N1399A
Service difficulty reports · 343
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1399A' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1399A' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2021062201402Start Valve · faultedEICAS MESSAGE L START VALVE CUTOUT(<P>REMOVED AND REPLACED ENGINE #1 START VALVE IAW B767 AMM 80-11-02. OPS CHECK NORMAL AT THIS TIME. NO MESSAGES PRESENT AT THIS TIME. </P>)SDR UIEA2021062101389Relay · faultedENG #1 START SELECTOR WILL NOT STAY IN GND DURING ENGINE START.(<P>TRANSFERRED TO FLIGHT CREW DEFERRAL MEL #148761, DDG 80-11-02, CAT "C", 27JUN21 TJ M1755Z.</P> / <P>ONT - 23JUN21- LP 1478315 ITEM 10 - REF LP 1478314 ITEM M9, RELAY (K1173) REMOVED AND REPLACESDR UIEA2021062101391Relay · faultedENG #1 START VALVE INOP(<P>TRANSFERRED TO FLIGHT CREW DEFERRAL MEL # 148762, DDG 80-00-02-01 CAT "C", 27JUN21 TJ 1801Z. REMOVED AND REPLACED ENG START RELAY K1173 PER WDM 80-11-11. PERF ENG RUN PER AMM 71-00-00 FOR L ENG. START STAYS ON GND AND 50% CLICKS BASDR UIEA2021061601363Warning Message · false activationSTATUS MSG R ENG SPEED CARD(<P>PERF FIM 73-21 FT 871. CLEARED MSG. TEST CHANNEL 1 AND 2. MSG DISPLAYS. SYSTEM TEST OK</P>)SDR UIEA2021061501354Igniter · faultedRT ENG IGNITOR 2 EICAS MSG ( IGNITION SYSTEMS, ER OPERATIONS ALLOWED )(<P><SPAN>TRANSFERRED TO MEL 74-00-01A, MDDR 148600.</SPAN></P> / <P>ONT-15 JUN - LP 1386635 - ITEM 6 - REMOVED AND REPLACED RIGHT HAND ENGINE IGNITOR PLUG IAW AMM 74-21-02. OPS CHECKS GOOD.SDR UIEA2021061301340Warning Message · false activationIN DESCENT THROUGH FL350 STATUS MSG: R ENG SPEED CARD. PERFORMED T/S IAW FIM 73-21 FAULT TREE 871 AND FIM 31-41-00/101. NO FAULTS NOTED, SYSTEM IS OK.SDR UIEA2021061401348Warning Message · false activationSTATUS MSG AFT EQ EXH FAN 2(<P>PERFORMED OPS CHECK IAW AMM 21-58-00, OPS CHECK GOOD. FIM TASK 21-58 TASK 805 STATES SHORT TEMPORARY INTERRUPTIONS LIKE THE ONE THAT OCCUR DURING A POWER TRANSFER (GROUND-APU-ENGINE APU-GROUND) CAN CAUSE THE EICAS MESSAGE.</P>)SDR UIEA2021060901303Connector · damagedAPU AUTO SHUTDOWN APPROX 30 MIN AFTER START, APU FAULT MESSAGE. TROUBLESHOT PER B767 FIM 49-11 TREE 909 GEN FILTER MSG ON ECU - APU INOP - ITEM PLACED ON DMI 148253 IAW MEL 49-11-01A, CAT C, DUE 19 JUN21. C/W AP-20109, PERFORMED AMM 49-20-00 GVI TASK NO FAULSDR UIEA2021060601275Pin · recessedAPU AUTO SHUT DOWN.(<P>PERFORMED APU CONTROL UNIT BITE TEST., FAULT CODE GEN FILTER ON BITE, REQUIRES FURTHER T/S. LOG 1485729 ITEM #9: FOUND CONNECTOR P20 PIN 2 RECESSED, PERFORMED FIM 49-11 F/T 998 FOR APU AUTO SHUT DOWN, FOUND RECESSED PIN ON CONNECTOR P20 SDR UIEA2021052101163Apu · faultedAPU PNEUMATIC FUNCTION INOP ( AUXILIARY POWER UNIT, PNEUMATIC FUNCTION )(<P>TRANSFERED TO MDDR 147249 IAW MEL 49-11-01-01, CAT C, DUE 30MAY21.</P><P>LOG PAGE 1341621: REMOVED AND REPLACED APU IAW WORK CARD A-49-999-00-01. THIS CLEARS MDDR 147249.</P><P><BR />SDR UIEA2021051801144Warning Message · false activationSTATUS MESSSAGE - CARGO A/C TEMP.(<P>PERFORM SYSTEM BITE CHECK OF THE AIR SUPPLY CONTROL SYSTEM IAW AMM 26-23-00. OPS CHECK GOOD, NO FURTHER DEFECTS NOTED BY MX. STATUS MSG NO LONGER APPEARS.</P>)SDR UIEA2021051101118Fire Detector · faultedR ENG FIRE LOOP 1 STATUS MESSAGE(<P>TRANSFERRED TO MDDR# 146763 IAW MEL 26-11-01-01 CAT-C DUE-20MAY21</P><P>14MAY21 - LP 1341609 - ITEM# 26 - CVG - REMOVED AND REPLACED LWR AFT FIRE DETECTOR ASSY IAW AMM 26-11-02.OPS CHECK GOOD. THIS CLEARS DMI 146763. MCC NOTSDR UIEA2021051101119Fire Loop · faultedLH ENG FIRE LOOP 1 STATUS MESSAGE(<P>TRANSFERRED TO MDDR #146764 IAW MEL 26-11-01-01 CAT-C, DUE-20MAY21</P><P>13MAY21 - LP 1341607 - ITEM# 25 - CVG - REMOVED AND REPLACED LWR AFT FIRE DECTOR ASSY ON #1 ENG IAW AMM 26-11-02. MCC NOTIFIED. PLACARDS REMOVED. THISSDR UIEA2021051101117Circuit Card · failedLEFT ENGINE FIRE LOOP 1 STATUS MESSAGE(<P>PERFORMED GVI OF FIRE LOOP 1 SYSTEM, NO DEFECTS NOTED. PERFORMED FIM 26-11 FT804 ENG FIRE DETECT BITE, TO SHEET 3 BLOCK 4. SUSPECT BAD LEFT ENG CONTROL CARD M681 FIRE LOOP 1. REMOVED AND REPLACED M681 FIRE LOOP 1 IAW ASDR UIEA2021043001028Sealant · missing#1 ENG INLET COWL ACOUSTICAL PANEL @ 6 O'CLOCK POSITION MISSING SEALANT.(<P>APPLIED SEALANT AROUND THE ACOUSTICAL LINER SEGMENT @ 6 O'CLOCK POSITION IAW 72-33-01.</P>)SDR UIEA2021042601004Stud · brokenSTATUS MESSAGE R ENG FIRE LOOP 1(<P>TRANSFERRED TO MDDR 145950 IAW MEL 26-11-01-01, CAT C.</P><P>LOG PAGE 1465432: REMOVED AND REPLACED UPPER AFT FIRE LOOP DETECTOR PER B767 AMM 26-11-02 DURING REMOVAL OF UPPER AFT FIRE LOOP FOUND BROKEN STUD ALSO TERNIBAL WIRSDR UIEA2021042200962Connector · dirtyR ENGINE FIRE LP 1 MESSAGE(<P>FORWARD TO MDDR 145720 IAW MEL 26-11-01-01, CAT C, DUE 2 MAY 21.</P><P>MIA MX, 23APR, LP 1355451, ITEM M10: ENSURED SECURITY OF TERMNALS ON RT ENG. LOOP 1 RESPONDERS, LOOP RESISTANCE WITHIN LIMITS, NO SHOTS TO GROUND OR INTERMITTESDR UIEA2021042100945Fire Loop · false activationR ENG FIRE LP 1 STATUS MESSAGE(<P>PERFORMED FIM 26-11 FT 806 UP TO FIG 106 BLOCK 3. MSG CLEARED . NO FAULTS NOTED AT THIS TIME.<BR /></P>)SDR UIEA2021041400887Warning Light · intermittentAFTER CENTER FUEL TANK IND 0 BOTH C PUMP PRESS LIGHTS FLICKERED BUT NEVER BECAME SOLID. DID NOT GET EICAS MSG EITHER OF C TANK LOW PRESS.(<P>C/W OPS CHECK OF CENTER FUEL PUMPS AUTOMATIC SHUTOFF FUNCTION IAW 28-22-00. CHECK GOOD AT THIS TIME.</P>)SDR UIEA2021041300884Antenna · faultedWXR PREDICT EICAS MSG(<P>RAN FIM FT 805, RECEIVED ANTENNA FAULT ON BOTH L & R TRANSCIEVER, CHECKED SWITCH S269 ON ANT MOUNT AND NOTED ANTENNA MOUNTING UNCOMMANDED SUSPECTED INTERNAL SHORT ON MOUNT TERMINAL. REMOVED AND REPLACED ANTENNA MOUNT IAW 34-43-05-024. SDR UIEA2021041600918Windshear Sys · malfunctionedDURING CLIMB OUT WINDSHEAR SYSTEM EICAS MESSAGE AND FO WX FAIL FLAG ON EHSI. BOTH BLANKED AFTER SWITCHING WX RADAR TO L SYSTEM. WX FAIL FLAG REAPPEARED SHORTLY AFTER. INSPECTED L WAVE GUIDE, NO DAMAGE NOTED IAW AMM 34-43-04 & 1261164 ITEM 4. SWAPPED LEFT CESDR UIEA2021041200877Warning Message · false activationSTATUS MSG CARGO A/C TEMP(<P>PERFORMED BITE CHECK OF ZONE TEMP CONT, NO FAULTS FOUND, OLD FAULT ON EICAS CLEARED PER AMM TASK 21-61-03-715-022.</P>)SDR UIEA2021040900863Connector · disconnectedWX RADAR FAILED(<P>PERFORMED WXR BITE IAW FIM 34-43 FT 805. FOUND CONNECTOR D395 DISCONNECTED. RECONNECTED CANNON PLUG IAW AMM 34-43-02. PERF OPS CHECK OF WXR. OPS TEST GOOD. NO OTHER DEFECTS NOTED. AMM 34-43-00</P>)SDR UIEA2021040900871Sensor · faultedFWD CGO BACKUP EICAS MSG DISPLAYED AFTER LANDING.(<P>PERFORMED TASK 21-28 FAULT TREE 809, FAULTED FWD CARGO DUCT SENSOR. REMOVED AND REPLACED SENSOR AMM 21-61-01.</P>)SDR UIEA2021040700847Sensor · faultedL PACK TEMP EICAS MSG DISPLAYED AFTER LANDING(<P>PERFORMED FIM 21-51 FAULT TREE 804. IDENTIFIED L MANIFOLD TEMP SENSOR FAULTY. P/N 624016-2 ON ORDER. REMOVED AND REPLACED L MANIFOLD TEMP SENSOR, OPS TEST GOOD.<BR /></P><P>07 APR 21 - LP 1145835 ITEM 6 - TPA - SDR UIEA2021040400831Warning Message · false activationEICAS MESSAGE: WINDSHEAR SYS(<P>ITEM PLACED ON MEL 34-43-01-01A DUE DATE 07APR21 CONTINGENCY LOG 142608 MCC NOTIFIED - PLACARD INSTALLED (MDDR 144833)</P><P>DATE 04 APR 21 - LP 1145830 ITEM 4 - CVG - COMPLIED WITH AP 19531 NO DEFECTS NOTED - OPS CHECKS GOOD - SDR UIEA2021040400832Control Panel · malfunctionedLEFT SYSTEM WXR FAIL(<P>DEFERRED TO DMI 144835 MEL 34-43-01 CAT D DUE DATE 2 AUG 21 PLACARD INSTALLED </P><P>04 APR 21-LP 1145832 ITEM 8 - CVG - REMOVED AND REPLACED WX PANEL IAW B767 AMM 34-43-02. OPS CHECK IAW 34-43-00. NO DEFECTS NOTED AT THIS TIME THIS CLESDR UIEA2021032900736Status Message · false activationCARGO A/C TEMP STATUS MESSAGE.(<P>PERFORMED BITE OF LEFT PACK CONTROLLER RIGHT PACK CONTROLLER AND AUX ZONE, TEMP CONTROLLER. NO FAULTS FOUND AT THIS TIME. REF AMM 21-61-00/001 AND FIM 21-61/101</P>)SDR UIEA2021032900734Transceiver · failedLEFT WX RADAR FAILED(<P>TRANSFERRED TO MDDR # 144409 IAW MEL 34-43-01, CAT D, PLACARDS INSTALLED. DUE 24JUL21 JT @ 2112Z</P><P>LP 1456726: PERFORMED FIM 34-43 FAULT TREE 805. NO FAULTS FOUND. PERFORMED WEATHER TEST 34-33-00-735-033-002, NO FAULTS FOUND. REMOVESDR UIEA2021032400704Radar · malfunctionedLEFT WEATHER RADAR FAIL(<P>PERFORMED WEATHER RADAR SYSTEM OPERATIONAL TEST REF B767 AMM 34-43-00-715-026-002. OPERATIONAL TEST PASSED/NORMAL AT THIS TIME.</P>)SDR UIEA2021031900619Radar · intermittentWXR FAIL MESSAGE ON HSI FOR L+R WXR SYS. R SIDE SEEMS INTERMITTENT. WXR SYS STATUS MESSAGE DISPLAYED BOTH PILOTS IN TERRAIN ON CLIMB, MSG RECEIVED ON CLIMBOUT.(<P>PERFORMED L+R OPERATIONAL CHECK OF WEATHER RADAR SYSTEM PER AMM 34-43-00. OPS CHECK OKAY AT THIS SDR UIEA2021031800616Warning Flag · false activationWXR SYS STATUS MSG AND WX FAIL FLAG ON EHSI(<P>RAN FIM 34-43 TASK 801, CLEARED EICAS MSG. ALSO RAN 34-22-FAULT TREE 808. NO DEFECTS NOTED. <BR /></P>)SDR UIEA2021022200395Light · no indicationAFTER ENGINE SHUTDOWN PRESS LIGHT WOULD NOT ILLUMINATE IN R AFT FUEL PUMP SWITCH WITH SWITCH OFF. LIGHTS TEST GOOD. CYCLED AFT FUEL PUMP SWITCH, OPS CHKS GOOD PER AMM 28-40-00.SDR UIEA2021022200401Controller · faultedSTATUS MSG "CARGO A/C TEMP"(TS IAW FIM 21-28 FAULT TREE 809. FOUND PACK FLOW CONTROLLER TO BE AT FAULT. REMOVED AND REPLACED PACK FLOW CONTROLLER IAW AMM 21-51-24. OPS GOOD.)SDR UIEA2021022200402Priority Valve · faultedSTATUS MSG "R ENG PRV"(IAW FIM 36-10-00. FOUND THE PRV TO BE AT FAULT. REMOVED AND REPLACED RT ENGINE PRV IAW AMM 36-11-18. OPS TEST GOOD. STATUS MESSAGE CLEARED.)SDR UIEA2021022200394Status Message · false activationCARGO A/C TEMP STATUS MESSAGE DISPLAYED AFTER TAKEOFF. (T/S IAW FIM 21-61-00, NO FAULTS FOUND. OPS GOOD. MSG CLEARED AT THIS TIME.)SDR UIEA2021021700330Status Message · false indicationSTATUS MSG "CARGO A/C TEMP". PERFORMED BITE CHECK ON ZONE TEMP CONTROLLER. NO FAULTS FOUND, OPS CHECK GOOD REF FIM 21-61-00.SDR UIEA2021021500325Status Message · false activationSTATUS MSG / CARGO A/C TEMP(<P>FAULT CLEARED PRIOR TO ARRIVAL, ACCOMPLISHED ZONE TEMP CONT OPS TEST W/APU. BITE PASSED W/NO FAULTS, TEMP CONTROL VALVES CYC NORMALLY.<BR /></P>)SDR UIEA2021020800245Seal Depressor · dentedMAIN DECK CARGO FWD LOWER SEAL DEPRESSOR HAS 1 EA DENT FOUND TO BE WITHIN LIMITS IAW SRM 53-00-15-1A-1. NO CRACKS FOUND (<P>REMOVED DAMAGED SEAL DEPRESSOR LOCATED DRILLED DEBURRED AND INSTALLED NEW SEAL DEPRESSOR AT MAIN DECK FWD LOWER CORNER MAIN CARGO DSDR UIEA2021020800247Actuator · inoperativeRIGHT ENGINE THRUST REVERSER INOP(<P>REMOVED & REPLACED #2 ENG I/B T/REV ACTUATOR PER B767 AMM 78-31-21. LEAK & OPS CHECKED, </P><P>NO DEFECTS NOTED</P>)SDR UIEA2021020800248Acoustic Liner · cracked#2 ENGINE AT 6 O'CLOCK POSITION APROX MID ACUSTIC PANEL FOUND CRACKED(<P>REMOVED & REPLACED DAMAGED ACOUSTIC LINER SEGMENT AT #2 ENG 6 O'CLOCK POSITION PER B767-300 AMM 72-33-01-004-001-H00, AMM 72-33-01-404-011-H00.</P>)SDR UIEA2021020800249Flex Line · leaking#1 ENG PNEUMATIC LINE @ HEAT EXCHANGER LOCATION "E" AS PER EO1936A088 IS LEAKING(<P>REMOVED & REPLACED PNEU. FLEX LINE AT LOCATION "E" PER M/M 20-11-00. LEAK CK GOOD, REF EO 1936A088</P>)SDR UIEA2021020800250Priority Valve · leaking#2 ENGINE PR VALVE HAS PENUMATIC LEAK AS PER EO # 1936A088(<P>REMOVED AND REPLACED #2 ENG PRV AS PER 36-11-18 LEAK CHECK GOOD. REQUIRES RUN UP. OPS CHECK. NO LEAKS NOTICED POST ENG RUN UP. OP CHECK NORMAL.</P>)SDR UIEA2021020800251Seat Belt · damagedCOCKPIT CAPT. R/H SEAT BELT TSO TAG DAMAGE(<P>REMOVED & REPLACED CAPT LAP BELT IAW 767 AMM 25-11-01. OP CHECK NORMAL</P>)SDR UIEA2021020800252Hook And Loop · unsecureCOCKPIT CAPT SEAT LIFE VEST POUCH VELCRO LOOSE(<P>REMOVED AND REPLACED LOOSE VELCRO AT CKPIT CAPT SEAT LIFE VEST POUCH PER B767-300</P><P>AMM 20-30-01-992-001</P>)SDR UIEA2021020800253Packing · leakingENG #1 PRESSURE CASE DRAIN FILTER MODULE FWD RIGID LINE LEAKING AT "B" NUT(<P>REMOVED AND REPLACED PACKING ON L ENGINE PRESS MODULE RETURN LINE UNION. RE INSTALLED UNION & RETURN LINE PER M/M 29-11-17-404-028. REQUIRES ENGINE RUN UP, LEAK CHECK.</P><P>NSDR UIEA2021020800254Engine · vibration#2 ENG VIBRATION @ RUN UP REQUIRES REMOVAL CLEAN INSPECTION LUBE REINSTALLATION OF 1ST STAGE BLADES(<P>PERFORMED REMOVED, RELUBE & RE INSTALLATION OF FAN BLADES @ #2 ENG IAW 767 AMM 72-31-02.</P><P>PERFORMED VIB SURVEY IAW 71-00-00 TEST # 6 VIB @ .9 UNITS,SDR UIEA2021020100171Radar · fault messageWEATHER RADAR FAILED ON LT AND RT AUTO AND MANUAL MODES. WX FAIL MESSAGE ON BOTH NAV DISPLAYS. PERFORMED WX RADAR OPS TEST LT & RT PER AMM TASK 34-43-00-715-001-001. OPS CHECK GOOD AT THIS TIME. 29JAN21 LOG PG 1272422 ITM 3 PDX. PERFORMED WX RADAR OPS TESSDR UIEA2021012600125Control Panel · inoperativeWX RADAR AUTO TILT INOPERABLE. TRANSFERRED TO MDDR 34-43-01-04, CAT "C". DUE DATE: 04FEB21 DMI 141412. REMOVED AND REPLACED WEATHER RADAR CONTROL PANEL. PERFORMED WEATHER RADAR SYSTEM TEST, OPERATIONS CHECK GOOD. THIS CLEARS DMI 141412, REF MM 34-43-02 RKBSDR UIEA2021012600126Warning Message · false indicationCARGO A/C TEMP STATUS MESSAGE. PERFORMED OPERATIONS TEST ON ZONE TEMP CONT SYSTEM. NO DEFECTS OR FAULTS NOTED, IAW AMM 21-61-00, MESSAGE CLEARED.