N174US
Service difficulty reports · 380
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N174US' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N174US' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA202111097431Slide · failedAIRCRAFT IN BASE MAINTENANCE: EMERGENCY LIGHT CHECK FAILED ON PTP PANEL. REMOVED AND REPLACED L1 DOOR SLIDE.SDR AALA202111089077Coupling · wornAIRCRAFT IN BASE MAINTENANCE: AFT LEFT HAND INBOARD SEAT TRACK AFT UPPER COUPLING HAS PRE-EXISTING ELONGATED HOLES AT BS 38750 AND S23L. REPLACED COUPLING PER ECO 2518E208-018.SDR AALA202111057821Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: MAIN CABIN FLOOR PANEL 252BG HAS SURFACE DELAMINATION. REPLACED FLOOR PANEL PER SRM 53-12-00-300-006.SDR AALA202111017822Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: MAIN CABIN FLOOR PANEL 232XF HAS SURFACE DELAMINATION. REPLACED FLOOR PANEL PER SRM 53-12-00-300-006.SDR AALA202111011550Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: MAIN CABIN FLOOR PANEL 251AG HAS SURFACE DELAMINATION. REPLACED FLOOR PANEL PER SRM 53-12-00-300-006SDR AALA202111010620Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: MAIN CABIN FLOOR PANEL 232GJ HAS SURFACE DELAMINATION. REPLACED FLOOR PANEL PER SRM 53-12-00-300-006.SDR AALA202111015472Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: MID CABIN FLOOR PANEL 231SFF HAS SURFACE DELAMINATION. REPLACED FLOOR PANEL PER AMM 53-00-00-400-801A.SDR AALA202110277832Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: CABIN FLOOR PANEL 241KF HAS DELAMINATION. REPAIRED FLOOR PANEL PER SRM 53-02-00-300-013.SDR AALA202110273538Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: CABIN FLOOR PANEL 231QF HAS DELAMINATION. REPAIRED FLOOR PANEL PER SRM 53-02-00-300-013.SDR AALA202110016133Connector · looseAIRCRAFT WAS NOT GROUNDED: 3R DOOR CABIN PRESSURE LIGHT FLASHING RED INTERMITTENTLY DURING FLIGHT. **SUPPLEMENTAL REPORT: ADJUSTED BACKSHELL ON WIRING CONNECTOR IAW ESPM 20-33-45, OPS CHECK GOOD.** (CLOSED)SDR AALA202109246133None · noneAIRCRAFT WAS NOT GROUNDED: 3R DOOR CABIN PRESSURE LIGHT FLASHING RED INTERMITTENTLY DURING FLIGHT. **SUPPLEMENTAL REPORT WILL BE SUBMITTED.** (OPEN)SDR AALA202108182355Battery · faultedAIRCRAFT WAS NOT GROUNDED: EMERGENCY POWER SUPPLY UNIT 10WL BATTERY FAULT. REPLACED BATTERY PER AMM 33-51-3.SDR AALA202108180449Connector · brokenAIRCRAFT WAS NOT GROUNDED: BROKEN CANNON PLUG ON EMERGENCY LIGHT LAST SEAT ROW, LEFT HAND SIDE. REPLACED CABLE FOR EMERGENCY LIGHT PER AMM 33-51-19 AND ESPM 20-33-45.SDR AALA202108187718Battery · faultedAIRCRAFT WAS NOT GROUNDED: EMERGENCY POWER SUPPLY 11WL BATTERY FAULT. REPLACED BATTERY PER AMM 33-51-3.SDR AALA202108185849Battery · faultedAIRCRAFT WAS NOT GROUNDED: EMERGENCY POWER SUPPLY UNIT 15WL BATTERY FAULT. REPLACED BATTERY PER AMM 33-51-3.SDR AALA202108188894Battery Pack · defectiveAIRCRAFT WAS NOT GROUNDED: THE L4 SLIDE WAS REPLACED AND DURING THE POST INSTALLATION FUNCTIONAL CHECK OF THE EMERGENCY ESCAPE LIGHTING SYSTEM MULTIPLE FAULTS OCCURRED FOR THE EMERGENCY POWER SUPPLY UNIT BATTERIES AT THE LEFT MID FORWARD, LEFT EXIT AND LEFT AFSDR AALA202108188222Battery Pack · defectiveAIRCRAFT WAS NOT GROUNDED: THE L4 SLIDE WAS REPLACED AND DURING THE POST INSTALLATION FUNCTIONAL CHECK OF THE EMERGENCY ESCAPE LIGHTING SYSTEM MULTIPLE FAULTS OCCURRED FOR THE EMERGENCY POWER SUPPLY UNIT BATTERIES AT THE LEFT MID FORWARD, LEFT EXIT AND LEFT AFSDR AALA202108182998Battery Pack · defectiveAIRCRAFT WAS NOT GROUNDED: THE L4 SLIDE WAS REPLACED AND DURING THE POST INSTALLATION FUNCTIONAL CHECK OF THE EMERGENCY ESCAPE LIGHTING SYSTEM MULTIPLE FAULTS OCCURRED FOR THE EMERGENCY POWER SUPPLY UNIT BATTERIES AT THE LEFT MID FORWARD, LEFT EXIT AND LEFT AFSDR AALA202108188309Connector · brokenAIRCRAFT WAS NOT GROUNDED: THE L4 SLIDE WAS REPLACED AND DURING THE POST INSTALLATION FUNCTIONAL CHECK OF THE EMERGENCY ESCAPE LIGHTING SYSTEM MULTIPLE FAULTS OCCURRED FOR THE EMERGENCY POWER SUPPLY UNIT BATTERIES AT THE LEFT MID FORWARD, LEFT EXIT AND LEFT AFSDR AALA202012109012Battery Pack · inoperativeAIRCRAFT WAS NOT GROUNDED. 2L FLASHLIGHT BATTERY IS DEAD. REPLACED FLASHLIGHT WITH SERVICEABLE UNIT. OPERATIONS CHECK GOOD.SDR AALA202012089003Power Supply · no testAIRCRAFT WAS NOT GROUNDED. FOUND EMERGENCY POWER SUPPLY UNIT 13WL BATTERY FAULT. REMOVED AND REPLACED EMERGENCY POWER SUPPLY UNIT, IAW AMM 33-51-38.SDR AALA2020091549002Power Supply · no testAIRCRAFT IN BASE MAINTENANCE, EMERGENCY LIGHT BITE CHECK. FAULT: EPSU BATTERY AFT LT. REMOVED AND REPLACED LEFT AFT EPSU (EMERGENCY POWER SUPPLY UNIT) 13WL, PER AMM 33-51-38. OPERATIONAL CHECK GOOD.SDR AALA2020070549006Floor Panel · damagedAIRCRAFT GROUNDED - FORWARD CARGO FLOOR PANEL 131EF SPONGY. REMOVED AND REPLACED FLOOR PANEL 131EF PER AMM 53-22-14.SDR AALA202002069017Housing · detachedAIRCRAFT NOT GROUNDED: DOOR 4R SLIDE HOUSING NOT PROPERLY ATTACHED. SECURED SLIDE COVER AT DOOR 4R IAW AMM 25-62-50.SDR AALA201911159003Floor Panel · delaminatedAIRCRAFT WAS NOT GROUNDED: AFT CARGO COMPARTMENT FLOOR PANEL 151GF DELAMINTED. REPLACED FLOOR PANEL PER AMM 53-42-14.SDR AALA201905149015Battery · dischargedAIRCRAFT WAS NOT GROUNDED: EMERGENCY FLASHLIGHT INOPERATIVE AFT. MAINTENANCE REPLACED FLASHLIGHT BATTERY AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR AALA201904259004Light · inoperativeAIRCRAFT WAS NOT GROUNDED: DOOR L4 EXIT SIGN ABOVE DOOR INOPERATIVE. MAINTENANCE REPAIRED EXIT LIGHT PER AMM 33-51-16-400-001-A AND PERFORMED SATISFACTORY OPERATIONAL CHECK.SDR AALA2019042329019Power Supply · inoperativeAIRCRAFT IN BASE VISIT: MAINTENANCE FOUND INOP EPSU-EMERGENCY POWER SUPPLY UNIT 14WL IN PASSENGER CABIN. REPLACED EMERGENCY POWER SUPPLY UNIT (14WL) IN PASSENGER CABIN IAW AMM 33-51-38-400-001-A. BITE TEST IS OK.SDR AALA201904029019Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: AFT GALLEY FLOOR PANEL 261PF DELAMINATED. REPLACED FLOOR PANEL PER SRM 53-02-00-300-011.SDR AALA201904029018Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE. FORWARD GALLEY FLOOR PANEL 221DF DELAMINATED. REPLACED FLOOR PANEL PER SRM 53-12-00-300-006.SDR AALA201904019035Support Angle · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED AFT CARGO COMPARTMENT SUPPORT ANGLE LOCATED AFT FACE OF PRESSURE BULKHEAD FR 47 AND S38L. REPLACED SUPPORT ANGLE PER SRM 51-42-11 AND 51-72-11.SDR AALA201904019034Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: AFT GALLEY FLOOR PANEL 261AG DELAMINATED. REPLACED FLOOR PANEL PER SRM 53-02-00-300-011.SDR AALA201904019033Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: FORWARD GALLEY FLOOR PANEL 231FF DELAMINATED. REPLACED FLOOR PANEL PER SRM 53-12-00-300-006.SDR AALA201904019032Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENANCE: FORWARD GALLEY FLOOR PANEL 221EF DELAMINATED. REPLACED FLOOR PANEL PER SRM 53-12-00-300-006.SDR AALA201904019031Floor Panel · delaminatedAIRCRAFT IN BASE MAINTENACE: AFT GALLEY FLOOR PANEL 261BG DELAMINATED. REPLACED FLOOR PANEL PER SRM 53-02-00-300-011.SDR AALA201904169024Hinge Fitting · wornAIRCRAFT IN BASE MAINTENANCE: RIGHT HAND ELEVATOR #1 HINGE HAS EXCESSIVE PLAY / WORN. REPLACED HINGE PER AMM 55-16-42-400-001-A.SDR AALA2019041659037Hinge Arm · wornAIRCRAFT IN BASE MAINTENANCE: RIGHT HAND ELEVATOR #4 HINGE ARM HAS EXCESSIVE PLAY / WORN. REPLACED HINGE ARM PER AMM 55-16-42-400-001-A.SDR AALA201904159036Hinge Arm · wornAIRCRAFT IN BASE MAINTENANCE: RIGHT HAND ELEVATOR #5 HINGE ARM HAS EXCESSIVE PLAY / WORN. REPLACED HINGE ARM PER AMM 55-16-42-400-001-A.SDR AALA201904019013Hinge Fitting · wornAIRCRAFT IN BASE MAINTENANCE: RIGHT HAND ELEVATOR HINGE FITTING HAS EXCESSIVE PLAY AND IS WORN. REPLACED HINGE FITTING PER AMM 55-16-42-400-001-A.SDR AALA2019042429027Door Sill · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON LOWER SILL AT FR 66 AND S23L. REPAIRED LOWER SILL PER SRM 53-41-14-300-001 REPAIR PRINCIPLAL 6.SDR AALA201904169015Stop Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED DOOR STOP FITTING AT FR 20 LEFT HAND SIDE AT THE #7 DOOR STOP AREA. REPLACED DOOR STOP FITTING PER EA 291773.SDR AALA201904169014Frame · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED FRAME AT FR 20 LEFT HAND SIDE AT THE #7 DOOR STOP AREA. REPAIRED FRAME PER EA 291773.SDR AALA2019041659047Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED FITTING AT FR 16 BETWEEN S10R AND S11R. REPLACED FITTING PER SRM 51-72-11.SDR AALA2019041659046Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED INTERCOSTAL FITTING AT FR 16 AND S22L. REPLACED INTERCOSTAL FITTING PER SRM 51-72-11.SDR AALA2019041659045Fitting · crackedAIRCRAFT IN BASE MAINTENANCE: CRACKED INTERCOSTAL FITTING AT FR 16 AND S10L. REPLACED INTERCOSTAL FITTING PER SRM 51-72-11.SDR AALA2019041659038Floor Support · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT GALLEY FLOOR BEAM BETWEEN FR 68 AND FR 70 AT -Y160. REPLACED FLOOR BEAM PER SRM 51-72-11.SDR AALA201903289019Floor Support · corrodedCORROSION FOUND ON THE AFT GALLEY FLOOR SUPPORT, FRAME 66, +Y1225. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11.SDR AALA201903289018Floor Support · corrodedCORROSION FOUND ON THE AFT GALLEY FLOOR SUPPORT BETWEEN FRAMES 65 AND 66, +Y1732. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11.SDR AALA201903289017Floor Support · corrodedCORROSION ON THE AFT GALLEY FLOOR SUPPORT BETWEEN FRAMES 66 AND 70, +Y765. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11.SDR AALA201903279027Floor Support · corrodedCORROSION FOUND ON THE AFT GALLEY FLOOR SUPPORT BETWEEN FRAMES 66 AND 70. -Y765, STRINGER 23R. REPLACED THE FLOOR SUPPORT IAW SRM 51-72-11.
Back to N174US