N469UP
Service difficulty reports · 208
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N469UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N469UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA3580173Floor Panel · delaminatedDURING C-8, MAIN CABIN FLOOR PANEL 242XFF DELAMINATED AND HAS EDGE DAMAGE FABRICATED NEW FLOOR PANEL IAW B757-5320-9692-H.SDR IPXA3580142Floor Panel · damagedDURING C-8 INSPECTION, MAIN CABIN FLOOR PANEL 252XTF HAS EXCESSIVE EDGE DAMAGE. FABRICATED NEW FLOORBOARD IAW SREO B757-5320-9692-H.SDR IPXA3580122Floor Panel · damagedDURING C-8 INSPECTION, MAIN CABIN FLOOR PANEL 231XSF DAMAGED ON BOTTOM. FABRICATED NEW FLOOR PANEL IAW SREO B757-5320-9692-H.SDR IPXA3578046Skin · damagedLIGHTNING STRIKE DAMAGE TO RT ELEVATOR T/E. REPAIRED IAW EO B757-5520-50405-B.SDR IPXA3578026Skin · dentedDOOR DENTED OUTER SKIN. REPAIRED IAW EO B757-5320-50569-A.SDR IPXA13577941Skin · damagedLIGHTNING STRIKE DAMAGE AT BS 1671, STR 14. REPAIR IAW EO B757-5330-50508-A.SDR IPXA13577939Skin · damagedLIGHTNING STRIKE DAMAGE AT BS 1708. REPAIRED IAW EO B757-5330-50509-A.SDR IPXA1569550Support Angle · corrodedINSPECTION TYPE:C-CK, SUPPORT ANGLES CORRODED AT APU INLET DUCT STA 1787, S6R. R & R SUPPORT ANGLE IAW DWG 148N3152.SDR IPXA1569480Cargo Fitting · corrodedINSPECTION TYPE:C-CK, AFT CARGO COMPARTMENT STA 1360 LBL 23 "Z" ANGLE TIE-DOWN FITTING HAS CORROSION. REPLACED FITTING IAW SRM 51-40-02.SDR IPXA1569478Frame · dentedINSPECTION TYPE:C-CK, FORWARD CARGO COMPARTMENT BS 660 AND STR 24-R FRAME DENTED ON INBD FLANGE. REPAIRED BS 660 FRAME AT STR 24R IAW EO B757-5310-44513-A.SDR IPXA1569472Cargo Track · corrodedINSPECTION TYPE:C-CK, AFT CARGO COMPARTMENT STA 1375, LBL 23 "Z" ANGLE TIE-DOWN CROWN FITTING HAS CORROSION. REPLACED CROWN FITTING IAW SRM 51-40-02.SDR IPXA1569467Panel · corrodedINSPECTION TYPE: C, MAIN CARGO COMPARTMENT RT AFT AIR GRILL LOWER MOUNT PANEL HAS CORROSION AT FWD END. REMOVED CORROSION IAW EA 111248 IR AND EO B757-5320-44481-A.SDR IPXA1569466Cargo Fitting · corrodedINSPECTION TYPE: C, AFT CARGO COMPARTMENT STA 1360 RBL 23 "Z" ANGLE TIE-DOWN FITTING HAS CORROSION. REPLACED FITTING IAW SRM 51-40-02, DWG 146N5440, EA 111263 IR, EO B757-5320-44474-A.SDR IPXA1569465Cargo Track · corrodedINSPECTION TYPE: C, AFT CARGO COMPARTMENT STA 1340, RBL 22 "Z" ANGLE TIE-DOWN FITTING HAS CORROSION. REPLACED FITTING IAW SRM 51-40-02, DWG 146N5440.SDR IPXA1569551Angle · corrodedINSPECTION TYPE:C-CK, APU INTAKE AIR DOOR HOUSING SURROUND STRUCTURE AT 1787-1825 S6, INBD AND AFT ANGLES HAVE CORROSION. REPAIRED SURROUND STRUCTURE AT APU INTAKE HOUSING IAW EA 111314, REV IR.SDR IPXA1569408Floorboard · damagedINSPECTION TYPE:C-CHECK, FLOORBOARD 251 XRF IS DAMAGED ON THE CORNER. FABRICATED NEW FLOORBOARD IAW EO B757-5320-9692-G.SDR IPXA1569370Frame · dentedINSPECTION TYPE:C-CHECK, FORWARD CARGO PIT AT BODY STA 760 BETWEEN STR 23L AND 24L FUSELAGE FRAME INBD FLANGE HAS DENT. REMOVED DAMAGE. FABRICATED AND INSTALLED REPAIR IAW SRM 53-00-07-2R5.SDR IPXA11569447Frame · dentedINSPECTION TYPE: C, FORWARD CARGO BAY AT BODY STA 820 AND BETWEEN STR 23L AND 24L, FUSELAGE FRAME INBD FLANGE HAS DENT. REMOVED DAMAGE AND REPAIRED IAW SRM 53-00-07-2R5. FABRICATED REPAIR ANGLE AND HEAT TREATED TO T6 IAW SRM 53-00-07-2R5 DETAIL II. ORIGINALSDR IPXA1569368Frame · dentedINSPECTION TYPE:C-CK, FORWARD CARGO PIT AT BODY STA 800 AND BETWEEN STR 22R AND 23R , FUSELAGE FRAME INBD FLANGE HAS DENT. REMOVED DAMAGE AND REPAIRED STA 800 FRAME BETWEEN STR 22R AND 23R IAW SRM 53-00-07-2R5 FABRICATED -1 REPAIR ANGLE FROM 7075-0 .071 AND HSDR IPXA1569367Frame · dentedINSPECTION TYPE:C-CHECK, FORWARD CARGO PIT AT BODY STA 680 FRAME AND BETWEEN STRINGER 25R A ND 24R, FUSELAGE FRAME INBD FLANGE HAS DENT. REMOVED DAMAGE AND REPAIRED STA 680 FRAME BETWEEN STR 25R AND 24R IAW SRM 53-00-07-2R5. FABRICATED-3 REPAIR ANGLE FROM 707SDR IPXA1568428Fire Detector · false activationRT ENGINE FIRE IN FLT QRH PROCEDURES FOLLOWED, ENG SHUTDOWN. AC OOS. FIRE BOTTLES 1 & 2 DISCHARGED. R & R ENGINE FIRE BOTTLE NR 1 AND NR 2 IAW AMM 26-21-01-4. TESTS SATISFACTORY. INSPECTED RT ENGINE FOR SIGNS OF FIRE OR OVERHEAT AND NO DAMAGE FOUND. ACCOMSDR IPXA11568428Engine · fireRT ENGINE FIRE IN FLT, QRH PROCEDURES FOLLOWED, ENG SHUTDOWN. ACFT OOS.SDR IPXA09557522Frame · dentedINSPECTION TYPE:C2 BS 1300 FRAME DENTED AT STR 26R. REPAIRED DENTED AREA IAW SRM 53-00-07-1A AND ER 09-4632.SDR IPXA09557455Panel · corrodedINSPECTION TYPE:C2 SIDE PANEL CORRODED, BS 520, LBL 19, WL 156. REMOVED, FABRICATED, AND INSTALLED PER SRM 51-40-02.SDR IPXA09557454Floor Panel · corrodedINSPECTION TYPE:C2 CORROSION ON NR 3 FLOOR PANEL IN FWD CARGO BAY. REMOVED, FABRICATED, AND INSTALLED PER SRM 53-00-53.SDR IPXA09557445Attach Fitting · corrodedINSPECTION TYPE:C2 FWD CARGO BAY DOOR CUTOUT LOWER THRESHOLD ATTACH FITTING STATION 607 LOWER AFT FASTENER MOUNT HOLE IS CORRODED. REMOVED AND REPLACED PER SRM 51-40-02-0G.SDR IPXA09557444Attach Fitting · corrodedINSPECTION TYPE:C2 FWD CARGO BAY DOOR CUTOUT: LOWER THRESHOLD ATTACH FITTING STATION 574 LOWER FWD FASTENER MOUNT HOLE IS CORRODED. REMOVED AND REPLACED FITTING.SDR IPXA09557442Frame · dentedINSPECTION TYPE:C2 BS 1240 FRAME DENTED AT STR 25L. REPAIRED REV ATS ER 09-4631.SDR IPXA09557433Flap · damagedINSPECTION TYPE:C2 RT OUTBOARD AFT FLAP TRAILING EDGE TIP HAS FIBER DAMAGE AT OUTBOARD FLAP TRACK FAIRING. REMOVED DAMAGE & REPAIRED PER SRM 57-53-01-0I-1 FIG 2 SHEETS 1-10&13 & DETAIL VII ITEM.SDR IPXA09557428Floor Panel · corrodedINSPECTION TYPE:C2 FWD CARGO NR 4 FLOOR PNL HAS AREAS OF CORROSION ON UPPER SURFACE AT MBA SYS CONTACT POINTS. FABRICATED REPLACEMENT FCB NR 4 FLOOR PANEL IAW SRM 51-40-05-0G.SDR IPXA09557463Floor Support · corrodedINSPECTION TYPE:C-2 MAIN CARGO COMPARTMENT BS 1020, BL 0 - RBL 25, FLOOR SUPPORT IS CORRODED AT FASTENER HOLES. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT FLOOR SUPPORT IAW DWG 144N5005 AND SRM 51-40-02-0G.SDR IPXA09557435Bracket · crackedINSPECTION TYPE:C2 FWD CARGO BAY CEILING PANEL TO FLOORBEAM ATTACH BRACKET IS CRACKED BS 520 BL 0, WL 200. REMOVED, FABRICATED AND INSTALLED BRACKET PER SRM 51-30-01-0G AND DWG 453N1858.SDR IPXA09557531Floorbeam · corrodedINSPECTION TYPE:C-2 MAIN CABIN, 1100 FLOORBEAM UPPER T-CHORD, LBL 65 TO RBL 65 IS CORRODED IN NUMEROUS AREAS. REPAIR PER ATS ER 09-4596.SDR IPXA09557530Floorbeam · corrodedINSPECTION TYPE:C-2 MAIN CABIN, 1200 FLOORBEAM UPPER T-CHORD, LBL 10 IS CORRODED. REPAIRED PER ATS ER 09-4583.SDR IPXA09557529Floorbeam · corrodedINSPECTION TYPE:C-2 MAIN CABIN, 1200 FLOORBEAM UPPER CHORD, RBL 45 - RBL 65 HAS CORROSION ON UPPER AND LOWER SURFACE. REPAIRED PER ATS ER 09-4538.SDR IPXA09557526Skin Panel · crackedINSPECTION TYPE:C2 RT WING FSS 440 FIXED LOADING EDGE 6 INCHES CRACK IN FIBER. ACCOMPLISHED WORK EO B757 5740-11855-D APPENDIX B.SDR IPXA09557519Wedge · debondedINSPECTION TYPE:C2 LT WING L/E NR 4 SLAT HAS DISBOND ON UPPER SURFACE T/E WEDGE 50.5 FROM O/B END 7 INCHES FROM T/E. REMOVED AND REPLACED NR 4 SLAT ASSY IAW MM 27-81-02-4.SDR IPXA09557509Seat Track · corrodedINSPECTION TYPE:C2 MAIN CABIN RBL 45, BS 1180 - BS 1200 SEAT TRACK FLANGE HAS CORROSION AT FASTENER HOLES. REMOVED CORROSION, VERIFIED NO CRACKS EXIST, FILLED DIVIT, APPLIED CPC.SDR IPXA09557508Seat Track · corrodedINSPECTION TYPE:C2 MAIN CABIN RBL 25, BS 1180 - BS 1200, SEAT TRACK FLANGE HAS CORROSION AT FASTEN HOLES. REPAIRED SEAT TRACK FLANGE IAW ER 09-4627.SDR IPXA09557467Floor Panel · corrodedINSPECTION TYPE:C2 AFT/BULK CARGO COMPARTMENT NR 2 FLOOR PANEL HAS EXCESSIVE CORROSION UNDERNEATH THE MBA SYSTEM. FLOOR PANEL OUT OF LIMITS, FABRICATED NEW FLOOR PANEL PER SRM 53-00-53-1A, SRM 51-40-05-06.SDR IPXA09557462Floor Support · corrodedINSPECTION TYPE:C-2 MAIN CABIN, BL 0 - LBL 25, BS 1050, FLOOR SUPPORT HAS CORROSION AT FASTENER HOLES. REMOVED, FABRICATED, AND INSTALLED REPLACEMENT FLOOR SUPPORT IAW DWG 144N5005 AND SRM 51-40-02-0G.SDR IPXA09557461Floor Panel · corrodedINSPECTION TYPE:C2 AFT CARGO BAY NR 4 FLOOR PANEL IS CORRODED. REMOVED, FABRICATED, AND INSTALLED FLOOR PANEL PER SRM 51-20-05 AND SRM 51-40-08.SDR IPXA09557456Beam · corrodedINSPECTION TYPE:C2 LONGITUDINAL BEAM CORRODED, BS 1040 TO 1076, LBL 24, WL 208. REMOVED, FABRICATED, AND INSTALLED PER SRM 51-40-02, AND DWG 144N8017.SDR IPXA09557434Skin Panel · crackedINSPECTION TYPE:C2 LEFT O/B MAIN FLAP LOWER SURFACE HAS POSSIBLE CRACK 11 INCHES FROM AFT AND 2 INCHES FROM O/B END. REPAIRED MAIN FLAP PER 757-200 PR SRM 57-53-01-2R-4.SDR IPXA09557408Floor Panel · corrodedINSPECTION TYPE:C2 AFT CARGO BAY NR 1 FLOOR PANEL IS EXCESSIVELY CORRODED UNDERNEATH THE MBA SYSTEM. FABRICATION NEW FLOOR PANEL AND INSTALLED IAW SRM 53-00-53-1A AND MM25-50-04-4.SDR IPXA09557400Floor Panel · damagedINSPECTION TYPE:C2 MAIN CARGO COMPARTMENT FLOOR PANEL AT BS 900-1020 RBL 45-65 HAS A PREVIOUS INSTALLED REPAIR AT BS 974, RBL 54. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692 APPENDIX B.SDR IPXA09557399Floor Panel · damagedINSPECTION TYPE:C2 MAIN CARGO COMPARTMENT FLOOR PANEL AT BS 1056 - 1100, BL 0 - LBL 25 HAS A PREVIOUS INSTALLED REPAIR AT BS 1058, LBL 6. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692G APPENDIX B.SDR IPXA09557518Ramp · gougedINSPECTION TYPE:C2 NR 1 ENGINE LEFT T/R OUTER BARREL AFT I/B STRUCTURE GOUGED. REMOVED AND REPLACED GOUGED NR 1 ENGINE LEFT T/R AFT I/B RAMP IAW SRM 51-40-02-0G.SDR IPXA09557441Frame · damagedINSPECTION TYPE:C2 FUSELAGE FRAME AND FAILSAFE CHORD TEMP REPAIRED AT BS 1640 BETWEEN STR 25L AND 26L. REPAIRED PER ATS ER 09-4547.SDR IPXA09556639Frame · damagedINSPECTION TYPE:N/A FRAME DAMAGE AT STA 1640 BETWEEN STR 21 & 22R. REPAIRED PER EO B757-5310-34149-A.
Back to N469UP