N210UA
Service difficulty reports · 205
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N210UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N210UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2013101592056Strip · brokenMID GALLEY FWD RT SIDE TERMINAL STRIP THAT HOLDS EMERGENCY EXIT LIGHT WIRING IS BROKEN & HANGING DOWN. SECURED TO BASE.SDR CALA2013101191960Seal Depressor · damagedDURING LOADING AFT CARGO, LOWER FWD SEAL DEPRESSOR DAMAGED, APPROXIMATELY 33 INCHES ABOVE FWD LOWER CORNER CRACKED APPROXIMATELY 1 INCH, ANOTHER 1 INCH CRACK LOCATED AN INCH & QUARTER ABOVE THAT. TEMP REPAIR IAW ECRA 5237 01002.SDR CALA2013100391713Fuel Sys · malfunctionedPRIOR TO DISPATCH, APU AUTOSHUT DOWN, TRIED TO RESTART, APU WOULD NOT RESTART. CHECKED OIL LEVEL, FOUND GOOD. MESSAGE 49-10420 FUEL CLUSTER SHUTOFF SOLENOID CIRCUIT IS OPEN. REPLACED FUEL CLUSTER IAW MM.SDR CALA2013092491415Headset · defectiveCAPTAIN`S HEADSET WONT TRANSMIT. REPLACED WITH SPARE HEADSET, SPARE WORKS OK. REPLACED SPARE MINITEL.SDR CALA2013092391341Probe · faultyRT TANK INDICATED 3000 LBS LOW FOR AN EXTENDED PERIOD OF TIME BEFORE RETURNING TO NORMAL. SNAPSHOT OF EVENT SHOWED PROBES 14 & 16 IN RT TANK INDICATING 0 VS LT TANK OF 5.4 & 19.1. AFTER FUEL QUANTITY RETURNED TO NORMAL NR 16 PROBE INDICATED SIMILAR TO RT SIDSDR CALA2013090991116Repair · debondedNR 2 ENGINE INTAKE RUB STRIP-5 O'CLOCK POSITION. PREVIOUS REPAIR DISBONDED LESS THAN 3 INCHES. CARRIED FWD IAW THE AMM & TOMC FOR 500 HOURS OF 200 CYCLES. IF UNABLE TO REPAIR PLEASE UPDATE WITH TIME & PARTS REQUIRED.SDR CALA2013082290655Unknown · malfunctionedCENTER FUEL SLOWLY GAINS FUEL TO 300 LBS WITH PUMPS OFF. ACP FUEL SCAVENGE SYSTEM FUNCTION TEST PER AMM. NEED 24K ON EACH MAIN TANK & 1K-13200 ON CENTER TANK TO COMPLETE TEST. DURING TEST ITEM 'E' PG 525, ITEM E(3B), LEFT MAIN TANK HAD NO INCREASE OF FUEL WHISDR CALA2013081690485Line · leakingNR 1 ENG HYD LEAK COMING FROM RT PYLON J-BOX AREA, RT SIDE OF ENG HAS HEAVY COKING. OPENED HYD RACEWAY INSULATION BLANKET. DRY-MOTORED NR 1 ENG FOUND 3 DROPS IAW MINUTE HYD LEAK FROM HYD PRESSURE HOSE (AFT HOSE) AT J-BOX CONNECTION. REPLACED HYD PRESSURE LSDR CALA2013080690176Hose · crackedFOUND ICE BUILD UP INSIDE WING TO BODY FAIRINGS ABOVE FWD DRAIN MAST. REPLACED CRACKED HOSE ATTACHED TO FWD DRAIN MAST. LEAK CHECKED OK, MAST HEATER TESTED OK.SDR UALA2013071705013Access Panel · damagedDURING WALKAROUND, FOUND FUEL LEAK FROM RT WING. LEAK WAS COMING FROM IMPACT. REPLACED FUEL TANK ACCESS DOOR IAW MM, NO LEAK FOUND. ROOT CAUSE: MAINT ONLY. REMARKS: RT WING 1 IMPACT PANEL HAS FUEL LEAK. REPLACED PANEL.SDR UALA2013071605002Starter · making metalNR 2 ENGINE STARTED, HAS OIL CONTAMINATION AND METAL PARTICLES ON STARTER MCD. REPLACED NR 2 ENGINE STARTER.SDR UALA2013071605001Flex Hose · deterioratedNR 2 ENGINE LPT-HPT, TCC, ACC COOLING FLEX HOSE ( AT 3 O'CLOCK POS) DETERIORATED. HOSE BRANCHES OFF THE IGN COOLING DUCT. REPLACED TUBE ASSY.SDR UALA2013071204873Control Valve · failedRIGHT PACK LOWER FLOW CONTROL VALVE FAILED. PACK VALVE FAILED IN OPEN POSITION AND "OFF" LIGHT NOT ILLUMINATED WITH PACK SELECTED "OFF". RT PACK LOWER FLOW CONTROL VALVE. OPS AND LEAK CKS GOOD.SDR UALA2013052203554Control System · inoperativeAFT GALLEY FLOOR TEMP CONTROL INOPERATIVE.SDR UALA2013050103051Hose · leakingRIGHT MLG OTBD FRONT BRAKE HOSE LEAKING HYDRAUIC FLUID. REPLACED HOSE ASSY, CHECKED OKAY.SDR UALA2013041002439Minitel · crackedCAPT MINITEL HAS CRACKED OUTER SHEATH NEAR HEADSET. REPLACED CAPT SIDE MINITEL AND OP'S CHECKED GOOD PER AMM.SDR UALA2013040902359Unknown · malfunctionedSTATUS MSG OUTFLOW VALVE LEFT. OUTFLOW VALVE AFT AUTO CONTROL ON AFT OUTFLOW VALVE FAILED. STATUS MSG03- NOT ACTIVE CLIMB INTERMITTENT; OUTFLOW VALVE CONTROL UNIT (AFT) OR ECU (R, AFT) HAS NO OUTPUT ON ARINC 429 BUS OR OUTPUT IS INCORRECT. DB- AIR SUPPLY & SDR UALA2013040502278Outflow Valve · failedOUTFLOW VALVE AFT AUTO CONTROL ON AFT OUTFLOW VALVE FAILED. REPLACED AFT OUTFLOW VALVE ACTUATOR ASSY IAW MM 21-31-03 TASK 21-31-03-400-818-001. OPS CHECKED GOOD. FAULT REOCCURED. MESSAGE 21-39490, RANG OUT WIRING FROM R ASCPC TO AFT OUTFLOW VALVE CONNECTOSDR UALA2013040202165Control Switch · faultyTEMP CONTROL FOR AFT GALLEY FLOOR LOOSE. CONFIRMED THAT THE GALLEY HEATER SWITCH IS BAD. PULLED AND CAPPED C-B. REPLACED CONTROL SWITCH ASSY, TESTED GALLEY HEATING SYSTEM.SDR UALA2013040202163Converter · faultyREPACEL LEFT OZONE CONVERTER. REPLACED O-ZONE CONVERTER PER EQ CALL OUT.SDR UALA2013040202160Converter · faultyREPLACE RIGHT O-ZONE CONVERTER.SDR UALA2013040102059Door · out of positionE&E DOOR CAME OFF THE TRACK WHEN CLOSING. SECURED DOOR BACK ON TRACK, OPS NORMAL.SDR UALA2013032802014Valve · faultyAPU BLEED AIR STATUS MESSAGE. REPLACED SURGE VALVE AND CLEARED MESSAGE. BLEED AIR OPS NORMAL.SDR UALA2013031101451Solenoid Valve · faultyRIGHT GEAR DOOR WILL NOT CLOSE USING GROUND CONTROL SWITCH. REPLACED SAFETY SOLENOID VALVE, OPS CHECKED NORMAL. NO LEAKS NOTED. SERVICED HYD FLUID.SDR UALA2012120707112Life Vest · missingCBN SVC REPORTS: 40E LIFE VEST MISSING. REPLACED LIFE VEST.SDR UALA2012112806824Connector · faultyWHEN LAV SERVICE DUMPED LAVS FOUND WASTE STEAMS OUT OF BLOWER VENT. NR 1 BLOWER CONT RUNS, PULLED CB & HAD NORMAL SERVICE. NR 1 LAV BLOWER CONTINUOUSLY RUNS. REPLACED CONNECTOR DS38008 REF WD 38-32-11. OPS CHECK OKAY.SDR UALA2012111906653Jack · shortedLOUD HUMMING NOISE HEARD ON FLT & SVC INTERPHONE SYS IN FLT DECK -- IT WILL NOT RESET. ORDERED "AUDIO MANAGEMENT UNIT" MR23508. TRIED NEW "AUDIO MANAGE- MENT UNIT", ISOLATING AUDIO PANELS, O2 PANELS. MICS, HEADSET ASSEMBLIES IN FLT DECK -- STILL NO HELP. RSDR UALA2012101005767Charger · faultyNO LAND 3 EICAS MSG. OP CHECKED OK AND NO FAULTS. PER FLIGHT CREW BATTERY MSG HAS APPEARED, REPLACED MAIN BATTERY CHARGER.SDR UALA2012100905732Panel · damagedDURING REMOVAL OF PANEL FOR DEFECT DISTURBED 3 EACH EEL LIGHTS ALONG WALL NEAR 2 RIGHT MED. AFT RT SIDE OF MID GALLEY WALL HAD A 1' BY 2' GAUGE AND DELAMINATED AREA. 2 AREA OF DAMAGE ARE 2 FOOT LONG 1-4IN WIDE AND OTHER 6INCH LONG BY 1-4IN WIDE. COSMETIC DASDR UALA2012100405624Idg · faultyRIGHT GENERATOR "DRIVE" LIGHT INOP ON RIGHT IDG DISCONNECT SWITCH AND ELECTRICAL SYNOPTIC PAGE. PARTS ON BOARD AT BULK PIT. SUSPECT BAD IDG. REPLACED RIGHT IDG PER MM. LEAK, AND OPS CHECKS NORMAL, DRIVE LIGHT OPS NORMAL, SYNOPTIC PG DATA NORMAL.SDR UALA2012091305159Connector · not seatedF/O'S RADIO TUNING PNL "HF-AM" LIGHT STUCK ON, "VHF-L" & "VHF-R" BUTTON LIGHTS DO NOT ILLUMINATE WHEN SELECTED. TRIED SWAPPING PNLS AND RESET AIMS CPM-COMM, NO HELP. RESEATED CONN, OPS-CHECKED NORMAL.SDR UALA2012081304380Apu · smokeAPU AUTO SHUTDOWN AT GATE, SMOKE FROM TAILPIPE IMMEDIATELY AFTER SHUTDOWN. INSPECTED APU, FOUND DAMAGE TO FIBERGLASS SHROUD BELOW COMPRESSOR SCREEN. INSPECTED APU COMPARTMENT FOR DAMAGE, FOUND NONE, TAILPIPE WAS CLEAN, APU ACCESS DOORS CLOSE AND LATCH NORMALSDR UALA2012073004112Pump · leakingRIGHT MAIN WHEEL WELL, ALTERNATING CURRENT HYD MOTOR PUMP (FWD C1) IS LEAKING STEADILY FROM FLANGE. REPLACED C1 ACMP PER AMM.SDR UALA2012072404016Sensor · failedHYD TEMP INDICATOR PRI C2 FAILED. REPLACED TEMP SENSOR OPS CHECKED GOOD PER FIM 29-11 TASK 897.SDR UALA2012071203771Feeder Cable · damagedNR 2 ENGINE IDG FEEDER CABLES HAVE BURNED AND SPLIT SHRINK WRAP INSULATION AT IDG TERMINAL ENDS. REPLACED LEFT ENGINE IDG POWER FEEDER CABLES FROM ENGINE IDG TO ENGINE MOUNTED TERMINAL STRIP PER AMM. REPLACED RIGHT ENGINE IDG POWER FEEDER CABLES FROM RT ENG SDR UALA2012071103707Converter · failedFAILURE IN THE BACKUP ELECTRICAL SYSTEM HAS OCCURRED THAT CANNOT BE ATTRIBUTED TO A BACKUP GENERATOR. STATUS MESSAGE 2448070 LATCHED AP MODE MESSAGE 2448070 LATCHED AP MODE. FOUND STATUS MESSAGE 'ELEC BACKUP SYS' DISPLAYED WITH CORRELATED MAINT MESSAGE 24480SDR UALA2012043002532Warning Message · multiple failRIGHT ENGINE HIGH PRESSURE FUEL SHUTOFF VALVE (HPSOV) OR RIGHT SPAR FUEL VALVE POSITION DISAGREES WITH COMMANDED POSITION. ADVISORY MESSAGE 01- ACTIVE ENGINE SHUTDOWN MODE DEPENDANT; FUEL METERING UNIT (FMU) (R ENG) FUEL SHUTOFF VALVE (SOV) IS NOT IN COMMANDEDSDR UALA2012041502286Switch · faultyPER CREW, RT ENGINE EICAS MESSAGE AFTER ENGINE SHUT-DOWN AND TOOK 30 SECONDS FOR ENGINE TO SHUT-OFF AFT R FUEL CUTOFF SWITCH WAS SELECTED TO THE OFF POSITION. PER EMC REPLACE RELAY K72204 (PCN 566-0640) & RELAY K76207 (PCN 566-0648) FOR MSG 73-60212, FUEL METSDR UALA2012040902155Control Panel · inoperativeWATER INDICATOR INOPERATIVE ON CSCP. WATER MUST BE SERVICED TO FULL. REPLACED CSCP, WATER INDICATION IS OKAY.SDR UALA2012033001990Warning Light · illuminatedRIGHT CENTER FUEL PUMP PRESSURE LIGHT ON WITH SWITCH DEPRESSED. CYCLED RIGHT CENTER CIRCUIT BREAKER, NO HELP.SDR UALA2012032301863Unknown · malfunctionedCREW REPORT: LEFT CENTER FUEL PUMP LOW PRESSURE, ALSO FUEL PUMP CENTER STAT MESSAGE. RESET ELMS 110 PANEL. ADDED FUEL TO CTR TANK & OPERATED PUMP, NO STATUS OR CMC FAULTS. INDICATIONS ON FUEL MANAGEMENT PAGE ALL NORMAL, SYSTEM OPS NORMAL.SDR UALA2012031201581Connector · wrong partCONNECTOR D5188P IS NOT THE CORRECT PART NUMBER. REF FCD NO. 3321-01022, TABLE 4, ZONE 3, ITEM 13. LOCATION STA 1580, STRINGER S-12R. REPLACED CONNECTOR REF FCD 3321-01022, OP CHECK GOOD.SDR UALA2012031201615Connector · wrong partCONNECTOR DM33036B IS NOT THE CORRECT PART NUMBER, REF FCD NUMBER 3321-01022, TABLE 4 ZONE 3 ITEM 23. LOCATION STA 1990 RBL 90. REPLACED CONNECTOR. OPS CHECK OK.SDR UALA2012031201614Connector · wrong partCONNECTOR DM33036A IS NOT THE CORRECT PART NUMBER, REF FCD NUMBER 3321-01022, TABLE 4 ZONE 3 ITEM 23. LOCATION STA 1990 RBL 90. REPLACED CONNECTOR. OPS CHECK OK.SDR UALA2012031201613Connector · wrong partCONNECTOR DM33036B IS NOT THE CORRECT PART NUMBER, REF FCD NUMBER 3321-01022 TABLE 4 ZONE 3 ITEM 12 LOCATION STA 1990 LBL 90. REPLACED CONNECTOR REF FCD 3321-01022, OPS CHECK GOOD.SDR UALA2012031201580Connector · improper partCONNECTOR D5188J IS NOT THE CORRECT PART NUMBER, REF FCD N. 3321-01022, TABLE 4, ZONE 3, ITEM 13. LOCATION STA 1580, STRINGER S-12R. REPLACED CONNECTOR PER FCD 3321-01022, OP CHECK GOOD.SDR UALA2012031201616Door · out of sequenceDOOR 2L WOULD NOT CLOSE PROPERLY. INSPECTED DOOR AND FRAME, NO DAMAGE. FOUND DOOR OUT OF SEQUENCE. OPERATED DOOR SEVERAL TIMES DOOR CLOSES AND ARMS NORMAL.SDR UALA2012031201577Door · out of sequenceDOOR 2L WOULD NOT CLOSE PROPERLY. INSPECTED DOOR AND FRAME, NO DAMAGE. FOUND DOOR OUT OF SEQUENCE. OPERATED DOOR SEVERAL TIMES DOOR CLOSES AND ARMS NORMAL.SDR UALA2012030201311Connector · crackedCEILING LIGHT ASSY CONNECTOR DM33085C IS CRACKED, LOCATED ABOVE SEAT ROW 23HJ, STA 1076. REPLACED CONNECTOR, CHECKS GOOD.SDR UALA2012030201301Connector · defectiveCEILING LIGHT ASSY L33146 ABOVE RT AFT LAV STA 1980, CONNECTOR IS NON COMPLIANT PER AMM. REPLACED CONNECTOR, CHECKS GOOD.
Back to N210UA