AC 29 MG 1. If the analysis indicates the generator(s) can be overloaded, appropriate measures should be taken to account for the problem. In some instances a placard that specifies certain operating limitations may be satisfactory while in other instances an electrical interlock may be in order. In general, if the amount of overload is relatively small, the placard solution will probably be satisfactory; whereas if the amount of possible overload is significant, it is more likely that an interlock scheme will be necessary.
(iii) Aircraft Grounding . It should be emphasized in an appropriate place in the STC data (RFM, maintenance information, etc.) that any time the EMS systems are being operated or serviced (oxygen for example) on the ground, the rotorcraft itself must be grounded.
(iv) Electrical Outlets . All electrical outlets provided in the cabin should be the three-prong grounded type. When not in use, these outlets should be suitably protected against the entry of fluids.
Page MG 6 - 16
(v) Placards . All medical outlets should be placarded (air, oxygen, vacuum, etc.). Electrical power outlets should be placarded for type of voltage and amperage capacity. A placard stating no smoking when oxygen is in use should be included. Other placards would include information appropriate to the oxygen system, operation of special controls, etc.
(vi) Equipment in Ca rgo and Baggage Compartments. When components are added to the compartment, revisions should be made to protect the system components due to shifting cargo. In addition, when oxygen components are installed, the compartment should be placarded against the storage of oil or hydrocarbons. A smoke detector is recommended for a compartment if oxygen cylinders are installed in a closed, nonaccessible compartment. Also, the compartment weight limitations placard should be changed. Paragraph AC 29.787 pertains to cargo and baggage compartments.
(15) Equipment Substitution . The EMS modification that is presented for approval will contain specific items of equipment, and the approval will make reference to this equipment. If other equipment (new model, manufacturer, etc.) is to be substituted, then an evaluation should be made to assure the substitute equipment is also satisfactory. This evaluation would normally consist of comparing the attachment means, design features, failure modes, specifications, and operation of the two units.
The purpose of the evaluation is to assure there are not differences that have an adverse effect on the airworthiness of the installation. Other differences would not be considered significant. A specific seat and litter design is approved as a part of the EMS configuration. Substitutions may be approved in accordance with the standards.
c. Related FAR Se ctions and References.
(1) FAR Sections . §§ 29.337, 29.471, 29.561, 29.773, 29.783, 29.785, 29.803,
29.805, 29.809, 29.811, 29.813, 29.815, 29.831, 29.853, 29.1301, 29.1309, 29.1353,
29.1357, 29.1411, 29.1431, 29.1557(d), 29.1583(d), 29.1585, and 29.1589.
(2) Other References .
(i) Helicopter Association Inte rnational, Emergency Medical Services Recommended Guidelines, 1987, First Revision, 2 pages.
(ii) National Highway Traffic Safety Administration, Air Ambulance Guidelines, dated 1981.
(iii) FAR Part 91, General Operating and Flight Rules.
(iv) FAR Part 135, Air Taxi Operators and Commercial Operators.
(v) AC 67-1, Medical Informati on for Air Ambulance Operators, dated March 4, 1974.
Page MG 6 - 17
(vi) AC 23-2, Flammabilit y Tests, dated August 20, 1984.
(vii) Oxygen Equipment for Aircra ft, Society of Automotive Engineers Aerospace Information Report No. 825B, Rev. 9/86.
(viii) Acceptable Methods, Techniqu es, and Practices--Aircraft Alterations, AC 43.13-2A, dated June 9, 1977.
(ix) Design and Installation of Li quid Oxygen Systems in Aircraft, General Specification for Military Specification MIL-D-19326G, dated October 1, 1985.
| BUILDUP/VENT VALVE I FILL ¡VALVE INTEGRAL ASSEMBLY (Most Cases) TO GAUGING SYSTEM LIQUID CONTAINER CHECK - VALVE FIGURE AC 29.MG 6-1 TYPICAL LIQUID OXYGEN SYSTEM PRESSURE RELIEF PRES. CLOSING VALVE PRES. BUILDUP COIL EMERGENCY SHUTOFF VALVE
EVAPO- RATING COIL ASSEMBLY
OVERBOARD VENT LINE PRESSURE RELIEF - REGULATOR
TO PATIENT Page MG 6 - 18
FILL, BUILDUP AND VENT VALVE CHECK VALVE _ _ FIGURE AC 29 MG6-2 TYPICAL LIQUID OXYGEN SYSTEM - USING COMBINATION VALVE INTEGRAL ASSEMBLY (Most Cases) TO GAUGING SYSTEM LIQUID CONTAINER
PRESSURE RELIEF PRES CLOSING VALVE PRES BUILDUP COIL EMERGENCY SHUTOFF VALVE
EVAPO- RATING COIL ASSEMBLY
OVERBOARD VENT LINE PRESSURE RELIEF REGULATOR
FLOW CONTROL VALVE Page MG 6 - 19
AC 29-2C, Chg 1 2/12/03 Page MG 6 - 20
INTENTIONALLY LEFT BLANK
CHAPTER 3
AIRWORTHINESS STANDARDS
TRANSPORT CATEGORY ROTORCRAFT
MISCELLANEOUS GUIDANCE (MG)
AC 29 MG 7. STRUCTURAL CONDITION INDICATORS.
a. Related Sections. § 29.301 - Loads; § 29.305 - Strength and Deformation;
§ 29.571 - Fatigue Evaluation of Flight Structure; § 29.1301 - Function and Installation;
§ 29.1309 - Equipment, Systems and Installations; § 29.1321 - Arrangement and Visibility; § 29.1322 - Warning, Caution, and Advisory Lights; § 29.1355 - Distribution System; § 29.1503 - Airspeed Limitations: General; and § 29.1529 - Instructions for Continued Airworthiness.
b. Background.
(1) Structural condition indicators have been used on rotorcraft for several years in two main programs: as part of the basic type design and as part of airworthiness directive (AD) action. When approved as part of the basic type design, only limited “credit” has been given for the installation of structural condition indicators;
i.e., components provided with a structural condition indication system were required to be designed to § 29.571 “safe-life” criteria considering the structural condition indicator system inoperative. So-called “nonhazard” approvals were granted. When used as part of the mandatory actions of ADs, structural condition indicators have had a degree of “credit” recognized, primarily in the recognition of “fail-safety” provided by the indicator system.
(2) Since structural condition indica tors have been used during both original type design and AD issuance, and since there is movement toward increased damage tolerance in rotorcraft design, policy concerning condition indicator use is considered appropriate.
c. At present, the use of structural condition indicators alone on new type designs is not considered an acceptable substitute for providing the necessary safe life for each component. However, areas which may be considered when approving these indicators for fail-safety credit are delineated in the following paragraphs.
d. What, how, when, where, and who of structural condition indicators.
(1) Indication of what?
(i) Previous structural conditi on indicators have primarily been used for crack detection. Several types of through-the-thickness crack detection systems are currently in use. Two types which detect changes in pressure in an instrumented chamber due to gas movement through a cracked wall are known as the blade Page MG 7 - 1
inspection method (BIM) system and the integral spar inspection system (ISIS). These systems can only detect full-depth cracks which are large enough to allow loss (of gain) of pressure from the instrumented chamber. This presents a limitation since full-depth cracks may be fast growing before detection. Another through-the-thickness crack method is a pressurized, dyed fluid or oil system to detect through cracks in specially designed bolts (NASA patent), spindles, pins, or other closed chamber mechanical equipment.
(ii) Surface cracks can be found by systems such as surface-mounted crack detection wires. These systems would allow a greater safe crack growth period for assuring safe landing after detection than the through-crack-detection systems, but they have been used little in operations because of significant limitations; e.g., complexity of installation, durability problems, limited areas of coverage, and strain level limitations.
(iii) Some aircraft have had mast moment indicators or other load indicators to help prevent the pilot from inadvertently applying a high load to the instrumented system or to help the pilot reduce the load by control movements. These load indicators only indirectly give indications of structural condition; therefore, only limited “credit” is allowed for this use. “Credit” is limited in that the fatigue life substantiations of § 29.571 should consider a reasonable number of excursions into the higher ranges established for the load indicator, and special inspections, rework, or replacement instructions should be provided for any strength degradation associated with high range excursions.
(2) How indicated?
(i) Current BIM systems use two types of indicators. The visual blade inspection method (VBIM) uses a gauge mounted on the blade which must be read visually by maintenance personnel while the aircraft is parked. The cockpit blade inspection method (CBIM) uses lights mounted in the cockpit which may be monitored by the crew. Other pressurized chambers have used dyes or oils to improve visual inspection effectiveness. Mast moment indicators and other load indicators use instruments with marked ranges and needles.
(ii) No specific types of load indicators are required by the FAA/AUTHORITY but the type used should be evaluated for accuracy, readability, and overall effectiveness. Paragraphs AC 29 MG 7(e) and (f) cover, in more detail, the use of structural condition indicators.
(3) When indicated? Structural condition indicators are used before flight, during flight, and for normal maintenance inspections. Paragraphs AC 29 MG 7 (e) and
(f) contain guidance for cockpit-mounted instruments which are monitored during flight.
Indicators used for normal maintenance inspections are the preferred type since they can be scheduled to allow the most effective use of available maintenance personnel of well-equipped maintenance facilities and of parts available.
Page MG 7 - 2