What was found
FOUND CONNECTOR D10140 ON TS5135 COMP OUTLET TEMP SENSOR 2 BAD BACKSHELL. RH PACK TEMP CONTROL STANDBY MODE SYSTEM INOP TRANSFERRED TO MDDR 145718 IAW DDG 21-51-03-02. CAT C DUE 02MAY21. CONNECTOR D10140 ON TS5135 CAPPED AND STOWED. EH 1346Z. REMOVED AND REPLACED CONNECTOR D10140 ON RIGHT PACK IAW B767 SWPM 20-60-03 TABLE 6. OPS CHECK RIGHT PACK ON STANDBY MODE, OPS CHECKS OK AT THIS TIME. THIS CLEARS MDDR 145718.