N582UP
Service difficulty reports · 231
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N582UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N582UP' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IPXA1B66721Hinge Fitting · wornINSPECTION TYPE:D, LT WING OTBD AIL MOST OTBD HINGE FITTING WEB AT WS 1480 FOUND WORN. LT WING OTBD AIL MOST OTBD HINGE FITTING WEB AT WS 1485 AREA REPLACED & INSTALLED IAW HX RS R-57-20-37052, REV A & EO B747-5740-42420-A ORG MAT IS 0.036"(0.016"+0.020") BMSSDR IPXA1666385Skin · misrepairedINSPECTION TYPE:C, RT WING INBD FORE FLAP T/E LOWER SURFACE OTBD AREA EXISTING REPAIR (NON STANDARD) REDO. FIBERGLASS PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-07, PAR 5C, FIG 2, REV 59.SDR IPXA1666351Skin · misrepairedINSPECTION TYPE:C, RT WING OTBD FORE FLAP L/E LOWER SURFACE OTBD AREA EXISTING REPAIR (NON STANDARD REPAIR) REDO. FIBERGLASS PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-07, PAR 5A, FIG 5, REV 59.SDR IPXA1666349Skin · misrepairedINSPECTION TYPE:C RT WING INBD FORE FLAP T/E LWR SURFACE EXISTING REPAIR (NON STANDARD REPAIR) REDO. FIBERGLASS PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-07, PAR 5C, FIG 2, REV 59.SDR IPXA1666348Skin · misrepairedINSPECTION TYPE:C, RT WING INBD FORE FLAP T/E LWR SURFACE MID AREA EXISTING REPAIR (NON STANDARD REPAIR) REDO. FIBERGLASS PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-07, PAR 5C, FIG 2, REV 59.SDR IPXA1666347Skin · misrepairedINSPECTION TYPE:C, RT WING INBD FORE FLAP T/E LOWER SURFACE MID AREA EXISTING REPAIR (NON STANDARD REPAIR). FIBERGLASS PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-07, PAR 5C, FIG 2, REV 59.SDR IPXA1666346Skin · misrepairedINSPECTION TYPE:C, RT WING OTBD FORE FLAP L/E LOWER SURFACE OTBD AREA EXISTING REPAIR (NON STANDARD) REDO. FIBERGLASS PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-70, PAR 5C, FIG 2, REV 59.SDR IPXA11B66983Skin · misrepairedINSPECTION TYPE:D, RT WING OTBD FORE FLAP L/E LOWER SURFACE MID AREA EXISTING REPAIR (NON STANDARD REPAIR) FIBERGLASS PREPREG LAY UP REPAIR CARRIED OUT IAW SRM 51-70-07, PAR 5L, FIG 2, REV 59.SDR IPXA1666373Skin · wornINSPECTION TYPE:C, RT WING OTBD T/E AFT FLAP UPR SURFACE PANEL 688KT OTBD FWD AREA FOUND WORN. METAL HOT BOND REPAIR PERFORMED IAW SRM 51-70-10-2R, REPAIR 4, FIG 202, SHEET 2, REV 59.SDR IPXA1666437Skin · wornINSPECTION TYPE:C, RT WING OTBD T/E AFT FLAP UPPER SURFACE PANEL, 688IT, FOUND WORN. METAL HOT BOND REPAIR PERFORMED IAW SRM 51-70-10-2R, REPAIR 4, FIG 201, SHEET 1, REV 59.SDR IPXA1B66699Support · corrodedINSPECTION TYPE:D, FX BODY FAIRING 193CL ATTACHMENT SUPPORT FOUND CORROSION AT BL 0 AS MARKED. FX BODY FAIRING NR 193CL ATTACHMENT SUPPORT AT BL 0 REPLACED IAW SRM 51-10-02, REV 59 AND FASTENERS INSTALLED IAW SRM 51-40-02, REV 59. THIS REPAIR IS CLASSIFIED ASDR IPXA1B66698Crease Beam · crackedINSPECTION TYPE:D, M/D STA 960, LT CREASE BEAM WEB CRACKED AT STR 7L AREA M/D STA 960, LT CREASE BEAM AT STR 7L. AREA ATTACH WEB REPLACED AND INSTALLED IAW HX RS R-53-20-37044, REV A & EO B747-5310-42616-A. THIS IS CATEGORY A REPAIR & CLASSIFIED AS MINOR REPSDR IPXA1B66697Attach Angle · crackedINSPECTION TYPE:D, M/D STA 960, LT CREASE BEAM TO FRAME ATTACH ANGLE CRACKED AT STR 7L AREA M/D, STA 960, LT CREASE BEAM TO FRAME ATTACH ANGLE AT STR 7L AREA. REPLACED AND INSTALLED IAW HX RS R-53-20-37044, REV A AND EO B747-5310-42616-A. THIS IS A CATEGORY SDR IPXA1B66696Attach Angle · crackedINSPECTION TYPE:D, M/D STA 960 RT CREASE BEAM TO FRAME ATTACH ANGLE CRACKED AT STR 7R AREA. M/D STA 960, RT CREASE BEAM TO FRAME ATTACH ANGLE REPLACED & INSTALLED AT STR 7R AREA IAW HX RS R-53-20-37044, REV A & EO B747-5310-42616-A. THIS IS A CATEGORY A REPASDR IPXA1B66695Crease Beam · crackedINSPECTION TYPE:D, M/D STA 980 RT CREASE BEAM WEB CRACK AT STR 5R AREA. M/D STA 980, RT CREASE BEAM WEB AT STR 5R AREA REPLACED AND INSTALLED IAW HX RS NO R-53-20-37045, REV A AND EO NR B747-5310-42617-A, THIS IS A CATEGORY A REPAIR & CLASSIFIED AS MINOR REPASDR IPXA1B66718Skin · damagedINSPECTION TYPE:C, AFT CARGO DOOR LWR EDGE MID AREA FOUND LOCAL BLEND MARK. REPAIRED IAW HX RS R-52-30-27053 REV A AND EO B747-5230-42564-A ORG MAT'L 202473 0.063" OUTER SKIN AND 0.063 CHEM MILLED DOUBLER LOCAL BLENDED 0.650" X 19.75" WITH 0.5"R AT THE NOTCHSDR IPXA1666441Skin · damagedINSPECTION TYPE:C, RT WING OTBD AILERON MOST INBD HINGE UPPER SURFACE SKIN FOUND DAMAGED. SKIN BETWEEN AIL STA 0 TO 31-75 REPAIRED IAW HX RS R-57-60-37036, REV A & EO B747-5750-42419-A. ORIG MATL CLAP 2024T3 0.020" (2 PLIES), CHAFED AREA 8.75"X1.5", DENTED ASDR IPXA1B66702Skin · misrepairedINSP TYPE:D, REPAIR DOES NOT CORRELATE TO A SRM. REPAIRED IAW HX RS NR R-57-44-37048, REV A & EO NR B747-5750-42645-A, ORG MAT'S IS CLAD 2024T42-0.040" DENT AREA IS 0.022" DEPTH X 0.075" WIDTH & 1.25" LENGTH. THIS REPAIR IS CLASSIFIED AS A MAJOR REPAIR.SDR IPXA1666435Skin · puncturedINSPECTION TYPE:C, RT WING OTBD MID FLAP UPPER PANEL 687MT FOUND PUNCH HOLE. METAL HOT BOND REPAIR PERFORMED IAW SRM 51-70-10-2R. REPAIR 2, FIG 203, REV 59.SDR IPXA1B66720Panel · crackedINSPECTION TYPE:C, M/D L5 DOOR FWD CUTOUT REVEAL PNL CRACK. M/D L5 DOOR FWD CUTOUT REVEAL PANEL DOUBLER & LWR REVEAL PANEL BETWEEN LT STA 2231 AND STR 21L-22L AREA REPAIRED IAW HX RS R-53-00-37051, REV A AND EO B747-5310-42737-A. THIS REPAIR IS A CATEGORY B RSDR IPXA1B66717Rib · corrodedINSPECTION TYPE:D, FX STA 1045, BL 0 KEEL BEAM PANEL SUPPORT RIB FOUND CORRODED FX AT STA1045 BL0"-LBL 7" AREA PNL SUPT REPAIRED IAW SRM 53-00-71, FIG 201, REPAIR 3 REV 59 ORG MAT IS BAC1505-100081 7075T73-100 THK CORROSION BLEND OUT AREA 0.037" DEPTH 1" WIDSDR IPXA1B66716Rib · corrodedINSPECTION TYPE:D, FX STA 1120, BL0 KEEL BEAM PNL SUPT RIB FOUND CORRODED. CORROSION REMOVED & REPROTECTED IAW SRM 51-10-02 AND 51-20-01 REV 59. ORG THK 0.100". BEND DEPTH 0.006" X WIDTH 1", LENGTH 2" WITHIN SRM 53-00-71 ALLOWABLE DAMAGE 1 FIG 101 REV 59 SDR IPXA1B66715Rib · corrodedINSPECTION TYPE:D, FX STA 1120, BL 0 KEEL BEAM PANEL SUPPORT RIB FOUND CORRODED. CORROSION REMOVED & REPROTECTED IAW SRM 51-10-02 AND 51-20-01 REV 5 59. ORG THK 0.100". BLEND DEPTH 0.006" X WIDTH 1", LENGTH 2" WITHIN SRM 53-00-71 ALLOWABLE DAMAGE 1, FIG 10SDR IPXA1B66700Rib · corrodedINSPECTION TYPE:D, STA 960-987 LBL 5" AREA BODY FAIRING SUPPORT RIB FOUND CORRODED. FX - STA 960-987 LBL 5" AREA BODY FAIRING SUPPORT RIB REPLACED AND INSTALLED IAW SRM 51-10-02 AND 51-40-02, REV 59. THIS REPAIR IS CLASSIFIED AS MINOR REPAIR.SDR IPXA11666265Skin · misrepairedINSPECTION TYPE:C, LT VERTICAL STABILIZER LOWER PANEL EXTERNAL AREA (NON-STANDARD REPAIR). METAL HOT BOND REPAIR PERFORMED IAW SRM 51-70-10-2R, REPAIR 4, FIG 201, SHEET 3, REV 59.SDR IPXA1666436Skin · debondedINSPECTION TYPE:C, RT WING T/E INBD MID FLAP UPPER SURFACE PANEL 677IT FOUND DEBONDED. METAL HOT BOND REPAIR PERFORMED IAW SRM 51-70-10-2R, REPAIR 2, FIG 203, REV 59.SDR IPXA1666375Skin · damagedINSPECTION TYPE:C, RT WING OTBD T/E AFT FLAP UPPER PANEL 688JT FOUND DAMAGED. METAL HOT BOND REPAIR PERFORMED IAW SRM 51-70-10-2R, REPAIR 4, FIG 202, SHEET 1, REV 59.SDR IPXA1666374Skin · wornINSPECTION TYPE:C, RT WING OTBD T/E AFT FLAP UPPER SURFACE PANEL 688KT MID AFT AREA FOUND WORN. METAL HOT BOND REPAIR PERFORMED IAW SRM 51-70-10-2R, REPAIR 4, FIG 202, SHEET 2, REV 59.SDR IPXA1666340Panel · debondedINSPECTION TYPE:C, RT WING T/E OTBD FORE FLAP, OTBD UPPER PANEL FOUND DISBONDED. METAL HOT BOND REPAIR PERFORMED IAW SRM 51-70-10-2R REPAIR 2, FIG 203, REV 59.SDR IPXA1B66719Skin · misrepairedINSPECTION TYPE:C FUSELAGE SKIN AT BETWEEN BS 2635-2661 WL 308-WL318 AREA REPAIR DOES NOT CORRELATE TO THE REPAIR CONFIGURATION IN THE EFN DOCUMENTATION. REPAIRED IAW HX RS R-53-80-37049 REV A & EO B747-5330-42742-A. ORG MAT 2024T3 (2 PLIES) 0.016. EXISTINGSDR IPXA1666442Floor Panel · damagedINSPECTION TYPE:C, M/D STA 1220-1260 LT MOST OTBD FLOOR PANEL FOUND SPONGEY. FLOOR PANEL LOCAL FABRICATED IAW DWG 65B15753-21.