N217UA
Service difficulty reports · 149
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N217UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N217UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2026081418634Battery Pack · no testEMERGENCY LIGHTS OPERATIONAL TEST, WITH THE TEST SWITCHES PROCEDURE. PACK BATTERY EMERGENCY POWER M33407, M33408 AND M33409 INOP. EMERGENCY POWER BATTERY PACKS M33407, M33408 AND M33409 REPLACED IAW AMM 33-51-06-960-802.SDR CALA2026052516494Battery Pack · faultedEMERGENCY POWER ASSIST SYSTEM (EPAS) BATTERY, ELECTRICAL CHARGE CHECK (PED 1, 2, 3, 4) PROCEDURE - FOUND EPAS STATUS LIGHT NOT BLINKING IN ARMED POSITION AT DOOR 2 RIGHT EMERGENCY POWER ASSIST SYSTEM (EPAS) BATTERY PACK AT DOOR RIGHT 02 WAS REPLACED AND CHECKSDR CALA2026050415944Unknown · odorHOT PLASTIC ODOR BY DOOR 3L ON TO..NO SMELL DETECTED IN FLIGHT IMAGES ADDED. DEBRIEFED FLIGHT CREW, CABIN CREW STATED SAME BURN PLASTIC SMELL HAPPEN ON THIS ACFT 2 DAYS PRIOR INTO (FCO ROME) INSPECTED AREA AT 3L AND 3R, OPS PACKS NO ODOR OR SMOKE NOTED, INSPECSDR CALA2026020213479Battery · dischargedL4 DOOR M33407 BATTERY PACK FOUND INOP. L4 DOOR M33407 BATTERY PACK FOUND INOP. REPLACED BATTERY AND TEST NORMAL. REPLACED L4 DOOR EMERGENCY LIGHT POWER SUPPLY M33407 BATTERY PACK AND PERFORMED NEW BATTERY INSTALLATION TEST, THE TEST RESULT FOUND NORMAL AS PSDR CALA2026020213478Battery · dischargedR1 DOOR EMERGENCY LIGHT POWER SUPPLY M33094 BATTERY PACK FOUND LOW CAPACITY REF HAECO NON-ROUTINE NO.94995751. R1 DOOR EMERGENCY LIGHT POWER SUPPLY M33094 BATTERY PACK FOUND LOW CAPACITY. REPLACED THE BATTERY AND TEST NORMAL.SDR CALA2025111311169Battery Pack · dischargedSOME PROXIMITY AND AREA EMERGENCY LIGHTS DONT COME ON. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY PACKS M33401; M33096 AND M33098 REF AMM33-51-00.SDR CALA2025060405270Engine · making metalCREW REPORTS - #1 ENG FAILED CREW REPORTS- #1 ENG FAILED 400FT AGL 10 SEC AFTER ROTATION, EGT SPIKED (RED LINED) TO 785, SHOWED 605 AFTER ENGINE SHUTDOWN. A/ C YAWED TO THE LEFT, CREW LEVELED A/C AT 1500 FT. SAW ENGINE HAD FAILED AND FA SAID THEY HEARD A LOUD SDR CALA2025021902369Sleeve · damagedPDA 1 DURING ETOPS PDSC IN DUB, DAMAGE TO LH ENGINE OUTBOARD T/R SLEEVE OBSERVED. MISSING MATERIAL ON TRAILING EDGE OF SLEEVE FROM 8 O?CLOCK TO 9 O?CLOCK OBSERVED DIMENSIONS ARE 27.5 INCHES TOP TO BOTTOM AND 15.5 INCHES FROM TRAILING EDGE TO END OF DAMAGED ARSDR CALA2024123003190Battery · inoperativeCAB - R2 DOOR EPAS SWITCH FND NO GREEN LIGHT WHEN ARMED TRANSFER REF NON - ROUTINE WO.4241858. DOOR R2 EPAS BATT PACK REPLACED AND INSTALLATION TEST C/O NORMAL IAW AMM52-11-20.SDR CALA2024112901354Lock · malfunctionedDOOR FLIGHT LOCK 2L EICAS STATUS #2 LEFT PASSENGER ENTRY DOOR FLIGHT LOCK COMMAND/FLT LK RLY/SENS OR DISAGREEMENT. DB PSEU 2 (L2) DB PSEU 2 (R2) FOUND NO ACTIVE FAULT,OPS CKD OK REF AMM52-11-26-740-801. FOUND MESSAGE 52-11300 AND 52-12090 IN PRESENT LEGSDR CALA2024070900174Bulb · burned outELECTRICAL ODOR ON DESCENT, CAPT ADVISE 5 MINS PRIOR LANDING, PURSOR REPORTED ELECTRICAL ODOR BY GALLEY 2. CHECKED LAMPS, OVENS, OUTLETS, WORKLIGHTS, TRASH RECEPTACLES, LAV LIGHTS AND FLUSH MOTOR FOR OPERATION PERTAINING TO ELECTRICAL ODOR. FOUND 2 GALLSDR CALA2023122203721Steering Sys · warning messageTO CONFIG WANING ON TO MAIN GEAR STEERING MAIN GEAR STEERING EIC AS PERFORMED FIM TASK 32-52-TASK 805. MXG 32-63010. STEP E. STATUS MESSAGE CLEARED. CREW CONFIRMS SPEED BELOW 20KNTS AND RTO NEVER ENGAGED. PERFORMED FIM 32-52 TASK 805 FOR MSG 32-63010. MSG CLEASDR CALA2023070502163Skin · unknownR2 DOOR EXT LOWER SKIN FOUND REINFORCING REPAIR AND CANNOT FOUND THE RECORD REF HX NR WO. 1834573, ORIG BY V896920 CABIN R2 DOOR EXTERNAL SURFACE LOWER SKIN AT MIDDLE AREA REPAIRE D AS PER SRM 52-10-01-2R-8 REPAIR 8 FIG 202, FORM 44-0008 ITEM 1 -28 ACCOMPLISHESDR CALA2023062602019Battery Pack · no testEMERGENCY LIGHTING BATTERY PACK (M33099) AT DR 2L AFT FOUND CAPA CITY FUNCTIONAL CHECK FAIL REF HX NR WO.1826276, ORIG BY V920586 REPLACED EMERGENCY LIGHTING BATTERY PACK (M33099) AT DR 2L AFT AND INSTALLATION TEST CARRIED OUT AS PER AMM 33-51-06. TEST NORM ALSDR CALA2023062602018Battery Pack · no testEMERGENCY LIGHTING BATTERY PACK (M33097) AT DR 2R FWD FOUND CAPA CITY FUNCTIONAL CHECK FAIL REF HX NR WO.1826265, ORIG BY V920586 REPLACED EMERGENCY LIGHTING BATTERY PACK (M33097) AT DR 2R FWD AND INSTALLATION TEST CARRIED OUT AS PER AMM 33-51-06. TEST NORM ALSDR CALA2023062602017Battery Pack · no testEMERGENCY LIGHTING BATTERY PACK (M33098) AT DR 2R AFT FOUND CAPA CITY FUNCTIONAL CHECK FAIL REF HX NR WO.1826251, ORIG BY V920586 REPLACED EMERGENCY LIGHTING BATTERY PACK (M33098) AT DR 2R AFT AND INSTALLATION TEST CARRIED OUT AS PER AMM 33-51-06. TEST NORM ALSDR CALA2023062602025Battery Pack · no testEMERGENCY LIGHTING BATTERY PACK (M33406) AT DR 3L MID FOUND CAPA CITY FUNCTIONAL CHECK FAIL REF HX NR WO.1826328, ORIG BY V920586 REPLACED EMERGENCY LIGHTING BATTERY PACK (M33406) AT DR 3L MID AND TESTED NORMAL AS PER AMM 33-51-06 ACCOMPLISHED BY MECH V927704,SDR CALA2023062602024Battery Pack · no testEMERGENCY LIGHTING BATTERY PACK (M33424) AT DR 1L AFT FOUND CAPA CITY FUNCTIONAL CHECK FAIL REF HX NR WO.1826313, ORIG BY V920586 REPLACED EMERGENCY LIGHTING BATTERY PACK (M33424) AT DR 1L AFT AND TESTED NORMAL AS PER AMM 33-51-06 ACCOMPLISHED BY MECH V927704,SDR CALA2023062602023Battery Pack · no testEMERGENCY LIGHTING BATTERY PACK (M33409) AT DR 4R AFT FOUND CAPA CITY FUNCTIONAL CHECK FAIL REF HX NR WO.1826305, ORIG BY V920586 REPLACED EMERGENCY LIGHTING BATTERY PACK (M33409) AT DR 4R AFT AND TESTED NORMAL AS PER AMM 33-51-06 ACCOMPLISHED BY MECH V927704,SDR CALA2023062602022Battery Pack · no testEMERGENCY LIGHTING BATTERY PACK (M33405) AT DR 3L AFT FOUND CAPA CITY FUNCTIONAL CHECK FAIL REF HX NR WO.1826300, ORIG BY V920586 REPLACED EMERGENCY LIGHTING BATTERY PACK (M33405) AT DR 3L AFT AND INSTALLATION TEST CARRIED OUT AS PER AMM 33-51-06. TEST NORM ALSDR CALA2023062602021Battery Pack · no testEMERGENCY LIGHTING BATTERY PACK (M33400) AT DR 3L FWD FOUND CAP ACITY FUNCTIONAL CHECK FAIL REF HX NR WO.1826291, ORIG BY V920586 REPLACED EMERGENCY LIGHTING BATTERY PACK (M33400) AT DR 3L FWD AND INSTALLATION TEST CARRIED OUT AS PER AMM 33-51-06. TEST NORM ALSDR CALA2023062602020Battery Pack · no testEMERGENCY LIGHTING BATTERY PACK (M33096) AT DR 2L FWD FOUND CAPA CITY FUNCTIONAL CHECK FAIL REF HX NR WO.1826288, ORIG BY V920586 REPLACED EMERGENCY LIGHTING BATTERY PACK (M33096) AT DR 2L FWD AND INSTALLATION TEST CARRIED OUT AS PER AMM 33-51-06. TEST NORM ALSDR CALA2023040301009Sensor · unknownAPU SHUTDOWN EICAS ADVISORY APU AUTO-SHUTDOWN HAS OCCURRED. APU SURGE BLEED SYSTEM SENSORS FOUND COMPLETELY CLOGGED. THE CIFFERELLO ADDITIONAL MESH FILTER SCREEN LOCATED AT THE INLET PRESSURE CLEARED BLOCKAGES FROM PNEUMATIC LINES AND CLEANED THE INTAKE 40-11-SDR CALA2023020600340Door · not reportedDOOR FWD CARGO EICAS CAUTION FORWARD CARGO DOOR NOT FULLY CLOSED, LATCHED AND LOCKED. REMOVED AND REPLACED FWD CARGO DOOR WIRE BUNDLE, OPPERATED CARGO DOOR, OPS CK GOOD. CARGO DOOR INDICATES CLOSED IN FLIGHT DECK WHEN DOOR IS CLOSED.SDR CALA2023020600343Battery · not reportedEMERGENCY LIGHTS OPERATIONAL CHECK {B777-33-3-7030} - 2L EXTERIOR EMERGENCY LIGHT INOP SUSPECT ONE BATTERY PACK NEEDS REPLACED ABOVE DOOR 2L OVERHEAD WHEN RELAMED BULB TRY TO COME ON. SWAPPED BATTS AT M33096 AND PANEL M33099 LIGHT OPS CK''D NORMAL. REMOVED ASDR CALA2023011100089Door Seal · noisyDOOR 1R SEAL NOISY CLEANED DOOR SEAL 1 RIGHT, PRESSURIZED AIRCRAFT NO NOISE NOTED NO LEAKS FOUND.SDR CALA2022061501508Battery Pack · dischargedM/D LLAR EMER LT POWER PACK 1EA FOUND LOW CAPACITY REFER HAECO N ON-ROUTINE NO.9490383,ORIGINATED EMP BY V905377,SPEC NO.B777-33- 3-7025. PERFORMED BY EMP:V905377,REPLACED LLAR EMER LT BATTERY PACK AND CARRIED OUT INSTALLATION TEST FOUND NORMAL AS PER AMM 33-5SDR CALA2022060601441Skin · puncturedRIGHT ELEVATOR HAS ONE PUNCTURE DUE TO HAIL, 27 INCHES FROM INBOARD EDGE, 31 1/2 INCHES FROM TRAILING EDGE, 1 INCH DIAMETER COVERED UP REF SRM 55-20-01-1A-1, NO DELAMINATION NOTED OUTSIDE DAMAGE AREA, PROTECTED PUNCTURE WITH SPEED TAPE. LOCKED FOR MAINTENANCE SDR CALA2022060601440Skin · delaminatedLEFT SIDE ELEVATOR OUTBOARD UPPER SURFACE 1EA DELAMINATION REF HAECO NON-ROUTINE NO:9488657 - ORIGINATED BY EMP V902926, SUPPORT TASK. PERFORME BY EMP V902926,LEFT SIDE ELEVATOR OUTBOARD UPPER SURFAC E 1EA DELAMINATION REPAIRED AS PER SRM 55-20-01-2R-1 REPAIR SDR CALA2022060201428Skin · delaminatedLEFT SIDE ELEVATOR OUTBOARD UPPER SURFACE 1EA DELAMINATION REF HAECO NON-ROUTINE NO:9488657 - ORIGINATED BY EMP V902926, SUPPORT TASK. PERFORME BY EMP V902926,LEFT SIDE ELEVATOR OUTBOARD UPPER SURFAC E 1EA DELAMINATION REPAIRED AS PER SRM 55-20-01-2R-1 REPAIR SDR CALA2020021200407Warning Message · illuminatedELEC GEN OFF L EICAS ADVISORY LEFT GENERATOR CONTROL BREAKER (GCB) OPEN OR GENERATOR CONTROL S WITCH OFF AND ENGINE NOT SHUT DOWN. FIM TASK REF : FIM TASK REFERENCE NOT FOUND CMC MSG# 2431661 FLIGHT STATUS: L INTERMITTENCE CODE: M PH: CLIMB NARRATIVE: GENERSDR CALA2019020100195Power Supply · inoperativeREF NR L/P:9473253 - SPEC NO.B777-33-3-6019 - EMERGENCY LT POWER SUPPLY M023 FND NO DC OUTPUT. REPLACED EMERGENCY LT POWER SUPPLY CHARGE ASSY AND OP TEST CARRI ED OUT FND NORMAL AS PER AMM 33-51-06-960-803 REV85. ADD EMP:V903172 IDT BY TA551.SDR CALA2019020100194Power Supply · inoperativeREF NR L/P 9473252 - SPEC NO.B777-33-3-6019 - EMERGENCY LT POWER SUPPLY M33098 FND NO DC OUTPUT. REPLACED EMERGENCY LT POWER SUPPLY CHARGE ASSY AND OP TEST CARRI ED OUT, FOUND NORMAL AS PER AMM 33-51-06-960-813 REV.85. ADD EMP:V903172 IDT BY TA551.SDR CALA2019012800179Battery Pack · inoperativeDOOR NR 3 RT FWD EMERGENCY LT BATTERY PACK M33404 FND INOP. REPLACED DOOR NR 3 RT FWD EMERGENCY LT BATTERY PACK (M33404) AS PER AMM 33-51-06-960-802 REV 85. THEN C/O BATTERY PACK INSTALLATION TEST AS PER AMM 33-51-06-960-802 REV 85. THE RESULT FND NORMAL.SDR CALA2019012800177Battery Pack · inoperativeDOOR NR 3 LT FWD EMERGENCY LT BATTERY PACK M33400 FND INOP. REPLACED DOOR NR 3 LT FWD EMERGENCY LT BATTERY PACK (M33400) AS PER AMM 33-51-06-960-802 REV 85. THEN C/O BATTERY PACK INSTALLATION TEST AS PER AMM 33-51-06-960-802 REV 85. THE RESULT FND NORMAL.SDR CALA2019012800189Battery Pack · inoperativeDOOR NR 3 RT AFT EMERGENCY LT BATTERY PACK M33401 FND INOP. REPLACED DOOR NR 3 RT AFT EMERGENCY LT BATTERY PACK (M33401) AS PER AMM 33-51-06-960-802 REV 85. THEN C/O BATTERY PACK INSTALLATION TEST AS PER AMM 33-51-06-960-802 REV 85. THE RESULT FND NORMAL.SDR CALA2019012800183Battery Pack · dischargedREF NR L/P 9473233 - SPEC NO. B777-33-3-6019 - DOOR NR 2 RT AFT EM ERGENCY LT BATTERY PACK M33098 FND INOP. REPLACED DOOR NR 2 RT AFT EMERGENCY LT BATTERY PACK M33098 AS PER AMM 33-51-06-960-802 REV.85, THEN C/O BATTERY PACK INSTALLATION TEST AS PER AMM 33-51-SDR CALA2019012800182Light · crackedREF NR L/P 9471565 - EA 2500-05422C OP57-LAVATORY FLOOR PROXIMIT Y LIGHT ASSY CRACKED(P/N:S479W230-3)(6EA). REPLACED 6EA LAVATORY FLOOR PROXIMITY LIGHT ASSY AS PER AMM 33-5 1-05-960-802 REV.85. THEN C/O THE LAV FLOOR PROXIMITYY LIGHT ASSY INSTALLATION TEST AS SDR CALA2017042801155Skin · chafedRT FUSELAGE SKIN FROM 2108 - 2186 STR 2-3R FOUND CHAFING. SKIN REPAIRED AS PER ECRA 5330-06018 AND ECRA 5330-06019, INSPECTION REQUIREMENT AS PER ECRA 5330-06018 PART II NOTED.SDR CALA2017042801154Skin · chafedLT BS 2108 TO 2186 STR2-3 FUSELAGE SKIN FND CHAFING. SKIN REPAIRED AS PER ECRA 5330-06018 AND ECRA 5330-06019 INSPECTION REQUIREMENT AS PER ECRA 5330-06018 PART II NOTED.SDR CALA2017042201107Battery · dischargedFOUND CABIN LLAR EMERGENCY LT BATTERY INOP. REPLACED THE LLAR EMERGENCY LIGHT BATTERY AND C/O LIGHT TEST FOR REPLACEMENT. THE RESULT FOUND SATISFACTORY REF TO AMM 33-51-06-9 60-802 REV 79.SDR CALA2017042101088Battery · dischargedTEST FOUND L33531 AND L33552 EMERGENCY LT INOP. REPLACED LOW CAPACITY BATTERY M33097 AND M33406 AND TEST FOUND NORMAL REF SSM 33-51-13, SSM33-51-14 REV 69 AND AMM 33-51-06-960 -802 REV 79.SDR CALA2017042101087Battery Pack · dischargedDURING EMERGENCY BATTERY PACK CAPACITY CHECK, FOUND BATTERY PACK AT DOOR 1R (M33094) AND DOOR 4L (M33407) LOWER CAPACITY. REPLACED M33094 AND M33407 BATTERY PACK AND TEST OF NEW BATTERY PACK FOUND NORMAL REF AMM 33-51-06-960-802 REV 79.SDR CALA2016090600629Cover · missingEMERGENCY LIGHT IN RT AFT GALLEY. COVER MISSING AND WIRES EXPOSED. SECURED LIGHT ASSY.SDR CALA2016022495134Oven · contaminatedBUS CLASS GALLEY OVEN 31 SMOKING, CABIN & VENT NOT CLEARING AIR. INADEQUATE STOWAGE OF FOOD IN THE TOP SHELF, FOOD TRAYS STOWED WITHOUT LID. LED TO CONTAMINATION WITH CINNABON ON THE GRILL THAT PROTECTS THE FAN & HEATER ELEMENT. TOP OF THE OVEN CLEANED AS PSDR CALA2014100792369Idg · malfunctionedELECTRIC GEN DRIVER RT IDG FAULT, LOW INTERNAL OIL PRESS. REPLACED RT IDG IAW MM 24-11-01. ENG RUN PERFORMED & ALL OPERATIONS NORMAL.SDR CALA2014090992099Skin · deformedFORWARD CARGO DOOR LOWER AFT CORNER SKIN IS DEFORMED. MAJOR REPAIR. DAMAGE WAS REMOVED & DOUBLE REPAIR INSTALLED IAW SRM 52-30-01. VERIFIED CRACK FREE VIA NDT51-00-01 PT 6 HFEC. THIS IS A CAT A REPAIR.SDR CALA2014022790498Engine · surgesENG 222027 HAD A SILENT SURGE IN CRUISE.SDR CALA2013111292832B-Nut · not seatedEVIDENCE OF HYD LEAK IN THE AREA OF THE RT WING FLAPERON. RESEATED B NUT ON HYD FUSE FOR RT WING FLAPERON OTBD ACTUATOR, PRESSURIZED HYDS & OPERATED FLT CONTROLS, NO LEAKS NOTEDSDR CALA2013100391716Lens · brokenCM2000 FOUND EMERGENCY LIGHT LENS BROKEN AT AFT GALLEY. REPLACED WITH NEW EMERGENCY LIGHT ASSEMBLY & EMERGENCY LIGHT CHECKED ALL OK.
Back to N217UA