N484UA
Service difficulty reports · 91
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N484UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N484UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2014040890781Skin · saturatedLEFT ELEVATOR UPPER SKIN SURFACE AREA HAS A WATER INGRESS INDICATION 35 - 43 FROM INBD END, 6 INCHES FROM TE, 7.75 X 5 INCHES DIAMETER. REPAIRED LT ELEVATOR UPPER SKIN AT LOCATION NOTED. DRILLED WITNESS HOLES & FOUND NO EVIDENCE OF WATER. APPLIED REPAIR IAWSDR CALA2013102892416Sill · corrodedR2 DOOR SILL HAS CORROSION. REPLACED R2 DOOR SILL IAW SRM 51-42-11 ON TIMCO NR 43035.SDR CALA2013102892415Threshold · corrodedCORROSION L2 DOOR THRESHOLD INBD OF AFT GIRT BAR LOCK. BLENDED CORROSION ON L2 DOOR THRESHOLD INBD OF AFT GIRT BAR LOCK FRAME 68 STRINGER 23L OUT OF LIMITS IAW SRM 53-41-14. REMOVED, FABRICATED & INSTALLED REPAIR PARTS IAW SRM 53-41-14.SDR CALA2013100391687Unknown · odorODOR IN COCKPIT RETURNED AFTER PACKS CAME ON. ODOR SMELLS LIKE ROTTING FOOD. PERFORMED AIR CONDITIONING OPERATIONAL TEST RUNNING APU ONLY, NO SMELLS NOTED. PERFORMED ENGINE RUN ON BOTH ENGINES, RUN PACKS WITH ENGINES ONLY. NO SMELL CAN BE DUPLICATED AT THIS SDR CALA2013090591060Seat Belt · defectiveSEAT 37D NEEDS NEW CUSHION & SEAT BELT. CLEANED SEAT CUSHION & REPLACED ONE SET OF SEAT BELTS FOR SEAT 37D.SDR CALA2013083090859Nut Plate · brokenFASTENER MISSING ON RT PANEL 191KB OUTBOARD EDGE FOURTH FASTENER FROM FORWARD CORNER. CORRECTION LT PANEL 191KB NUTPLATE FOUND BROKEN. CERTIFIED FOR 10 CYCLES. REPLACED MISSING FASTENER IAW IPC 53-35-03.SDR CALA2013081990526Nose Cowl · crackedNR 1 ENGINE NOSE COWL INNER SKIN AT 4 O'CLOCK POSITION HAS A CRACK INDICATION. LENGTH OF CRACK 0.300" AND TERMINATES INTO FASTENER HOLE.SDR UALA2013042202775Transformer · defectiveCOCKPIT AUDIO CONTROL PANEL 1 INOPERATIVE. TROUBLESHOT PROBLEM TO 35 LP TRANSFORMER. REPLACED AND OPS CHECKED NORMAL.SDR UALA2013030701356Circuit Breaker · trippedNR 2 CABIN ENTRY LIGHT CIRCUIT BREAKER TRIPPED. RESET, TESTED CIDS. NO FAULT NOTED.SDR UALA2013012200385Skin · degradedLEFT L/E SLAT REPAIR DEGRADED. REPLACED NR 1 LEFT SLAT PER MM, OPS CHECKED GOOD.SDR UALA2013010900157Connector · damagedSEAT 35 ABC EPL LIGHT INOPERATIVE. FOUND WIRING BROKEN AT CONNECTOR. REPAIRED WITH NEW CONNECTOR PER ESPM 25-53-55. OPS OK AT THIS TIME.- ACCOMPLISHED IDT INSPECTION AS REQUIRED.SDR UALA2012081304474Unknown · odorFLIGHT ATTENDANTS REPORTED ELECTRICAL ODOR AROUND ROW 20. SHUTOFF GALLEY AND CABIN. OPERATED LL SYSTEM THROUGHOUT CABIN INCLUDING PACKS AND EMERGENCY LIGHTING. COULD NOT DUPLICATE. NO ODOR ON ARRIVAL.SDR UALA2012071103712Battery Pack · failedEMERGENCY LIGHT TEST HAS FAILED MESSAGE EPSU BATTERY FWD LT. REPLACED BATTERY PACK.SDR UALA2012041502276Conduit · unsecureCREW REPORT: STILL HAVE OCCASIONAL LOUD HUMMING IN FWD GALLEY ONCE PRIOR TO LEVEL OFF AND JUST AFTER DESCENT. OPENED CEILING PANELS IN FWD GALLEY FOUND ENTRY LIGHT CONDUITS NOT SECURED, SECURED CONDUITS. NO OTHER DEFECTS FOUND. REINSTALLED PANELS.SDR UALA2013010900156Battery · failedCABIN EMERGENCY LIGHTS TEST FAILED. REPLACED EPSU BATTERY AT 10WL POSITION ACP'D OP TEST PER AMM, OKAY.SDR UALA2011112106390Wire Harness · faultyTHE 21ABC EEL LIGHT INOP. REPAIRED SEAT HARNESS AND LIGHT CHECKED OK. FOUND BROKEN WIRE ON SEAT HARNESS TO LIGHT SOCKET HARNESS. NEEDS EITHER A NEW HARNESS OR TO BE RE-PINNED. COMPLIED WITH MEL. ALL ADJ LIGHTS OPERATE NORMALLY. PLZ ID PARTS NEEDED AND IPSDR UALA2011082404531Strut · defectiveFOUND NOSE STRUT FLAT ON WALK AROUND. SERVICED WITH NITRO. TO BE RECHECKED WITHIN 4 TO 7 DAYS. SERVICED NOSE STRUT PER AMM. NOW NEED TO BE RECHECKED 4-7 DAYS. TIME CHANGED TO 22AUG PER SAMC CONTROLLER. REMOVED NLG STRUT INNER CYLINDER AND REPACK SHOCK ABSSDR UALA2011072203717Valve · faultedHIGH COCKPIT-FWD-AFT TEMP SWITCH, FULL COLD SELECTED. NO CHANGE WITH TRIM ON OR OFF. REMOVED ACCESS PANEL FOR HOT AIR VALVE DEF NEW VALVE AND SCREWS IN FWD PIT. REPLACED HOT AIR VALVE REF MM, VLV 14HK.SDR UALA2011072003694Valve · faultyCOCKPIT AND FWD CABIN DIFFICULT TO CONTROL TEMP. COCKPIT HOT 82-84. FWD CAB 76-78 BOTH FULL COLD. REPLACED PRESSURE REGULATOR VALVE MR21634 AND COCKPIT TRIM VALVE 11HK PER MM. OPS CHECK NORMAL IN COLD AND HOT AIR.SDR UALA2011070503297Acoustic Liner · tornCREW REPORT: NR 1 ENGINE HAS A 1 1-2 TEAR IN ACOUSTIC LINING AT THE APPROX 4 O'CLOCK POSITION. SAMC TEXT: LCL CO MAINT REPORTS: ENG1 INLET COWL (NOSE COWL) WIRE MESH HAS A TEAR APPROX.1.250 INCHES AT 7 O'CLOCK. DAMAGE IS WITHIN CARRY FORWARD LIMIT OF MT71-0SDR UALA2011052402532Window · leakingF/O WINDSHIELD NOISE. PRESSURE LEAKS FOUND ALL UPPER RIVETS ON F/O WINDSHIELD. CUT OUT DEPRESS STARTED APPLYING FIRST LAYER RESIN REF LM8573. REMOVE WINDSHIELD & CHECKED THE WINDSHIELD FRAME SPOT FACINGS ARE PROPERLY FILLED WITH SEALANT. INSTALLED WINDSHIESDR UALA2011051002310Controller · faultyCAPT FWD WINDSHIELD COLD, APPEARS INOP. REMOVED AND REPLACED NR 2 WINDOW HEAT CONTROLLER FROM AC 4712 AND PLACED IN AC 4284. PART INSTALLED SN1045 MR30409. OK FOR SERVICE.SDR UALA2010110104063Battery Pack · dischargedACCOMPLISHED CIDS TEST RT EMERGENCY POWER SUPPLY UNIT BATTERY FAILED. REPLACED BATTERY WITH NEW CHARGED BATTERY. OPS CHECK GOOD CIDS TEST PASSED.SDR UALA2010072202622Idg · faultyELEC SYS ISSUE, RTFL. WHILE ACCOMPLISHING EG4522 FOUND UNDER TORQUED SENSOR LEADS ON PHASE A & C AT BOTTOM OF GEN 1 CONT MODULE. THIS WAS NOT PART OF GLC 1 INSTALLATION. REMOVED WIRES AND INSPECTED, NO CORROSION OR ARCING FOUND. CLEANED TERMINALS AND RE-INSDR UALA2010071302513Terminal Block · burnedFOUND BURNED AND LOOSE CONNECTION ON CTR CONDUCTOR AT 1999VT IN AFT LT CEILING OF FWD PIT. REPLACED 1999VT TERM BLOCK AND SECURED NR1 & NR3 LUGS. MADE ENOUGH SLACK TO CLIMP ON NR2 LUG 56 1-YV200, AND THE AFT SIDE 2EA 6GA LUGS NEEDS REPLACED AND WIRE SPLICED ISDR UALA2010041301253Valve · openNO WATER PRESSURE ON ACFT AFTER TAKE-OFF. FOUND TANK OVERFLOW VALVE IN THE OPEN POSITION. CLOSED VALVE. OPS CKS OK. IAW LM, WATER OVERFLOW VALVE TO BE REPLACED. REPLACED WATER OVERFLOW VALVE. OPS ARE GOOD.SDR UALA2010012000248Unknown · odorIAW CREW AT START OF DESCENT AN ODOR WAS DETECTED WHEN CROSS BLEED VALVE WAS OPENED. UNABLE TO DUPLICATE ON GROUND, ODOR GONE. ENTERED INTO HIS.SDR UALA2009110903485Sensor · faultyUNABLE TO RETRACT L/G, RTFL. REPLACED NOSE GEAR SENSOR 25GA. FOUND BAD CONTINUITY. TESTED AIRCRAFT WITH NOSE GEAR SWING. NO FAULTS WERE NOTED.SDR UALA2009050801318Ball Seat · leakingLOW BOTTLE PRESSURE. SMALL LEAK COMING OUT OF OUTLET PORT. REMOVED & REPLACED BALL SEAT.SDR 2008UALA04323Power Supply · failedFAILURE OF THE EMERGENCY LIGHT TEST. *S/D* REPLACED POWER SUPPLY.SDR 2008UALA01682Mask · leakingFIRST OBSERVERS O2 MASK IS LEAKING. SUPPLEMENTAL DATA UPDATE CAUSE, MASK LEAKING AT PORT. REPLACED F OBS MASK. OPS CHECKED OK.SDR 2008UALA00125Pressure Switch · failedHYD RAT UPPER ECAM, LOWER ECAM HYD PAGE SHOWS RAT IN AMBER. FAULT IS CLEAR BUT HAS MANY HITS. RAT PRESSURE SWITCH FAILURE. REPLACED RAT PRESSURE SWITCH.SDR 2007UALA04255Seat Track · wornLEFT INBOARD, RIGHT INBOARD AND RIGHT OUTBOARD SEAT TRACKS BETWEEN FR 42 AND FR 47 HAVE WEAR AT LUGS WHERE FWD SEAT LEGS LOCK INTO TRACKS. REPLACED SEAT TRACK BETWEEN FR 42 AND FR 47. MAJOR REPAIR AT HMV.SDR 2007UALA01911Circuit Breaker · faultyFOUND CABIN EMERGENCY LIGHT TEST FAILS. [07-03-07] RESET CIDS, CYCLED EMERGENCY LIGHT BREAKERS. CABIN EMERGENCY LIGHT TEST PASSED.SDR 2007UALA01256Battery · faultyEMERGENCY LIGHT TEST FAILING EPSU BATTERY EMERGENCY L. RESET OPS CHECKS GOOD.SDR 2007UALA01122Battery Pack · failedEMERGENCY LIGHT CHECK FAILED DOOR 1L. [SUP 5-1-07] REPLACED BATTERY PACK AND EPSU. SYSTEM CHECKS NORMAL AT THE GATE.SDR 2007UALA00151Light · no testFAILED CABIN EMERGENCY LIGHTS TEST. EMERGENCY LIGHTS OPERATION CHECKED GOOD.SDR 2006UALA02409Unknown · odorBURNING ELECTRICAL SMELL REPORTED NEAR AFT GALLEY AREA.SDR 2006UALA02080Starter · failedRTBL DUE TO NR 1 ENGINE HUNG START, RAMP REPORTS SPARKS FROM STARTER AREA DURING 2ND START ATTEMPT, START CYCLE TERMINATED. INSPECTED AREA SURROUNDING STARTER & START VALVE, REPLACE STARTER AND START VALVE. OPS CHECKED GOOD.SDR 2006UALA00062Light · inoperativeEMERGENCY LIGHTS EEL LT SIDE 5 ROWS OF SEATS.SDR 2005UALA00794Hydraulic System · leakingFLIGHT EXPERIENCED GREEN HYD QTY LOSS AND ECAM INDICATION.
Back to N484UA