N1487A
Service difficulty reports · 243
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1487A' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N1487A' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UIEA2021072401621Engine · oil consumptionREF MDDR 150225 ETOPS RESTRICTED FOR OIL CONSUMPTION(<P>REPLACED #2 ENG SEE LP 1188465 ITEM 12. AC RETURNED TO ETOPS 180 STATUS</P>)SDR UIEA2021072001595A/C Pack · contaminatedALL DURING PREFLIGHT AND TAKE OFF AND CLIMB THRU FL350 AND DESCEND THRU FL 280 AND BELOW A STRONG OILY SMELL WAS PREDOMINANT INSIDE FLT DECK, SMELL DECREASED DURING CRUISE(<P>PERFORMED INSPECTION IAW 05-51-56. CONTAMINATION REMOVED FROM PACK AND PRECOOLER..</PSDR UIEA2021072001600Ecs · contaminatedAT ROTATION DURING TAKEOFF A LIGHT HAZE OR SMOKE WAS OBSERVED AROUND THE FIRST OFFICER POSITION ALONG WITH A SOUR SMELL. THE HAZE DISSIPATED IMMEDIATELY AND THE SMELL SUBSIDED AFTER A FEW MINUTES(<P>PERFORMED INSPECTION IAW 05-51-56 -202-001 CONTAMINATION REMOSDR UIEA2021071901591Warning Message · false activationUPON MX ARRIVAL TO FD, FOUND APU BAT CHG STATUS MSG(<P><SPAN>APU TURNED OFF BY INBOUND CREW. RESTARTED APU + FOLLOWED FAULT TREE 49-11-FT-958. APU OPS NORMAL, MSG CLEARED.</SPAN></P>)SDR UIEA2021062901439Apu · faultedAPU FAULT ON START UP RPM WOULD NOT EXCEED 27%(<P>PERF APU BITE IAW FIM 49-11 FT 986 NO FAULTS NOTED PERF INSP OF APU OIL FOUND APU OIL TO BE OVER SERVICED. DRAINED APU OIL IAW AMM 12-13-04. RAN APU SEVERAL TIMES IAW AMM 49-11-00 NO FURTHER DEFECTS NOTED AT THSDR UIEA2021052001156Ecs · contaminatedOCCASIONAL ELECTRICAL SMOKE SMELL ON DESCENT(<P>PERFORMED INSPECTION OF EQUIPMENT COOLING SYSTEM IAW AMM 21-58-00. NO DEFECTS NOTED. PERFORMED VISUAL INSPECTION OF WATER SPRAY NOZZLES IAW AMM 21-53-05. NO DEFECTS NOTED. AC OK FOR CONTINUED SERVICE. RAN BOTH PASDR UIEA2021051801139Coupler · damagedLOST SATCOM ON FLIGHT. UNABLE TO RESET THROUGH CENTER CDU. WITH NO WORKING HF'S HAD TO PULL CB'S TO RESET SYSTEM, SATCOM WORKING INTERMITTENT ON PLANE.(<P>REMOVED AND REPLACED LEFT AND RIGHT HF COUPLERS. PERFORMED OPS CHECK OF SATCOM IAW AMM 23-25-00. OPS CHECSDR UIEA2021051401131Oxygen Mask · faultedCAPT O2 MASK NOT WORKING PROPERLY, EXTREMELY HARD TO BREATHE THROUGH, NEEDS TO BE REPLACED.(<P>SWAPPED O2 MASK WITH LEFT OBSERVERS. LEFT OBS SEAT UNUSEABLE. PART # INSTALLED CAPT POSITION NOW MC10-08-109 S/N 19290. CURRENT OBS MASK P/N MC10-08-109 S/N 73962.</SDR UIEA2021050301056Indicator · malfunctionedCABIN RATE INDICATOR NEEDLE VIBRATES AND INDICATES CLIMB IN ALL PHASES OF FLIGHT.ONLY STABLE DURING DESCENT.(<P>TRANSFERRED TO MDDR 146207,CAT C DUE 11MAY21. PER DDG 21-33-01A. PLACARD INSTALLED MCC NOTIFIED. P/N S231N210-14 ON ORDER WITH MCC. </P><P>2MAY2021 SDR UIEA2021042901023Lens · detachedR OIL PRESSURE INDICATOR LIGHT FELL OFF(<P>TRANSFERRED TO MDDR 146103 PER MEL 79-33-01-01 CAT C DUE 9 MAY 21 </P><P>2MAY2021 - 1465393 ITEM #4 - REMOVED AND REPLACED RT ENG OIL PRESS LIGHT LENS CAP ASSY PER SWPM 20-84-14 OPS CHECK PER AMM 33-16-00 OIL FOR SVC SDR UIEA2021042500988Connector · damagedFOUND CONNECTOR D10140 ON TS5135 COMP OUTLET TEMP SENSOR 2 BAD BACKSHELL. RH PACK TEMP CONTROL STANDBY MODE SYSTEM INOP TRANSFERRED TO MDDR 145718 IAW DDG 21-51-03-02. CAT C DUE 02MAY21. CONNECTOR D10140 ON TS5135 CAPPED AND STOWED. EH 1346Z. REMOVED AND REPLASDR UIEA2021042000943Purge Can · inoperativeR AFT FUEL PUMP INOP(<P>TRANSFERRED TO MDDR 145638 IAW MEL 28-22-01, CAT C. <BR /></P><P>CVG MX, 21APR, LP 1145778: REMOVED & REPLACED AFT RIGHT FWD PUMP IAW AMM 28-22-03, OPS CHECK GOOD. THIS CLEARS DMI 145638. GTC 2244Z</P>)SDR UIEA2021042100949Circuit Breaker · trippedR AFT FUEL PUMP CIRCUIT BRK(<P>PERF R AFT FUEL PUMP TEST PER AMM 28-22-00. VERIFIED GFI RIGHT NOT POPPED & INSPECTED RIGHT AFT FUEL PUMP FOR ANY LEAKS, FOUND NONE. RESET C/B R AFT FUEL PUMP & OPS CHECK GOOD PER GMM 3.8.1, PER FIM 28022 FT 820, COULD NOT FIND ASDR UIEA2021040700849Seal Depressor · damagedMAIN CARGO DOOR SEAL DEPRESSOR DAMAGE LOWER FWD INSP PER SRM 53-00-15-1A-1 WITHIN LIMITS .(<P>REMOVED DAMAGED SEAL DEPRESSOR LOCATED, DRILLED DEBURRED AND INSTALLED NEW SEAL DEPRESSOR AT MAIN CARGO DOOR CUT OUT FWD LOWER PER B767-300 DRM 51-40-02-0G-0.</P>)SDR UIEA2021040700850Blower · inoperativeCOC PILOT'S EVAS BLOWER INOP(<P>REMOVED AND REPLACED COC PILOT'S EVAS BLOWER AS PER B767 AMM 25-60-99. OPS CHECK OK . </P>)SDR UIEA2021040700851Acoustic Panel · damaged# 1 ENG. HAS DEAMAGED ACOUSTIC PANEL AFT OF 1ST STAGE BLADES (7 O' CLOCK POSITION)(<P>REMOVED AND REPLACED DAMAGED ACOUSTIC PANEL AT #1 ENG. BY 7 O' CLOCK POS. PER B767-300 AMM 72-33-01-004-001-H00, AMM 72-33-01-404-011-H00.</P>)SDR UIEA2021040700852Antenna · damagedCOCKPIT SUPERNUMERARY ELT HAS DAMAGED ANTENNA HOLDER(<P>REMOVED AND REPLACED COCKPIT SUPERNUMERARY ELT AS PER B767-300F AMM 25-63-03</P>)SDR UIEA2021040700853Seal Depressor · damagedMAIN CARGO DOOR AFT SEAL DEPRESSOR UPPER SECTION DAMAGED(<P>REMOVED DAMAGED SEAL DEPRESSOR LOCATED DRILLED DEBURRED AND INSTALLED NEW SEAL DEPRESSOR MAIN CARGO DOOR CUT OUT AFT SIDE UPPER PER B767-300 SRM 51-40-02-0G-0.</P>)SDR UIEA2021040700854Seal Depressor · damagedMAIN CARGO DOOR FWD SEAL DEPRESSOR UPPER SECTION DAMAGED.(<P>REMOVED DAMAGED SEAL DEPRESSOR LOCATED, DRILLED DEBURRED AND INSTALLED NEW SEAL DEPRESSOR AT MAIN CARGO DOOR CUT OUT FWD UPPER SIDE PER B767-300 SRM 51-40-02-0G-0.</P>)SDR UIEA2021040700855Containment Bag · damagedCOCKPIT CONTAINMENT BAG VACUUM SEAL IS BROKEN(<P>REMOVED AND REPLACED COCKPIT AVSAX CONTAINMENT BAG AS PER B767-300F AMM 25-60-00.</P>)SDR UIEA2021040700856Battery · inoperativeAPU BATTERY FAIL REF WORK CARD 6749A012(<P>REMOVED AND REPLACED APU BATTERY PER MM 24-31-04-404-005. OPS CHECK GOOD.</P>)SDR UIEA2021040700857Blocker Door · delaminated#1 ENG I/B T/REV BLOCKER DOOR IS DELAMINATED AT BOTTOM #1 POS.(<P>REMOVED AND REPLACED #1 ENG. I/B T/REV BLOCKER DOOR AT POS. #1 AS PER B767 AMM 78-31-14. OPS CHK NORMAL.</P>)SDR UIEA2021040700858Handle · damagedL-1 ENTRANCE DOOR LOWER HANDLE DAMAGED.(<P>REMOVED AND REPLACED DAMAGED HANDLE AT L-1 ENTRANCE DOOR LOWER SIDE PER B767-300 AMM 20-11-00-910-802.</P>)SDR UIEA2021040700859Display · failedAFTER RUN UP, UPPER DISPLAY FAILED(<P>REMOVED AND REPLACED UPPER EICAS DISPLAY UNIT N10013 & OPS CHECK DISPLAY UNIT TEST OK AMM 31-41-01</P>)SDR UIEA2021032900735Valve · faultedFWD CABIN TEMP ADVISORY MSG ON EICAS(<P>TRSNSFERRED TO MDDR 144401 IAW MEL 21-61-04-02, CAT C, DATED 05APR21. C/B PULLED AND COLLARED TRIM AIR VALVE LOCKED OUT, MCC NOTIFIED.</P><P>27 MAR - LP 1254532 ITEM 3 - ONT - PERFORMED FIM 21-61 FT 803 AND FOUND FWD TRISDR UIEA2021030100430A/C Pack · malfunctionedFWD CABIN TEMP INOP 10 MINS PRIOR TO TOP OF DESCENT(<P>PERFORMED FIM TASK 21-61 FT 803 FOUND NO FAULTS. PERFORMED OPS CHECK IAW AMM 21-61-00. OPS CHECK GOOD.SDR UIEA2021022300409Warning Message · false activationWXR SYS STATUS MESSAGE EN-ROUTE (PERF BITE OF WXR SYS IAW FIM 34-43 FT 805 SYS. OPS CHECK GOOD, NO DEFECTS NOTED AT THIS TIME.)SDR UIEA2021022400414Drive Unit · failedON CLIMB OUT GOT WX FAIL ON LOWER DISPLAYS ACCOMPANIED BY WXR SYS STATUS MSG. THIS IS A RECURRING PROBLEM AND HAS BEEN WRITTEN UP MULTIPLE TIMES.(REMOVED AND REPLACED WX RADAR DRIVE UNIT IAW AMM 34-43-07. OPS CHECK GOOD. T/S PER FIM 34-43 FT 805 TO B18.50. SDR UIEA2021021900360Smoke Detector · failedSMOKE DETECTOR A2 CARGO FAIL(<P>TRANSFERED TO MDDR #142633 IAW MEL 26-16-01-01, CAT C, DUE DATE 01MAR21.</P><P>19FEB21 - 1253816 - ITEM# 8 - CVG - ACFT ARRIVED WITH NO AMBER LIGHTS ILLUMINATED ON CARGO FIRE BOX. ACCOMPLISHED FIM 26-16 FT. 806, NO FAULTS NOTED,SDR UIEA2021020800243Radar · malfunctionedWXR FAIL DISPLAYED INTERMITTENTLY ON MFD WITH EITHER L OR R SYS SELECTED. WXR SYS STATUS MSG DISPLAYED.(<P>PERFORMED WXR BITE PROCEDURE IAW FIM TASK 34-43 FT 805. SYSTEM OK, OPS CHECK GOOD. NO DEFECTS NOTED AT THIS TIME.</P>)SDR UIEA2021020500233Pressure Switch · malfunctionedRIGHT ENG TAI EICAS MESSAGE.(<P>TRANSFERRED TO MEL 30-21-01-04-02, MDDR 141976, CAT "C". DUE DATE 15FEB21. T&I TJ: 21:42Z.</P><P>05JAN, RIV, LP 1246922, ITEM M3: REMOVED AND REPLACED RT ENGINE ANTI-ICE VALVE IAW AMM 30-21-03. OPS CHECK IS GOOD AT THIS TIME. ITSDR UIEA2021020100175Gcu · failedDUE TO PREVIOUS FAULT CT LOOP FAIL, CHANGE APU GCU. R & R APU GCU IAW AMM 24-22-01, OPS CHECK OK.SDR UIEA2021020200192Controller · inoperativeFORWARD CABIN TEMP INOPERATIVE. CABIN COMPT TEMP CONTROL SYSTEM, ALL CARGO CONFIGURATION. TRANSFERRED TO MDDR 141789 PER DDG 21-61-01-02, CAT C, DUE 12 FEB 21. MX ACTION COMPLIED WITH. PLACARDS INSTALLED. 02FEB21 LOG PG 1272386 ITM 3 CVG RESET CB R-15 PERSDR UIEA2021020100173Isolation Valve · leakingBLEED AIR LEAK RT PYLON VISUALLY CHECKED PRESSURE REGULATING VALVE FOR LEAKS. NO LEAKS NOTED. OPERATED CENTER ISOLATION VALVE PER AMM 36-11-00 AND L/R ISOLATION VALVE PER AMM 36-11-00. NO AIR LEAKS SOUNDS NOTED.SDR UIEA2021012500116Controller · inoperativeFWD COMPT TEMP CONTROL SYS INOPERABLE. TRANSFERRED TO DMI 141282, IAW MEL 21-61-01-02, CAT C. REMOVED AND REPLACED CABIN ZONE TEMP CONTROLLER ASSEMBLY, IAW AMM 21-61-03. OPERATIONS CHECK NORMAL. NO EICAS MESSAGES NOTED. THIS CLEARS DMI 141282. MCC NOTIFISDR UIEA2020122102605Oxygen Mask · misinstalledF/O'S ROCKER SWITCH IS STUCK IN INTERCOM EVEN WHEN SWITCH IS IN OFF POSITION. FOUND F/O OXYGEN MASK IMPROPERLY STOWED. STOWED IAW 767 AMM 35-11-51. OPERATIONS CHECK GOOD, PER AMM 23-51-00.SDR UIEA2020121802594Ground Wire · brokenCREW O2 PRESS IND INOPERABLE. TRANSFERRED TO DMI 139696, IAW MEL 35-11-02-01, CAT B. FOUND GROUND BROKEN OFF AT CONNECTOR D752. REPAIRED IAW SWPM 20-30-00. PERFORMED OPERATIONAL CHECK IAW AMM 35-11-00, NO FAULTS NOTED.SDR UIEA2020121702593Controller · malfunctionedFWD CABIN TEMP EICAS MESSAGE DISPLAYED AT GATE. CABIN COMPT TEMP CONTROL SYSTEM ALL CARGO CONFIGURATION. TRANSFERRED TO MDDR 139627, IAW MEL 21-61-01-02, CAT C. 16DEC20-LG PG 1188070 ITEM 5-CVG-REF. MDDR 139627. REMOVED AND REPLACED ZONAL TEMP CONTROLLER,SDR UIEA2020121502577Controller · malfunctionedFWD CABIN TEMP EICAS MESSAGE. FWD CABIN TEMP CONTROLLER INOPERABLE LIGHT ON, IAW MEL 21-61-01-02 CAT C DUE 25DEC20. TRANSFERRED TO MDDR 139550 PLACED ON MEL. PLACARDS INSTALLED. 15DEC20-LG PG 1188066-ITEM 3-PDX-PERFORMED ZONE TEMP CONTROLLER BITE, IAW FIM SDR UIEA2020120402531Warning Message · no indicationDID NOT RECEIVE EICAS MESSAGE TO TURN OFF CENTER FUEL PUMPS WHEN CENTER TANK QUANTITY REDUCED TO 0.0. PERFORMED OPERATIONS CHECK, IAW AMM 28-22-00/501. NO DEFECTS NOTED AT THIS TIME.SDR UIEA2020110902368Starter · inoperativeAPU FAILED TO START (3 ATTEMPTS) APU INOPERABLE, DOOR CLOSED. TRANS TO DMI 137350, PER MEL 49-11-01B CAT "B" DUE 09NOV20 DISP T/R 2154Z SP 07NOV20. T/S APU AND FOUND APU STARTER INOPERABLE. REMOVED AND REPLACED APU STARTER, IAW AMM 49-41-01. OPERATIONS TESSDR UIEA2020100962177Pressure Switch · leakingUPON WALK AROUND DISCOVERED OIL LEAKING FROM APU COWL. FOUND OIL LEAKING FROM LOW OIL PRESSURE SWITCH. REMOVED AND REPLACED LOW OIL PRESSURE SWITCH, IAW AMM 49-94-02. OPERATIONS CHECK GOOD, NO LEAKS NOTED AT THIS TIME.SDR UIEA2020092902127Buss · faultedUTILITY BUS LT & RT WILL NOT RESET. UNABLE TO OPEN CARGO DOORS. PERFORMED COCKPIT RESET, PER AMM 24-00-00. CHECKED FUSES, PER AMM 24-41-02. RESET BPCU, PER AMM 24-41-03 AND CYCLED UTILITY BUS SWITCHES, PER AMM 24-00-00-769-075. OPS CHK GOOD.SDR UIEA2020092952071Valve · malfunctionedRT TEMP PACK EICAS. ISSUED MDDR 134974, IAW DDG 21-51-03-01, CAT C, EXPIRES 05/OCT/20. NO MX ACTION REQUIRED. PLACARDS INSTALLED. PERFORMED BITE OF RT PACK TEMP CONTROLLER, IAW FIM 21-51 FT803. FAULTED RT PACK CONTROL VALVE. REMOVED AND REPLACED RT PACKSDR UIEA2020092302057Controller · malfunctionedFWD CABIN TEMP, PLACED ON DEFERRAL REF DMI 134796 IAW DDG 21-61-01-02, CAT C, DUE 02 OCT. VALVE IN CLOSED POSITION. .25SEP20, LP1289762 ITEM M8: R/R ZONE TEMP CONTROLLER IAW AMM 21-611-03. OPS GOOD. NO FURTHER DEFECTS NOTED AT THIS TIME. THIS CLEARS DMI 134796SDR UIEA2020091872014Fault Light · false activationAPU FAULT ON TAXI IN. APU STARTED W/ NO FAULTS OR DEFECTS NOTED, IAW AMM 49-00-00.SDR UIEA2020091401995Apu · malfunctionedAPU RELIABILITY COLD START ACCOMPLISHED ON FLT 1 EA TPC-SCK SAT -54C FL 380, START. UNSUCCESSFUL ON 3RD ATTEMPT. PERFORMED BITE ON ECU, IAW FIM 49-11 FL 987. NO FAULTS NOTED, APU OPERATION NORMAL.SDR UIEA2020083191892Circuit Breaker · trippedAFTER LANDING, APU DID NOT STSRT (3 TRIES) (<P>UPON INVESTIGATION NOTED CIRCUIT BREAKER #CB1 ON RH GEN CONTROL UNIT. RESET BREAKER & CIRCUIT BREAKER DID NOT POP AGAIN. PERFORMED APU ECU BITE & OPS CHECK AS REQUIRED PER FIM 49-11 FAULT TREE 805. NO FAULTS NOTEDSDR UIEA2020083101897Apu · unknownAPU FAULT LIGHT ON 2 START ATTEMPTS(<P>OPS CHECKED APU START. STARTED 05 CONSECUTIVE TIME WITH NO ISSUES. IAW AMM 49-11-00 OPS GOOD </P>)SDR UIEA2020090251870Modulating Valve · malfunctionedAFT CABIN ZONE TEMPERATURE VALVE INOPERABLE. PERFORMED ZONE TEMPERATURE CONTROLLER BITE IAW AMM 21-61-03. FOUND AFT ZONE TRIM VALVE FAULT. TRANSFERRED TO MDDR 133363 PER MEL 21-61-04-02, CAT C, DUE 03 SEP 20 18:47Z DC, PLACARDS INSTALLED. CB'S COLLARED. L
Back to N1487A