N17169
Service difficulty reports · 76
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N17169' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N17169' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR JJBA20261023008Elec Connector · looseRH AFT EXIT LOCATING SIGN AT EXIT ROW INOPERATIVE. UPONG REMOVAL FOUND LOOSE CONNECTION. REINSTALLED EXIT LOCATING SIGN. OPS CHECK SAT.SDR JJBA20260406003Wire Harness · damagedMCD EXT EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED MCD EXT EMERGENCY LIGHT LAMP. OPS CHECK FAILED. FOUND DAMAGE TO SP7426 ON THE HARNESS. REMOVED AND REPLACED HARNESS. OPS CHECK SAT.SDR JJBA20260303001Apu · contaminatedTHICK ACCURATE (ELECTRICAL/MECHANICAL SMELL) SMOKE COMING FROM THE VENTS IN THE CABIN AND FLIGHT DECK DURING CLIMBOUT. DEICED WITH TYPE 1 AND 4 PRIOR TO DEPARTURE. CAPTAIN SAID IT WASN’T DEICE FLUID SMELL. OCCURRED ON GEAR UP AROUND 700 FEET NOTICED SMOKE COMISDR JJBA20260119038Lamp · inoperativeCOCKPIT AND ROW 3 CEILING EMERGENCY LIGHTS INOPERATIVE. REMOVED AND REPLACED COCKPIT EMERGENCY LAMP AND ROW 3 AISLE EMERGENCY LAMP. OPS CHECK SAT.SDR JJBA20251209021Flashlight Assy · inoperativeFWD FA EMERGENCY FLASHLIGHT INOPERATIVE. REMOVED AND REPLACED FWD FA EMERGENCY FLASHLIGHT. OPS CHECK SAT.SDR JJBA20251111049Floor Support · corrodedLH FLOOR SUPPORT AT FR17, STR 1L HAS CORROSION. REPAIRED LH FLOOR AT FRAME 17SDR JJBA20251024069Floor Support · corrodedRH FLOOR GUSSET AT FR 20, STR 4R HAS CORROSION. REMOVED DAMAGED GUSSET AND INSTALLED NEW GUSSET AT RH FLOOR FR 20 STR 4RSDR JJBA20251024067Skin · crackedLH ELEVATOR LOWER SKIN BEHIND ACCESS PANEL 335HB IS CRACKED. PERFORMED TRIM OUT OF CRACK ON LH ELEVATOR LOWER SKIN MOLDING GLANGE FOR ACCESS PANEL 335HB. NO FURTHER DEFECTS NOTED.SDR JJBA20251014045Skin · damagedDAMAGE TO AIRCRAFT SKIN AT FORWARD LEADING EDGE 2ND FROM IB HINGE POINT ON LH ELEVATOR. REPAIRED SKIN DAMAGE AT FWD LEADING EDGE 2ND CUTOUT FROM INBD HINGE POING ON LH ELEVATOR BY CUTTING OUT DAMAGED SKIN AND INSTALLING A REINFORCING DOUBLER.SDR JJBA20251014044Skin · corrodedCORROSION ON HEATED WATER DRAIN BETWEEN FRAMES 60 TO 61 LOWER EXTERNAL FUSELAGE. REMOVED CORROSION BY PERFORMING CUTOUT AND INSTALLING A DOUBLER AT HEATER WATER DRAIN BETWEEN FRAMES 60 AND 61 ON LOWER EXTERNAL FUSELAGE.SDR JJBA20251024070Bracket · corrodedLEFT WING OTBD FLAP OTBD FAIRING INTERIOR BRACKET HAS CORROSION. LH WING OB FLAP OB FAIRING REPLACED 1EA BRACKET.SDR JJBA20251111046Strap · corrodedLEFT WING LOWER SPAR STRAP CORRODED FROM RIB 19 TO RIB 25. REMOVED CORROSION ON LH WING LOWER SPAR STRAP FROM RIB 19 TO RIB 25 BY BLENDINGSDR JJBA20251111045Strap · corrodedLH WING UPPER SPAR STRAP CORRODED FROM RIB 19 TO RIB 25. REMOVED CORROSION ON LH WING UPPER SPAR STRAP FROM RIB 19 TO RIB 25 BY BLENDINGSDR JJBA20251024068Support · crackedLH ELEVATOR RVDT SUPPORT CRACKED AND CORRODED. REMOVED AND REPLACED LH ELEVATOR RVDT SUPPORT.SDR JJBA20251024064Floor Support · corrodedCORROSION ON RH FLOOR BEAM BETWEEN FRAMES 17 AND 18. INSTALLED NEW RH FLOOR BEAM BETWEEN FR 17-20 AND FLOOR SUPPORT AT FR 20.SDR JJBA20251014046Skin · corrodedCORROSION ZONE 171 AFT LOWER FUSELAGE BY AIRCRAFT PLACARD. REMOVED CORROSION AND REPAIRED AREA ZONE 171 AFT LOWER FUSELAGE BY AIRCRAFT PLACARD BY PERFORMING CUTOUT AND INSTALLING A DOUBLER AND FILLER.SDR JJBA20251111048Floorbeam · corrodedCORROSION ON FLOOR BEAM AT NUTPLATE, FLOOR BEAM FRAME 21. FLOOR BEAM/SILL HAS BEEN REMOVED AND REPLACED.SDR JJBA20251111047Floorbeam · corrodedCORROSION ON THE RH FLOOR BEAM FRAME 20 FWD SIDE OF THE SERVICE DOOR. REMOVED AND REPLACED RH FLOOR BEAM FR20.SDR JJBA20251024071Floorbeam · corrodedCORROSION ON THE FLOOR BEAMS AT FRAME 22 SOFT SIDE OF THE SERVICE DOOR. INSTALLED NEW FLOOR BEAM BETWEEN FR 22-24 AFT SDIE OF THE SERVICE DOOR.SDR JJBA20251024062Floor Support · corrodedCORROSION FOUND ON CENTER OMEGA BIN GUSSET, BETWEEN FRAMES 59 & 61. INSTALLED NEW GUSSET BETWEEN FRAMES 59 & 61.SDR JJBA20251024066Floor Support · corrodedCORROSION FOUND ON RT OMEGA BIN GUSSET, BETWEEN FRAMES 59 & 61. INSTALLED NEW RT GUSSET PLATESDR JJBA20251024065Floor Support · corrodedCORROSION FOUND ON LT OMEGA BEAM GUSSET, BETWEEN FRAMES 59 & 61. REMOVED BAD GUSSET BETWEEN FRAMES 59 & 61 LT SIDE AND INSTALLED NEW GUSSETSDR JJBA20241223048Lamp · inoperativeCOCKPIT EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED COCKPIT EMERGENCY LIGHT. OPS CHECK SAT.SDR JJBA20241202010Lamp · inoperativeRH FWD EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED RH FWD EMERGENCY LIGHT BULB. OPS CHECK SAT.SDR JJBA20240126044Terminal · intermittentMCD EMERGENCY LIGHT INTERMITTENT (BAD GROUND). REPLACED GROUND WIRE RING TERMINAL. PERFORMED OPS CHECK OF MCD EMERGENCY LIGHT. OPS CHECK GOOD.SDR JJBA20231226026Sign · inoperativeRH CABIN ESCAPE HATCH LARGE EMERGENCY EXIT SIGN INOPERATIVE. REMOVED AND REPLACED LIGHT ASSEMBLY. OPS CHECK GOOD.SDR JJBA20231106001Controller · inoperativeLOST PRESSURIZATION ON CLIMB OUT IN AUTO. PERFORMED MANUAL PRESSURIZATION. OPS CHECK SAT. PERFORMED AUTO PRESSURIZATION. OPS CHECK FAILED. REMOVED AND REPLACED DIGITAL CONTROLLER. OPS CHECK SAT FOR NEW CONTROLLER. AIRCRAFT FAILED LEAK DOWN CHECK. REMOVED AND SDR JJBA20230919018Unknown · unknownEMERGENCY EXIT SIGN ABOVE GALLEY FALLING OFF. RESECURED EMERGENCY EXIT SIGN.SDR JJBA20230821008Battery Pack · inoperativeMULTIPLE EMERGENCY EXIT SIGNS DO NOT ILLUMINATE. REMOVED AND REPLACED #4 EMERGENCY BATTERY. OPS CHECK SAT.SDR JJBA20230804002Charger · inoperativeLH EXTERNAL FWD EMERGENCY LIGHT INOPERATIVE. SWAPPED BPS 1 CRADLE WITH BPS 3 CRADLE AND PROBLEM WAS FIXED. RETURNED TO ORIGINAL CONFIGURATION. SUSPECT BAD BPS 1 CRADLE, P.O.O. REMOVED EMERGENCY LIGHT 1 BATTERY AND CRADLE. INSTALLED NEW EMERGENCY BATTERY PACK. SDR JJBA20230803001Lamp · inoperativeMCD EMERGENCY EXTERNAL LIGHT INOPERATIVE. REMOVED AND REPLACED MCD EMERGENCY LIGHT ASSEMBLY. OPS CHECK GOOD.SDR JJBA20230724021Control Unit · inoperativeAT 16000 FT PITCH TRIM MAIN AND BACKUP INOPERATIVE. ALSO RUDDER 1 AND 2 INOPERATIVE. REMOVED AND REPLACED HSCU. REMOVED AND REPLACED #2 RUDDER PRESSURE SWITCH. OPS CHECK SAT FOR BOTH. PERFORMED PITOT STATIC TEST. OPS CHECK SAT.SDR JJBA20230724023Unknown · inoperativeEICAS MESSAGE IC BUS FAIL ILLUMINATED AT FL 260. REMOVED AND REPLACED #1 IC-600. OPS CHECK GOOD.SDR JJBA20221229027Container · puncturedFO LIFE VEST BAG PUNCTURED. REMOVED AND REPLACED FO LIFE VESTSDR JJBA20220728029Galley · inoperativeBURNING SMELL FROM GALLEY IN FLIGHT. NO SMELL AFTER COFFEE MAKERS OFF ON THE GROUND. PERFORMED OPERATIONAL CHECK ON COFFEE MAKERS, COULD NOT FIND BURNING SMELL IN THE GALLEY. R&R BOTH COFFEE MAKERS. OPS CHECK GOOD, BURNING SMELL NOT PRESENT
RH - PN 500-0640SDR JJBA20220621020Lamp · inoperativeFOUND COCKPIT CEILING EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED COCKPIT CEILING EMERGENCY LIGHT LAMP. OPS CHECK GOOD.SDR JJBA20220602002None · noneAT REAR USE II EXT, SUSPECTED CRACKS (17X) FOUND ON RH SIDE SKIN BTW FR 77-FR80 AND BTW STR 3R-9R. AFTER NDT INSPECTION 13 CRACKS CONFIRMED ON RH SIDE SKIN BTW FR77-80 STR 3R-9R. AT RFII (9X) CUTOUTS C/OUT ON RH SKIN BTW FR 77-80 STR 3R-9R. ITEM 5 (X9) BUSHINGSDR JJBA20220527053None · noneAT REAR FUSE, CRACK FOUND ON RH TOP SKIN BTW FR 76 - FR 77 AT STR 2R. BUSHING REPAIR ON RH REAR FUSE 1 UPPER SKIN, BTW SKIN EDGE FR76 AND BTW STR 2R- 3RSDR JJBA20220527052None · noneCF 4 UNDERFLOOR FR 59 BTW STR 19L - 19R CORROSION ON TOP FLANGE. SPLICE REPAIR ON CENTER FUSE 4 FR 59, BTW STR 20L-21L & BTW STR 20R - 21RSDR JJBA20220527048None · noneAT REAR FUSE, CRACK FOUND ON LH TOP SKIN AT FR 75 BTW STR 2L-3L. REPAIR DOUBLER ON LH FUSE 1 UPPER SKIN AT FR 75 & BTW STR 1L-3SDR JJBA20220526051None · noneAT REAR FUSE, CRACK FOUND ON RH TOP SKIN AT FR 75 BTW STR 2R - 3 R. REPAIR DOUBLER ON RH FUSE 1 UPPER SKIN, AT FR 75 & BTW STR 2R - 3 RSDR JJBA20220526050None · noneAT REAR FUSE II EXT, SUSPECTED CRACKS (12X) FOUND ON LH SIDE SKIN BTW FR 77 - FR80 AND BTW STR 3R - 9 R. 8 BUSHING REPAIRS ON LH REAR FUSE 2 SKIN ON FR 77-78-79 AND BTW STR 3L-10L. REPAIR DOUBLERS ON LH FUSE SKIN. DOUBLER #1 ON FR 78 & BTW STR 5L-7L & DOUBLER SDR JJBA20220526049None · noneSUSPECTED CRACK ON LH BEAM AT FR33. REPAIR DOUBLER ON LH CENTER FUSE 2 OMEGA BEAM AT FRAME 33SDR JJBA20220524045None · noneRF1 RH SHEAR CLIP CRACKED BTW STR 10R-9R FR68. SHEAR CLIP REPLACEDSDR JJBA20220524043None · noneCF1 RH O-BEAM AT FR 23 CORROSION ON TOP. OMEGA BEAM REPAIRED AT FR23SDR JJBA20220304002Acm · inoperativeSMOKE OF AN UNDETERMINED ORIGIN IN COCKPIT IN FLIGHT. REMOVED AND REPLACED #1 AIR CYCLE MACHINE. PACK OVER TEMPERATURE SWITCH AND PACK SETBACK SWITCH WIRES TO CONNECTORS SNAPPED OFF DURING PACK SYSTEM CHECK. RE-PINNED BOTH CONNECTOR WIRES. NO FAULTS OR WARNINGSDR JJBA20201202001Connector · unsecureFLAP FAIL ON EICAS. CREW REPORTED THAT THEY SELECTED FLAPS TO 9 DEGREES AT 220 KNOTS AND THEY RECEIVED FLAP FAIL MESSAGE. FLAPS DID NOTE MOVE FROM THE 0 DEGREE POSITION. THEY DID NOT RECEIVE A FLAP LOW SPEED MESSAGE. CMC HAS LT MOTOR BRAKE FAIL ALONG WITH SDR JJBA20201127017Inverter · inoperativeLT WING EMERGENCY EXIT MARKER INOPERATIVE. R & R NR 4 EMERGENCY LIGHT INVERTER. OPERATIONS CHECK SATISFACTORY, NO FURTHER DEFECTS NOTED.SDR JJBA202004286006Light · inoperativeLH EMERGENCY EXIT LIGHT INOPERATIVE (UPPER LEFT). R&R LH INTERIOR UPPER LEFT EMERGENCY EXIT LIGHT. OPS CHECK SAT.SDR JJBA20200403001Placard · inoperativeSERVICE DOOR FWD EXIT IDENTIFIER EMERGENCY LIGHT INOPERATIVE. R&R SERVICE DOOR FWD EMERGENCY ILLUMINATING PLACARD. OPS CHECK SAT
Back to N17169