N142UP
Service difficulty reports · 287
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N142UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N142UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA12171220Pressure Panel · corrodedINSPECTION TYPE:10YR, FWD CARGO COMPARTMENT AFT BULKHEAD HORIZONTAL PRESSURE DECK IS CORRODED BETWEEN FR 39 AND FR 40, BETWEEN -Y1959 TO -Y2462. ACCOMPLISHED REPAIR ON HORIZ PRESSURE DECK BETWEEN FR 39 AND FR 40 BETWEEN -Y1959 TO -Y2462 IAW EO A300-5310-45SDR IPXA2171136Floorboard · puncturedINSPECTION TYPE:10YR, BULK CARGO FLOORBOARD NR 161LF IS PUNCTURED. FABRICATED BULK CARGO FLOORBOARD NR 161LF IAW EO A300-5320-16407-E.SDR IPXA2171135Floorboard · puncturedINSPECTION TYPE:10YR, BULK CARGO FLOORBOARD NR 162HF IS PUNCTURED AND HAS EDGE DAMAGE. FABRICATED BULK CARGO FLOORBOARD NR 162HF IAW EO A300-5320-16407-E.SDR IPXA2171133Floorboard · puncturedINSPECTION TYPE:10YR, BULK CARGO FLOORBOARD NR 161HF IS PUNCTURED. FABRICATED BULK CARGO FLOORBOARD NR 161HF IAW EO A300-5320-16407-E, APPENDIX D.SDR IPXA11166845Floor Panel · crackedINSPECTION TYPE:4C, FWD CARGO COMPARTMENT FLOOR PANEL 132QG CRACKED AT LOWER SURFACE. FABRICATED NEW FLOOR PANEL 132QG IAW EO A300-5320-42721-A.SDR IPXA11166790Floor Panel · crackedINSPECTION TYPE:4C, FWD CARGO COMPT FLOOR PANEL 132RG CRACKED. REPAIRED FWD CARGO COMPT FLOOR PANEL 132RG IAW EO A300-5320-42721-A.SDR IPXA11166789Floor Panel · crackedINSPECTION TYPE:4C, FWD CARGO COMPT FLOOR PANEL 132SG CRACKED. REPAIRED FWD CARGO COMPT FLOOR PANEL 132SG IAW EO A300-5320-42721-A.SDR IPXA11166844Skin · chafedINSPECTION TYPE:4C, LT WING MID FLAP UPPER SURFACE REPAIR DOUBLER IS CHAFED AT INBD SIDE. ACCOMPLISHED REPAIR ON LT WING MID FLAP UPPER SKIN AT AT INBD SIDE IAW EO A300-5750-42863-A, DATED 05/27/11 AND STA SA EA 300-5730-01-A3141 REV I/R DATED 05/27/11.SDR IPXA11166843Skin · chafedINSPECTION TYPE:4C, LT WING MID FLAP UPPER SURFACE IS CHAFED AT REPAIR DOUBLER ON OTBD SIDE. ACCOMPLISHED REPAIR ON LT WING MID FLAP UPPER SURFACE IAW EO A300-5750-42870 AND STA-SA EA300-5730-01-A3143 REV I/R.SDR IPXA11164808Switch · inoperativeL1 DOOR SLIDE ARM LIGHT AND HORN SOUNDS CONSTANTLY. DEFERRED DOOR SLIDE IAW MEL 52-11-01-3. ASSIGNED 447256. R & R THE MAIN CABIN SLIDE TEST SWITCH (39WN) IAW ESPM 20-45-22. OPS CKS IAW MM 52-73-12-04. REMOVED PLACARD. NO REACTIVATION IAW DMP 52- 11-01-SDR IPXA1164808Warning Horn · malfunctionedL1 DOOR SLIDE ARM LIGHT AND HORN SOUNDS CONSTANTLY. DEFERRED DOOR SLIDE IAW MEL 52-11-01-3. ASSIGNED 447256. (OPEN)SDR IPXA10162157Smoke Detector · false activationSHORTLY AFTER T/O GOT AN AVIONICS SMOKE INDICATION ON THE O/H PANEL AK ALONG WITH BOTH ECAM AND CRC. DECLARED EMERGENCY AND RETURNED TO DEPARTURE NO PERCEIVABLE SMOKE ODOR IN THE COCKPIT- NEITHER VISUAL NOR BY SMELL TEST. R & R SMOKE DETECTOR 13WA REF L/P 32SDR IPXA10159337Pump · leakingLEAVING FL350 GOT GREEN HYD LOW RES QTY WARNING. DID AOM PROC THEN NOTICED QTY ABOVE RED DOT SAME. TURNED PUMPS BACK ON AND LOWERED GEAR--QTY WENT BACK INTO GREEN BAND. LEFT PUMPS ON FOR DURATION OF FLIGHT. EMERGENCY DECLARED. LANDING UNEVENTFUL. T/S IAW MM 2SDR IPXA10159015Connector · inoperativeSLIDE ARM LIGHT INOP, BUZZER OK. DEFERRED IAW MEL 52-73-01-1. WARNING BUZZER OPS CK GOOD. WARNING LIGHT INOP. RESECURED CONNECTOR ON ASPSU. OPS CHECK NORMAL REF AMM 52-73-00-5.SDR IPXA09157845Light · inoperativeINSPECTION TYPE:N/A LAV AUX LIGHT OUT. RELAMPED AND OPS CHECKED GOOD IAW A300-600 AMM 33-50-00 AND IPC 33-51-21-02.SDR IPXA09156204Lamp · inoperativeONE EMERGENCY LIGHT OVER DOOR INOP. RELAMPED IAW IPC 33-51-04-09B. OPS CHECK GOOD IAW MM 33-51-13.SDR UPS08153922Panel · crackedINSPECTION TYPE:C DURING MAINTENANCE CHECK INSP FOUND NR 1 ENGINE RT T/R INNER BARREL PANEL HAD A 0.4 INCH CRACK AT UPPER FORWARD AREA. CUT OUT AND REPAIRED DAMAGED AREA PER UPS EO A300-7830-31176-A AND SAA EA 300-7830-01-A1556.SDR UPS08153919Aileron · dentedINSPECTION TYPE:1C3C RT WING ALL SPEED AILERON UPPER T/E NUMEROUS DENTS. REPAIRED RT WING ASA UPPER T/E REF EO C-5750-31147-A AND EA 300- 5751-01-A1554.SDR UPS08153886Doubler · chafedINSPECTION TYPE:1C3C LEFT WING T/E CENTER FLAP UPPER SKIN OUTBOARD REPAIR DOUBLER CHAFED. REMOVED, FABRICATED AND REPLACED LEFT WING T/E CENTER FLAP UPPER SKIN OUTBOARD. REPAIR DOUBLER REF A300-600 SRM 57-50-00 PARA 4E AND FIG 205.SDR UPS08153878Floor Panel · damagedINSPECTION TYPE:1C3C MAIN CARGO DECK FLOOR PANEL 241LJ HAS FIELD REPAIRS. REPAIRED MAIN CARGO DECK FLOOR PANEL 241LJ REF A300-600 SRM 53-10-20 TABLE 201 PARA 8A.SDR UPS08153877Floor Panel · damagedINSPECTION TYPE:1C3C MAIN CARGO DECK FLOOR PANEL 241QM HAS FIELD REPAIRS. REPAIRED MAIN CARGO DECK FLOOR PANEL 241QM REF A300-600 SRM 53-10-20 TABLE 201 PARA 8A.SDR UPS08153876Floor Panel · damagedINSPECTION TYPE:1C3C MAIN CARGO DECK FLOOR PANEL 242QM HAS FIELD REPAIRS. REPAIRED MAIN CARGO DECK FLOOR PANEL 242QM REF A300-600 SRM 53-10-20 TABLE 201 PARA 8A.SDR UPS08153875Floor Panel · damagedINSPECTION TYPE:1C3C MAIN CARGO DECK FLOOR PANEL 252QJ HAS FIELD REPAIRS. REPAIRED MAIN CARGO DECK FLOOR PANEL 252QJ REF A300-600 SRM 53-10-20 TABLE 201 PARA 8A.SDR UPS08153874Floor Panel · damagedINSPECTION TYPE:1C3C MAIN CARGO DECK FLOOR PANEL 251SJ HAS FIELD REPAIRS. REPAIRED MAIN CARGO DECK FLOOR PANEL 251SJ REF A300-600 SRM 53-10-20 TABLE 201 PARA 8A.SDR UPS08153865Doubler · chafedINSPECTION TYPE:1C3C LT WING T/E CTR FLAP UPPER SKIN INBOARD. REPAIR DOUBLER CHAFED AS MARKED. REMOVED, FABRICATED AND REPLACED LEFT WING T/E CENTER FLAP UPPER SKIN I/B REPAIR DOUBLER REF A300-600 SRM 57-50-00 PARA 4E AND FIG 205.SDR UPS08153920Cover · crackedINSPECTION TYPE:1C3C SEAL SUPPORT CRACKED AT CORNER ON NR 2 ENGINE BLEED AIR PRECOOLER COVER 423BL. REPAIRED NR 2 ENGINE PRECOOLER SEAL SUPPORT COVER REF EO A300-5430-3114 6-A AND EA 300-5452-01-A1553.SDR UPS08152205Actuator · malfunctionedAFTER T/O RIGHT GEAR DID NOT RETRACT, RT GEAR DOOR STAYED OPEN CONFIRMED BY BDL TOWER. ONCE LANDING GEAR HANDLE WAS LOWERED, GOT 3 DOWN AND LOCKED AND ECAM LANDING GEAR RETRACTION INOP. REMOVED AND REPLACED BRACE STRUT ACTUATING CYLINDER IAW MM 32-31-55-04. SDR UPS08152166Fastener · defectiveCOVER OVER F/O'S ESCAPE ROPE WILL NOT STAY IN PLACE. VELCRO HAS PULLED AWAY FROM COVER. INSTALLED NEW VELCRO TO ESCAPE ROPE COVER. SECURED AND IN PLACE.SDR UPS08151914Light · inoperativeINSPECTION TYPE:N/A GLARESHIELD EMERGENCY LIGHTS INOP. RELAMPED EMERGENCY LIGHT, OPS CHECK GOOD PER MC 050000-01-1-000.SDR UPS06148441Warning Light · inoperativeEVACUATION SLIDE WARNING LIGHT INOP. RELAMPED EVACUATION SLIDE WARNING LIGHT. DEFERRED SAME UNDER MEL 52-73-01-1. TRANSFERED TO DMI LOG UNDER M336982. RESET CONNECTOR 70 WN-A ON THE AUTONOMOUS STANDBY POWER SUPPLY PER AMM 52-73-01. NOTE: AMB 3-52-05-004. TSDR UPS06147284Light · inoperativeFOUND LAV EMERGENCY EXIT LIGHT INOP. RELAMPED.SDR UPS06146620Wheel · overheatedON T/O NR 7 WHEEL OVERHEAT INDICATION AT GEAR RETRACTION. LOWERED LANDING GEAR FOR 5 MINS COOLED TO 285 DEGREES TO RETRACT. REMOVED NR 7 WHEEL ASSEMBLY IN REF WITH MM 12-37-32-0. ALSO, PERFORMED INSPECTION IN REF WITH MM 5-51-16-0. REFERENCE ITEM NR 2 THISSDR UPS06146409Bulb · inoperativeINSPECTION TYPE:N/A FWD ENTRY DOOR OVERHEAD EMERG EXIT 1 OF 7 LIGHT BULBS INOP, WON'T TEST PROPERLY. EPSU SHOWS INT LIGHTS FAULT, 2 LIGHTS REMOVED AND REPLACED AT EXIT SIGN ASSY. FAULT REMAINS. ACCOMPLISHED OPERATIONAL TEST PER MM 33-51-00-5 AND ONLY BULB NSDR UPS06146136Bulb · burned outEMERG EXIT LIGHT HAS 4 BULBS BURNED OUT. RELAMPED, CKS OK.SDR UPS04142055Light · inoperativeLAV EMERGENCY LIGHT INOP. RELAMPED, WORKED OKAY.SDR UPS04142054Light · malfunctionedEMERGENCY EXIT LIGHT STAYS ON. ON GROUND WITH POWER REPEAT. INSTALLED M277614 C/W OPERATIONAL CHECKS PER TPCR PROCEDURES 3-33-MM-04-0360 MM 33-51-00-5 PAR F. CORRECTED PROCEDURES, RESULTS OPS CHECK GOOD.SDR UPS04141992Connector · looseRED LIGHT ON EMERGENCY ESCAPE SLIDE TEST WILL NOT ILLUMINATE, BUZZER OPERATES NORMALLY. DEFERRED EVAC SLIDE WARNING LIGHT PER A300 MEL 52-73-01-1. PLACARD INSTALLED. CLOSING LP 146228 - RESET CONNECTOR ON AUTONOUMOUS POWER SUPPLY UNIT. OPS CK NORMAL, MEL 2
Back to N142UP