N516AS
Service difficulty reports · 400
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N516AS' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N516AS' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASAA2015042111639Block · bentR2 DOOR EMERGENCY ESCAPE SLIDE LATCH BLOCK ASSEMBLY PIN IS BENT. ACFT GROUNDED. R & R ESCAPE SLIDE LATCH BLOCK ASSY REF AMM 25-66-01 AND SRM 51-40-02 AND DWG 69-70843, REV D OPS CHECK OK, TOOL T8359Y CALIBRATED, DUE DATE 07-18-15.SDR ASAA2015042111553Clevis · bentL 2 DOOR EMERGENCY ESCAPE SLIDE LATCH BLOCK ASSEMBLY CLEVIS IS BENT. ACFT GROUNDED. REPLACED CLEVIS, REF SRM 51-40-02 AND PERFORMED FORCE CHECK REF AMM 25-66-01. FORCE CHECK WITHIN LIMITS. DOT REMOVED. TOOL ATTACHED.SDR ASAA2015041911414Warning Message · false activationAFTER PUSHBACK FMC DISAGREE DISPLAYED. ACFT GROUNDED. ACCOMPLISHED QRH. OPS NORMAL.SDR ASAA2015032211069Cone · wornREF T/C 78472000, NR 1 ENGINE FRONT SPINNER CONE BLACK ANODIZED COATING WORN 50 PERCENT OR GREATER. ACFT GROUNDED. R & R NR 1 ENGINE FRONT SPINNER CONE REF MM 72-21-01-400-801-F00.SDR ASAA2015031410959Warning Message · false activationAFTER PUSH BACK GOT "FMC DISAGREE" MESSAGE. ACFT GROUNDED. RAN ON GROUND CHECK LIST. MESSAGE DID NOT RETURN. REPROGRAMMED FMC. DEPARTED.SDR ASAA2015031210962Engine · making metalWHILE ACCOMPLISHING T/C 78472040, FOUND UNIDENTIFIABLE NON-MAGNETIC PARTICLES LARGER THAN .4" IN FWD SUMP SCAVENGE SCREEN MCD ON NR 2 ENGINE. MM 79-00-00-210-010, STEP 8 NEEDS TO BE ACCOMPLISHED. ACFT GROUNDED. ACCOMPLISHED STEP H8-10. NO ADDITIONAL NR 2 SDR ASAA2015031110919Warning Message · false activation"FMC DISAGREE" ILLUMINATED ON GROUND. ACFT GROUNDED. FOLLOWED QRH PROCEDURE, DID NOT REAPPEAR.SDR ASAA2015030910896Warning Light · false activationAFTER ENGINE START ZONE TEMP LIGHT ILLUMINATED FWD CAB. ACFT GROUNDED. PERFORMED BITE TEST OF NR 1 & NR 2 TEMP CONTROLLER, CLEARED FAULT- NO DEFECTS NOTED. ZONE TEMP LT EXTINGUISHED.SDR ASAA2015011910292Warning Message · false activationON RECALL, FORWARD CABIN ZONE TEMP ILLUMINATED. ACFT GROUNDED. NR 2 TEMP CONT LOGGED ZONE TRIM VALVE, BITE TEST GOOD, FAULT RESET.SDR ASAA2014120709893Battery Pack · inoperativeFOUND THE EXTERIOR LIGHTS ON THE AFT LT AFT OVERWING EXIT, LT AFT WING TO BODY FAIRING, AND AFT LT SERVICE DOOR WENT OUT EARLY. ACFT GROUNDED. REPLACED EMERGENCY BATTERY PACKS REF WDM 33-51-13. OPS CK GOOD.SDR ASAA2014120509873Warning Message · false activationFMC DISAGREE ON GROUND. ACFT GROUNDED. QRH ACCOMPLISHED, NORMAL OPS RESTORED.SDR ASAA2014120109837Warning Light · false activationON RECALL: FWD CABIN "ZONE TEMP" LIGHT ON, EXTINGUISHED WITH MASTER CAUTION RESET. ACFT GROUNDED. TROUBLESHOT IAW FIM 21-62, TASK 834. APPEARS TO HAVE BEEN AN INTERMITTENT FAULT. VERIFICATION TEST NORMAL. CONTROLLER FAULT CLEARED. HAS NO OTHER RECENT HISTORSDR ASAA2014102409466Tube · disconnectedCLIMBING THROUGH 14000 MASTER CAUTION AND RT PACK LIGHT ILLUMINATED. QRH PROCEDURES FOLLOWED RESET ATTEMPTED BUT NOT SUCCESSFUL. DIVERTED FOR LANDING. ACFT GROUNDED. R & R RT PACK TEMP SENSOR IAW MM 21-51-52-400-801. ACCOMPLISHED PACK ZONE TEMP CONTROLLER SDR ASAA2014102209456A/C Pack · unknownRIGHT PACK TRIPPED SHORTLY AFTER TAKEOFF. COMPLETED QRH COULD NOT RESET. ACFT GROUNDED. PERFORMED FIM 21-62 TASK 801. BITE CHECK ON BOTH PACK/ZONE TEMP CONTROLLERS. NO FAULTS FOUND. PERFORMED FIM 21-53 TASK 818 INSPECTED RAM AIR INLET AND FOUND NO BLOCKASDR ASAA2014101809417Warning Message · false activationFMC DISAGREE AFTER ENGINE START. ACFT GROUNDED. COMPLETED FMC DISAGREE CHECKLIST WITH FULL RESOLUTION OF FMC DISAGREE.SDR ASAA2014101309377Fireshield · crackedNR 2 ENGINE AFT FLANGE, FIRE SHIELD, HAS NUMEROUS CRACKED BOLT HOLES. ACFT GROUNDED. REPLACED OIL INLET COVER, REF MM 72-56-00.SDR ASAA2014092709228A/C Pack · malfunctionedRT PACK LIGHT ILLUMINATE AND WILL NOT EXTINGUISH. ACFT GROUNDED. REPLACED RT PACK COMPRESSOR DISCHARGE, TURBINE INLET, AND PACK DISCHARGE OVERHEAT SWITCHES. OPERATED PACKS BETWEEN FULL COLD AND FULL WARM NO PACK LIGHT. OPS NORMAL.SDR ASAA2014092609227Warning Light · false activationRIGHT PACK LIGHT ON. COULD NOT RESET. ACFT GROUNDED. ACCOMPLISHED PACK ZONE TEMP. CONTINUE BITE, RT SIDE IAW FIM 21-62, TASK 801. NO FAULTS AND ACCOMPLISHED GROUND VERIFICATION IAW AMM 21-61-00. NO RT PACK LIGHT ON, NOTED. OPS CHECKED NORMAL.SDR ASAA2014092509226Plenum · dirtyRIGHT PACK LIGHT ILLUMINATED DURING CLIMBOUT PASSING 18,000FT. RESET OK. ACFT GROUNDED. ACCOMPLISHED PACK\ZONE TEMP CONTROLLER BITE PROCEDURE REF AMM 21-62, TASK 801. NO FAULTS SOUND. ACCOMPLISHED FIM 21-53-806, NO DEFECTS FOUND. ACCOMPLISHED RT HEAT EXCSDR ASAA2014092509225Control Valve · malfunctionedDURING CLIMBOUT THROUGH 18,000 FT, RT PACK LIGHT ILLUMINATED, RAN QRH, LIGHT RESET AND ILLUMINATED AGAIN. ACFT GROUNDED. PERFORMED RT PACK ZONE TEMP BITE VARIOUS TIMES IN VERIFY FOUND RT TEMP CONTROL VALVE FAULTED. REF FIM 21-62, TASK 801. REPLACED RT PACSDR ASAA2014090109026Warning Light · illuminatedDURING CLIMB, APPROX 14000 FT, 5.6 PSI DIFFERENTAL PRESSURE, RIGHT PACK LIGHT ILLUMINATED. FOLLOWED QRH AND RESET PACK. PACK AGAIN TRIPPED APPROX 2 MINUTES LATER. ACFT GROUNDED. PERFORMED BITE CHECK IAW FIM 21-62-801 & FIM TASK 21-53-818. RIGHT PACK LIGHTSDR ASAA2014082408942Control Valve · malfunctionedLEFT PACK LIGHT ILLUMINATED DURING RECALL. ACFT GROUNDED. SYSTEM STILL HAS A HARD FAULT FOR NR 1 TCV. REPLACED NR 1 TCV IAW AMM 21-51-10-000-801 AND AMM 21-51-10-400-801, LEAK CHECK GOOD. OPS CHECK GOOD IAW AMM 21-61-00-700-806-002.SDR ASAA2014080808782Hf Comm · malfunctionedHF 1 TRANSMITTED WELL BUT WAS UNREADABLE TO THE PILOTS. ACFT GROUNDED. ACCOMPLISHED NR 1 HF COMMUNICATION SYS TEST, IAW FIM 23-11, TASK 801 AND AMM TASK 23-11-00 VIA SFO, GROUND OPS TEST NORMAL. NO HISTORY LAST 60 DAYS.SDR ASAA2014070708475Module · failedRT CTR FUEL PUMP INOPERATIVE. ACFT GROUNDED. TSR ISSUED. ACCOMPLISHED TSR STEPS 1 THROUGH 4 - NO HELP. RT CTR PUMP LOW PRESSURE LIGHT INTERMITTENTLY ON WITH PUMP OPERATING. WHILE TRANSFERRING FUEL FROM CENTER TANK AFTER TSR, FOUND RT CENTER BOOST PUMP LOW PRSDR ASAA2014062908389Warning Message · false activationON GROUND, AFTER FLAP SELECTION, RECEIVED AN FMC DISAGREE MESSAGE. ACFT GROUNDED. COMPLIED WITH QRH PROCEDURE. RESTORED NORMAL OPERATIONS.SDR ASAA2014061008142Warning Message · illuminatedRIGHT CENTER TANK LOW PRESSURE LIGHT ILLUMINATED WITH 2300 ILS FUEL IN CENTER TANK. ACFT GROUNDED. REPLACED RT CENTER TANK FUEL BOOST PUMP IAW AMM 28-22-41-400-801. PERFORMED OPS TEST REF AMM 28-22-41-710-801. OPS CHECKED GOOD.SDR ASAA2014060808099Warning Message · false activationFMC DISAGREE LIGHT ILLUMINATED. ACFT GROUNDED. QRH FOLLOWED. SYSTEM RESTORED.SDR ASAA2014060608090Regulator · defectiveLEFT PNEUMATIC PRESSURE 20 PSI HIGHER THAN RIGHT PNEUMATIC PRESSURE ON CLIMB, LEFT 40 PSI, RIGHT 20 PSI. IN CRUISE, LEFT 40, RIGHT 25. ACFT GROUNDED. PERFORMED TROUBLESHOOTING ON THE NR 2 ENGINE PNEUMATIC SYSTEM IAW MG-36WC-00001 AND FIM TASK 36-10, TASK 805SDR ASAA2014052707937Indication Sys · malfunctionedRIGHT CENTER LOW PRESSURE LIGHT NEVER EXTINGUISHED DURING CLIMBOUT WITH 1500 LBS OF FUEL. ACFT GROUNDED. PERFORMED FIM, PLACED 14,000 LBS OF FUEL INTO CENTER TANK TO PRIME, NO HELP. CHECKED FOS, NO FAULT FOUND, IAW FIM 28-22, TASK 802. ACCOMPLISHED FIM 28-22,SDR ASAA2014051007747Fmc · malfunctionedIN FLIGHT, EXPERIENCED "FMC DATALINK FULL" ANOMALY. ACFT GROUNDED. AFTER LANDING AT GATE ACCOMPLISHED QRH PROCEDURES IAW HANDBOOK BULLETIN. OPS HAS RETURNED TO NORMAL.SDR ASAA2014030307037Eec · malfunctionedFOUND FAULT 73-20771 "PS3 SIGNAL IS OUT OF RANGE" FOR NR 1 ENGINE. LONG TERM FAULT. ACFT GROUNDED. VERIFIED THAT FAULT CODE 73-20771 IS STILL PRESSENT. R & R THE NR 1 ENGINE EEC IAW AMM 73-21-60-400-801-F00. ACTUATORS TEST OK. ACCOMPLISHED FADEC SVS TEST, SDR ASAA2014020906808Control Valve · malfunctionedDURING CLIMB OUT, RT PACK LIGHT ILLUMINATED. QRH PROCEDURE RAN. LIGHT REMAINED. ACFT GROUNDED. PERFORMED PACK/ZONE TEMP CONTROL BITE. FOUND RT PACK TCV FAULT. REPLACED RT PACK TCV REF: FIM TASK 21-62 TASK 831, MM 21-51-10. OPS CKD GOOD NO FAULTS, REF: MSDR ASAA2014020906806Valve · faultedWHILE PERFORMING BITE CHECK ON NR 1 ZONE TEMP CONTROLLER, FOUND AFT CABIN ZONE TEMP VALVE FAULTED. ACFT GROUNDED. REPLACED AFT CABIN ZONE TEMP VALVE, REF MM 21-61-21, OPS CHECK BITE CHECK GOOD. OK FOR SERVICE.SDR ASAA2014020306767Lens · brokenEMERGENCY EXIT SIGN ON NR 1 GALLEY ADJACENT TO R1 DOOR HAS BROKEN LENS. ACFT GROUNDED. R & R LENS AND TESTED IAW MM 33-51-01-960-801. OPS NORMAL.SDR ASAA2014020306762Control Valve · faultedBITE OF LT PACK- ZONE TEMP CONTROLLER SHOWS FAULT FOR AFT ZONE TEMP CONTROL VALVE TRIM AIR VALVE. VERIFY TEST CONFIRMS FAULT. ACFT GROUNDED. R & R AND TESTED V145 AFT CABIN TRIM AIR VALVE IAW MM 21-61-21-000-801/MM 21-61-21-400-801. OPS NORMAL, NO LEAKS NOSDR ASAA2014020306760Control Valve · malfunctionedRIGHT PACK LIGHT ILLUMINATED ON RECALL. ACFT GROUNDED. GROUND TEST CONFIRMED RT TEMP CONTROL BITE, FAILED THIS PACK TCV IAW FIM 21-62/801. RESET TEMP CONTROLLER. R & R TEMPERATURE CONTROL VALVE RT IAW AMM 21-51-10. OPS CHECKED GOOD.SDR ASAA2014020206755Control Valve · faultedAFTER ENGINE START, ON RECALL, RT PACK LIGHT ILLUMINATED. QRH PROCEDURE FOLLOWED. PACK LIGHT EXTINGUISHED ON MASTER CAUTION RESET. ACFT GROUNDED. PACK-ZONE TEMP CONTROLLER BITE CHECKED IAW FIM 21-62, TASK 801, SHOWED RT PACK TEMP CONTROL VALVE FAULT AND VERSDR ASAA2014013006746Bolt · looseNR 1 ENGINE FAN DUCT PANEL AT 10:00 POSITION HAS LOOSE BOLTS. ACFT GROUNDED. TIGHTENED LOOSE BOLTS.SDR ASAA2014010312318Warning Message · illuminatedFWD WINDSHIELD OVERHEAT LIGHT WILL NOT EXTINGUISH. ACFT GROUNDED. FOUND RT FWD WINDOW HEAT CIRCUIT BREAKER TRIPPED. INSPECTED CIRCUIT BREAKER AND RESET IAW MM 20-60-01. WINDOW HEAT OPS CHECKED GOOD, CONTROLLER BITE TESTED, OPS CHECKED GOOD WITH NO CURRENT FSDR ASAA2013122912262Autopilot Sys · malfunctionedAUTOPILOT A DISENGAGED TWICE WHILE IN CRUISE FL 360 & MMO 0.79. ACFT GROUNDED. CHECKED FAULT REVIEW, 2 OCCURRENCES OF A/P DISCONNECT AT FL 360, BOTH FAULT MCP MX MSG 22-11607. ACCOMPLISHED FIM TASK 22-817 MODE CONTROL PANEL TESTS. ALL TESTS PASS.SDR ASAA2013121696903Fmc · unknownFMC FAILED ON CAPTAIN`S SIDE. ACFT GROUNDED. FMC OPS TEST ACCOMPLISHED, IAW MM 34-61-00. OPS TESTED GOOD. GROUND TEST VERIFICATION SUCCESSFUL. NO HISTORY LAST 30 DAYS.SDR ASAA2013112796552A/C Pack · malfunctionedFUNCTIONAL CHECK FOR PACK, HIGH FLOW INHIBIT FAILED WITH LT PACK OFF, CONFIGURATION WAS ALT 15,000 FT, PRESSURIZATION MODE SELECTOR MANUAL OUTFLOW VALVE ADJUSTED FOR ZERO CABIN RATE OF CLIMB RT PACK AUTO, LT PACK OFF, FLAPS UP. WHEN FLAPS SELECTED 1, CABIN DISDR ASAA2013111496421Warning Light · illuminatedDURING CLIMB, RECEIVED A RT PACK LIGHT. RAN QRH PROCEEDURE AND RESET PACK. PACK LIGHT RE-ILLUMINATED AND SHUTDOWN PACK IAW THE QRH CHECKLIST. ACFT GROUNDED.SDR ASAA2013111496420Warning Message · false activationAFTER ENGINE START, RECEIVED AN FMC DISAGREE MESSAGE. ACFT GROUNDED. RAN QRH PROCEDURE AND OPS RETURNED NORMAL. PERFORMED FMC OPS TEST REF MM 34-61-00-710-801.SDR ASAA2013111296388Warning Message · false activationDURING CLIMB PASSING FL300, RT PACK CAUTION LIGHT ILLUMINATED. RESET RT PACK AND AFTER 30 SECONDS CAUTION LIGHT ILLUMINATED AGAIN. NOTED RT PACK TEMP AT 55C, LT PACK TEMP AT 15C AND RT RAM DOOR OPEN LIGHT ON. CLOSED ISOLATION VALVE AND TURNED RT PACK SWITCHSDR ASAA2013110996349Transmitter · failedON TAXI-IN 1 ENGINE OIL FILTER BY-PASS LIGHT ILLUMINATED. BOXED LIGHT BLINKED UNTIL ENGINE SHUTDOWN. ACFT GROUNDED. ALT. DEACTIVATION PROC. C/W REF MPM 5-07-01 TABLE 3, ITEM 3. REPLACED SCAVENGE OIL FILTER CLOGGING TRANSMITTER REF AMM 79-21-07. REPLACED SCSDR ASAA2013102196221Warning Message · false activationFMC DISAGREE MESSAGE ON GROUND. ACFT GROUNDED. ACCOMPLISHED QRH PROCEDURE. NORMAL OPS RESTORED.SDR ASAA2013102096204Warning Light · illuminatedYAW DAMPER LIGHT ILLUMINATED DURING TAKE OFF. RESET SWITCH AND IT SWITCHED OFF AGAIN. ACFT GROUNDED. FOUND MAINTENANCE MESSAGE 22-22009, SMYD X-CHANNEL BUSS PROBLEM IN IN-FLIGHT FAULTS OF SMYD NR 2. INITIAL EVALUATION REF FIM 22-23, TASK 808 DID NOT CONFIRSDR ASAA2013101496180Autopilot Sys · disengagedAUTOPILOT B DISENGAGED ON ATTEMPTED CAT III A. ACFT GROUNDED. ACCOMPLISHED FIM 22-11, TASK 801, DFCS BITE. OPS CHECKED NORMAL. NO HISTORY 30 DAYS.SDR ASAA2013092596060Warning Light · false activationRT PACK ILLUMINATED ON RECALL AFTER START. PACK LIGHT GOES OUT WHEN MASTER CAUTION IS RESET IAW QRH. ACFT GROUNDED. RT TEMP CONTROLLER BITE SHOWS TCV LAST LEG. RESET REF MM 21-61-00, OPS NORMAL.
Back to N516AS