N16713
Service difficulty reports · 95
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N16713' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N16713' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2026080918388Bumper · damagedSECURED WIRES AND COVER FOR EMERGENCY EXIT AISLE LIGHTS AT SEATS 31ABC & 34ABC, IAW AMM 33-51-11. TROUBLESHOOT AND FOUND BUMPER-ENDBAY BUMPER TO HOLD AISLE PATCH LIGHTING HOUSING DAMAGED. INSTALLED NEW SERVICEABLE BUMPER-ENDBAY AND ATTACHED (AISLE) FLOOR PROXSDR CALA2026062417318Bulb · inoperativeLIGHT INOPERATIVE AT 21A EMERGENCY LIGHT SIGN. REPLACED THE BULB AT EMERGENCY EXIT SIGN ABOVE DOOR AT SEAT 21A IAW AMM 33-51-01-960-801.SDR CALA2026060116688Lamp · inoperativeFLIGHT READINESS CHECKLIST (ADDED BY EC0500-01365) PROCEDURE - EMERGENCY PROXIMITY LIGHTS INOP AT SEATS ROWS 12, 15 AND 21. TROUBLESHOT EMERGENCY LIGHTS SYSTEM PER FIM 33-50 TASK 801. REF WDM 33-51-21-909, ROWS 12, 15 AND 21 ARE POWERED BY BATTERY PACK M1669. SDR CALA2025111411214Skin · debondedRIGHT WING, OTBD FLAP, AFT FLAP, INBD END, UPPER SKIN DEBONDED AREAS NOTED, AREA NR 1 L=1.25 INCH W=1 INCH, AREA NR 2 L=1 INCH W=1 INCH.. CLEANED, PREPPED, PERFORMED THE PERMANENT REPAIR AND RESTORED FINISHED ON RT WING OTBD AFT FLAP UPPER SKIN IAW SRM 57-53SDR CALA2025101410076Seal · damagedON TAKEOFF LOUD AIRFLOW NOISE FROM FRONT WINDOWS NOISE STOPPED A BV 5000FT BLD DCT PRSRS ERRATIC DEBRIFIED THE CREW. CREW STATED VERY LOUD WIND NOISE ON TAKEOFF. NO PRESSURIZATION ISSUES. NOISE DISSAPPEREAD AFTER REACHING 5000FT. BLD DUCT NEEDLES WERE ERRATIC SDR CALA2025101009891Slide · no discrepancy2L DOOR SLIDE COMPONENTS EXPOSED INSPECTED 2L SLIDE, NO COMPONENTS EXPOSED, OK FOR SERVICE, PER ESCAPE SLIDE PACK CHECK.REFERENCE: TASK 25-66-01-200-802SDR CALA2025100309573Light · inoperativeSEAT 32C EMERGENCY FLOOR PROX LIGHT INOPERATIVE. REMOVED AND REPLACED SEAT 32C EMERGENCY FLOOR PROX LIGHT. OPS CHK NORMAL. REF AMM 33-51-11.SDR CALA2025090508504Fastener · looseDOOR 2L FWD GIRT BAR BRACKET IS LOOSE. SECURED LOOSE FASTNERS IAW AMM 25-66-02-400-801SDR CALA2025082908274Housing · damagedEMERGENCY EXIT SIGN ATTACHED TO LIFE RAFT COMPARTMENT IN BUSINESS CLASS DAMAGED. PART 1 OF EC/RA 3351-01511 HAS BEEN COMPLIED WITH. ACCOMPLISH INSPECTIONS PER PART 2 PERIOR TO EACH FLIGHT CYCLE & ACCOMPLISH PART 3 WITHIN 4 FLT CYCLES. INTERIM REPAIR OF BUSINSDR CALA2025080407253Lamp · inoperativeEMERGENCY LIGHTING SYSTEM OPS CHECK, EMERGENCY LIGHT ON BIN ABOVE ROW 34 ABC INOPERATIVE. REPLACED THE LAMPS IAW AMM 33-51-00/501. OPS CHECK NORMAL.SDR CALA2025060405257Spring · brokenEMERGENCY LIGHT SWITCH GUARD SPRING BROKEN AT AFT ATTENDANTS PANEL. REPLACED EMERGENCY LIGHT SWITCH GUARD.PARTS USED: 19-3351-3-0014, QTY :1SDR CALA2025041403744Battery · expiredEMERGENCY FLASHLIGHTS INSPECT {B737-25-3-1061} - FLASHLIGHTS ABOVE AFT LH FLT SEAT HAVE BATTERIES THAT EXPIRE WITHIN 150 DAYS.(AUG. 2025) R/R FLASHLIGHT BATTERIES. PARTS USED: 76-2560-3-0001,QTY :1SDR CALA2025020202163Anti-Skid Valve · faultedAFTER AIRCRAFT WENT WHEELS UP ANTI SKID LIGHT ILLUMINATED FLAGGED AS SDR ACP'D AACU BITE, FIM 32-42 TASK 801. TWO FAULTS FOR VLV 3-4. SEE PICS. FOUND CORROSION ON OUTTER SHELL OF CONNECTOR ON VALVE V124. CLEANED AND ACP FIM 32-42 TASK 805. MESSURED RESISTANCESDR CALA2024021300415Transmitter · intermittentFLT CONTROL MASTER CAUTION LIGHT CHECKED E&E BAY FOR OPEN C/BS. FOUND NO OPEN BREAKERS. CYCLED FIGHT CONTROLS AND DID NOT NOTICE A SIGNIFIGANT PRESSURE DROP IN A OR B SYSTEMS. DUE TO EXTENSIVE INTERMITTEN FAULTS IN THE FSEU. FSEU WAS REPLACED AS PRECATUIONARY.SDR CALA2023122003686Frame · chafedMAIN CABIN FRAME HAS A CHAFING CONDITION STA 727 STR 1 ACCOMPLISHED REPAIR ON MAIN CABIN FRAME STA 727 STR 1 ACCORDING TO EC/RA #:5340-02176.SDR CALA2023111703413Floorbeam · corroded(B737-06-3-0049) CORROSION ON MN DK FRAME STA 947 LBL 44-54 REMOVED AND REPLACED WITH NEW T-CHORD AND REPAIR PARTS ON FLOOR BEAM STRUCTURE AT MAIN CABIN STA 947.5 LBL60-RBL60 IAW B737 SRM 53-70-51-2R-5 REPAIR 5. SEE FORM 44-0008 ATTACHED.SDR CALA2023111503396Floor Support · corroded(B737-06-3-0049) CORROSION ON MAIN CABIN FLOOR STRUCTURE AT STA 958 LBL 50 REMOVED AND INSTALLED NEW INTERCOSTAL P/N:147A5660Y21 ON MAIN CA BIN FLOOR SUPPORT STA 947 LBL 50 IAW B737 SRM 51-40-02-0G-0 PARA 7.A (1)SDR CALA2023111503394Floor Support · corroded(B737-06-3-0049) MAIN CABIN STA 947 RBL 51 FLOOR SUPPORT STRUCTURE HAS CORROSION REMOVED AND INSTALLED NEW INTERCOSTAL P/N:147A5660U22, ON MAIN C ABIN FLOOR SUPPORT STA 947 RBL 51 IAW B737 SRM 51-40-02-0G-0, PA RA 7.A. (1).SDR CALA2023111503392Floor Support · corroded(B737-06-3-0049) MAIN CABIN STA 947 RBL 45 FLOOR SUPPORT HAS CORROSION REMOVED AND INSTALLED NEW SUPPORT STRUCTURE P/N 147A5676U6 ON MA IN CABIN STA 947 RBL45 FLOOR SUPPORT IAW B737 SRM 51-40-02-0G-0 PARA 7.A(1).SDR CALA2023111503375Unknown · corroded(B737-06-3-0049) MAIN CABIN STA 947-STA 986 R/H HAS CORROSIONSDR CALA2023111503373Crease Beam · corroded(B737-06-3-0049) SEVERAL AREAS OF CORROSION ON L2 CREASE BEAM ST A 947-987 REMOVED AND INSTALLED NEW CREASE BEAM ON L2 STA 947-987 IAW B737 -700 SRM 51-40-02-0G-0 PAR 4.B FIG 4 AND SRM 51-40-02-0G-0 FAR 7 ,D,FIG 17.SDR CALA2023111503368Crease Beam · corroded(B737-06-3-0288) CREASE BEAM CORRODED BY R1 DOOR STA 287 TO 344 REMOVED AND REPLACED CREASE BEM R1 DOOR STA 287 TO 344 IAW SRM 5 1-40-02-0G-0 PAR 4 AND PAR 7.SDR CALA2023111003324Floor Support · corroded(B737-06-3-0288) CORROSION ON MAIN DECK FLOOR STRUCTURE AT RBL 1 3, FROM STA 287-292 REPLACED MAIN DECK FLOOR STRUCTURE AT RBL 13 FROM STA 287-292 IA W SRM 51-40-02-0G-0 PARA 4.7 AND 9 AND DWG 141A5750 REV A. FORM 44-0008 ATTACHED.SDR CALA2023110603298Floor Support · cracked(B737-06-3-0288) CRACKED INTERCOSTAL IN MAIN DECK FLOOR STRUCTURE BETWEEN STA 312-328, RBL 32 INTERCOASTAL PN 141A5410U12 REPLACED ON MAIN DECK FLOOR STRUCTUR E BETWEEN STA 312-328, RBL 32" PER BOEING SRM 51-40-02-0G-0 PAR 7.C. DATA WAS TRANSCRIBED FROM PAPER SDR CALA2023110603291Floorbeam · corroded(B737-06-3-0049) MAIN CABIN STA 986 LBL 30-LBL 35 HAS SEVERAL AREAS OF CORROSIONSDR CALA2023071002207Unknown · warning lightNOSE LANDING GEAR NOSE GEAR GREEN LIGHT DOES NOT GO OFF WITH LAN DING GEAR LEVER AT UP, NOSE GEAR RED LIGHT ON NOSE GR BOTH LIGHTS ON WHEN HANDLE IN OFF POSITION WITH ASSOCTD ELEVATED WIND NOISE UP AND RED LIGHT EXTINGUISHED (GREEN STAYED ON) AND NOISE WENT AWSDR CALA2023062802060Control Module · warning lightFLT CONTROL B LOW PRESSURE LIGHT LIGHT ON LOW SPEED REJECT AT 85 KTS. UPDATED MAA CODE FIX USING VENDOR MAA SCREEN PLEASE CONTACT TOMC BEFORE COMMENCING ANY WORK. AND REPLACED FLIGHT CONTROL MODULE P5-3 REF. AMM TASK 27-09-45-000-801 AND AMM TASK 27-09-45-400-SDR CALA2022111603154Module · leakingENGINE 1 LOW HYDRAULIC PRESSURE LIGHT DURING DESCENT. QUANTITY GAUGE READ 18 PERCENT. FOUNDS SYS A PRESSURE MODULE LEAKING. ADD EMP:349838 CHECKED #1 ENG EDP CASE DRAIN FILTER. NO DEFECTS NOTED. R/R CASE DRAIN FILTER IAW AMM 29-11-51. LEAK CHECK GOOD DURING SDR CALA2022052301320Fire Detector · activated*EMERGENCY DECLARED*FIRE ALARM ACTIVATED IN LAV AFT AIRCAFT RIGHT TALKED TO CREW AND PASSENGER. PASSENGER CLAIMED SHE SPRAYED AIR FRESHENER AFTER PERFORMING NUMBER TWO. TESTED SMOKE DETECTOR WITH NO FAULTS. REF AMM 26-14-00.SDR CALA2022011700157Skin · damagedAIRCRAFT SKIN HAS GROUND DAMAGE STA.400 TO STA.420, S-20L TO S-22L. VISUALLY INSPECTED AREA OF REMOVED FUSELAGE SKIN STA 400-420 BETWEEN S20L AND S22L. NO FURTHER DAMAGE NOTED. OK TO CONTINUE. CUT AND REMOVED DAMAGE TO SKIN FROM STA.400 TO STA.420 BETWEEN S-SDR CALA2022011700156Stringer · damagedSTRINGER S-21L IS BROKEN BETWEEN STA.400 AND STA.420 DUE TO GROUND DAMAGE. VISUALLY INSPECTED AREA OF REMOVED DAMAGED STRINGER 21L BETWEEN STA 380-440 LH. NO FURTHER DAMAGE NOTED. OK TO CONTINUE CUT AND REMOVED DAMAGED STRINGER SECTION BETWEEN STA.380 AND STASDR CALA2022011400141Shear Tie · damagedSHEAR TIE DAMAGED AT STA.420 BETWEEN S-20L AND S-21L. VERIFIED SHEAR TIE PER AVO 713-22-01-06-01 REV. C. STEP B.3.. OK TO CONTINUE. MGH QC775 VERIFIED SHEAR TIE PER AVO 713-22-01-06-01 REV. C. STEP B.3. VERIFIED REFORM OF SHEAR TIE. PERFORMED HFEC OF REWORKEDSDR CALA2022011000089Stringer · damagedSTRINGER S-21L IS BROKEN BETWEEN STA.400 AND STA.420 DUE TO GROUND DAMAGE. VISUALLY INSPECTED AREA OF REMOVED DAMAGED STRINGER 21L BETWEEN STA 380-440 LH. NO FURTHER DAMAGE NOTED. OK TO CONTINUE CUT AND REMOVED DAMAGED STRINGER SECTION BETWEEN STA.380 AND STASDR CALA2022011000088Skin · damagedAIRCRAFT SKIN HAS GROUND DAMAGE STA.400 TO STA.420, S-20L TO S-22L. VISUALLY INSPECTED AREA OF REMOVED FUSELAGE SKIN STA 400-420 BETWEEN S20L AND S22L. NO FURTHER DAMAGE NOTED. OK TO CONTINUE. CUT AND REMOVED DAMAGE TO SKIN FROM STA.400 TO STA.420 BETWEEN S-SDR CALA2020072001059Battery Pack · no testRIGHT OVERWING INSIDE AND OUTSIDE EMERGENCY LIGHTS INOPERATIVE. CHARGED THE BATTERY PACKS IAW MM 33-51-06, ALL RT EMERGENCY LIGHT CHECKED GOOD. LT ROW 23-29ABC SEAT MOUNTED EMERGENCY LIGHT ROW 12 & 21ABC OVERHEAD BIN BULLNOSE EMERGENCY LIGHT FAILED CAPACITY CSDR CALA2020010600075Charger · inoperativeEMERGENCY AISLE PATH LIGHTING FROM ROW 22-15 ARE INOP. INCLUDING RED LITE FOR EMERGENCY EXIT. R/R M1669 CHARGER, OPS CHKD GOOD. REF AMM 33-51-06.SDR CALA2019100501701Pin · looseLANDING GEAR POSITION LIGHTS LIGHTS NOT CORRECT 32601000 NOSE LDG GEAR RED LIGHT ON IN FLT GEAR HDL OFF PERFORMED PSEU BITE FOUND FAULT 32-61013. TROUBLESHOOTING FOUND NOSE GEAR SENSOR S845 WIRE W7036-A-B LOOSE PIN AT TB42. RESECURED PIN IN TB PER WD 32-64-11SDR CALA2018101502113Spoiler Sys · malfunctionedSPOILERS AIRPLANE ROLLS RIGHT WHEN THE SPOILERS ARE DEPLOYED EMERGENCY DECLARED. FOURTH WRITEUP. ACFT CURRENTLY OOS.SDR CALA2018012900388Unknown · odorSTRONG DIRTY SOCK SMELL DURING CLIMB AND DESCENT, SMELL MAINLY IN AFT CABIN AREA. COULD NOT SMELL ANY ODOR, NEED FURTHER CREW EVALUATION.SDR CALA2017090803062Relay · faultyAFTER DEPARTURE, HAD A RUNAWAY NOSE UP STAB TRIM. ALSO HAD A SPEED TRIM FAIL LIGHT ON. EMERGENCY DECLARED. REPLACED THE STAB TRIM RELAY R64 AT J4 BOX. COMPLIED WITH EC/RA 2741-01216. PERFORMED BITE CHECK FOR DFCS, OPS CHECKED GOOD. PERFORMED LAND VERIFY TSDR CALA2017073102454Battery Pack · inoperativeAFT FA JUMPSEAT FLASHLIGHT NOT BLINKING, NOT CHARGING. REMOVED AND REPLACED THE FLASHLIGHT BATTERY IAW AMM 25-64-00. OPS CHECKED GOOD.SDR CALA2017070902121Starter · malfunctionedINITIALLY NR 1 ENGINE OVERHEAT LIGHT CAME ON EARLY DURING DELAYED NR 1 ENGINE START. THEN 3 FIRE WARNINGS. DISCHARGED BOTH FIRE BOTTLES. DEBREIF OF FLT CREW SAID NO. 1 ENG. STARTER HAD REMAINED ENGAGED AND CAUSED AN OVERHEAT CONDITION ON #1 ENG. REMOVED ANDSDR CALA2017070702110Starter · malfunctionedSTARTER STAYED ENGAGED AFTER NR 1 ENG START. OVERHEAT DETECTION CAUTION AND BOTH FIRE BOTTLES WERE FIRED. NR 1 ENG STARTS AND RUNS NORMAL NO PROBLEMS NOTED. ROTABLE PARTS CHANGE WAS INDICATED.SDR CALA2017060501687Oven · sparksOVEN SMOKING OR SPARKING 205 OVEN 2 SMOKES ON HIGH BURNING WALL LINER REMOVED AND REPLACED GALLEY OVEN 205.SDR CALA2017052201546Cover · brokenMID CABIN EMERGENCY EXIT SIGN COVER BROKEN AND FELL OFF. RESECURED EXIT SIGN COVER ACFT OK TO CONTINUE.SDR CALA2017042101096Sign · missingDOOR 1R, SMALL EMERGENCY EXIT SIGN IS MISSING. REPLACED EMERGENCY EXIT LIGHT IAW AMM 33-51-01. OPS CHECK GOOD.SDR CALA2017041400972Trim Motor · faultyELEC STAB TRIM FAILED AFTER TAKE OFF. EMERGENCY DECLARED. T/S, FOUND STAB TRIM MOTOR BAD. REMOVE AND REPLACE REF AMM 27-41-71-000/400-801. OPS CKS/TESTS NORMAL. PERFORMED LAND VERIFY REF AMM 22-11-00 ALL TESTS PASSED.SDR CALA2017020600280Battery Pack · dischargedLT EMERGENCY LIGHT INOP R22 AFT. R&R BATTERY PACK AT M1670 PER AMM 33-51-960-804, LIGHTS NOW OP GOOD, ALL EMERGENCY LIGHT CK GOODSDR CALA2017020600274Controller · faultyAUTO TEMPERATURE CONTROL DOES NOT OPERATE CONTROL CAB NOTICED ACRID ODOR FOUND 2 CIRCUIT BREAKER OPEN LEFT TEMP CONT/AUTO/MAN P6 4 A 2/3 REMOVED AND REPLACED CABIN ZONE TEMP CONTROLLER REF AMM TASKS 21-61-01-000-801, 21-61-01-400-801 AND IPC 21-61-35-01 ITEM SDR CALA2016111100883Unknown · malfunctionedON CLIMB OUT WHEN GEAR HANDLE MOVED FROM UP TO OFF AFTER T/O CHECKLIST, THE RED LANDING GEAR LIGHTS (ALL 3) CAME ON AND IT SOUNDED AS IF THE GEAR WAS BEING LOWERED WITH DOORS FIRST. BACK TO UP THEN OFF, WORKED SECOND TIME BITE TEST PSEU PER FIM 32-09-801, NO E
Back to N16713