N461SW
Service difficulty reports · 235
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N461SW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N461SW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA2025F01384Floorbeam · gougedTHE FLOORBEAM ATTACHMENT AT LBL 9 THAT ATTACHES TO THE REAR PRESSURE BULKHEAD IS GOUGED. (C-CHECK RO 09/24/2025)REPAIRED FLOORBEAM ATTACHMENT AT LBL 9 THAT ATTACHES TO THE REAR PRESSURE BULKHEAD IAW REO 601R-53-61-8364 REV -- DATED 2025-08-04 SKY CARD 51-900SDR SWIA202509250725Hinge · damagedPASSENGER DOOR HINGE ON FUSELAGE HAS 26 OF 27 HOLES IN HINGE LUGS ELONGATED. (TOOL USED G670-521104-101). (C-CHECK RO 09/24/2025)REMOVED AND REPLACED NEW PASSENGER DOOR HINGE ON FUSELAGE SIDE. REF. CRJ200 SRM 53-21-23 REPAIR NO. 1 AND REO 601R-53-21-656 REV.-SDR SWIA2025F01390Floorbeam · corrodedSTRAP ON THE PRESSURE FLOOR BEAM BL27L TO SILL -BL43L FS559.00 HAS TWO AREAS OF CORROSION. MARKED (C-CHECK RO 09/24/2025)BLENDED CORROSION FROM STRAP FROM PRESSURE FLOOR BEAM BL27L TO SILL BL43L AT FS559.00 AREAS 2 EA REF: CRJ 200 SRM 51-21-06-00. MATERIAL LOSDR SWIA2025F01389Web · corrodedCORROSION FOUND ON LOWER WEB BETWEEN FS 333.0 AND 349.0 AT INTERCOSTAL 20R. MARKED (C-CHECK RO 09/24/2025)REPLACED INTERCOSTAL 20R BTWN FS333.0-FS349.0 REF. DWG 601R38303 REV. -AR, CRJ200 SRM 51-42-06 AND CRJ200 SRM 51-42-21 AND COMPLIED WITH TASK CARD 51-90SDR SWIA2025F01388Floorbeam · corrodedSTRAP ON THE PRESSURE FLOOR BEAM BL27R TO SILL -BL43R FS559.00 HAS MULTIPLE AREAS OF CORROSION. MARKED (C-CHECK RO 09/24/2025)COMPLETED REPLACEMENT OF STRAP ON PRESSURE FLOOR BEAM RBL 27 TO RBL 43 AT FS 559.00 AS PER CRJ200 SRM 51-42-06 & DWG 601R31025 REV: SDR SWIA2025F01387Floor Support · corrodedRIGHT PRESSURE FLOOR SILL ANGLE, FS409.0+128 TO FS559.0, HAS MULTIPLE AREAS OF CORROSION. MARKED (C-CHECK RO 09/24/2025)REPAIRED RH PRESSURE FLOOR SILL ANGLE FS409.0+128 TO FS559.0 4 LOCATIONS IAW REO 601R-53-41-666 REV C DATED 2012-11-06, REO 601R-53-41-33SDR SWIA2025F01386Floorbeam · corrodedPRESSURE FLOOR SUPPORT BEAM, BL27R, OUTBOARD FLANGE HAS CORROSION, FS559.00. MARKED (C-CHECK RO 09/24/2025)REPAIRED PRESSURE FLOOR SUPPORT BEAM AT RBL 27 FS 559 IAW ALL STEPS OFL REO 601R-53-41-3343 REV -- DATE 2025-08-14. COMPLIED WITH M-337 AND SKYWEST TASSDR SWIA2025F01385Web · corrodedRIGHT PRESSURE FLOOR SILL WEB, FS409.0+128 TO FS559.0, HAS MULTIPLE AREAS OF CORROSION. MARKED (C-CHECK RO 09/24/2025)REMOVED CORROSION ON 7EA AREAS AT RH PRESSURE FLOOR SILL WEB, FS409.0+128 TO FS 559.0, REF. CRJ-200, SRM 51-21-06. COMPLIED WITH STEPS 1-7 RSDR SWIA202509250724Web · corrodedLEFT PRESSURE FLOOR SILL WEB, FS409.0+128 TO FS559.0, HAS MULTIPLE AREAS OF CORROSION. MARKED (C-CHECK RO 09/24/2025)REPAIRED LEFT PRESSURE FLOOR SILL WEB, FS409.0+128 TO FS559.0 IAW REO 601R-53-41-3342 REV -- DATED 2025-08-22 AND COMPLIED WITH TASK CARD 51-9SDR SWIA202509250723Frame · corrodedCORROSION NOTED ON FRAME 349 BETWEEN STGR 26L TO STGR 26R. (S/N#000358) (C-CHECK RO 09/24/2025)REMOVED AND REPLACED FRAME SECTION AT FS349 BETWEEN STGR 23L AND 23R REF. CRJ-200 SRM 51-42-06, SRM 51-42-21, AND BOMBARDIER DWG# 601R32005 REV. AP AND COMPLIED WITSDR SWIA202509250722Skin · damagedLEFT OUTBOARD FLAP UPPER SKIN HAS 3 SMOKING RIVETS NEAR THE FORWARD EDGE IN THE CENTER OF THE FLAP. MARKED (C-CHECK RO 09/24/2025)REMOVED (3EA) SMOKING RIVETS ON LEFT OUTBOARD FLAP UPPER SKIN NEAR THE FORWARD EDGE IN THE CENTER OF THE FLAP, REF CRJ 200 SRM 51SDR SWIA2025F01392Skin · corrodedCORROSION ON EXTERNAL SKIN AND AROUND FASTENER HEADS BETWEEN FS559.00 - 559.00+32 & STGR26L -26R. MARKED (C-CHECK RO 09/24/2025)REPAIRED EXTERNAL SKIN AND AROUND FASTENER HEADS BETWEEN FS559.00 - 559.00+32 & STGR26L -26R IAW REO 601R-53-51-714 REV -- DATED 2SDR SWIA2025F01391Skin · corrodedCORROSION ON EXTERNAL SKIN AND AROUND FASTENER HEADS BETWEEN FS559.00+32 - 559.00+80 & STGR26L -26R. MARKED (C-CHECK RO 09/24/2025)REPAIRED EXTERNAL SKIN AND AROUND FASTENER HEADS BETWEEN FS559.00+32 - 559.00+80 & STGR26L -26R IAW REO 601R-53-51-715 REV -- DSDR SWIA202509250721Skin · corrodedCORROSION ON EXTERNAL SKIN AND AROUND FASTENER HEADS BETWEEN FS559.00+80 - 559.00+112 & STGR25L -25R. MARKED (C-CHECK RO 09/24/2025)REPAIRED EXTERNAL SKIN AROUND FASTENER HOLES @FSFS559.00+80 - 559.00+112 & STGR25L -25R AND REPAIRED IAW REO 601R-53-51-713 RESDR SWIA2025F01393Fastener · corrodedMULTIPLE CORRODED FASTENERS UNDER PANEL 196AL, 192BB AND 191BB. (C-CHECK RO 09/24/2025)REPAIRED COROSION ON SKIN AND FASTENERS UNDER PANEL LANDINGS 196AL, 192BB, AND 191BB REF CRJ200 SRM 51-21-06. COMPLIED WITH STEPS 1-4 OF REO 601R-53-00-916 REV -- DATED 202SDR SWIA202509250717Stop Fitting · gougedPASSENGER DOOR UPPER PIN STOP FITTING IS GOUGED, FS310.00. (C-CHECK RO 09/24/2025)REPAIRED PAX DOOR UPPER PIN STOP FITTING IAW REO 601R-53-21-3762, REV. --, DATE: 2025-07-25 AND COMPLIED WITH TASK CARD 51-900-1003-SKYSDR SWIA2025F01330Housing · gougedEXTERNAL SERVICE DOOR HANDLE HOUSING HAS GOUGES, HN00252768 (C-CHECK RO 09/24/2025)BLENDED OUT DAMAGE TO SERVICE DOOR EXTERNAL HANDLE HOUSING AND COMPLIED WITH ALL STEPS OF REO 601R-52-41-533, REV --, 2025-07-25 AND ALL STEPS OF GREO 601R52-41-235, REV. -ASDR SWIA202509250715Housing · gougedEXTERNAL CARGO DOOR HANDLE HOUSING HAS GOUGES, HN00252765 (C-CHECK RO 09/24/2025)REMOVED AFT CARGO DOOR HANDLE HOUSING. REF. CRJ200 SRM 51-42-21 AND INSTALLED NEW AFT CARGO DOOR HANDLE HOUSING. REF. CRJ200 SRM 51-42-21 AND DWG# CC670-38702 REV. F SHEET 1 SDR SWIA202501270025Yaw Damper · uncontrollableUNCOMMANDED YAW MOTION FOLLOWED BY YD 2 INOP MULTIPLE TIMES DURING FLIGHT. (FLIGHT 5066) REMOVED AND REPLACED THE YAW DAMPER PANEL PER CRJ200 AMM 22-22-04. OPS CHECK GOOD AT THIS TIME. A/C OK TO SERVICE. AIRCRAFT REMAINS IN CAT II STATUSSDR SWIA2023011225None · corroded*CORROSION IN THE RADIUS OF STGR20L UPPER END CLIP JUST AFT OF FS559.00+112 (MARKED) (C-CHECK RO 3/7/2023) REMOVED AND REPLACED STRINGER 20L CLIP AFT FS 559+112 REF CRJ 200 SRM 51-42-06 AND SRM 51-42-21 AND DWG 601R31057 REV. J. COMPLIED WITH 51-90SDR SWIA20230201025None · corroded*CORROSION IN THE RADIUS OF STGR19L UPPER END CLIP JUST AFT OF FS559.00+112 (MARKED) (C-CHECK RO 3/7/2023) REMOVED AND REPLACED STRINGER 19L CLIP AFT FS 559+112 REF CRJ 200 SRM 51-42-06 , AND CRJ 200 SRM 51-42-21 AND DWG 601R31057 REV. J. COMPLIED WISDR SWIA202302025None · corroded*SEVERAL SPOTS OF CORROSION ON R/H FLOOR SILL BETWEEN FS559.00+96 AND FS559.00+112 (MARKED) (C-CHECK RO 3/7/2023) REPLACED CORRODED RH FLOOR SILL BETWEEN FS559.00+96 AND FS559.00+112 WITH NEW PN 601R31133-102 PO# T-69191 REF CRJ 200 SRM 51-42-06 , BOMBSDR SWIA2023020024None · crackedAFT EQUIPTMENT BAY JUST AFT OF PRESSURE BULKHEAD LH OUTBD BETWEEN FS 621-625 APPROX WL 106 CLIP FOR INTERCOSTAL IN LINTEL REPAIR HAS A POSSIBLE CRACK (C-CHECK RO 3/7/2023) REMOVED AND REPLACED CLIP REF CRJ 200 SRM 51-42-06, AND DWG 601-35012 , REV-D, SDR SWIA2023020018None · damagedPAX DOOR CUTOUT SEAL STRIKER DAMAGED AT EXISTING REPAIR FS310.0 APPROX STRG 6-7 AS MARKED (C-CHECK RO 3/7/2023) REMOVED PREVIOUS EXISTING DOUBLER AND REPLACED WITH NEW DOUBLER REF CRJ200 REO 601R-53-22-033, REV -D, DATED 2014-02-17. TYPE I, LEAK CHECKSDR SWIA20230200016None · chafedRH INBOARD FLAP VANE OUTBOARD LEADING EDGE CHAFTED(MARKED). (C-CHECK RO 3/7/2023) REMOVED DAMAGE FROM RH INBOARD FLAP VANE OUTBOARD LEADING EDGE REF CRJ200 SRM 51-12-00. FOUND AREA TO BE OUT OF LIMIT. REPLACED FLAP VANE CAP AT RH INBOARD FLAP VANE OUTSDR SWIA202158731Attenuator · leakingCREW REPORTS IN CRUISE FLT, GOT HYD 2 LOW PRESS CAUTION MESSAGE. RAN QRH WHICH STATED TO CONTINUE UNLESS PRESSURE WAS LOST & HYD SYS 2 PRESSURE WAS LOST, WITH HYD PUMP 2B CAUTION & LOSS OF HYD SYS 2 FLUID QTY, NOW AT 5%. CREW DIVERTED TO MKE, EMERGENCY WAS DSDR SWIA2020031649317Door Sill · corrodedCORROSION FOUND ON CARGO DOOR SILL. (C-CHECK) RO 3/13/2020 REMOVED AND REPLACED CARGO DOOR SILL REF BOMBARDIER REO. LEAK CHECK GOOD.SDR SWIA2020031649320Retainer · crackedPASSENGER DOOR BOTTOM SEAL RETAINER IS CRACK. (C-CHECK) RO 3/13/2020 REMOVED AND INSTALLED NEW SERVICEABLE PASSENGER DOOR BOTTOM SEAL RETAINER P/N# 601R318722-1 REF BOMBARDIER DRAWING AND CRJ200 SRM.SDR SWIA2020031649316Attach Angle · corrodedPAX DOOR LOWER SILL ATTACH ANGLE (2EA) AT FS319.70 AND FS349 IS CORRODED. (C-CHECK) RO 3/13/2020 THE FWD AND AFT SILL ATTACH ANGLES, CLEATS, WERE FOUN TO BE OUT OF LIMITS. REMOVED AND REPLACED WITH NEW CLEATS AT PAX DOOR LOWER SILL FS319.70 & FS349 REF BOMSDR SWIA2020031649315Intercostal · corrodedINTERCOSTAL BETWEEN F.S 333 AND F.S 349 FRAMES AT STGR 21L IS CORRODED. (C-CHECK) RO 3/13/2020 REMOVED, FABRICATED, AND REPLACED INTERCOSTAL BETWEEN FS333.00 AND FS349.00 @ STGR 21L. REF BOMBARDIER DWG, CRJ200 SRM. COMPLIED WITHTASK CARD.SDR SWIA2020031649314Intercostal · corrodedINTERCOSTAL JUST FWD OF F.S 333 FRAME AT STGR 21L IS CORRODED. (C-CHECK) RO 3/13/2020 REMOVED, FABRICATED, AND REPLACED INTERCOSTAL BETWEEN FS310.00 AND FS333.00 @ STGR 21L. REF BOMBARDIER DWG, CRJ200 SRM. COMPLIED WITHTASK CARD.SDR SWIA2020031649319Web · corrodedPASSENGER DOOR FWD WEB IS CRACK AND CORRODED AT MULTIPLE AREAS. (C-CHECK) RO 3/13/2020 REMOVED AND INSTALLED NEW SERVICEABLE PASSENGER DOOR FWD WEB REF BOMBARDIER DRAWING SRM.SDR SWIA2020031649313Trunnion · wornLHS NEW TRUNNION REQUIRES INCORPORATION OF SB 601R-048 REV C DUE TO TRUNNION REPLACEMENT. (C-CHECK) RO 3/13/2020 REWORKED HOLES IN NEW LHS TRUNNION FITTING WEB PER REO.SDR SWIA2020031649323Skin · corrodedWHILE GETTING ACCESS TO PAX DOOR HINGE FOUND CORROSION ON INNER SKIN AT 4EA LOCATIONS BETWEEN TOP FLANGE OF INTERCOSTALS AND INNER SKIN MATING SURFACE. (C-CHECK) RO 3/13/2020 REMOVED AND INSTALLED NEW INNER SKIN ON THE PAX DOOR REF BOMBARDIER DWG, AND CRJ-SDR SWIA2020031649312Door Sill · corrodedPAX DOOR LOWER SILL ANGLE HAS MULTIPLE AREAS OF CORROSION (MARKED) (C-CHECK) RO 3/13/2020 REPLACED THE PAX DOOR LOWER SILL AT FS319.70 AND FS349 REF. BOMBARDIER DRAWING, CRJ200 SRM. COMPLIED WITH TASK CARD. OPERATIONAL CHECK GOOD.SDR SWIA2020031649311Door Frame · corrodedWHILE GETTTING ACCESS TO PAX DOOR HINGE FOUND CORROSION ON FWD FORMER FS311.75 BETWEEN INTERCOSTAL DD5 AND DD6. (C-CHECK) RO 3/13/2020 REMOVED AND REPLACED PAX DOOR FWD FORMERS AT FS311.75 REF BOMBARDIER DWG, CRJ-200 SRM. LEAK CHECK GOOD.SDR SWIA2020031649310Floorbeam · defectiveREPLACE LBL 9 FLOOR BEAM CAP BETWEEN FS559.00+80 TO FS569.00. (C-CHECK) RO 3/13/2020 PERFORMED SPLICE REPAIR OF LBL 9 FLOOR BEAM CAP BETWEEN FS559.00+80 TO FS569.00. REF CRJ200 SRM, BOMBARDIER REO. COMPLIED WITH TASK CARD.SDR SWIA2020031649309Reinforcement · corrodedFS 605 LOWER FRAME REINFORCING ANGLE HAS CORROSION ON MULTIPLE ELEMENTS AND MULTIPLE LOCATIONS AND HAS 1EA EXISTING OVERSIZED HOLE (C-CHECK) RO 3/13/2020 INSTALLED NEW REINFORCING ANGLE ON FRAME AT FS 605.00. REF BOMBARDIER DWG AND CRJ-200 SRM. COMPLIED WISDR SWIA2020031649308Doubler · corroded* RIGHT WING BATT RIB WS53.60 DOUBLER IS CORRODED. (MARKED) (C-CHECK) RO 3/13/2020 RECEIVED NEW DOUBLER (ANGLE) P/N 601R10203-34, ORDERED AND RECEIVED REPLACEMENT FASTENERS. REMOVED AND INSTALLED R/WING BATT RIB REPLACEMENT DOUBLER (ANGLE) WITH REPLACEMENTSDR SWIA2020031649307Skin Panel · chafedL/H APRON SKIN PANEL ASSY. IS CHAFFED COMMON TO THE L/H WING AFT TOP SKIN PANEL (C-CHECK) RO 3/13/2020 PERFORMED CUT AWAY OF DAMAGED PORTION AND REMOVED ALL BURRS & SHARP EDGES AT L/H APRON SKIN PANEL. FABRICATED & WET INSTALLED WITH NEW FASTENERS ALL L/H SDR SWIA2020031649306Floorbeam · corrodedFLOOR BEAM CAP AT LBL.27 HAS SIGHNS OF CORROSION AND GOUGING FROM FS.569-FS.610 (INBD AND OTBD FLANGES) (C-CHECK) RO 3/13/2020 REPLACED FLOOR BEAM CAP AT LBL27 . FS 569.00 TO FS 610.00 REF CRJ 200 SRM, BOMBARDIER DWG AND REO. SEE CONTINUE CARD FOR DETAILSDR SWIA2020031649305Floorbeam · corrodedFLOOR BEAM CAP AT LBL.27 HAS SIGHNS OF CORROSION AND GOUGING FROM FS.559+80-FS.569 (INBD AND OTBD FLANGES) (C-CHECK) RO 3/13/2020 FLOOR BEAM CAP AT LBL 27 REPAIRED FROM FS569 TO FS559+10 REF CRJ200 SRM AND BOMBARDIER REO. SEE CONTINUATION CARD FOR WORK DSDR SWIA2020031649304Hinge · damagedPAX DOOR HINGE ROLL PIN HOLE IS ELONGATED. (C-CHECK) RO 3/13/2020 REMOVED AND REPLACED PAX DOOR HINGE REF CRJ-200 SRM. LEAK CHECK GOOD.SDR SWIA2020031649303Fitting · damagedWHILE COMPLYING WITH SB (RHS) DEFECT NOTED IN HOLE #14, #15, #18, #19, #21 AND #22. (C-CHECK) RO 3/13/2020 PERFORMED A REPAIR ON RH TRUNNION HOLES WHILE COMPLYING WITH SB (RHS) DEFECT NOTED IN HOLE #14, #15, #18, #19, #21 AND #22. REF BOMBARDIER REO.SDR SWIA2020031649302Fitting · damagedWHILE COMPLYING WITH SB (LHS) DEFECT NOTED IN HOLE #17, #19 AND #20. (C-CHECK) RO 3/13/2020 REPLACED THE TRUNNION FITTING AND LOWER STEEL STRAP AT WS65.75 BETWEEN R/S & AUX SPAR, LHS PER REO, DWG'S AND BOMBARDIER R.I.L.. COMPLIED WITH SKYWEST TASKCARD.SDR SWIA2020031649301Frame · cracked*FS333.00 FRAME CRACKED APPROX STGR 0 €“ STRG 1LH (MARKED) (C-CHECK) RO 3/13/2020 REMOVED AND INSTALLED NEW SERIVCEABLE FRAME AT FS333.00 APPROX STGR 0 - STGR 1L. REF BOMBARDIER DRAWING CRJ200 SRM. PRESSURE LEAK CHECKS GOOD.SDR SWIA2020031649300Intercostal · corrodedINTERCOSTAL AT FS394.00 TO FS409.00, JUST LEFT OF STR27 HAS CORROSION. (C-CHECK) RO 3/13/2020 REMOVED AND INSTALLED NEW SERVICEABLE INTERCOSTAL LOCATED BETWEEN FS394.00 - FS409.00 AND COMMON TO STGR 27L. REF BOMBARDIER DRAWING AND CRJ200 SRM. PRESSURE LEAKSDR SWIA2020031649299Floorbeam · corrodedFS 409.00+112 TO FS 409.00+128 FLOOR BEAM AT RBL 9 HAS CORROSION ON INBD FLANGE AROUND NUTPLATES (C-CHECK) RO 3/13/2020 PERFORMED A REPAIR ON FS 409.00+112 TO FS 409.00+128 FLOOR BEAM AT RBL 9 HAS CORROSION ON INBD FLANGE AROUND NUTPLATES REF REO COMPLIED SDR SWIA2020031649298Floorbeam · corrodedFLOOR BEAM CAP FROM FS 409.00 TO FS 409.00+112 AT RBL 9 HAS CORROSION ON INBD FLANGE AND OTBD FLANGE (C-CHECK) RO 3/13/2020 REMOVED AND INSTALLED NEW FLOOR BEAM CAP SECTION AT RBL 9 BETWEEN FS409.00-FS409+112. REF BOMBARDIER REO, BOMBARDIER DWG, CRJ200 SRMSDR SWIA2020031649297Beam · crackedFS 409.00+128 BULKHEAD BEAM BL 27L/H LOWER INBOARD SIDE HAS A POSSIBLE CRACK GOING UP FROM BOTTOM AS MARKED. (C-CHECK) RO 3/13/2020 REMOVED AND INSTALLED NEW F.S 409+128 BULKHEAD BEAM/POST AT LBL 27 REF. BOMBARDIER REO. COMPLIED WITH TASK CARD. PRESSURE
Back to N461SW