N413UP
Service difficulty reports · 256
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N413UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N413UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA2575727Cargo Track · corrodedINSPECTION TYPE: C, MAIN CARGO TRACK BS 879-900 4 EACH FASTENER HOLE CORRODED LBL 44. FABRICATED AND INSTALLED NEW CARGO TRACK EXPANSION JOINT SECTION FROM BS 879-900 LBL 45 IAW DWG 143N5470.SDR IPXA2575705Floorboard · damagedINSPECTION TYPE: C, MAIN CARGO FLOORBOARD 212XAF HAS DAMAGE. FABRICATED FLOORBOARD IAW EO B757-5320-9692-H.SDR IPXA2575759Skin · dentedINSPECTION TYPE: C, FWD CARGO BAY HAS DENT IN SKIN BS 817 BETWEEN 23R AND 24R. CUT OUT DENT, FABRICATED AND INSTALLED DOUBLER IAW SRM 53-00-01-2R, REPAIR 3.SDR IPXA12575783Frame · dentedINSPECTION TYPE:C-CK, FWD CARGO COMPARTMENT STA 820 AT STR 24 LT DENTED. REPAIRED IAW SRM 53-00-07-2R, REPAIR 5, DETAIL III.SDR IPXA20110916001JFloor Panel · damagedMAIN DECK FLOOR PANEL NR12 AT BS 460, RBL 50 IS DAMAGED. R & R FLOOR PANEL REF NR 475585SDR IPXA20110916001IFloor Panel · damagedMAIN DECK FLOOR PANEL NR1 AT BS 340, LBL 50 IS DAMAGED. R & R FLOOR PANEL REF NR 475584.SDR IPXA20110916001HFloor Panel · damagedFLOOR PANEL NR 8 AT STA 460, LBL 30, MAIN DECK FLOOR PANEL DAMAGED. R & R FLOOR PANEL REF NR 475583SDR IPXA20110916001GFloor Panel · damagedFLOOR PANEL NR 11 AT BS 460, RBL 30 MAIN DECK FLOOR PANEL DAMGED. R & R FLOOR PANEL REF NR 475582.SDR IPXA20110916001FFloor Panel · damagedFLOOR PANEL NR 10 AT STA 460, RBL 5 MAIN DECK FLOOR PANEL DAMAGED. R & R FLOOR PANEL REF NR 475581SDR IPXA20110916001EFloor Panel · damagedFLOOR PANEL NR 9 AT BS 460, LBL20, MAIN DECK FLOOR PANEL DAMAGED. R & R FLOOR PANEL REF NR 475580.SDR IPXA20110916001DFloor Panel · damagedFLOOR PANEL POSITION NR 7 AT STA 460, LBL 50 MAIN DECK FLOOR PANEL DAMAGED. R & R FLOOR PANEL REF NR 475579.SDR IPXA20110916001CFloor Panel · damagedFLOOR PANEL AT STA 340, RBL 30. MAIN CARGO DECK FLOOR PANEL DAMAGED, NR 5. R & R FLOOR PANEL REF NR 475578.SDR IPXA20110916001BFloor Panel · damagedREF BOW NR 2390, POSITION AT STA 340, RBL5 MAIN CARGO DECK FLOOR PANEL DAMAGED NR4. R & R FLOOR PANEL REF NR 475577SDR IPXA20110916001AFloorboard · damagedREF BOW NR 2390, POSITION AT STA 340, LBL 5. MAIN CARGO DECK FLOORBOARD DAMAGED (LBL 5) NR3. R & R FLOORBOARD REF NR475576.SDR IPXA1564320Sensor · inoperativeSTATUS MESSAGE LANDING GEAR MONITOR DISPLAYED. R & R NOSE GEAR LOCKED SENSOR, S10078, IAW MM 32-61-03- 02, STEPS 2C, 2E AND 3E PERFORMED GOOD TEST IAW MM 32-61-03-2, STEPS 5E- F.SDR IPXA1564316Wire · shortedADVISED FLIGHT CONTROL 15 MINUTES AFTER DEPARTURE THAT THEY WERE RETURNING TO DEPARTURE. ACFT HAD NR 3 WINDOW HEAT AND LANDING GEAR EICAS MESSAGE COMING OUT OF A "C" CHECK. T/S TESTS FOUND OPEN IN NR3 SENSOR LOOP FOUND BROKEN TERMINAL AT PIN 5 OF D415 96P, RSDR IPXA1564263Structure · damagedINSPECTION TYPE:C2, WHILE WORKING CUSTOMER CARD 917150 MISDRILLED NR2 ENG PYLON STRUCTURE PN 313N3100-65. FABRICATED AND INSTALLED REPAIR DOUBLER AND FILLER IAW SRM 51-70-11-0G, SRM 51-40-05-0G, SRM 51-20-01-0G AND AMM 51-20-00 AND SRM 51-40-02-0G AND DWG 313SDR IPXA1564259Frame · dentedINSPECTION TYPE:C2, WHILE VISUALLY INSPECTING THE REPAIR AREA UNDER THE REPAIR ON CARD 917047 FOUND BS 1480 FRAME INNER FLANGE DENTED 5 INCHES BELOW STR 25L. REPAIRED IAW SRM 53-00-07-2R 5.SDR IPXA1564226Skin · bulgedINSP TYPE:C2, WHILE WORKING C917121, NR 1 ENGINE OTBD CORE COWL UPPER AFT EXT. SKIN BULGING, R & R.SDR IPXA11564041Intercostal · damagedINSPECTION TYPE:C2, INTERCOSTAL CAP DAMAGED AT BS 900, RBL 25-45 WL 208. R & R INTERCOSTAL AND CAP IAW SRM 51-40-02-0G.SDR IPXA1564031Floor Panel · damagedINSPECTION TYPE:C2, MAIN CARGO BAY FLOOR PANEL HAS EDGE DAMAGE BS 1055-1100, RBL 45-65, WL 208 (DAMAGE BEYOND SRM LIMITS). FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR IPXA1564021Floor Panel · damagedINSPECTION TYPE:C2, MAIN CARGO FLOOR PANEL HAS EDGE DAMAGE BS 1060-1100, BL 0-RBL 25. REMOVED, FABRICATED REPLACEMENT PANEL, IAW EO B757-5320-9692-G.SDR IPXA1564020Floor Panel · damagedINSPECTION TYPE:C2, MAIN CARGO FLOOR PANEL HAS EDGE DAMAGE BS 900-1020 RBL 45-65, WL 208.1. REMOVED AND FABRICATED REPLACEMENT PANEL IAW EO B757-5320-9692-G.SDR IPXA1564019Floor Panel · damagedINSPECTION TYPE:C2, MAIN CARGO FLOOR PANEL HAS EDGE DAMAGE BS 900-1020, BL 0-LBL 25. REMOVED AND FABRICATED REPLACEMENT PANEL, IAW EO B757-5320-9692-G.SDR IPXA1564022Floorbeam · corrodedINSPECTION TYPE:C2, FUSE,UPPER LOBE, CORROSION ON FLOOR SUPPORT TO OP CHORD, BETWEEN CHORD AND CAP PLATE, BS 1020, WL 208, LBL 25 TO 45. R & R SUPPORT IAW 51-40-02-OG, 51-40-05-0G.SDR IPXA1563973Floor Panel · damagedINSPECTION TYPE:C2, FLOOR PANEL HAS EDGE DAMAGE AT BS 1020-1055, WL 208, RBL 45-RBL 65. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G, EO B757-5100-33281-B, AND SRM 53-00-50-1A-1, FIG 101.SDR IPXA1563972Floor Panel · damagedINSPECTION TYPE:C2, FLOOR PANEL HAS EDGE DAMAGE AT BS 900-1020, WL 208, BL0-RBL25. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G, EO B757-5100-33281-B, AND SRM 53-00-50-1A-1.SDR IPXA1563971Floor Panel · damagedINSPECTION TYPE:C2, FLOOR PANEL HAS EDGE DAMAGE AT BS 900-1020, WL 208, RBL25-RBL45. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G, EO B757-5100-33281-B, AND SRM 53-00-50-1A-1, FIG 101.SDR IPXA1563970Floor Panel · damagedINSPECTION TYPE:C2, FLOOR PANEL HAS EDGE DAMAGE AT BS 1020-1055, WL 208, LBL25-LBL45. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G, EO B757-5100-33281-B, AND SRM 53-00-50-1A-1, FIG 101.SDR IPXA1563969Floor Panel · damagedINSPECTION TYPE:C2, FLOOR PANEL HAS EDGE DAMAGE AT BS 900-1020, WL 208, LBL 25-LBL 45. REPLACED FLOOR PANEL BS 900-1020 LBL 25-LBL45 IAW EO B757-5320-9692-G, EO B757-5100-33281-B, AND SRM 53-00-50-1A-1, FIG 101.SDR IPXA1563968Floor Panel · damagedINSPECTION TYPE:C2, FLOOR PANEL HAS EDGE DAMAGE AT BS 1020-1055, WL 208, LBL 45-LBL 65. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G, EO B757-5100-33281-B, AND SRM 53-00-50-1A-1, FIG 101.SDR IPXA1563967Floor Panel · damagedINSPECTION TYPE:C2, FLOOR PANEL HAS EDGE DAMAGE AT BS 900-1020, WL 208, LBL 45 - LBL 65. REPLACED FLOOR PANEL IAW EO B757-5320-9692-G, EO B757-5100-33281-B, AND SRM 53-00-50-1A-1, FIG 101.SDR IPXA1564228Support Fitting · gougedINSPECTION TYPE:C2, WHILE ACCOMPLISHING CUST CARD NR B757-5750-12011K, FOUND RT TRUNNION BEARING OTBD SUPPORT FITTING, LWR OTBD FACE HAS 5 EA GOUGES. REPAIRED FITTING IAW EO B757-5720-41049-A, DATED 1/14/11 AND ATS ER 11-01001, DATED 14JAN11.SDR IPXA11564102Floor Support · damagedINSPECTION TYPE:C2, MISDRILLED HOLE IN FLOOR SUPPORT AT BS 1055, RBL 63, WL 208 (DAMAGED BEYOND SRM LIMITS). REMOVED, FABRICATED REPLACEMENT SUPPORT AND INSTALLED REPLACEMENT SUPPORT IAW SRM 51-40-02.SDR IPXA11564099Intercostal · damagedINSPECTION TYPE:C2, MISDRILLED HOLE IN INTERCOASTAL AT BS 1055, RBL63, WL 208 (DAMAGED BEYOND SRM LIMITS). REMOVED FABRICATED REPLACEMENT SUPPORT AND INSTALLED REPLACEMENT SUPPORT IAW SRM 51-40-02.SDR IPXA1564014Intercostal · damagedINSPECTION TYPE:C2, INTERCOSTAL CAP DAMAGED BS 900, WL 208, LBL 2-23. (DAMAGE IS BEYOND SRM LIMITS). REMOVED, FABRICATED AND INSTALLED REPLACEMENT HAT SECTION IAW SRM 51-40-02.SDR IPXA1563999Intercostal · damagedINSPECTION TYPE:C2, INTERCOSTAL CAP DAMAGED BS 900, WL 208, LBL 2-23 (DAMAGED IS BEYOND SRM LIMITS). REMOVED, FABRICATED AND INSTALLED REPLACEMENT HAT SECTION IAW SRM 51-40-02.SDR IPXA1563998Intercostal · damagedINSPECTION TYPE:C2, INTERCOSTAL CAP DAMAGED AT BS 900 WL 208 LBL 28. REMOVED, FABRICATED AND INSTALLED REPLACEMENT CAP IAW SRM 51-40-02.SDR IPXA1564175Skin · damagedINSPECTION TYPE:C2, SCRIBE MARKES IN THE FUSELAGE SKIN AT BS 780-810, STR 18L-17L WHERE THE FAIRING SEALS TO THE SKIN. REPAIRED IAW EO B757-5330-41034-A.SDR IPXA1564174Panel Support · corrodedINSPECTION TYPE:C2, FWD CARGO BAY RT FLOOR TO SIDEWALL SUPPORT IS CORRODED AT BS 780 TO BS 820 AROUND TIE DOWN LOCATIONS. R & R FLOOR TO SIDEWALL PANEL IAW SRM 51-40-02, 51-40-06, 51-20-01 AND AMM 51-20-00-0.SDR IPXA11564147Panel Support · crackedINSPECTION TYPE:C2, FWD CARGO BAY RT FLOOR TO SIDEWALL SUPPORT IS CRACKED AT BS 735 (DAMAGE IS BEYOND SRM LIMITS). R & R PANEL IAW SRM 51-40-02.SDR IPXA11564106Support · corrodedINSPECTION TYPE:C2, AFT CARGO BAY DOOR THRESHOLD INBD SUPPORT IS CORRODED AT NUTPLATES, RBL 20 BS 1380-1440 (DAMAGE IS BEYOND SRM LIMITS). R & R PANEL IAW SRM 51-40-02.SDR IPXA11564093Skin Panel · delaminatedINSPECTION TYPE:C2 VERTICAL STAB, AREA OF DELAMINATION ON LT L/E FIXED PANEL, 24 INCHES FROM L/E, 11 INCHES FROM BOTTOM OF PANEL CUTOUT 322CL (HF ANTENNA). R & R PANEL ASSY IAW SRM 51-40-02.SDR IPXA11564062Support · corrodedINSPECTION TYPE:C2, CORROSION ON LT FLOOR TO SIDEWALL SUPPORT AT BS 690 TO BS 750 INBD NUT PLATES AREA. REPLACED FLOOR TO SIDEWALL SUPPORT. (SIDE PANEL) BS765-645, LBL20, WL156 IAW SRM 51-40-02, SRM 51-10-02, SRM 53-30-53-0I-1, SRM 53-00-53-1A1, AMM 25-50-02,SDR IPXA1564017Stringer Clip · brokenINSPECTION TYPE:C2, STRINGER CLIP AT BS 1806, STR 6 BROKEN. R & R STR CLIP IAW SRM 51-40-02-0G, 51-40-05-0G, 51-40-06-0G.SDR IPXA1564227Support Bracket · crackedINSPECTION TYPE:C2, LT MLG WHEEL STA 1170, LBL 70 PRESS/CD FITTER MOD L SYS AFT SUPPORT BRACKET CRACKED. R & R AFT SUPPORT BRACKET IAW AMM 29-11-15-4, AMM 20-10-09-4, SRM 51-40-02-0G, SRM 51-40-05-0G.SDR IPXA1564220Skin · chafedINSPECTION TYPE:C2 RT WING INBD FLAP LOWER L/E IS CHAFED JUST OTBD OF OTBD CARRIAGE. REPAIRED IAW ATS ER 11-01023 DATED 01-14-11, SRM 51-70-10.SDR IPXA11564060Wedge · chafedINSPECTION TYPE:C2, NR8 SLAT CHAFED LOWER SURFACE T/E AT INBD MAIN TRACK LOCATION. REPAIRED NR8 SLAT T/E WEDGE ASSY IAW SRM 57-43-02-1A1, FIG101, SRM57-43-02-0I-1, SRM51-70-10-2R, SRM57-43-02-1A-1 FIG 101, SHT 3 AND 4, NOTE M.SDR IPXA1564018Plate · crackedINSPECTION TYPE:C2, LT WING LWR WIGGLE PLATE (OTBD) CRACKED INBD OF THE NR 5 SPOILER ACTUATOR (DAMAGE IS BEYOND SRM LIMITS). R & R WIGGLE PLATE IAW SRM 51-40-02.SDR IPXA1564000Access Panel · corrodedINSPECTION TYPE:C2, ACCESS PANEL 198KR HAS CORROSION ON THE INNER SURFACE (DAMAGE IS BEYOND SRM LIMITS). FABRICATED REPLACEMENT PANEL IAW SRM 51-20-01.
Back to N413UP