N591NW
Service difficulty reports · 166
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N591NW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N591NW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2020112903898Strap · crackedDURING INSPECTION FOUND CRACK ON STABILIZER STRAP STA 1661 AND 25 RBL AT PASSENGER CABIN FLOOR STRUCTURE. STRAP REPAIRED, PER SRM 53-00-51.SDR DALA2020071092562Indicator · out of adjustR4 DOOR KNUCKLE KNOCKER ARMED IN DICATION NOT PROPERLY RETRACTING AND EXTENDING PER PILOT AND FA PROCEDURES. ADJUSTED THE KNUCKLE KNOCKER, CHECKS NORMAL IAW AMM 52-11.SDR DALA2020071072563Reservoir · low pressureDURING A SERVICE CHECK, FOUND THE L2 DOOR EMP POWER RESERVOIR EMPTY. REMOVED AND REPLACED L2 DOOR ASSIST RESERVOIR ASSY IAW AMM 52-11-30. PRESSURE CHECKED GOOD.SDR DALA2020070202529Battery Pack · dischargedEMERGENCY LIGHTS INOP AT L4 DOOR AND ROWS 46-49. R/R BATTERY PACK AT M737 PER AMM 33-51. OPS CHK GOOD.SDR DALA2020033002078Warning System · false activationSHIP 5811 RECEIVED L CTR ENT DOOR EICAS MESSAGE. REFERENCED QRH. CORRECTIVE ACTION: PERFORMED DOOR CHECK ON 2L REF B757AMM 52-11. DOOR OPERATES AND INDICATES NORMAL. (6680412)SDR DALA2020021421157Bypass Valve · leakingSHIP 5811 -FUME- A OILY DIRTY SOCK ODOR WAS REPORTED IN THE COCKPIT AND CABIN, O2 MASKS WERE DONNED. CORRECTIVE ACTION: FOUND SLAT BYPASS VALVE LEAKING INTO (L) PACK BAY, SECURED LINE, CLEANED PACK BAY OP CHECKS NORMAL. C/W REMOVAL OF OIL CONTAMINATION IN A/C SDR DALA2020020430882Battery Pack · inoperativeSHIP 5811 SEAT 28E LOWER EMERGENCY EXIT SIGN INOP. CORRECTIVE ACTION: FOUND BATTERY PACK EQUIPMENT # M11384 DEAD R/R BATTERY PACK IAW B757 AMM 33-51. OPS NML. (6438745)SDR DALA201912317637Battery Pack · inoperativeEMERGENCY EXIT LIGHTS INOPERATIVE AT SEATS 24 - 26DEF, BINS 34, 42 AND 44, OVERWING EXITS, AND EXIT. R & R TWO BATTERY PACKS FOR EMERGENCY LIGHTING IAW AMM 33-51. OPS CHECKED GOOD.SDR DALA2019120216992Fuse · failedSHIP 5811 EMER LIGHTS INOP ROWS 46-49. CORRECTIVE ACTION: REPLACED FUSE POWER SUPPLY M737 REF B757 WDM 33-51-22 AND B757 AMM 33-51-07-962-017-002. OPS GOOD. (6363255)SDR DALA201910145880Battery Pack · no testEMERGENDCY LIGHT POWER SUPPLY BATTERY PACKS M11613 AND M11487 WILL NOT KEEP EMERGENCY LIGHTS ILLUMINATED FOR AT LEAST 15 MINS. REPLACED THE BATTERY PACKS. OK FOR SERVICE IAW AMM 3351.SDR DALA2019092405537Cap · defective(AIRCRAFT 5811, L/P 1282803) SLIDE INDICATOR LIGHT INOP OR DAMAGED / LOCATIONS: 4R. 4R SLIDE LIGHT WAS ON BUT TURNING OFF AFTER TAKEOFF EVEN THOUGH DOOR WAS STILL IN ARMED POSITION. CORRECTIVE ACTION: R/R R4 DOOR SLIDE LIGHT CAP L408 PER SSM 25-66-01. C/W W/C SDR DALA2019092005454Engine · making metalSHIP 5811- IFSD & DIV - AIRCRAFT DIVERTED INTO DEN DUE TO PILOT REPORT OF RIGHT ENGINE STALL THEN ROLL BACK TO IDLE. ENGINE SUBSEQUENTLY SHUT DOWN. CORRECTIVE ACTION: MAINTENANCE FOUND METAL IN THE TAILPIPE. ENGINE CHANGE ACCOMPLISHED ON LOGPAGE 1276788.SDR DALA2019052203138Sensor · defectiveSHIP 5811 -DIV- DIVERED TO DEN DUE TO LEFT ENGINE BLEED OFF LIGHT AND EICAS MESSAGE AT FL 360 AND ENGINE ANTI-ICE ON. FOLLOWED QRH AND RECEIVED RIGHT ENGINE BLEED OFF LIGHT AND EICAS MESSAGE. DESCENDED OUT OF VISIBLE MOISTURE AND RESET ENGINE BLEED AND SAME COSDR DALA2019051603062Power Supply · inoperative(AIRCRAFT 5811, L/P 5646771) DURING SVC CK FOUND EMERGENCY BATT POWER SUPPLY M11383 INOP. R/R PWR SUPPLY & BATTERY POS M11383 REF AMM 33-51. OPS NML.SDR DALA2019031701790Angle · damagedSHIP 5811 LWR AFT T-ANGLE ON RT HORIZONTAL STAB DAMAGED 30" IB FROM O/B EDGE. CORRECTIVE ACTION: REPAIRED PER ERA 576304-14 REV A. (5818719)SDR DALA2019010400080Lens · missingSHIP 5811 EMERGENCY EXIT SIGN LENS MISSING AT ROW 38. CORRECTIVE ACTION: REPLACED LENS, CKS OK PER AMM 33-51. (5280258)SDR DALA2018110986565Pin · broken(AIRCRAFT 5811, L/P 0817270) L-4 DOOR EMERGENCY EXITSLIDE HAS LACING PIN DAMAGED/ BROKEN. DOT 004. I-29. REMOVED AND REPLACED L-4 DOOR EMERGENCY ESCAPE SLIDE IAW AMDS 2566-9001-4L.SDR DALA2018062504189Engine · malfunctionedLEFT ENGINE POPPING NOISE REPORTED BY TOWER AND OTHER AIRCRAFT. INSPECTED BOTH ENGINE INLETS AND OUTLETS, MASTER CHIP DETECTORS AND MCD'S IAW AMM 79-21- NTF. DOWNLOADED PCMCIA CARD BUT CARD UNABLE TO LOAD, R & R PCMCIA CARD IAW AMM 31-36. FOUND EPCS MESSAGE SDR DALA2017101907683Lamp · inoperativeROW 30 AND 33 OVERHEAD BIN MOUNTED EMERGENCY LIGHTS INOPERATIVE. REPLACED THE LAMPS. OPS CHECKED GOOD. OK FOR SERVICE.SDR DALA2017090500002Fuse · trippedLEFT OVERWING DOOR EMERGENCY LIGHTS INOPERATIVE. FOUND THE FUSE TRIPPED ON THE PSU, AFTER REPLACING FUSES ON PSU. FOUND SHORTED LIGHT BULB HANDLE LIGHT IAW WDM 33-51-13. REPLACED THE LAMPS. CHECKED OK.SDR DALA2017053104521Light · detachedEMERGENCY LIGHT AT 48 D IS DETACHED. INSTALLED NEW BRACKET. OK FOR SERVICE.SDR DALA2017051804037Gasket · leakingENROUTE, AIRCRAFT LOST THE RT HYD QTY FLUID. DURING APPROACH WITH FLAPS AT 30, THE AIRCRAFT EXPERIENCED A ROLL TO THE LEFT. CREW DID A GO AROUND, EXTEND THE FLAPS AND EXPERIENCED THE SAME PROBLEM. PLACED THE FLAPS AT 25 WITH NO PROBLEM. MAINTENANCE TROUBLESSDR DALA2017041703168Wire · brokenEMERGENCY LIGHT AT ROW 33D INOPERATIVE. FOUND A WIRE BROKEN UNDER SEAT. REPAIRED IAW SWPM 20. OPS CHECKED GOOD. OK FOR SERVICE.SDR DALA2017030701910Sign · missingBACK SIDE OF CENTER AISLE OVERHEAD "EXIT SIGN MISSING BY ROW 38. REPLACED MISSING OVERHEAD EXIT SIGN AT ROW 38.SDR DALA2017030701853Light · inoperativeDURING A SERVICE CHECK, FOUND EMERGENCY LIGHT INOPERATIVE AT ROW 43. REMOVED AND REPLACED THE LIGHT ASSY IAW AMM 33-50. OPS CHECKED GOOD.SDR DALA2017011300408Wire · brokenFLOOR PATH EMERGENCY LIGHTS ARE INOP AT SEATS 14 DEF TO 20 DEF. INSP AND FOUND EMERGENCY LIGHT WIRING BROKEN UNDER SEAT ROW 20 DEF. REPAIRED WIRING UNDER SEAT. ALL LIGHTS OPS NORMAL.SDR DALA2016112109013Housing · damagedSEAT 35 RT EEPLS HOUSING DAMAGED. R&R SEAT 35 RT EEPLS HOUSING OK FOR SERVICE.SDR DALA2016060804591Light · brokenEMERGENCY LIGHT UNDER 42D BROKEN. SEAT 42D UNDERSEAT EMERGENCY ESCAPE PATH LIGHT IS OPERATIVE BUT LIGHT ASSY BROKEN. TEMPORARILY SECURED IN PLACE WITH REINFORCING TAPE. DEFERRED LIGHT ASSY REF MEL 33-51-03A. REPLACED COVER IAW CMM 25-22 MEL/PLAC REMOVED.SDR DALA2015051203208Power Supply · inoperativeDURING ACFT SERVICE CHECK, FOUND EMERGENCY LIGHTING INOPERATIVE AT ROWS 33-36, 37-39. FOUND POWER SUPPLY AT FS 1334 OVERHEAD INOPERATIVE 1 OF 2. ABOVE CEILING PANEL R & R LT POWER PACK SUPPLY ASSY AND LOOSE PLUG ASSY. "D9104J" REF FS 1210 WIRING DIAGRAM 33-51SDR DALA2015021601246Engine · making metalDURING FLIGHT, DIVERTED DUE TO RT ENGINE OIL FILTER EICAS MESSAGE. INDICATION DID NOT EXTINGUISH WITH THROTTLE AT IDLE. ENGINE WAS SHUTDOWN IAW QRH. MAINTENANCE FOUND OUT OF LIMITS METAL IN MAIN OIL FILTER, MASTER CHIP DETECTOR AND NR 5 BEARING CHIP DETECTORSDR DALA2014111006038Stringer · crackedCRACK ON END OF STRINGER 16R AT BS 780+36 RG1. REPAIRED STRINGER IAW ER/A 515773-14, REV ORIG.SDR DALA2014111006037Stringer · crackedCRACK ON END OF STRINGER 16L AT BS 780+36 RG3. REPAIRED STRINGER IAW ER/A 528685-14, REV ORIGINAL.SDR DALA2014110705972Structure · puncturedPREVIOUS REPAIR HAS A VOID IN SEALANT ON THE LT WING OTBD AFT FLAP LOWER SURFACE AT APPROXIMATELY STA 537. REPAIRED HONEYCOMB PUNCTURE DAMAGE, PERFORMED WATER EVAC & APPLIED PRIMER & TOP COAT FINISHES TO THE LEFT WING OTBD AFT FLAP LOWER SURFACE AT APPROXIMATSDR DALA2014110605969Cable · out of adjustDOOR FAILED EMERGENCY POWER ACTUATION CABLE TRAVEL CHECK. ADJUSTED EMERGENCY POWER ACTUATION CABLE IAW AMM 52-11.SDR DALA2014110605966Crease Beam · corrodedCORROSION ON RT MAIN CABIN CREASE BEAM INNER ANGLE AT BS 1260. REPAIRED IAW ERA 529963-14, REV-ORIG.SDR DALA2014110605971Girt Bar · no testR1 DOOR FORWARD FLOOR FITTING ON GIRT BAR FAILED GO-NO-GO TEST. R & R R-1 DOOR GIRT BAR.SDR DALA2014110505942Stringer · corrodedCRACK ON END OF STRINGER 16R BS 780+24. REMOVED, FABRICATED AND INSTALLED STRINGER SECTION AT STRINGER IAW SRM.SDR DALA2014110505941Seat Track · corrodedCORROSION ON MAIN CABIN SEAT TRACK BS 377.7, LBL 071 94. FOUND OUT OF LIMITS IN IAW SRM. R & R SEAT TRACK SUPPORT.SDR DALA2014110505940Crease Beam · corrodedCORROSION ON THE RIGHT CREASE BEAM INNER ANGLE BETWEEN BS 730 TO 740. REMOVED CORROSION AND FOUND OUT OF LIMITS. R & R CREASE BEAM IAW SRM.SDR DALA2014110305896Strap · crackedFWD CARGO CEILING STABILIZER STRAP RBL 25 IS CRACK AT BS 700. REPAIRED IAW ERA 384483-14 MA REV-D.SDR DALA2014110305893Stringer · crackedCRACK ON END OF STRINGER 16L AT BS 780+24. REMOVED, FABRICATED AND INSTALLED NEW STRINGER IAW SRM.SDR DALA2014110305892Strap · crackedFWD CARGO BAY CEILING STABILAZATION STRAP LBL 25 IS CRACKED AT BS 580. CEILING STABILIZATION STRAP REPAIRED IAW ERA 384483-14 REV.-D.SDR DALA2014110505943Angle · crackedFWD CARGO DOOR INTERNAL STRUCTURES HAS UPPER ANGLES CRACKED ON FWD AND AFT CORNERS 97-09. FABRICATED AND INSTALLED 2EA UPPER ANGLES ON FWD CARGO COMPARTMENT DOOR INTERNAL STRUCTURE IAW SRM.SDR DALA2014110605967Seat Track · corrodedCORROSION ON MAIN CABIN SEAT TRACK AT BS 1640, RBL 46. REMOVED THE CORROSION AND FOUND TO BE OUT OF LIMITS. R & R THE SEAT TRACK IAW SRM.SDR DALA2014102805806Seat Track · misalignedSEAT TRACK SPLICE AT BS 1600, FOUND MISMATCH CONDITION RBL 24, RBL 45 AND LBL24 AND LBL 45. REPAIRED THE SEAT TRACK MISMATCH CONDITION IAW ER/A 528656-14 REV ORIG.SDR DALA2014102505791Strap · crackedFWD NOSE COMPARTMENT LT TUNNEL CEILING STABILIZATION STRAP IS CRACKED AT LBL 46 BS 365. REPAIRED THE STRAP IAW ER/A 384483-14MA, REV D.SDR DALA2014101405554Battery Pack · no testBATTERY PACK DID NOT POWER LIGHTS FOR 15 MINUTES. R & R BATTERY PACK IAW AMM 33-51.SDR DALA2014071404083Lens · missingEXIT ROW SEAT 26C RED LENS MISSING. R & R EMERGENCY LIGHT ASSY.SDR DALA14008325811Wire · brokenSEAT ROWS 14-20 EMERGENCY LIGHTS INOPERATIVE. WIRE BROKEN FOUND. REPAIRED WIRE IAW WSPM 20-30. OPS CHECKED OK.SDR DALA13068275811Wire · damagedBOTH EMERGENCY LIGHT MODULES ON SEAT 25C INOPERATIVE. FOUND BROKEN SPLICE ON HARNESS. REPAIRED SPLICE IAW SWPM CHAP 20-30. BOTH LIGHT MODULES ON SEAT 25C, OPS CHECKED.