N12145
Service difficulty reports · 49
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N12145' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N12145' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR JJBA20260520024Hose · cut#1 HYD LOW QTY FOLLOWED BY HYD SYSTEM 1 FAIL ON CLIMB OUT. #1 HYD LOW QTY MESSAGE CAME ON DURING CLIMB OUT OF IAH/ QTY WAS SHOWING AMBER. SAW THE CARROTS WERE SLOWLY MOVING DOWN THEN LOST SYSTEM 1 HYD PRESSURE AND THEN #1 HYD SYSTEM FAILURE MESSAGE APPEARED. SDR JJBA20260501033Battery Pack · inoperativeEXTERIOR EMERGENCY LIGHT - WING FUSELAGE FRONT FAIRING LT - INOPERATIVE. REMOVED AND REPLACED BATTERY POWER SUPPLY #1. OPS CHECK SAT. NO FURTHER DEFECTS NOTED.SDR JJBA20251224030Battery Pack · inoperativeNUMBER 4 EMERGENCY LIGHT BATTERY INOPERATIVE. REMOVED AND REPLACED THE NR 4 EMERGENCY LIGHT BATTERY PACK. OPS CHECK GOOD.SDR JJBA20251208015Battery Pack · inoperativeINTERIOR EXIT ROW EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED BPS #3. OPS CHECK SAT.SDR JJBA20231120012Pump · inoperativeHYD SYS 1 FAIL. FOUND ENGINE DRIVEN PUMP AT FAULT, REMOVED AND INSPECTED PRESSURE AND CASE DRAIN FILTERS. OPS AND LEAK CHECK SAT. NO DEFECTS NOTED. REMOVED AND REPLACED ENGINE DRIVEN PUMP #1. REMOVED AND REPLACED E1 HYD EDP DUE TO LEAKS FOUND AFTER OPS CHECK. SDR JJBA20230717018Module · inoperativeEMERGENCY LIGHT WILL NOT EXTINGUISH. REMOVED AND REPLACED ICU PANEL. OPS CHECK SAT.SDR JJBA20210207018Not Reported · not reportedCNTR OMEGA BEAM - FR 46 THRU FR 53 BL "0" I/B LWR FLANGE - HAS CORROSION MULTIPLE LOCATIONS. REMOVED AND REPLACED CENTER OMEGA BEAM AT FRAME 46 THRU FR 53SDR JJBA20220207017Not Reported · not reportedLH OMEGA BEAM FR 38 + 5 THRU FR 46 I/B LWR FLANGE HAS CORROSION MULTIPLE LOCATIONS. REMOVED AND REPLACED LH OMEGA BEAM AT FRAME 38 + 5 TO FRAME 46SDR JJBA20210808026Relay · failedSMOKE IN THE GALLEY AND BEHIND THE F/O SEAT ON SHORT FINAL. FOUND RELAYS K0055, AND K0054 AND THEIR SOCKETS TO BE DAMAGED. ALSO, NOTED DAMAGE TO WIRES GOING TO BOTH SOCKETS. R&R RELAYS K0055 AND K0054 AND THEIR CORRESPONDING SOCKETS. REPAIRED CORRESPONDING WIRSDR JJBA20210704005Light · inoperativeSERVICE DOOR EXTERNAL EMERGENCY LIGHT INOPERATIVE. R&R SERVICE DOOR EXTERNAL EMERGENCY LIGHT. OPS CHECK SAT.SDR JJBA20210311036Doubler · not reportedRH ELEVATOR REPAIR DOUBLER FOUND ON HORN UPPER SKIN BTW RIB YH 3222-8233 AND BTW L/E & SPAR 73.0%. REPAIR DOUBLER REWORKED.SDR RAIA2019021340003Tee Fitting · corrodedAFT CARGO BAY DOOR CUTOUT FWD T CLIP HAS CORROSION. REMOVED AND REPLACED CARGO BAY DOOR CUTOUT FWD T CLIPSDR RAIA2019021300001Angle · corrodedAFT CARGO BAY DOOR CUTOUT Z ANGLE HAS CORROSION. REMOVED AND REPLACED AFT CARGO BAY DOOR CUTOUT Z ANGLESDR RAIA201902040001Door Sill · corrodedSERVICE DOOR AFT SILL AT FRAME 22 HAS CORROSION. REMOVED CORRODED SECTION FABRICATED DOUBLER AND INSTALLED AT FRAME 22.SDR RAIA201902010003Gusset · corrodedLT LAV FLOOR GUSSET AT FRAME 61 HAS SURFACE CORROSION. REMOVED AND REPLACED LT LAV FLOOR GUSSET AT FRAME 61.SDR RAIA201902010002Gusset · corrodedMID LAV FLOOR GUSSET AT FRAME 61 HAS SURFACE CORROSION. REMOVED AND REPLACED MID LAV FLOOR GUSSET AT FRAME 61.SDR RAIA201810100003Clamp · looseBLEED 2 LEAK. R2 ENGINE BLEED VALVE AND BOTH CLAMPS. TIGHTENED CLAMP JUST AFT OF NR 2 PRECOOLER AND ADJUSTED PNEUMATIC DUCTS. PERFORMED OPS/LEAK TEST. NO DEFECTS/MSGS NOTED AT THIS TIME.SDR RAIA201808270001Clamp · unsecureBLEED 2 LEAK AT 20,000 FT IN ICING CONDITIONS. CHECKED SECURITY OF ALL BLEED 2 COUPLINGS. NO FURTHER LEAKS NOTED AT JOINTS 18, 20, 22, OR 24. SECURED 3 CLAMPS IN #2 PYLON AND REPLACED SEAL AT LOCATION 8. PERFORMED BLEED OPS CHECK WITH CREW.SDR RAIA201803250001Support · out of adjustMAIN CABIN DOOR WILL NOT CLOSE FROM THE INSIDE. ADJUSTED FWD UPPER ROLLER SUPPORT. OPSC CHECK GOOD AT THIS TIME.SDR RAIA201610230001Light · wornEMERGENCY LIGHT STRIP WORN BY 1A. R & R THE EMERGENCY LIGHT STRIP.SDR RAIA201609290001Armrest · damagedINBOARD ARMREST WILL NOT LOCK AT 18A. INBOARD ARMREST AT 18A PLACED ON DMI# 7009152 ON LOG PAGE 156769, ON 09/24/16. ON 09/25/16: R & R INBOARD ARMREST AT 18A, OPS CHK GOOD. CLEARED DMI# 7009152 ON LOG PAGE 156771,ON 09/25/16SDR RAIA20160304001Lamp · inoperativeEMERGENCY LIGHT LT FWD WING TO FUSELAGE FAIRING EC, EXTERIOR FLOOD LIGHT NR 3 INOPERATIVE. REPLACED THE LAMP EXTERIOR EMERGENCY FLOOD LIGHT NR 3. OPS CHECK GOOD.SDR RAIA201601250002Flashlight · inoperativeF/A FLASHLIGHT WILL NOT CHARGE. R & R THE FLASHLIGHT. OPS CHECK GOOD.SDR ASOA20140829074Mount · crackedDURING ROUTINE MAINTENANCE 5A INSPECTION, THE NR 1 ENGINE LOWER FORWARD MOUNT YOKE FITTING WAS FOUND CRACKED. MAINTENANCE REPLACED THE YOKE FITTING IAW SB 145-54-0013 AND ETD 2014-145-073164.SDR ASOA20130819097Bulb · inoperativeDURING MX INSPECTION THE AFT OVERWING EMERGENCY EXIT LIGHT WAS FOUND INOPERATIVE. R & R BULB, OPS CHECKED SUCCESSFUL. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20130719189Frame · corrodedDURING C-CHECK THE PAX DOOR LOWER FRAME WAS FOUND TO BE CORRODED AROUND THE NUTPLATE HOLES FOR THE DOOR LINER FASTENERS. MX REMOVED THE CORROSION AND PERFORMED A DOUBLER REPAIR IAW EC5210-01154. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20130719188Yoke · crackedDURING C-CHECK THE RT ENGINE FWD LOWER MOUNT YOKE WAS FOUND TO BE CRACKED AND VERIFIED WITH EDDY CURRENT. MX R & R THE YOKE IAW EC5450-01073. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20130706183Floor Support · corrodedDURING C-CHECK THE LT OMEGA BEAM WAS FOUND TO BE CORRODED AT FRAME 20. MX REMOVED THE CORROSION AND PERFORMED A DOUBLER REPAIR IAW SRM 53-00-10. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20130204008CUnknown · smokeTHE CREW REPORTED AT 800 FT. SMOKE BEGAN BILLOWING INTO THE COCKPIT AND CABIN THEN HAD APU FAIL MESSAGE. MX INSPECTED AND NOTICED STRONG ODOR OF DEICE FLUID WHEN RUNNING BLEED SYS. ODOR DISAPPATED WITHIN 15-20 MINUTES WITH PACKS ON AND DID NOT RETURN. ENGISDR ASOA20120804067CTire · failedTHE CREW REPORTED NR 3 TIRE BLEW ON TAKEOFF. PERFORMED EMERGENCY LANDING. MX REPLACED THE NR 3 AND NR 4 MAIN WHEEL ASSEMBLIES. THE ACFT WAS RELEASED FOR SERVICE.SDR C2XA11RI158Shock Absorber · defectiveFLT 2494 EWR-MCI CREW REPORTED 3 BANGS DURING GEAR RETRACTION AFTER TAKEOFF. CREW PERFORMED AIR RETURN BACK TO EWR UNEVENTFULLY. EWR MX REMOVED AND REPLACED THE RIGHT MAIN GEAR STRUT SHOCK ABSORBER AND SERVICED IAW EMB145 AMM 32-10-02 AND EC3210-01184. ACFTSDR C2XA11CL214Control Unit · malfunctionedCLE FLT 2354 THE CREW REPORTED A BANGING NOISE DURING GEAR RETRACTION. THE CREW SEEMED TO THINK IT WAS ASSOCIATED WITH THE WHEELS SPINNING. THE AIRCRAFT RETURNED TO CLE AND LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED AND REPLACED THE BRAKE CONTROL UNIT. SDR C2XA11CL173Warning System · malfunctionedCLE FLT 2250 THE CREW REPORTED AN APU FIRE DETECT FAIL MESSAGE ON THE EICAS DURING TAXI. THE AIRCRAFT RETURNED TO THE GATE. MAINTENANCE INSPECTED PLACED THE APU FIRE DETECT SYSTEM AND THE APU ON MEL. SUPPLEMENT TO FOLLOW.SDR C2XA11TY115Inverter · inoperativeEMERGENCY LIGHT INVERTER NR 4 INOP. REMOVED AND REPLACED NR 4 INVERTER IAW EMB 145XR AMM33-50-11, OPS CHECK GOOD.SDR C2XA11RI050Solenoid Valve · inoperativeFLIGHT 2909 - DCA - FLIGHT CREW REPORTED THAT UPON GEAR RETRACTION WIND NOISE HEARD FROM NOSE AREA. EWR MX REMOVED AND REPLACED NOSE GEAR DOOR SOLENOID VALVE AND PERFORMED OPERATIONAL CHECK SUCCESSSFULLY. ACFT WAS APPROVED TO RETURN TO SERVICE.SDR C2XA11CL036Pressure Switch · faultyIAH - FLT 2548 THE CREW REPORTED A NR 1 ENGINE LOW OIL PRESSURE WARNING IN FLIGHT. THE AIRCRAFT DIVERTED INTO CLE AND LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED AND REPLACED THE NR 1 ENGINE LOW OIL PRESSURE SWITCH. OPERATIONAL CHECKS WERE GOOD.SDR C2XA10SH091Skin · crackedSHV - DURING C-CHECK FUSELAGE SKIN HAS CRACKS AROUND RIVETS AT FR 79 ON RT SIDE. REPAIRED SKIN IAW EC5310-02080. AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA10SH090Floor Support · corrodedSHV - DURING C-CHECK LT OMEGA BEAM HAS CORROSION BETWEEN FR 23-30. REPAIRED OMEGA BEAM IAW EMB 145 SRM 53-00-10. AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA10SH088Floor Support · corrodedSHV - DURING C-CHECK RT OMEGA BEAM BETWEEN FRAME 60-61 HAS CORROSION (LEVEL 2 LOCAL) AT NUT PLATE HOLE. MAINTENANCE PERFORMED REPAIR ON RT OMEGA BEAM BETWEEN FRAME 60-61 AT NUT PLATE HOLE IAW EC5310-01473. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA10SH087Floor Support · corrodedSHV - DURING C-CHECK CENTER OMEGA BEAM HAS CORROSION (LEVEL 2 LOCAL) FRAME 20. MAINTENANCE REMOVED AND REPLACED CENTER OMEGA BEAM BETWEEN FRAMES 16-24 IAW EMB-145 SRM 51-40-02. THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA10RI018Display · malfunctionedFLIGHT 2899 - EWR - FLIGHT CREW REPORTED EICAS WENT BLANK IN FLIGHT, ACCOMPANIED BY ELECTRICAL ODOR. EWR MX REMOVED AND REPLACED EICAS DISPLAY UNIT AND PERFORMED OPERATIONAL CHECK SUCCESSFULLY. ACFT WAS APPROVED TO RETURN TO SERVICE.SDR C2XA09CL045Engine · malfunctionedMAINTENANCE REPORTED HAZE AND SMOKE DURING ENGINE RUNS OF THE NR 1 ENGINE WITH THE LEFT OR RIGHT COOLING PACKS ON. THE ENGINE WAS REPLACED AND OPERATIONAL CHECKS WERE GOOD. SUPPLEMENT TO FOLLOW.SDR C2XA08IA188Proximity Sensor · inoperativeIAH - FLIGHT 2352 - CREW REPORTED, AFTER TAKEOFF THE LANDING GEAR DID NOT INITIALLY RETRACT, AND HAD THE ASSOCIATED DISAGREE MESSAGE ON EICAS. THE ACFT LANDED AT IAH WITHOUT INCIDENT WHERE MAINTENANCE REMOVED AND REPLACED THE TRAILING ARM PROXIMITY SENSOR. OSDR C2XA08IA187Control Handle · inoperativeIAH-FLIGHT 2352 - THE CREW REPORTED THAT AFTER TAKEOFF THE LANDING GEAR DID NOT INITIALLY RETRACT, AND HAD THE ASSOCIATED DISAGREE MESSAGE ON EICAS. THE ACFT LANDED AT IAH WITHOUT INCIDENT WHERE MAINTENANCE REMOVED AND REPLACED THE LANDING GEAR LEVER. OPERATSDR C2XA06TY069Sill · corrodedAIRCRAFT IN FOR 2C CHECK 602 058223 - BAGGAGE DOOR SILL FWD EDGE CORRODED. REMOVED AND REPLACED LOWER SILL IAW EMB145 SRM 51-40-02 AND AMM 21-31-00.SDR C2XA06TY063Hinge · wornTYS DURING A 2C INSPECTION THE RT VERTICAL STAB SPHERICAL BEARING WAS FOUND TO BE OUT OF LIMITS. MAINTENANCE REAMED THE HOLE TO THE FIRST OVERSIZE IAW EC 5510-01080. ALL WORK WAS ACCOMPLISHED AND WILL BE RELEASED UPON COMPLETION OF ALL 2C WORK.SDR C2XA06IA084Power Supply · dischargedIAH - FLIGHT 3170, DURING PRE-FLIGHT INSPECTION, THE CREW REPORTED THE EMERGENCY EXIT LIGHT ABOVE ROW 12 TO BE INOPERATIVE. MAINTENANCE INSPECTED THE AIRCRAFT, REMOVED AND REPLACED THE AFFECTED EMERGENCY LIGHT BATTERY POWER SUPPLY, OPERATIONALLY CHECKED WITH SDR C2XA06IA083Battery Pack · activatedIAH - FLIGHT 3170, DURING PRE-FLIGHT INSPECTION, THE CREW REPORTED THE EMERGENCY EXIT LIGHT ABOVE ROW 12 TO BE INOPERATIVE. MAINTENANCE INSPECTED THE AIRCRAFT, REMOVED AND REPLACED THE AFFECTED EMERGENCY LIGHT BATTERY, OPERATIONALLY CHECKED WITH NO DEFECTS. SDR C2XA05IA115Control Valve · inoperativeIAH - FLIGHT 2955, CREW REPORTED A OILY BURNING ODOR IN THE COCKPIT AND FORWARD CABIN DURING DESCENT WITH A PAX OVERLOAD INDICATION IN AUTO. THE AIRCRAFT LANDED AT IAH WITHOUT INCIDENT WHERE MAINTENANCE PLACED THE PAX SYSTEM ON MEL 21-30-00/1 CAT C CONTORL NU
Back to N12145