N341NB
Service difficulty reports · 213
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N341NB' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N341NB' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2019050903009Pump · malfunctionedSHIP 3141 - ATO - AT 40KTS DUE TO ECAM MESSAGE GREEN ENGINE HYD PUMP LOW PRESSURE. CORRECTIVE ACTION: MAINTENANCE REPLACED THE ENGINE DRIVEN PUMP AND PRESSURE SWITCH, TOPPED OFF THE GREEN HYD SYSTEM AND BLED. PERFORMED HIGH POWER RUN WITH ALL FLIGHT CONTROLS CSDR DALA2019042702676Lens · unsecureEMERGENCY SEAT MOUNTED LIGHTING DAMAGED / INOP / LOCATIONS: 2C / ACARS TEXT: FRC3352021C *2C *3C. RE-SECURED SEAT MOUNTED EMERGENCY LIGHT LENS'.SDR DALA2019042702675Lens · unsecureEMERGENCY SEAT MOUNTED LIGHTING DAMAGED / INOP / LOCATIONS: 1C / ACARS TEXT: FRC3352021C *2C *3C. SEE LP 1046743 FOR CORRECTIVE ACTION. RE-SECURED SEAT MOUNTED EMERGENCY LIGHT LENS'. OK FOR SVC.SDR DALA2019042702674Light · unsecureEMERGENCY SEAT MOUNTED LIGHTING DAMAGED / INOP / LOCATIONS: 3C / ACARS TEXT: FRC3352021C *2C *3C. REF LP 1046743 FOR CORRECTIVE ACTION. RE-SECURED SEAT MOUNTED EMERGENCY LIGHT LENS'. OK FOR SVC.SDR DALA2016121209872Box Beam · crackedFOUND CRACK BOXBEAM. REPAIRED PER AMDS CARD 5310-01450-02 IN ACCORDANCE WITH SB A320-53-1251 REV 1.SDR DALA2016110108094Battery Pack · faultedEPSU BATTERY FOR EMERGENCY LIGHT FAULTED. R & R THE LT ESPU BATTERY (11WL)SDR DALA2016102407546Battery Pack · no testDURING EMERGENCY LIGHT TEST, A PTP MESSAGE EPSU BATTERY AFT LEFT. R & R EPSU BATTERY.SDR DALA2016091306545Connector · disconnected5C EMERGENCY ISLE LIGHT INOPERATIVE. FOUND CONNECTOR AT FLOOR DISCONNECTED, RECONNECTED.SDR DALA2016060804438Connector · disconnectedROW 7C EMERGENCY LIGHT INOPERATIVE. REINSTALLED CONNECTOR.SDR DALA2015093005874Floor Panel · delaminatedAFT CARGO FLOOR PANEL 151ZG DELAMINATED. REMOVED AND REPLACED THE FLOOR PANEL IAW AMM 53-42-14, DWG NW3D25-40532.SDR DALA2015092805873Floor Panel · delaminatedAFT CARGO FLOOR PANEL 151VG DELAMINATED. FABRICATED A NEW FLOOR PANEL IAW DWG NW3025-40640.SDR DALA2015051603297Structure · bentL1 DOOR DOES NOT SHOW CLOSED. LOWER RT FLANGE AREA OF DOOR IS BENT. C/W ERA 535982-14 REV ORIG SEC 1, TEMP REPAIR TIME LIMITS TRACKED ON LOGS 1947568 AND 1948095.SDR DALA2015020501069Connector · disconnectedEMERGENCY EXIT LIGHTS INOPERATIVE ROWS 14 & 19, RECONNECTED CONNECTORS.SDR DALA13055873141Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 251UF DELAMINATED OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209.SDR DALA13052943141Skin · damagedSKIN AT FRAMES 70 - 71, STR 16 - 17 RIGHT DENTED. BLENDED GOUGE IAW SRM 51-73-00. NO ESTABLISHED LIMIT IAW SRM 53-51-11, TABLE 101. CUT OUT DAMAGE. FABRICATED REPAIR DOUBLER IAW SRM 53-00-11, FIG 230 AND INSTALLED IAW SRM 51-42-11 AND SRM 53-00-11, FIG 23SDR DALA13051553141Floorboard · damagedFLOORBOARD 127BF HAS TWO DAMAGED SCREW MOUNT HOLES. FOUND OUT OF LIMITS IAW SRM 53-12-00, DIAGRAM 101. FABRICATED NEW FLOORBOARD IAW SRM 53-12-00, FIG 206.SDR DALA13051543141Floorboard · damagedFLOORBOARD 127CF HAS FOUR DAMAGED SCREW MOUNT HOLES. FOUND OUT OF LIMIT IAW SRM 53-12-00, DIAGRAM 101. FABRICATED NEW FLOORBOARD IAW SRM 53-12-00, FIG 206.SDR DALA13051533141Floorboard · damagedFLOORBOARD 127DF HAS ONE DAMAGED SCREW MOUNT HOLE. FOUND OUT OF LIMIT IAW SRM 53-12-00 DIAGRAM 101. FABRICATED NEW FLOORBOARD IAW SRM 53-12-00, FIG 206.SDR DALA13051313141Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 161FF HAS PREVIOUS REPAIR & MULTIPLE DENTS. FOUND TO BE OUT OF LIMITS IAW SRM 53-02-00 103. AFT CARGO SLOPE PANEL FABRICATED IAW SRM 53-02-00, FIG 209 AND DWG NW3D25-40532.SDR DALA13051303141Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 161EF HAS FOUR PREVIOUS REPAIRS, MULTIPLE DENTS & DEEP SCRATCHES. FOUND TO BE OUT OF LIMITS IAW SRM 53-02-00, FIG 104. AFT CARGO SLOPE PANEL FABRICATED IAW SRM 53-02-00, FIG 9 AND DWG NW3D25-40532.SDR DALA13051293141Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 151DE HAS THREE PREVIOUS REPAIRS, MULTIPLE DENTS & DISBONDED. FOUND TO BE OUT OF LIMITS IAW SRM 53-02-00, FIG 103, AFT CARGO SLOPE PANEL FABRICATED IAW SRM 53-02-00 & DWG NW3D25-40532.SDR DALA13051283141Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 151UG HAS FOUR PREVIOUS REPAIRS, MULTIPLE DENTS & PUNCTURED. FOUND TO BE OUT OF LIMITS IAW SRM 53-02-00, FIG.104. FABRICATED SLOPE PANEL IAW SRM 53-02-00 & DWG 3D25-40532.SDR DALA13051273141Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 151TG HAS FOUR PREVIOUS REPAIRS, MULTIPLE DENTS & PUNCTURED. FOUND TO BE OUT OF LIMITS IAW SRM 53-02-00, FIG.104. FABRICATED SLOPE PANEL UNDER IAW SRM 53-02-00 & DWG 3D25-40532.SDR DALA13051263141Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 161CF HAS SEVEN PREVIOUS REPAIRS, MULTIPLE DENTS & PUNCTURED. FOUND TO BE OUT OF LIMITS IAW SRM 53-02-00, FIG.103. FABRICATED SLOPE PANEL IAW SRM 53-02-00, FIG 209 & DWG NW3D25-40532.SDR DALA13051253141Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 151FE HAS PREVIOUS REPAIRS, MULTIPLE DENTS & PUNCTURED. FOUND TO BE OUT OF LIMITS IAW SRM 52-02-00 FIG. 103. FABRICATED SLOPE PANEL IAW SRM 53-02-00, FIG 209 & DWG NW3D25-40532.SDR DALA13051243141Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 162CF HAS THREE PREVIOUS REPAIRS & MULTIPLE DENTS. FOUND TO BE OUT OF LIMITS IAW SRM 53-02-00, FIG 103. FABRICATED SLOPE PANEL IAW SRM 53-02-00, FIG 209 & DWG NW3D25-40532.SDR DALA13050883141Stringer · corrodedAFT CARGO BAY BETWEEN FRAMES 62-63, STRINGER 41R HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00. NO ALLOWABLE LIMIT IAW SRM 53-41-13, PAGE 101. REMOVED & INSTALLED STRINGER SECTION FABRICATED IAW DWG D53476433, DWG D53476345 & SRM 51-42-11.SDR DALA13050873141Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 162BF HAS SEVEN PREVIOUS REPAIRS & MULTIPLE DENTS. FOUND OUT OF LIMIT IAW SRM 53-02-00, FIG 103. FABRICATED NEW SLOPE PANEL BY IAW SRM 53-02-00, FIG 209 & DWG 3D25-40532.SDR DALA13050863141Floor Panel · damagedAFT CARGO BAY FLOOR PANEL 151VG HAS FIVE PREVIOUS REPAIRS & MULTIPLE DENTS. FOUND OUT OF LIMIT IAW SRM 53-02-00, FIG 103. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 & DWG 3D25-40532.SDR DALA13050853141Floor Panel · damagedAFT CARGO BAY SLOPE PANEL 161BF HAS PREVIOUS REPAIR, MULTIPLE DENTS & EDGE DAMAGE. FOUND OUT OF LIMIT IAW SRM 53-02-00, FIG 103. FABRICATED NEW SLOPE PANEL IAW SRM 53-02-00, FIG 209 & DWG 3D25-40532.SDR DALA13050843141Floor Panel · puncturedAFT CARGO BAY FLOOR PANEL 151PE HAS FIVE PUNCTURES & MULTIPLE DENTS. FOUND OUT OF LIMIT IAW SRM 53-02-00, FIG 103. FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00, FIG 209 & DWG 3D25-40532.SDR DALA13050833141Floor Panel · puncturedAFT CARGO BAY SLOPE PANEL 152TG HAS FOUR PREVIOUS REPAIRS, MULTIPLE DENTS & PUNCTURED. FOUND OUT OF LIMIT IAW SRM 53-02-00, FIG 103. FABRICATED NEW SLOPE PANEL 152TG IAW SRM 53-02-00, FIG 209 & DWG 3D25-40532.SDR DALA13050823141Floor Panel · puncturedAFT CARGO BAY SLOPE PANEL 151AE HAS PREVIOUS REPAIRS, MULTIPLE DENTS, PUNCTURED & EDGE DAMAGED. FOUND OUT OF LIMIT IAW SRM 53-02-00, FIG 103. FABRICATED NEW SLOPE PANEL IAW SRM 53-02-00, FIG 209 & DWG 3D25-40532.SDR DALA13050813141Floor Panel · puncturedAFT CARGO BAY SLOPE PANEL 151GE HAS MULTIPLE DENTS & PUNCTURED. FOUND OUT OF LIMIT IAW SRM 53-02-00, FIG 103. FABRICATED NEW SLOPE PANEL IAW SRM 53-02-00, FIG 209 & DWG 3D25-40532.SDR DALA13050803141Floor Panel · puncturedAFT CARGO BAY SLOPE PANEL 151HE HAS MULTIPLE DENTS & PUNCTURED. FOUND OUT OF LIMIT IAW SRM 53-02-00, FIG 103. FABRICATED NEW SLOPE PANEL 151HE IAW SRM 53-02-00, FIG 209 & DWG 3D25-40532.SDR DALA13050793141Floor Panel · puncturedAFT CARGO BAY SLOPE PANEL 151BE HAS FIVE PREVIOUS REPAIRS, MULTIPLE DENTS & PUNCTURED. FOUND TO BE OUT OF LIMIT IAW SRM 53-02-00, FIG 103. FABRICATED NEW SLOPE PANEL IAW SRM 53-02-00, FIG 209 & DWG 3D25-40532.SDR DALA13050783141Floor Panel · dentedAFT CARGO BAY FLOOR PANEL 151ZG HAS EIGHT PREVIOUS REPAIRS & MULTIPLE DENTS. FOUND TO BE OUT OF LIMIT IAW SRM 53-02-00, FIG 103, FABRICATED NEW FLOOR PANEL IAW SRM 53-02-00 FIG 209 & DWG 3D25-40532SDR DALA13050773141Seat Track · corrodedFORWARD CABIN SEAT TRACK -Y765 BETWEEN FRAMES 20-21 HAS CORROSION. REMOVED CORROSION IAW SRM 51-74-00, FOUND TO BE OUT OF LIMITS IAW SRM 53-11-15. REMOVED SEAT TRACK IAW SRM 51-42-11. ACCOMPLISHED REPAIR IAW SRM 53-11-15, FIG 206. CUTOUT DAMAGED SEAT TRACKSDR DALA13052993141Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 241AF DELAMINATED. FABRICATED FLOOR PANEL IAW SRM 53-02-00, FIG.209 & DWG 3D25-40640.SDR DALA13049323141Skin · damagedDURING CURRENT MAINTENANCE CHECK, SKIN AFT OF L1 DOOR, BETWEEN FRAME 21, STRINGERS 25-26L DAMAGED. REPAIRED IAW SRM 53-11-11, FIG 210.SDR DALA13048923141Floor Support · corrodedFORWARD UTILITY AREA FLOOR SUPPORT -Y254, BETWEEN FRAMES 16-20, UPPER FLANGE HAS CORROSION. BLENDED AREA IAW SRM 51-74-00. FOUND TO BE OUT OF LIMITS IAW SRM 53-11-15. R & R FLOOR SUPPORT IAW SRM 51-42-11 & TRM 53-21-01.SDR DALA13048913141Floor Panel · delaminatedAFT UTILITY FLOOR PANEL 261HG DELAMINATED AND FOUND OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FLOOR PANEL FABRICATED IAW SRM 53-02-00, FIG 9 AND DWG 3D25-40640.SDR DALA13048903141Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 221PF DELAMINATED AND FOUND OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FLOOR PANEL FABRICATED IAW SRM 53-02-00, FIG 9 AND DWG NW3D25-40640.SDR DALA13048893141Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 221EF DELAMINATED AND FOUND OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FLOOR PANEL FABRICATED IAW SRM 53-02-00 AND DWG 3D25-40640.SDR DALA13048883141Floor Panel · delaminatedMAIN CABIN FLOOR PANEL 261NF DELAMINATED AND FOUND OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FLOOR PANEL FABRICATED IAW SRM 53-02-00, FIG 102 AND DWG 3D25-40640.SDR DALA13048873141Floor Panel · delaminatedAFT UTILITY FLOOR PANEL 261PF, DELAMINATED, FOUND OUT OF LIMITS IAW SRM 53-02-00, FIG 102. FLOOR PANEL FABRICATED IAW SRM 53-02-00 AND DWG NWD25-40640.SDR DALA13048723141Stop Fitting · chafedLEFT AFT DOOR FRAME AT FRAME 68 MID ROLLER STOP FITTING CHAFED. BLENDED AREA IAW SRM 51-73-00. NO ESTABLISHED LIMIT ON SRM. R & R STOP FITTING IAW SRM 51-42-11 & DWG D53480082.SDR DALA13048713141Stop Fitting · chafedRIGHT AFT PASSENGER DOOR FRAME AT FRAME 68 MID ROLLER STOP FITTING CHAFED. BLENDED AREA IAW SRM 51-73-00. NO ESTABLISHED LIMITS IN SRM. R & R FITTING IAW SRM 51-42-11 & DWG D53480082.SDR DALA13048703141Floor Support · corrodedAFT UTILITY AREA FLOOR SUPPORT +Y1292 BETWEEN FRAMES 66-68 UPPER FLANGE HAS CORROSION. BLENDED AREAS AND FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15. REMOVED FLOOR SUPPORT IAW SRM 51-42-11. INSTALLED NEW FLOOR SUPPORT IAW TRM 53-21-01.SDR DALA13048693141Floor Support · corrodedAFT UTILITY AREA FLOOR SUPPORT +Y1292 BETWEEN FRAMES 68-69 UPPER FLANGE HAS CORROSION. BLENDED AREAS IAW SRM 51-74-00, FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15. REMOVED FLOOR SUPPORT IAW TRM 51-42-11. INSTALLED NEW FLOOR SUPPORT IAW TRM 53-21-01.
Back to N341NB