N214HA
Service difficulty reports · 75
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N214HA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N214HA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA2026082566633Door · bindingDOOR 1R HARD TO ARM. GROUNDED - YES. LUBRICATED DOOR 1R AND IS NOW FUCTIONING PROPERLY. NO DISCREPANCIES FOUND WITHIN DOOR AT THIS TIME. A/C OK FOR SERVICE.SDR ASAA2026082366492Warning Message · false activation(ECAM DID NOT RETURN) NOTICE TO MX ON T/O ,ENG 1 COMP, STALL ECAM CLRD AFTER 1 SEC , LOW SPEED ABORT. GROUNDED - YES. PERFORMED TSM 71-00-00-810-854-A PERFORMED VISUAL INSPECTION OF ENG INLET AND EXHAUST AREA, NO DAMGAE NOTED. AND PERFORMED STEP 3.A.(2)(A) ACFSDR ASAA2025121262321Epsu · inoperativeBAT/EPSU FW 11WL EXT L. GROUNDED - YES. REPLACED EMER 11WL EPSU PER AMM 33-51-38. OPS CHECK GOOD. OK FOR SERVICE.SDR HALA20250826263Gcu · no testDIV - ECAM: GEN 1 FAIL. EPGS SYSTEM TEST: GCU 1 TEST FAILED. FAULT MESSAGE IDG1(E1-400XU)SERVO VLV/GCU1 (1XU1). PERFORMED TSM 24-20-00-810-914-A. FOUND CABLE E1-400XU CONTAMINATED AND SLIGHTLY LOOSE. CLEANED AND SECURED AS REQUIRED. RESISTANCE & WIRE CHECKS ALSDR HALA20250826262Wire Harness · faultedETOPS - ENG 1 LOOP B FAULT. REPLACED ENG 1 LOOP B FIRE HARNESS PER A321 AMM 26-12-62 OPS CHECK GOOD , OK FOR SERVICESDR HALA20250818249Generator · faultedETOPS - ELEC GEN 1 FAULT- AT CRUISE DID NOT RESET. REMOVED & REPLACED #1 IDG PER AMM 24-21-51. OPS CHECK IS GOOD. OKAY TO CONTINUE.SDR HALA20250717039Smoke Detector · false activationSMOKE LAVATORY SMOKE MESSAGE CONFIRMED WITH FA FALSE ALERT. FFA DID RESET AND MESSAGE CLEARED. NO SMOKE/VAPE/FIRE PRESENTSDR HALA20250715212Wire Harness · faultedETOPS - ON CLIMB OUT MOMENTERY ECAM FOR ENG 1 LOOP B FAULT MESSAGE CLEAR ON ITS OWN AFTER A FEW MINUTES. REMOVED AND REPLACED ENGINE 1 HARNESS 4166KS PER AMM 26-12-62 AND REPLACED ENGINE 1 CORE AGB LOOP B FIN 4002WD2 PER AMM 26-12-17 OPS CHECK OKSDR HALA20250627199Exciter · faultedETOPS - ENG 1 IGN B FAULT. REMOVED & REPLACED IGNITION EXCITER PER AMM 74-11-01-000-801-A & AMM 74-11-01-400-801-A. REMOVED & REPLACED IGNITER PLUG PER AMM 74-21-01.PERFORMED OPS TEST OF IGNITION SYSTEM PER AMM 74-00-00-710-802-A. OPS TEST GOOD. NO FAULTS NOTESDR HALA20250609168Starter · faultedETOPS - APU AUTOSHUTDOWN 3 TIMES. REMOVED AND REPLACED STARTER ON APU PER AMM 49-42-51. REPLACED CLUTCH PER AMM 49-42-51. REPAIRED DAMAGED WIRE PER E105 -C30086-INI OPS CHECK GOOD OK TO CONTINUESDR HALA20250514133Igniter · faultedETOPS - ON START ENG 2, ENGINE REATTEMPT 2ND ATTEMPT SUCCESSFUL ENG 2 IGN A FAULT. REPLACED #2 ENG A IGNITER PLUG PER AMM 74-11-01. AUDIBLE CHECK GOOD. OK FOR SVC.SDR HALA20250514132Fire Loop · faultedETOPS - ENG 1 FIRE LOOP B FAULT CAME ON MULTIPLE TIMES DURING CRUISE AND WOULD EXTINGUISH. FOUND THERMAL DAMAGE ON CONTACTS OF 454VC1. REPLACED ALL 4 CONTACTS OF 454VC1 PER ESPM 20-48-24. FDU 1 OPS CHECK OK PER AMM 26-12-00. PERFORMED ENGINE RUN PER AMM 71-00-SDR HALA20250507127Fire Loop · false indicationETOPS - ENG 1 FIRE LOOP B FAULT 3X IN CRUISE. CLEARED ON ITS OWN. REMOVED & REPLACED ENG 1 FIRE LOOP B IAW AMM 26-12-17, OPS TEST OK. NO FAULT NOTED. OK FOR SVCSDR HALA20250506124Fire Loop · faultedETOPS - SPURIOUS ENG1 FIRE LOOP B ECAM. ECAM ILLUMINATED 4 TIMES DURING FLIGHT. REMOVED AND REPLACED ENG1 AGB LOOP B PER AMM 26-12-17, PERFORMED FDU BITE TEST PER AMM 26-12-00 TEST OK. A/C OK FOR SVC.SDR HALA20250505025Radome · damagedFOUND BIRD STRIKE ON RADOME DAMGE BEYOND LIMITS. REMOVED AND REPLACED RADOME IAW AMM 53-15-11. OPS CHECK GOOD . OK TO CONTINUESDR HALA20250414105Fire Loop · faultedETOPS-ECAM - ENG 1 FIRELOOP B FAULT. REMOVED AND REPLACED ENG 1 FIRE LOOP B HARNESS (4166KS). PER AMM 26-12-62-400-802-A. FIRELOOP TESTS OK. OK FOR SVC.SDR HALA20250409104Igniter · damagedETOPS - DURING ENG 1 BORESCOPE INSP OF THE COMBUSTION CHAMBER AND HPT NOZZLE GUIDE VANES, IGNITER PLUG WAS REMOVED AND FOUND DAMAGED. REPLACED IGNITER REF AMM 74-21-01. CHECKS OKSDR HALA20250331092Fire Loop · faultedETOPS - BTB FOR AN ENG 1 FIRE LOOP FAULT CLEARED AFTER 10 MINUTES . REMOVED AND REPLACED ENGINE 1 AGB LOOP B PER A321 AMM 26-12-17-000-802-A AND 26-12-17-400-802A. FDU BITE CHECK PASS PERFORMED ENGINE RUN ON EGNINE #1 NO FAULTS AC OK TO CONTINUESDR HALA20250324084Wire Harness · looseETOPS - ENG 1 FIRE LOOP B FAULT APPEARED SEVERAL TIMES DURING FLIGHT. CLEARED AFTER 30-60 SEC. GROUND CHECK HARNESS 4166KA FOUND LOSE AND DAMAGED CLAMP NEAR 4001WD2 REMOVED AND REPLACED CLAMP CHECKED OK. OPS TEST FDU #1 TEST OK PER: AMM 26-12-00. CHECKED 454VCSDR HALA20250314080Wire Harness · faultedETOPS - ENG 1 FIRE LOOP A ECAM FOR ABOUT 1 MINUTE ON CLIMB OUT. GROUND CHECK 452VCA PIN 1 TO PIN 2 FOR 4002WD1 AND 452VCA PIN 3 TO PIN 4 FOR 4001WD1 INSULATION AND RESISTANCE CHECK OK. REMOVED AND REPLACED HARNESS 4165KS ON ENG #1 PER AMM 26-12-61. OPS CHECK OSDR HALA20250220065Packing · failedATB - GREEN HYD RES LOW LEVEL ECAM REACHING 32,000'. THEN GREEN LOW HYD LO PRES ECAM. AIR TURN BACK TO HNL. FOUND BROKEN PACKING AT #1 ENG PUMP PRESSURE SWITCH. INSTALLED NEW PACKING PER AMM 29-13-17/802-A. OPS CHECK GOOD. NO LEAKS NOTED. A/C OK FOR SVC.SDR HALA20250127037Hydraulic Line · leakingETOPS - FOUND #2 ENG PYLON HYDRAULIC PRESSURE LINE LEAKING DURING WALKAROUND. REPLACED #2 ENG HYDRAULIC PYLON PRESSURE LINE REF AMM 29-13-49. ALL OPS AND LEAK CHECKS GOOD. OK TO CONTINUE SERVICE.SDR HALA20250124032Hydraulic Line · leakingETOPS - FOUND #2 ENG PYLON HYDRAULIC PRESSURE LINE LEAKING DURING WALK AROUND. REPLACED #2 ENG HYDRAULIC PYLON PRESSURE LINE REF AMM 29-13-49. ALL OPS AND LEAK CHECKS GOOD. OK TO CONTINUE SERVICE.SDR HALA20241226377Fire Loop · faultedETOPS - ENG 1 FIRE LOOP B FAULT. REMOVED AND REPLACED ENG 1 LOOP B HARNESS ASSLY (4166KS) PER AMM 26-12-62 BITE TEST GOOD. PERFORMED ENGINE RUN AS PRECAUTION NO FAULTS NOTED.SDR HALA20241216365Fire Loop · faultedETOPS - ENG 1 FIRE LOOP B FAULT 2X IN CRUISE & 1X ON DESCENT CLEARED BOTH TIMES AFTER 30 MIN. REPLACED FDU 1 REF AMM 26-12-34. OPERATIONAL CHECKS GOOD. RAN ENGINE AS PRECAUTIONARY AND NO DEFECTS OR FAULTS. OK TO CONTINUE SERVICE.SDR HALA20241202346Fuel Cap · missingETOPS - FUELER REPORT FUEL CAP DIFFICULT TO REMOVE. FOUND CAP DEFORMED. REMOVED AND REPLACED FUEL CAP.SDR HALA20241127338Fire Loop · false activationETOPS - ENG 1 LOOP CAUTION. REPEATEDLY (7 TIMES) DURING FLIGHT. GROUND REMOVED AND REPLACED HARNESS FIRE ASSEMBLY (4165KS) TEST OK PER AMM 26-12-61-400-802A. (RQ 19537 NOV/26/2024. PERFORMED #1ENG RUN. NO FAULTS NOTED. OK FOR SVC.SDR HALA20241125333Fire Loop · intermittentETOPS - ENG 1 FIRE LOOP A FAULT INTERMITTENT THROUGHOUT FLIGHT OCCURED 4 TIMES (IN CLIMB , CRUISE, AND DESCENT). PERFORMED TSM 26-12-00-810-852-A BITE MESSAGE FOR "CHECK ENG 1 AGB LOOP A" REMOVED AND REPLACED ENG 1 COER AGB LOOP A PER AMM 26-12-17-00-802 & 26-SDR HALA20241022292Terminal · crackedETOPS - WHILE TROUBLESHOOTING ENG 1 LPA FIRE LOOP FOUND 4181KS TERMINAL CRACKED AND 4165KS INTERMITTENT SHIRT TO GND. REPLACED ENG 1 4181KS PER AMM 26-12-61. REPLACED ENG 1 HARNESS 4165KS PER AMM 26-12-61-400-802. OPERATIONAL CHECK OK PER AMM 26-12-00710-001-SDR HALA20241017290Fire Loop · false indicationETOPS - INFO TO MX: ENG1 FIRELOOP A FAULT DURING CLB. ECAM CLEARED. BITE FDU1 NO FAULTS. CHECK FDU1 J-K 1.493 OHMS, J TO GND OPEN, K TO GND OPEN PER ASM 26-12-01. REPLACED FDU1 PER AMM 26-12-34 OPS CHECK OK.SDR HALA20240820235Bypass Valve · malfunctionedATB - DUE TO ETOPS VERIICATION FLIGHT UNSATISFACTORY PLUS ISSUES WITH MULTIPLE ECAMS. PFR FAULT AIR PACK 2 REGUL FAULT ATA 21-61 CARRIED OUT TROUBLESHOOTING OF AIR PACK 2 IAW TSM 21-61-00-810-817-A. CARRIED OUT OPERATIONAL TEST OF PACK TEMP-CONTROL SYS IAW A32SDR HALA20240705179Warning Light · illuminatedAFTER APU START ON ARRIVAL "LOW OIL LEVEL" FLASHING (2ND WRITE-UP IN 2 DAYS). REMOVED AND REPLACED APU ASSY PER AMM 49-11-11. OPS CHK AND LEAK CHK GOOD.SDR HALA20240528147Interphone · malfunctionedETOPS - AFT GALLEY INTERPHONE VOLUME TOO LOW. REMOVED AND REPLACED INTERPHONE IN REF TO AMM 23-73-44 OPS CHECK GOOD OK TO CONTINUE.SDR HALA20240520024Slide · dislodged1L DOOR SLIDE FELL OFF DOOR. REMOVED AND REPLACED 1L SLIDE ASSY PER AMM 25-62-44. OPS CHECK GOOD. OK FOR SVC.SDR HALA20240508127Generator · faultedETOPS - APU GEN FAULT. REMOVED AND REPLACED GAPCU, CONDITION SAME, REPLACED ORIGINAL GAPCU PER AMM 24-41-34 AND TSM 24-23-00-810-813-A. REMOVED AND REPLACED APU GENERATOR PER AMM 24-23-51, OPS AND LEAK CHECK GOOD, APU OIL LVL GOOD. OK FOR SVC.SDR HALA20240112012Unknown · unknownETOPS - ENG 1 FIRE LOOP A ECAM FAULT. REMOVED & REPLACED ENG 1 FIRE LOOP A HARNESS (4165KS) PER AMM 26-12-61. FAULT CLEARED FDU 1 TEST OK.SDR HALA20231218276Unknown · unknownETOPS - ECAM: ENG 1 FIRE LOOP A FAULT. FOUND AGB LOOP A CLAMP BROKEN, REPAIRED PER M105 FILE # R0363. PERFORMED OPS TEST OF FDU 1 PER AMM 26-12-00. OPS TEST GOOD. OK FOR SERVICESDR HALA20231211270Unknown · unknownETOPS - INFO TO MAINT: ECAM ENG 1 FUEL FILTER PARTLY CLOGGED DURING INITIAL CLIMB OUT. EXTINGUISHED AFTER ABOUT 3 MIN. NOTED BY MX. REMOVED AND REPLACED THE #1 ENG FUEL FILTER ELEMENT AND FUEL FILTER DIFFERENTIAL PRESSURE SENSOR PER AMM 73-11-06 / 73-34-21. OPSDR HALA20231010220Unknown · unknownETOPS - ECAM APU AUTO SHUTDOWN OCCURED WHILE TAXINING TO GATE. WE ATTEMPTED 3 START ATTEMPTS PER MOC. REMOVED APU STARTER PER AMM 49-42-51. REMOVED AND REPLACED STARTER MOTOR CLUTCH PER AMM 49-42-52. REPLACED APU STARTER PER AMM 49-42-51. OPS CHECK GOOD. OK FOSDR HALA20231003215Unknown · unknownETOPS - DURING ENG ONE START CABIN AND COCKPIT FILLED W/ SMOKE. SHUT OFF PACK 1 AND SMOKE DISSIPATED. REMOVED & REPLACED FRONT PACKING ON INLET CONE PER AMM 72-15-00-960-801. REPLACED #1 ENG REF WO 267827 T/C 5321-72-HW1-02.SDR HALA20230908195Stator Vane · faultyETOPS - ENG 1 COMPRESSOR VANE FAULT ON ECAM. REMOVED AND REPLACED ENG 1 HPC STATOR VANE PRIMARY ACTUATOR PER AMM 75*31-02. OPS CHECK GOOD. OK TO CONTINUE SERVICE.SDR HALA2023082300176Rod · damagedETOPS - DURING #1 ENGINE CHANGE FOUND ROD DAMAGED. REMOVED AND REPLACED #1 ENGINE ROD PER IPC 29-11-86-03A,OK TO CONTINUE SERVICE.SDR HALA2023072100154Unknown · unknownOTHER - DIRTY SOCK SMELL DESCENDING THROUGH 4000' FT. PERFORMED ENG #1 AND #2 RUN, ISOLATED 1 AND 2 PACKS, APU BLEED NOTED NO SMELL TSM 71-00-00-810-847-A.SDR HALA2023031300040Transducer · damagedETOPS - PASSING 10,000 FT ENG 2 FADEC SYS FAULT ECAM. PERFORMED TSM 77-11-00-710-059-A. FOUND CONNECTOR P64 ON N2 SPEED TRANSDUCER LOOSE AND TRANSDUCER PINS DAMAGED. REMOVED AND INSTALLED TRANSDUCER IAW AMM 77-11-23. OPS CHECK GOOD NO FAULTS NOTED OK TO CONTINSDR HALA2022121900311Alternator · faultedETOPS-ENG 2 FADEC SYS FAULT DURING APPROACH. PERFORMED GROUND SCAN OF EEC CH1A AND CH2B GOT "PMA SIG FAIL", FOUND CANNON PLUG TO ENG 2 PMA NOT CONNECTED PROPERLY AND PIN AND SOCKET DAMAGED. REMOVED AND REPLACED W03 HARNESS PER AMM 73-21-63, OPS CHECK GOOD OK TSDR HALA2022121300309Sensor · faultedECAM IN AIR "ENG 2 FADEC SYS FAULT" PER FPR ENG 2B-0452-N2 SPEED SENSOR FAIL. PERFORMED T/S IAWTSM 77-11-00-810-812-A. DURING FAULT CONFIRM IAW CHART NO ASSOCIATED MESSAGES. DURING ENG START UP ECAM WARNING AF ABORTED START DUE TO BOWED MOTOR OVERSPEED. PERSDR HALA2022111000292Outflow Valve · crackedREMOVED AND REPLACED AIR INLET SKIN CHECK VALVE PER AMM 21-26-56. REPLACED DUCTS DUE TO CRACKS P/N D2122891000001 & D212289090001 AND SILENCER P/N D2122953400001 PER 21-26-81. OPS AND LEAK CHECKS GOOD.SDR HALA2022110700286Outflow Valve · faultedATB-AFTER T/O SKIN AIR INLET VALVE ECAM. THROUGH 4000' FEET IN CLIMB LOUD EXPLOSION SOUND, VIBRATION, AND PRESSURE FLUCTUATIONS. TROUBLESHOOTING PER TSM AND
BORESCOPE INSPECTION ARE IN-PROGRESSSDR HALA2022050900099Valve · inoperativeATB ETOPS - ACFT RETURNING TO OAK, CREW REPORTED ECAM, SKIN AIR OUTLET VLV MSG LIMITING ACFT TO FL10. PERFORMED AEVC TEST PER AMM 21-26-00-710-001-A. FOUND OUTER SKIN VALVE IN AMBER XXX. PUT THE OUTER SKIN OUTLET VALVE IN 45 DEGREES FOR DMI# 205115. REPLACED SSDR HALA2022032300081None · noneETOPS - R TK PUMP 2 LO PR // REMOVED AND REPLACED PRESSURE SWITCH FIN #28QA WITH NO HELP AMM 28-21-00 PB400CONF00. NT 3263701 REMOVED AND REPLACED RIGHT TANK PUMP 2 PER AMM 28-21-51. OPS CHECK GOOD. NO LEAKS DETECTED. OK FOR SERVICE.