N520JB
Service difficulty reports · 111
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N520JB' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N520JB' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR YENA2018101500684Epsu · failedFLT 876, KIN-FLL. EMERGENCY ESCAPE PATH FLOOR LIGHT IN ROW 3, 7, 15, 19, 21, 23, 25 AND CEILING LIGHT ROW 12 AND 22 INOP (FLOOR PROX EMERG ESCAPE PATH MARK SYS - INCANDESCENT LIGHTING SYS - NOT APPLICABLE TO (N703 AND UP) ); REMOVED AND REPLACED EPSU AND BATTSDR YENA2018101500683Battery · dischargedFLT 876, KIN-FLL. EMERGENCY ESCAPE PATH FLOOR LIGHT IN ROW 3, 7, 15, 19, 21, 23, 25 AND CEILING LIGHT ROW 12 AND 22 INOP (FLOOR PROX EMERG ESCAPE PATH MARK SYS - INCANDESCENT LIGHTING SYS - NOT APPLICABLE TO (N703 AND UP) ); REMOVED AND REPLACED EPSU AND BATTESDR YENA2018092540356Epsu · failedFLT 950, GND-JFK. DURING WEEKLY CHK, FOUND SOME CABIN EMER LIGHTS INOP. PER EPSU TEST AND FOUND EPSU AT 11WL FAULTY. R&R EPSU AT 11WL PER AMM 33-51-38. BITE CHK PASSED.SDR YENA2018091050333Epsu · failedFLT 531, SLC-LGB. SEAT MOUNTED EMERG LIGHTS AT SEATS/ROWS 3,7,15,19,21,23 & 25 NOT WORKING. TEST OF EPSU (11WL) FAILED. R&R EPSU (11WL) PER AMM 33-51-38. OPS CHECK GOOD. BITE TEST OF EPSU NORMAL. OK FOR SERVICE.SDR YENA20180830325Battery Pack · no testEMERGENCY LIGHT TEST FAILED FOR THE EPSU BATTERY AT FIN 12WL. REMOVED & REPLACED THE BATTERY IAW AMM 33-51-38.SDR YENA20180830324Power Supply · failedEMERGENCY LIGHT TEST FAILED. POWER SUPPLY 11WL FAULTED. REMOVED & REPLACED THE POWER SUPPLY IAW AMM 33-51-38.SDR YENA2018082730322Light · inoperativeFLT 1374, ROW 3 EMERGENCY EXIT SEAT LIGHT INOPERATIVE. R & R THE LIGHT IAW AMM 33-51-18. OPS CHECKED GOOD.SDR YENA2018082730321Epsu · failedFLT 1373, 11WL EPSU INOPERATIVE. R & R THE EPSU IAW AMM 33-51-38. R & R THE BATTERY IAW 33-51-38. OPS CHECKED GOOD.SDR YENA2018082730320Light · inoperativeEMERGENCY LIGHT 204WL WAS INOPERATIVE. R & R THE EMERGENCY LIGHT IAW AMM 33-51-11. OPS CHECKED GOOD.SDR YENA201807060281Epsu · failedFLT 221, BOS-PBI. UPON INSPECTION FOUND NUMEROUS EMER EXIT LIGHTS THROUGHOUT CABIN NOT ILLUMINATING. FOUND EPSU & BATTERY FAULTING AT MID CABIN LEFT LOCATION. R&R W/SERVICEABLE ASSY PER AMM 33-51-38. TEST OK.SDR YENA201807060280Battery · faultedFLT 221, BOS-PBI. UPON INSPECTION FOUND NUMEROUS EMER EXIT LIGHTS THROUGHOUT CABIN NOT ILLUMINATING. FOUND EPSU & BATTERY FAULTING AT MID CABIN LEFT LOCATION. R&R W/SERVICEABLE ASSY PER AMM 33-51-38. TEST OK.SDR YENA2018100540502Skin Panel · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON LT TOP WING SKIN PANEL BTW FASTENER HEADS AT RIB 14 STR 11; PERMANENT REPAIR PERFORMED IAW EO-A32F-4656-00. FASTENER REPLACED AND OVERSIZED IAW SRM 51-42-11. WORK ACCOMPLISHED ON LHT NT 5000761250-0010SDR YENA2018100540501Skin Panel · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED LT TOP WING SKIN PANEL BTW FASTENER HEADS AT RIB 8 ON STR 13; REPAIRED PERFORM IAW LPTR EO-A32F-4656-00. WORK ACCOMPLISHED ON LHT NR 5000761216-0010SDR YENA2018100540500Skin Panel · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON BETWEEN FASTENER HEADS ON LT WING TOP SKIN PANEL AT RIB 9 BETWEEN STR 14-15; PERMANENT REPAIR PERFORMED IAW LPTR EO-A32F057-4656-00 CORROSION REWORK IAW SRM 57-21-00-200-019-600 FASTENER REPLACE AND OVERSIZSDR YENA2018100540499Skin Panel · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON BETWEEN FASTENER HEADS ON LT WING TOP SKIN PANEL UPR SURFACE AT RIB 19 +3 AND 4.92" AFT OF FRONT SPAR; CORROSION REWORKED IAW SRM 57-21-11-283-014 REV 122. WORK ACCOMPLISHED ON LHT NR 5000761256-0010SDR YENA2018100540498Skin Panel · corrodedDURING HEAVY MAINTENANCE, CORROSION WAS DISCOVERED ON BETWEEN FASTENER HEADS ON LT WING TOP SKIN PANEL UPR SURFACE AT RIB 19 +2 ON FRONT SPAR; PERMANENT REPAIR PERFORMED IAW LTPR EO-A32F-57-4656099. CORROSION REWORKED PER SRM TASK. 57-21-11-283-014 REV 122 WORSDR YENA201805240227Epsu · failedDURING HEAVY MAINTENANCE, OPERATIONAL TEST OF EMER LIGHTS FAILED DURING TEST. REPAIRED 3 EA EPSU'S AT (10WL-11WL AND 12WL) AND 1 BATTERY AT (10WL) IAW AMM 33-51-38-000-001-A. SYS OPS CKS NORMAL.SDR YENA201805240226Epsu · failedDURING HEAVY MAINTENANCE, OPERATIONAL TEST OF EMER LIGHTS FAILED DURING TEST. REPAIRED 3 EA EPSU'S AT (10WL-11WL AND 12WL) AND 1 BATTERY AT (10WL) IAW AMM 33-51-38-000-001-A. SYS OPS CKS NORMAL.SDR YENA201805240225Epsu · failedDURING HEAVY MAINTENANCE, OPERATIONAL TEST OF EMER LIGHTS FAILED DURING TEST. REPAIRED 3 EA EPSU'S AT (10WL-11WL AND 12WL) AND 1 BATTERY AT (10WL) IAW AMM 33-51-38-000-001-A. SYS OPS CKS NORMAL.SDR YENA201805294224Battery Pack · failedOPS TEST OF THE EMERGENCY LIGHTS FAILED. REPAIRED THREE POWER SUPPLIES, 10WL, 11WL, AND 12WL) AND ONE BATTERY 10WL IAW AMM 33-51-38-000-001-A. SYS OPS CHECKED NORMAL.SDR YENA2018052940223Skin · damagedDURING HEAVY MAINTENANCE, GOUGE & DENT FOUND ON THE SKIN AT FRAMES 61 - 62, STRINGER 40 - 42L. REPAIRED IAW SRM 53-00-11-300-043.SDR YENA2018052940222Frame · damagedDURING HEAVY MAINTENANCE, FRAME 20, LT SIDE UPPER CORNER FASTENER HOLE ELONGATED. ACCOMPLISHED EC A18-418-01.SDR YENA201712010974Pump · failedFT 1705, MCO-SDQ. HYD G ENG 1 PUMP LO PR. PERFORMED INSP CHECK OF HYD SYS AFT TOTAL HYD LOSS OR ENG PUMP FAILURE OR CAUTION PER AMM 29-00-00. REPLACED GREEN SYS ENG DRIVER PUMP IAW AMM 29-13-51. HP FILTER PER AMM 29-11-45, LP FILTER PER AMM 29-11-44, CASE DRAISDR YENA201711290967Battery Pack · failedFT # 268, PUJ-JFK. FWD "L" + AFT "L" EPSU'S FOUND WITH BATTERY FAULTS DURING EMERGENCY LIGHT TEST; R & R FWD "L" + AFT "L" EPSU BATTERIES IAW AMM 33-51-38. PERFORMED EMERG. LIGHT TEST, TEST OK. SUPPLEMENTAL INFORMATION TO FOLLOW.SDR YENA201710050816Line · failedEMERGENCY DECLARED. CREW OBSERVED A HYD G RSVR LOW LEVEL ECAM. FOLLOWED THE QRH 10-9, TURNED OFF THE GREEN SYSTEM HYDRAULICS. AIRCRAFT LANDED UNEVENTFULLY AND WAS TOWED TO THE GATE. REPAIRED THE CASE DRAIN HYD LINE ON NR 1 ENGINE PYLON IAW 20-23-11. PERFORSDR YENA201707070571Filter · dirtyAT CRUISE IF CREW CALLED THE FLIGHT DECK TO REPORT THAT A CUSTOMER IN ROW 2 SMELLED A DIRTY SOCK ODOR. 2 OUT OF 3 IF CMS CONFIRMED A PERSISTENT ODOR DESCRIBED AS WET MUSTY. AFTER LANDING, IF CREW ADVISED ODOR WAS PERSISTENT, BUT LIMITED TO FWD CABIN. FLIGHT CRSDR YENA201703150186Wire Harness · failedAFTER GEAR RETRACTION, ECAM BRAKES AUTO BRAKE FAULT BRAKES RELEASED. RETURNED TO DEPARTURE. REMOVED AND REPLACED 2M HARNESS IAW AMM 32-11-43 AND PERFORMED OPS CHECK IAW AMM 32-69-00 AND 32-42-00. ALL FUNCTIONS NORMAL. OPENSDR YENA20160705638Stringer · corrodedDURING MAINTENANCE, CORROSION WAS FOUND ON FWD CARGO BAY UNDER FLOOR AREA STR 42L, ONE INCH FWD OF FRAME 26B. REMOVED CORROSION, FABRICATED & INSTALLED FABRICATED STRINGER REPAIRS & INSTALLED SHEAR TIE.SDR YENA20160705637Stringer · corrodedDURING MAINTENANCE, CORROSION WAS FOUND ON FWD CARGO BAY UNDER FLOOR AREA STRINGER 42L, ONE INCH FWD OF FRAME 28. REMOVED SURFACE CORROSION. FABRICATED A REPAIR AND INSTALLED.SDR YENA20160705636Door Sill · corrodedDURING MAINTENANCE, CORROSION WAS FOUND ON BULK CARGO DOOR SILL AROUND FASTENER HOLE, FRAMES 61 +12 AND 60 + 12. REMOVED CORROSION AND REPAIRED DOUBLER MATERIAL. LOCATED AND DRILLED HOLES ON REPAIR DOUBLER ON BULK FRAME C1 & C2 BULK CARGO DOOR SILL. APPLIEDSDR YENA20160705635Stringer Splice · corrodedDURING MAINTENANCE, CORROSION WAS FOUND ON FWD CARGO BAY UNDER FLOOR AREA STRINGER SPLICE ON STRINGER 41L BETWEEN FRAMES 30 - 31. REMOVED AND REPLACED SPLICE.SDR YENA20160705634Door Sill · corrodedDURING MAINTENANCE, CORROSION WAS FOUND ON LEFT AFT CABIN DOOR SILL Y1762 STRINGER 23L FRAMES 66 - 68. REMOVED AND REPLACED THE DOOR SILL.SDR YENA20160705633Web · corrodedDURING MAINTENANCE, CORROSION WAS FOUND ON FWD CARGO BAY UNDER FLOOR AREA DOOR SILL WEB BETWEEN FRAMES 26 - 27 AND STRINGERS 40 - 41R. REMOVED AND REPLACED DOOR SILL WEB.SDR YENA20160705632Threshold · corrodedDURING MAINTENANCE, CORROSION WAS FOUND ON AFT CARGO BAY DOOR THRESHOLD AROUND TIE-DOWN FITTINGS AT FRAMES 53, 54, 55, 56. REMOVED AND REPLACED AFT CARGO BAY DOOR THRESHOLD.SDR YENA20160705631Shear Tie · corrodedDURING MAINTENANCE, CORROSION WAS FOUND ON FWD CARGO BAY UNDER FLOOR AREA SHEAR TIE PLATE ON FRAME 28 AND CENTER STRINGER. REMOVED AND REPLACED SHEAR TIE.SDR YENA20160705630Floorbeam · corrodedDURING MAINTENANCE, CORROSION WAS FOUND ON LEFT AFT CABIN FLOORBEAM Y1292, 1" FWD OF FRAME 68. REMOVED AND REPLACED THE FLOORBEAM.SDR YENA20160705629Shear Tie · corrodedDURING MAINTENANCE, CORROSION WAS FOUND ON SHEAR TIE FRAME 28 AND STRINGER 43L. REMOVED AND REPLACED THE SHEAR TIE .SDR YENA20160705628Floor Support · corrodedDURING MAINTENANCE, CORROSION WAS FOUND ON RT AFT CABIN FLOOR SUPPORT BETWEEN FRAMES 68-69. REPLACED THE FLOOR SUPPORTSDR YENA20160705627Floorbeam · corrodedDURING MAINTENANCE, CORROSION WAS FOUND ON MAIN CABIN FLOORBEAM Y765 AT FRAME 69. REMOVED AND REPLACED MAIN CABIN FLOORBEAM.SDR YENA20160705626Door Sill · corrodedDURING MAINTENANCE, CORROSION WAS FOUND ON RT AFT PASS DOOR SILL FRAME 68. REMOVED CORRODED REPAIR. FABRICATED AND INSTALLED NEW REPAIR.SDR YENA20160705625Shear Web · corrodedDURING MAINTENANCE, CORROSION WAS FOUND ON RT CABIN FLOOR SHEAR WEB AND CHANNEL 8 INCHES FWD OF FRAME 70. REPLACED THE SHEAR WEB AND CHANNEL SUPPORT.SDR YENA20160705624Floorbeam · corrodedDURING MAINTENANCE, CORROSION WAS FOUND ON THE LEFT AFT CABIN FLOORBEAM AT Y765, 2" FWD OF FRAME 66. REPLACED THE FLOORBEAM.SDR YENA20160705623Shear Web · corrodedDURING MAINTENANCE, CORROSION WAS FOUND ON THE LEFT AFT CABIN FLOOR SHEAR WEB AND CHANNEL, 8 INCHES FWD OF FRAME 70. REPLACED THE SHEAR WEB AND CHANNEL SUPPORT.SDR YENA20160705622Dummy Rail · corrodedDURING MAINTENANCE, FOUND CORROSION ON DUMMY RAIL AT Y765-10' CORRODED AT FRAMES 64 - 66. REPLACED THE DUMMY RAIL.SDR YENA20160705621Floorbeam · corrodedDURING MAINTENANCE, CORROSION WAS FOUND ON FLOORBEAM AT -Y254, FRAME 17 TO FRAME 18, STR 23R. REPLACED FLOORBEAM.SDR YENA20160214115Slide · out of positionR1 DOOR WILL NOT LOCK OPEN. SLIDE BUSSEL HITS FUSELAGE. R & R 1 DOOR SLIDE IAW AMM 25-62-44. OPS CHECK GOOD.SDR YENA20150816373Battery Pack · inoperativeDURING MAINTENANCE FOUND EMERGENCY LIGHT FAILED SYSTEM TEST. R & R BATTERY ASSY AT 10WL AND 12WL. OPS CHECKED GOOD IAW AMM 33-51-38.SDR YENA20150816372Battery Pack · inoperativeDURING MAINTENANCE, FOUND EMERGENCY LIGHT FAILED SYSTEM TEST. R & R BATTERY ASSY AT 10WL AND 12WL. OPS CHECK GOOD IAW AMM 33-51-38.SDR YENA20141018230Skin · corrodedDURING HEAVY MAINTENANCE CHECK, CORROSION FOUND ON THE RT WING TOP SKIN T/E. REMOVED CORROSION AND REPAIRED RT WING TOP SKIN IAW PT20-57-023 AND A14-661-01.SDR YENA20141018229Skin · corrodedDURING HEAVY MAINTENANCE CHECK, CORROSION WAS FOUND ON LT WING TOP SKIN T/E IAW EC A320-57-1154-01/02. REMOVED CORROSION IAW SRM 51-74-00, SRM 51-42-11 AND A14-661-01.
Back to N520JB