N173UP
Service difficulty reports · 215
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N173UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N173UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2026052693472Door · noiseEXTREMELY LOUD SQUEAL EMANATING FROM MAIN DOOR ON AIRCRAFT. SOUND IS COMING FROM AREA OF LOWER DOOR HINGE OR FLOOR. INSTALLED NEW ENTRY DOOR SEAL PER AMM 52-10-18. AWAITING SEALANT CURE TIME AND PRESSURIZATION LEAK CHECK. PERFORMED PRESSURIZATION OF ACFT PER SDR IPXA2026052293472Seal · leakingEXTREMELY LOUD SQUEAL EMANATING FROM MAIN DOOR ON AIRCRAFT. SOUND IS COMING FROM AREA OF LOWER DOOR HINGE OR FLOOR. INSTALLED NEW ENTRY DOOR SEAL PER AMM 52-10-18.SDR IPXA2026011039757Skin · ground damageFUSELAGE DAMAGE FROM PACKAGE CONTAINER AT FRAME 54 STATION 3354 LEFT SIDE PAST HYD. SERVICE DOOR. REF[T3F18E0080U8N]. REQUESTED FAULT BE DERRERD FOR 6 MONTHS IAW EO 96143 REQ1SDR IPXA2026010969701Skin Panel · damagedFUSELAGE DAMAGE FROM PACKAGE CONTAINER AT FRAME 54 STATION 3354 LEFT SIDE PAST HYD. SERVICE DOOR. REPLACEMENT STRINGER WAS FABRICATED IAW SRM 53-10-14 AND EO-96143-PRELIM4 STEP 6.SDR IPXA2025123069701Skin · damagedFUSELAGE DAMAGE FROM PACKAGE CONTAINER AT FRAME 54 STATION 3354 LEFT SIDE PAST HYD. SERVICE DOOR. VERIFY DAMAGE AND REPORT FINDINGS TO SDF LIAISON ENGINEERING PRIOR TO STARTING INITIAL CUTOUT. FOUND 24€? LONG DENT FWD AND AFT OF FRAME 54.2. WIDTH OF DENT MEASSDR IPXA2025101112350Adapter · crackedMAIN DECK-CLS ADAPTER CRACKED FR38.1 BETWEEN -Y1959 AND -Y2462-RT SIDE-109. REMOVED 01 CLS ADAPTER. IAW SRM 51-40-21. INSTALLED CLS ADAPTER. IAW SRM 51-40-21.SDR IPXA2025101448379Skin · crackedFAULT-STR-Z400- #2 ENG PYLON LOWER SPAR LOWER SURFACE LH/RH ANGLE CRACKED PROJECTION RIB 18. DOT 139-2. REMOVED 02 EA ANGLE CRAKED AT #2 ENG PYLON LOWER SPAR LOWER SURFACE LH/RH, IAW A300-600 SRM 51-40-21. INSTALLED NEW 01EA ANGLE SECTION LH P/N A545150632040SDR IPXA2025102037512Thrust Reverser · crackedENGINE NR 1 OTBD THRUST REVERSER INTERNAL STRUCTURE, AFT UPPER CORNER HAD A CRACK. PERFORMED SURFACE HFEC INSPECTION IN THE CRACKED AREA TO THE NR 1 THRUST REVERSER INTERNAL STRUCTURE AFT UPPER CORNER. FOUND AND VERIFIED CRACK WITH AN EST. LENGTH OF 31.75MM (1SDR IPXA2025100313786Stiffener · crackedMDC FLOOR, R/H SIDE, BTW FR 38.1 AND FR 38.2, DOG BONE SUPPORT BROKEN. REMOVED AND REPLACED THE DOG BONE SUPPORT BTW FR 38.1 AND FR 38.2 R/H SIDE IAW SRM 51-40-21.SDR IPXA2025100313780Stiffener · crackedMDC FLOOR, R/H SIDE, BTW FR 37 AND FR 38, DOG BONE SUPPORT BROKEN. REMOVED AND REPLACED THE DOG BONE SUPPORT BTW FR 37 AND FR 38 R/H SIDE IAW A300-600 SRM 51-40-21.SDR IPXA2025102300439Floor Panel · damagedMDC FLOOR PANEL 251 LJ IS DAMAGED. FABRICATION OF PANEL 251LJ IS COMPLETE IAW SREO-16407-REQ001((APPX B) A300 MAIN DECK CARGO COMPARTMENT FLOOR PANEL FABRICATION (SREO)). VERIFIED FABRICATION 251LJSDR IPXA2025101600754Floor Panel · damagedFLOOR PANEL 252 PG IS DAMAGED. FLOOR PANEL 252PG FABRICATION COMPLETED IAW SREO-16407-REQ001.SDR IPXA2025101389818Bracket · gougedLH WING, UPPER SURFACE, WTB, THROUGH FAIRING 577DT, CLOSE TO FALSE REAR SPAR, BRACKET SUPPORT HAS GOUGE. REMOVED BRACKET SUPPORT AT LH WING, UPPER SURFACE, WTB IAW A300-600 SRM 51-40-21. ++INSTALLED NEW BRACKET IAW A300-600 SRM 51-40-21.SDR IPXA2025100383584Fairing · damagedR/H WING, KRUEGER MOVABLE VANE, EXTERNAL LOWER O/B SKIN WITH GOUGE. REMOVED GAUGE ON EXTERNAL SKIN R/H KRUEGER IAW SRM 51-73-10, ORIGINAL THICKNESS .090", REMAINING THICKNESS .065", MAX MATERIAL LOSS .025" FOUND OUT OF LIMITS IAW A300-600 SRM 51-73-11. REMOVESDR IPXA2025100383586Fairing · gougedFAULT - STR - Z600 - R/H WING, KRUEGER MOVABLE VANE, EXTERNAL LOWER CENTER SKIN WITH GOUGE.REMOVED GAUGE ON EXTERNAL SKIN R/H KRUEGER IAW A300-600 SRM 51-73-10.RECEIVED SERVICEABLE RH KRUEGER FLAP FOLDING FAIRING P/N: A5351028500500 AND IT IS APPLICABLE TO USESDR IPXA2025100383592Skin · gougedR/H WING, KRUEGER MOVABLE VANE, INTERNAL STRUCTURE, INBOARD LOWER SECTION WITH GOUGE.REMOVED GOUGE ON INTERNAL STRUCTURE SKIN R/H KRUEGER IAW A300-600 SRM 51-73-10.RECEIVED SERVICEABLE RH KRUEGER FLAP FOLDING FAIRING P/N: A5351028500500 AND IT IS APPLICABLE TOSDR IPXA2025100383981Skin · damagedRIGHT KRUEGER MOVABLE VANE, EXTERNAL SKIN WITH SCRATCH.EMOVED SCRATCH ON EXTERNAL SKIN R/H KRUEGER IAW A300-600 SRM 51-73-10.RECEIVED SERVICEABLE RH KRUEGER FLAP FOLDING FAIRING.INSTALLED R/H WING, KRUEGER FLAP MOVABLE VANE I.A.W. A300 AMM 27-87-12/401SDR IPXA2025101047419Floor Panel · brokenMDC, LT SIDE, FLOOR PANEL 241EF, LOWER SURFACE HAS AFT EDGE DAMAGED. FLOOR PANEL 241EF FABRICATION COMPLETE IAW SREO-16407-REQ001.SDR IPXA2025101546777Bracket · crackedFWD CARGO, FR 38.2, BULKHEAD PANEL UPPER SUPPORT HAS BRACKETS CRACKED (6EA). SAW THROUGH FLOOR PANELS). REMOVED (6EA) BRACKETS SUPPORT I.A.W SRM 51-40-21. INSTALLED 6 EA NEW BRACKETS IAW A300-600 SRM 51-40-21.SDR IPXA2025101647392Floor Panel · damagedMDC, LH SIDE, FLOOR PANEL 241HF HAS INSERT OUT OFF POSITION AND LOWER SURFACE DAMAGED. FLOOR PANEL 241HF FAB COMPLETED IAW SREO-16407-REQ001.SDR IPXA2025101046801Adapter · corrodedMDC, LH SIDE, FLOOR AREA, FR36 HAS CLS ADAPTER BROKEN (BY CORROSION). DOT 103-41. REMOVED 01 CLS ADAPTER. IAW SRM 51-40-21. IAW STEP 9. INSTALLED CLS ADAPTER. IAW SRM 51-40-21.SDR IPXA2025100848616Floor Panel · damagedMDC, LH SIDE, FLOOR PANEL241BF, LOWER SURFACE HAS A PUCTURE AND MATERIAL DAMAGED. DOT 103-52 JOB COMPLETEDSDR IPXA2025100847419Floor Panel · damagedMDC, LH SIDE, FLOOR PANEL 241EF, LOWER SURFACE HAS AFT EDGE DAMAGED. DOT 103-48 APPROVEDSDR IPXA2025100251097Support · brokenMDC, LH SIDE, FLOOR PANEL241BF, LOWER SURFACE HAS A PUCTURE AND MATERIAL DAMAGED. FLOOR PANEL 241BF FABRICATION COMPLETE IAW SREO-16407-REQ001.SDR IPXA2025101631355Floor Panel · damagedFAULT: INT-200- MCC FLOORBOARD 232SG HAS DAMAGE. 33-035. FLOOR PANEL 232SG FAB COMPLETED IAW SREO-16407-REQ001 FLOOR PANEL MATERIAL P/N 5024N400001SS-G B/N 0004055277 QTY-1 TOP INSERTS P/N G2001B-3P B/N 0004418941 QTY-50 BOTTOM INSERTS P/N PG2002B-3S B/N 0004SDR IPXA2025101631583Floor Panel · damagedFAULT: INT-200- MCC FLOORBOARD 232WG HAS AN OVERSIZE SCREW HOLE. 33-038. FLOOR PANEL 232WG FAB COMPLETED IAW SREO-16407-REQ001 FLOOR PANEL MATERIAL P/N 5024N400001SS-G B/N 0004055277 QTY-1 TOP INSERTS P/N G2001B-3P B/N 0004418941 QTY-50 BOTTOM INSERTS P/N PGSDR IPXA2025101539416Bracket · crackedFAULT-STR-ZONE 300. VERTICAL STAB, FIN TO FUSELAGE FAIRING AREA, LH #2 UPPER PANEL SUPPORT BRACKET (1EA) BROKEN. REMOVED THE BROKE UPPER BRACKET AT 300. VERTICAL STAB, FIN TO FUSELAGE FAIRING AREA, LH IAW A300-600 SRM 51-40-21 IT. ++INSTALLED SUPPORT BRACKESDR IPXA2025101339189Bracket · crackedVERTICAL STAB, FIN TO FUSELAGE FAIRING AREA, RH #3 PANEL SUPPORT BRACKET (1EA) BROKEN. REMOVED SUPPORT BRACKET (1EA)I.A.W A300-600 SRM 51-40-21. ++INSTALLED NEW PART IAW A300-600 SRM 51-40-21. RIVET P/N CR3213-4-06, BATCH #0004279158, QTY 2EASDR IPXA2025101046481Adapter · brokenMDC, LH SIDE, FLOOR AREA, THROUGH PANEL 241YK, BTWN FR38.1 TO 38.2 HAS CLS ADAPTER BROKEN (BY CORROSION). REMOVED 02 EA CLS ADAPTER LOCATED IN FR38.1 AND FR38.2. IAW SRM 51-40-21. IAW STEP 9. INSTALLED 02 EA CLS ADAPTERS. IAW SRM 51-40-21.SDR IPXA2025101031266Floorboard · brokenMCC FLOOR BOARD 231MJ IS BROKEN. 33-033. FLOOR BOARD 231MJ FABRICATION COMPLETE IAW SREO-16407-REQ 001 INSERT QUANTITY 40 INSERT, EDGE FILL, KIT INSERT GLUE. MAJOR.SDR IPXA2025100931224Floor Panel · damagedMCC FWD FLOORBOARD 221CG HAS FWD EDGE DAMAGE. 33-032. FLOOR PANEL FABRICATION COMPLETE IAW SREO-16407-REQ001.SDR IPXA2025100236550Angle · crackedFR 80, BTW -Y1137.1 AND -Y1580.5, Z ANGLE WITH CRACK.REMOVED AND REPLACED PROFILE-T P/N A53988140120100 BATCH 0004429452, AT MDC, FR 80, BTW -Y1137.1 AND -Y1580.5, IAW A300-600 SRM 51-40-21SDR IPXA2025100638930Fitting · crackedMAIN DECK FLOOR STRUCTURE, FR 10, -Y1456, FITTING PICK-UP WITH CRACK.REMOVED FITTING IN MAIN DECK FLOOR STRUCTURE, FR 10, -Y1456. IAW AIRBUS A300-600 SRM 51-40-21.FABRICATED, LOCATED AND DRILL NEW FITTING PICK-UP P/N: 2024-T3 .063, BATCH: 0004410262 IAWAIRBUSASDR IPXA2025100346608Support · crackedMDC, LH SIDE, FLOOR AREA, FR38.1 TO FR38.2 HAS CROSS WEB (DOG BONE) BROKEN. DOT 103-39.REMOVED SUPPORT CROOS WEB (DOG BONE) LOCATED AT Z200, MDC, LH SIDE, FLOOR AREA, FR38.1 TO FR38.2 IAW A300-600 SRM 51-40-21.RECEIVED NEW CROSS WEB (DOG BONE) IAW A300-600 SRMSDR IPXA2025100431410Stiffener · crackedRIGHT MAIN DECK DOG BONE IS LOOSE BETWEEN FR 37-38. REPLACED DOG BONE BETWEEN FR 37-38 IAW SRM 51-40-21.SDR IPXA2025100431378Stiffener · crackedRIGHT MAIN DECK DOGBONE BROKEN AT FR 38.1 - 38.2. REPLACED DOG BONE BETWEEN FR 38.1 - 38.2 IAW SRM 51-40-21.SDR IPXA2025102108625Door · damagedCREW DOOR, EXTERNAL HANDLE INNER SIDE, LOWER EDGE HAS A GOUGE. REMOVED MINOR GOUGE AT CREW DOOR, EXTERNAL HANDLE INNER SIDE, LOWER IAW SRM 51-73-10 AND ORIGINAL THICKNESS IS 0.135" AND MATERIAL LOSS IS 0.001 AND REMAINING THICKNESS IS 0.134" AND FOUND WITH ISDR IPXA2025102125858Skin · damagedCREW DOOR, EXTERNAL SURFACE, ALONG OF THE FWD EDGE HAS BARE METAL. PREPPED AND PAINTED CREW DOOR EXTERNAL SURFACE ,ALONG OF THE FWD EDGE IAW SRM 51-75 10.SDR IPXA2025102126197Rail · damagedCREW DOOR CUT-OUT, FWD AND AFT FRAMES, ROLLER RAILS (4EA) HAVE GOUGES. REMOVED MINOR GOUDES AT FWD AND AFT FRAMES, ROLLER RAILS (4EA) IAW SRM 51-73-10 AND THE ORIGINAL THICKNESS IS 0.095" AND MATERIAL LOSS 0.002 AND REMAINING THICKESS IS 0.093" AND FOUND WITHSDR IPXA2025101613715Floor Panel · damagedMAIN DECK FLOOR PANEL 251DN, CORNER DAMAGED. FLOOR PANEL 251CN FAB COMPLETED IAW SREO-16407-REQ001 FLOOR PANEL MATERIAL P/N 5024N400001SS-G B/N 0004055277 QTY-1 TOP INSERTS P/N G2001B-3P B/N 0004418941 QTY-50 BOTTOM INSERTS P/N PG2002B-3S B/N 0004392380 QTY-5SDR IPXA2025101622483Floor Panel · damagedMAIN DECK FLOOR PANEL 251CN HAS COMPOSITE DAMAGE. PANEL 251CN FABRICATION COMPLETED IAW SREO-16407-REQ001 FLOOR PANEL MATERIAL P/N 5024N400001SS-G B/N 0004055277 QTY1 TOP INSERT P/N G2001B-3P B/N 0004418941 QTY 50 BOTTOM INSERT P/N G2002B-3S B/N 0004392380 QTSDR IPXA2025101522450Adapter · brokenMDC FLOOR STRUCTURE, FR 63, -Y1959 HAS CLS ADAPTER BROKEN.. REMOVED CLS ADAPTER AT MDC FLOOR STRUCTURE, FR 63, -Y1959, IAW SRM 51-40-21. ACCOMPLISH PERMANENT REPAIR IAW EO-95271-REQ1 AND VT-MAE EA 300-5317-27-A4164.SDR IPXA2025101513883Adapter · corrodedMDC FLOOR, FR 59, BTW Y0 AND -Y450, CLS ADAPTER CORRODED. REWORKED CLS ADAPTER AT FR59 BTW Y0 AND Y-450 BY TOOL AND IS OUT OF LIMITS. ACCOMPLISHED STEP 11 EA#300-5317-27-A4163 PRELIMINARY 1. INSTALL CLS ADAPTER PER DRAWING A53275514.SDR IPXA2025101022102Crossbeam · bentMDC, FR 48, BTW -Y450 AND -Y953, CROSSBEAM BENT. CROSSBEAM REMOVED AND REPLACED IAW A300-600 SRM51-72-10, SRM51-40-21.SDR IPXA2025101022100Crossbeam · bentMDC, FR 49, BTW -Y450 AND -Y953, CROSSBEAM BENT. CROSSBEAM REMOVED AND REPLACED IAW A300-600 SRM51-72-10, SRM51-40-21.SDR IPXA2025101022072Crossbeam · bentMDC, FR 50, BTW -Y450 AND -Y953, CROSSBEAM BENT. CROSSBEAM REMOVED AND REPLACED IAW A300-600 SRM51-72-10, SRM51-40-21.SDR IPXA2025101021115Crossbeam · crackedMDC, FR 51, BTW -Y450 AND -Y953, CROSSBEAM CRACKED. CROSSBEAM REMOVED AND REPLACED IAW A300-600 SRM51-72-10, SRM51-40-21.SDR IPXA2025101023459Floorboard · delaminatedMAIN DECK FLOOR PANEL 241JN DELAMINATED. FLOOR BOARD 231MJ FABRICATION COMPLETE IAW SREO-16407-REQ00.SDR IPXA2025101022355Floorboard · damagedMAIN DECK FOOR PANEL 262GH EDGE DAMAGED. FLOOR BOARD 262GH FABRICATION COMPLETE IAW SREO-16407-REQ001. MAJOR REPAIR.SDR IPXA2025100122455Floor Support · crackedFAULT - STR - Z200 - MDC FLOOR STRUCTURE, FR 74, -Y2127.5 Z ANGLE CRACKED DOT 1/026.REMOVED Z-PROFILE AT MDC FLOOR STRUCTURE, FR 74, -Y2127.5, IAW A300-600 SRM 51-40-21.FABRICATED NEW Z-PROFILE, IAW A300-600 SRM 53-18-18 AND GMM 09-08-01-04.INATALLED NEW Z-PRO
Back to N173UP