N375TA
Service difficulty reports not matched to an aircraft · 47
They name N375TA, but no registry record covers the date, the aircraft registered then was built later, or the report describes another aircraft. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N375TA' AND registry_match IS NULL ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N375TA' AND registry_match IS NULL ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR W8PA971497Lamp · inoperativeDEN- R1 DOOR OUTSIDE EMERGENCY LIGHT IS INOP. REPLACED LAMP, OPS CHECK GOOD.SDR W8PA971125Seal · tornAIRCRAFT WILL NOT HOLE PRESSURIZATION DESCENDED TO 17,000 FEET. REPLACED NR 2 CARGO DOOR SEAL. (M)SDR W8PA970179Lamp · failedBULL NOSE EMERGENCY LIGHT AT ROW 23R IS INOP. REPLACED LAMP. (M)SDR W8PA970108Cover · missingFLOOR TRACK LIGHT COVER MISSING AT ROW 6. INSTALLED FLOOR TRACK COVER. (M)SDR W8PA970052Galley Mounts · corrodedDURING C-CHECK, ALL FOUR OF THE G1 GALLEY MOUNTING FITTINGS ARE CORRODED, BS 273-288, RBL 13-42, WL 208. REMOVED CORROSION FROM THE GALLEY MOUNTS. ONE OF THE FOUR MOUNTS ARE IN LIMITS. THE OTHER THREE OUT OF LIMITS AND REPLACED PER SRM. (M)SDR W8PA970051Hat Channel · corrodedDURING C-CHECK, THE HAT CHANNEL AT BS 281-291, RBL 13, WL 208 IS CORRODED. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS. REMOVED DAMAGED CHANNEL, FABRICATED AND INSTALLED NEW HAT CHANNEL IAW SRM. (M)SDR W8PA970050Hat Channel · corrodedDURING C-CHECK, THE HAT CHANNEL AT BS 331-337, RBL 53, WL 208 IS CORRODED. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS. REMOVED HAT CHANNEL, FABRICATED AND INSTALLED NEW HAT CHANNEL IAW SRM. (M)SDR W8PA970049Floor Beam · corrodedDURING C-CHECK, THE UPPER CHORD OF THE FLOOR BEAM IS CORRODED AROUND THE FASTENER HOLES AT BS 360, LBL 18.5 - RBL 60, WL 208. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS FABRICATED AND INSTALLED NEW T-CHORD IAW SRM. (M)SDR W8PA970048Hat Channel · corrodedDURING C-CHECK, THE HAT CHANNEL IS CORRODED AT BS 336-345, RBL 10, WL 208. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS. REMOVED DAMAGED HAT CHANNEL, FABRICATED AND INSTALLED NEW CHANNEL IAW SRM. (M)SDR W8PA970047Hat Channel · corrodedDURING C-CHECK, THE HAT CHANNEL IS CORRODED AT BS 350, RBL 10-51, WL 208. FOUND CORROSION REMOVED, PART OUT OF LIMITS. REMOVED, FABRICATED NEW PART AND INSTALLED IAW SRM. (M)SDR W8PA970046Floor Beam · corrodedDURING C-CHECK, THE UPPER CHORD OF THE FLOOR BEAM IS CORRODED AROUND THE FASTENER HOLES AT BS 294, BL 0 - RBL 51, WL 208. REMOVED CORROSION, PART OUT OF LIMITS, FABRICATED AND INSTALLED NEW UPPER CHORD IAW SRM. (M)SDR W8PA970045Attach Fittings · corrodedDURING C-CHECK, ALL FOUR ATTACH FITTINGS FOR THE G2 GALLEY ARE CORRODED, BS 336 - 347, RBL 10-53, WL 208. REPLACED FOUR ATTACH FITTINGS WITH NEW PARTS IAW SRM. (M)SDR W8PA970044Hat Channel · corrodedDURING C-CHECK, THE HAT CHANNEL AT BS 289-294, RBL 42, WL 208 IS CORRODED. FABRICATED AND INSTALLED NEW PART IAW SRM. (M)SDR W8PA970043Web · crackedDURING C-CHECK, FOUND CRACK IN WEB, BS 294, RLB 14, WL 192. REMOVED AND FABRICATED NEW PART INSTALLED IAW SRM. (M)SDR W8PA970042Hat Channel · corrodedDURING C-CHECK, THE HAT CHANNEL IS CORRODED AT BS 275-286, RBL 42, WL 208. REMOVED CORROSION, FOUND TO BE OUT LIMITS. FABRICATED AND INSTALLED PER SRM. (M)SDR W8PA970041Floor Beam · corrodedDURING C-CHECK, THE UPPER CHORD OF THE FLOOR BEAM IS CORRODED AROUND FASTENER HOLES AT BS 312 FROM LBL 8 - RBL 50, WL 208. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS PER SRM, FABRICATED AND INSTALLED PER SRM. (M)SDR W8PA970036Stiffener · corrodedDURING C-CHECK, THE FLOOR SUPPORT AT BS 294-312, RBL 10, WL 208 IS CORRODED. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS PER SRM. REMOVED AND REPLACED FLOOR SUPPORT PER SRM. (M)SDR W8PA970035Angle · corrodedDURING C-CHECK, CORROSION ON R-1 DOORWAY THRESHOLD Z-ANGLE BS 298-347, RBL 60, WL 208. REMOVED CORROSION. FOUND TO BE OUT OF LIMITS PER SRM. REMOVED AND REPLACED Z-ANGLE PER SRM. (M)SDR W8PA970034Seat Track · corrodedDURING C-CHECK, THE LBL 22 SEAT TRACK IS CORRODED ON THE FLANGES BS 344-364, LBL 22, WL 208. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS PER SRM. REMOVED AND REPLACED SEAT TRAC PER SRM. (M)SDR W8PA970033Seat Track · corrodedDURING C-CHECK, FOUND CORROSION, THE LBL 42 SEAT TRACK IS CORRODED ON THE FLANGES BS 344-349 LBL 42, WL 208. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS. REMOVED DAMAGED SEAT TRACK AND INSTALLED NEW SEAT TRACK IAW SRM. (M)SDR W8PA970027Frame · corrodedDURING C-CHECK, FOUND CORROSION ON FRAME AT BS 847, RBL 21, WL 161. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS PER SRM. REMOVED AND REPLACED WEB PER SRM. (M)SDR W8PA970025Web · crackedDURING C-CHECK, FOUND CRACK IN WEB ON FORWARD AIRSTAIR DOOR, BS 340, LBL 73, WL 180. REMOVED DAMAGED AREA, FABRICATED AND INSTALLED IAW SRM. (M)SDR W8PA970040Floor Track · corrodedDURING C-CHECK, FOUND CORROSION ON CARGO FLOOR TRACK, BS 847, RBL 14, WL 161. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS, FABRICATED AND INSTALLED NEW FLOOR TRACK PER SRM. (M)SDR W8PA970032Hat Channel · corrodedDURING C-CHECK, FOUND CORROSION ON HAT SECTION AND DOUBLER, INBOARD SIDE OF FWD LAV SERVICE PANEL, BS 280, RBL 50, WL 178. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACED HAT SECTION AND DOUBLER IAW SRM. (M)SDR W8PA970024Floor Track · corrodedDURING C-CHECK, FOUND CORROSION ON CARGO FLOOR TRACK, BS 847, RBL 14, WL 161. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS. FABRICATED AND INSTALL NEW FLOOR TRACK IAW SRM. (M)SDR W8PA970026Cargo Track · corrodedDURING C-CHECK, FOUND CORROSION ON CARGO TRACK AT BS 500C - BS 500D, RBL 18, WL 155. REMOVED DAMAGED SECTION, FABRICATED NEW PART AND INSTALL IAW SRM. (M)SDR W8PA970022Floor Beam · corrodedDURING C-CHECK, FOUND CORROSION ON CARGO FLOORBEAM, BS 825, RBL 8, WL 158. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS PER SRM. REMOVED DAMAGED AREA, FABRICATED AND INSTALLED PART IAW SRM. (M)SDR W8PA970053Floorsupport · corrodedDURING C-CHECK, FOUND CORROSION ON FLOORSUPPORT AT BS 312-328, LBL 11, WL 208. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS PER SRM. REMOVED AND REPLACED FLOORSUPPORT IAW SRM. (M)SDR W8PA970039Angle · corrodedDURING C-CHECK, THE ANGLE UNDER THE R1 DOOR WAY MOP SILL IS CORRODED, BS 312-328, RBL 57, WL 208. REMOVED AND INSTALLED NEW ANGLE PER SRM. (M)SDR W8PA970038Web · corrodedDURING C-CHECK, FOUND WEB UNDER R1 DOOR MOP SILL TO BE CORRODED FROM BS 294.5 TO 328, RBL 61, WL 208. REMOVED, FABRICATED NEW WEB AND INSTALLED PER SRM. (M)SDR W8PA970031Suuport · crackedDURING C-CHECK, FLOOR TO SIDE WALL SUPPORT WEB CRACKED AROUND NUT PLATE AT BS 847, RBL 18, WL 160. REMOVED DAMAGED PART FABRICATED AND INSTALLED IAW SRM. (M)SDR W8PA970030Floorbeam · corrodedDURING C-CHECK, THE UPPER CHORD OF BS 328 FLOORBEAM IS CORODED AROUND FLOORBOARD FASTENER HOLES FROM BL 0 TO RBL 59, WL 208. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS IAW SRM. REMOVED, FABRICATED AND INSTALLED REPAIR PARTS IAW SRM. (M)SDR W8PA970029Floor Support · corrodedDURING C-CHECK, FOUND CORROSION ON FLOOR SUPPORT BS 328-344, LBL 11, WL 208. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS PER SRM. REMOVED AND INSTALLED NEW SUPPORT IAW SRM. (M)SDR W8PA970028Floor Support · corrodedDURING C-CHECK, FOUND CORROSION ON FLOOR SUPPORT AT BS 312-328, RBL 10, WL 208. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS PER SRM. REMOVED AND REPLACED FLOOR SUPPORT IAW SRM. (M)SDR W8PA970023Skin · crackedDURING C-CHECK, FORWARD CARGO DOOR INNER SKIN HAS 1 INCH CRACK AT FORWARD CENTER LIGHTING HOLE. STOP DRILLED HOLE. FABRICATED DOUBLER AND INSTALL ALL WORK DONE IAW SRM. (M)SDR W8PA970021Floorbeam · corrodedDURING C-CHECK, FOUND CORROSION ON CARGO FLOORBEAM BS 860, RBL 13, WL 162. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS PER SRM. REMOVED DAMAGED AREA, FABRICATED AND INSTALLED REPAIR PARTS IAW SRM. (M)SDR W8PA970018Floorbeam · corrodedDURING C-CHECK, FOUND CORROSION ON CARGO FLOORBEAM BS 860, RBL 8 WL 162. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS PER SRM. REMOVED DAMAGED AREA, FABRICATED AND INSTALLED REPAIR PARTS IAW SRM. (M)SDR W8PA970037Mop Sill · corrodedDURING C-CHECK, THE R1 DOORWAY MOP SILL IS CORRODED, BS 286-372, RBL 61, WL 208. REMOVED, AND INSTALL NEW CHORD, PER SRM. (M)SDR W8PA970020Strap · corrodedDURING C-CHECK, FOUND CORROSION ON FLOOR STRAP BS 860 RBL 20 TO LBL 20 WL 162. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS PER SRM. FABRICATED NEW STRAP PER SRM AND INSTALLED. (M)SDR W8PA970019Support · corrodedDURING C-CHECK, FOUND CORROSION ON FLOOR TO SIDEWALL SUPPORT BS 947 TO 867 RBL 18. REMOVED CORROSION, FOUND TO BE OUT OF LIMITS PER SRM. REMOVED AND REPLACED SUPPORT PER SRM. (M)SDR W8PA970006Bulb · burned outAFTER SELECTING 'GEAR DOWN' ON APPROACH, RIGHT MAIN LANDING GEAR DID NOT INDICATE DOWN. SWAPPED BULBS, DETERMINED FAULTY LIGHT BULB. DID FLYBY. RELAMPED GEAR DOWN INDICATOR LIGHT. (M)SDR W8PA970005Socket · looseFOUND EMERGENCY TRACK LIGHT WILL NOT ILLUMINATE, LAST ROW. RECONNECTED LIGHT SOCKET. (M)SDR W8PA960187Battery Charger · failedEMERGENCY LIGHTS WILL NOT ILLUMINATE, ROWS 19 THROUGH 22. REPLACED BATTERY CHARGER. (M)SDR W8PA960147Lens · missingRIGHT AFT EMERGENCY EXIT LIGHT LENS IS OFF. RE-INSTALLED LENS. (X)SDR W8PA960146Battery · dischargedFLOOR TRACK LIGHTING INOP FROM ROWS 14 THROUGH 20. REMOVED AND REPLACED BATTERY ASSY. (X)SDR W8PA960141Bulb · failedLEFT AFT BODY FAIRING EMERGENCY LIGHT INOP. REPLACED BULB. (M)SDR W8PA960056Bulb · failedFOUND EXTERNAL EMERGENCY EXIT LIGHT INOPERABLE FOR R-1 DOOR. RELAMPED LIGHT ASSEMBLY. (X)
Back to N375TA