N605KS

Service difficulty reports · 153

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N605KS' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR SIMA20211223001None · noneMAIN DOOR EMERGENCY LIGHT INOP-C/A-RAR MAIN DOOR EMERGENCY LIGHT LAMP IAW EMB AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. OPS CHECK GOOD. NO DEFECTS NOTED. END.Dec 23, 2021 · N605KS · Emb EMB145LR · Emergency LightingSDR SIMA20211115001Warning Message · false activationTAKEOFF 1000 CLIMBING 115 VAC BUS OFF CAUTION LOSE EICAS INDICATIONS ITT, N1, T/O, N2. PPH, FLAPS, GEAR ALL YELLOW DASH RUN QRH. SPS 1/2 INOP WARNING ON CLIMBOUT ALONG WITH ALL MSG STATED ABOVE AIR RETURN TO AZO-C/A-PERFORMED OPC CHECK OF DAU1 REF. AMM 31-41-0Nov 15, 2021 · N605KS · Emb EMB145LR · Central WarningSDR SIMA20211103007None · noneBLEED 2 LEAK WARNING MESSAGE DECLARED EMERGENCY FLIGHT CONT.-C/A-CHECKED ORINGS ON#2 BLEED SYSTEM #2 THROUGH #26 AND FOUND NO LEAKS PER ETN EM-36-048 AND RAN #2 ENGINE BLEED SOURCE REF EMB 145 AMM 36-11-05. OPS CHECK GOOD.Nov 3, 2021 · N605KS · Emb EMB145LR · Pneumatic SystemSDR SIMA20211019001None · none"TRANSFERRED FROM AML PAGE 4607688 ITEM 2" REF. ITEM 1 OF THIS LG. PG. INSPECTED F/O'S DV WINDOW AND FOUND F/O'S DV WINDOW FUSELAGE FRAME CRACKED AT FWD LOWER CORNER FRAME 9, LOWER DOUBLER. MAJOR REPAIR -C/A-REPAIRED F/O'S DV WINDOW FUSELAGE FRAME THAT WAS CRAOct 19, 2021 · N605KS · Emb EMB145LR · Fuselage Main, StructureSDR SIMA20211007003None · noneMAIN DOOR EMERGENCY LIGHT INOP.-C/A-RAR MAIN DOOR EMERGENCY LIGHT IAW EMB 145 AMM 33-50-06 OCK GOODOct 7, 2021 · N605KS · Emb EMB145LR · Emergency LightingSDR SIMA20210619004Thermal Switch · faultedBLEED 2 LEAK MESSAGE DURING CLIMB MESSAGE REMAINED DESPITE COMPLETING QRH PROCEDURE-C/A-FOLLOWED FIM TASK 36-20-00-800-802-A, DETERMINED ITS A FAULTY THERMAL SWITCH. CLEANED AFT THERMAL SWITCH BY THE AIR GROUND CONNECTION FROM LAVATORY FLUID. THERMAL SWITCH/DUJun 19, 2021 · N605KS · Emb EMB145LR · Pneumatic Indicating SystemSDR SIMA20210517001O-Ring · leakingBLEED 2 LEAK CLIMBING THROUGH APROX 8000' EXECUTED CHECKLISTS RETURNED TO DFW W/' UNDERWEIGHT LANDING DECLARED EMERGENCY-C/A-FOUND #25 BLEED SYSTEM JOINT HISSING/LEAKING. RAR 2 ORINGS IN REF TO AMM 36-11-10. LEAK CHECK GOOD.May 17, 2021 · N605KS · Emb EMB145LR · Pneumatic Distribution SystemSDR SIMA20210415004Warning Message · false activationBLD 2 LEAK ON CLIMB OUT DECLARED EMERGENCY -C/A-SUSPECT BAD DUCT LEAK DETECTOR.PERFORMED CONTINUITY TEST FORM CONNECTOR J1020 PN A-6 TO GROUND IAW SWPM 20-20-03. CONTINUITY TEST GOOD PIN A-6 HAS NO CONTINUITY TO GROUND.Apr 15, 2021 · N605KS · Emb EMB145LR · Central WarningSDR SIMA20210322004Warning Message · false activationBLEED 2 LEAK CLIMBING OUT OF 10K' RAN QRH, NO REMEDY, DIVERTED TO ABI, NORMAL LNG @ 43.5K LBS. UPON PARKING WE SAW THE MESSAE CLEAR AND THEN REAPPEAR 2X. ACCOMPANIED BY DAU 2 MISHAP"TRANSFERRED TO NRWC 605-ABI-03404" AARON JOHNSON 756610-C/A-RAR THERMAL SWITCHMar 22, 2021 · N605KS · Emb EMB145LR · Pneumatic Indicating SystemSDR SIMA20210320001Lamp · inoperativeFOUND MAIN DOOR EXTERNAL EMERGENCY LIGHT INOP-C/A-RAR MAIN DOOR EXTERNAL EMERGENCY LIGHT LAMP IN REF WITH EMB 145 AMM 33-50-10. OPS CHECK GOOD.Mar 20, 2021 · N605KS · Emb EMB145LR · Emergency LightingSDR SIMA20210227001Bulb · inoperativeR/H EXTERIOR EMEREGNCY LIGHT FORWARD OF WING INOP-C/A-RAR BULB PER AMM 33-50-10.Feb 27, 2021 · N605KS · Emb EMB145LR · Emergency LightingSDR SIMA20210211001Lamp · inoperativeDURING PS-1 CHECK FOUND RH FOWAD LOWER FAIRING EMERGENCY LIGHT INOP.-C/A-RAR RH FOWARD LOWER FAIRING EMERGENCY LIGHT LAMP IAW 33-50-10Feb 11, 2021 · N605KS · Emb EMB145LR · Emergency LightingSDR SIMA20210108001Cradle · brokenAFT EMERGENCY CABIN FLASHLIGHT CRADLE BROKEN MEL 2553-AUTH NR 01-85-C. C/A: R & R AFT EMERGENCY CABIN FLASHLIGHT CRADLE, IAW EMB AMM 33-50-16-000-801-A AND 33-50-16-400-801-A. OPERATIONS CHECKED GOOD. MEL RESTROED.Jan 8, 2021 · N605KS · Emb EMB145LR · Emergency EquipmentSDR SIMA20210104002Cradle · brokenAFT CABIN EMERGENCY FLASHLIGHT CRADLE BROKEN. C/A: DEFFERED PER MEL 25-53.Jan 4, 2021 · N605KS · Emb EMB145LR · Emergency EquipmentSDR SIMA20201231003Switch · malfunctionedBLEED 2 LEAK. DECLARED EMERGENCY "TRANSFERRED TO NRWC 605-DFW-03237". C/A: REPLACED ENGINE START GROUND CONNECTION LEAK SWITCH S7263, PER MM 36-20-02. OPERATIONS CHECK GOOD.Dec 31, 2020 · N605KS · Emb EMB145LR · Pneumatic Indicating SystemSDR SIMA20201104001Cradle · brokenFLIGHT ATTENDANT FORWARD EMERGENCY FLASH LIGHT INOPERABLE. MEL 2553-AUTH NR 110047-C. C/A: FOUND F/A'S FWD EMERGENCY FLASH LIGHT HOLDER BROKEN. R & R F/A'S FLASH LIGHT HOLDER. OPERATIONS CHECKED GOOD, IAW AMM 33-50-16. MEL ITEM RESTORED.Nov 4, 2020 · N605KS · Emb EMB145LR · Emergency EquipmentSDR SIMA20200922002Lamp · inoperativeFWD RT EXTERIOR EMERGENCY LIGHT INOP. C/A: R&R EXTERNAL EMERGENCY LIGHT LAMP, IAW EMB 145 AMM 33-50-10. OPS CHECK GOOD, IAW EMB 145 AMM 33-50-00.Sep 22, 2020 · N605KS · Emb EMB145LR · Emergency LightingSDR SIMA202005042001Sign · unsecureEMERGENCY EXIT SIGN ON CEILING NEXT TO THE GALLEY IS FALLEN DOWN AND HANGING BY WIRES-C/A-SECURED EXIT SIGN IN PLACE, PERFORMED OPS CHECK. IAW AMM 33-50-00. OPS CHECK GOODMay 2, 2020 · N605KS · Emb EMB145LR · Emergency LightingSDR SIMA2020031312003Light · inoperativeMAIN DOOR EXTERNAL EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED MAIN DOOR EXTERNAL EMERGENCY LIGHT IAW AMM TASK 33-50-10-000-801-A AND 33-50-10-400-801-A. OPC GOOD. END.Mar 12, 2020 · N605KS · Emb EMB145LR · Emergency LightingSDR SIMA202002141002Charger · failedEMERGENCY LIGHT AT LH EMERGENCY DOOR IS INOP-C/A-RAR BATTERY POWER SUPPY #3 IAW 33-50-04 AND REMOVED AND REPLACED LH EMERGENCY DOOR EXIT IDENTIFIER SIGN IAW 33-50-13 OPERATIONAL CHECK GOOD. EMERGENCY LIGHTING BATTERY P/N 2013-1ASMI S/N 73057Feb 11, 2020 · N605KS · Emb EMB145LR · Emergency LightingSDR SIMA202001298003Skin · dentedDURING MBV INSPEECTION, QC FOUND A DENT BETWEEN FRAMES 4-5, STRINGERS 11R-14R-C/A-REPAIRED DENT BETWEEN FRAMES 4-5 AND STRINGERS 11R-14R IAW ERS-EM-53MR- 4022.Jan 28, 2020 · N605KS · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA202001276004Profile · corrodedDURING MBV INSPECTION, QC FOUND CORROSION ON THE PAX DOOR LOWER NUT PLATE HOLE.-C/A-REPAIRED CORROSION ON PAX DOOR LOWER NUT PLATE HOLE IAW EMB 145 SRM 52-10-02 AND ETN-EM-52-041 STEP 2. (REPAIR MATERIAL: DOUBLER 2024T3, 0.040")Jan 26, 2020 · N605KS · Emb EMB145LR · Passenger/Crew DoorsSDR SIMA202001275004Floor Support · corrodedDURING MBV INSPECTION, QC FOUND THE GALLEY LH FLOOR BEAM CORRODED AT CARBON CROSS MEMBER AT FR 20.-C/A-REPAIRED GALLEY LH FLOOR BEAM AT CARBON CROSS MEMBER AT FR 20 IAW EMB 145 SRM 53-00-10RE ITEM 2. (REPAIR MATERIALS: EXTERNAL ANGLE 2024T3 0.050", FILLER 2024Jan 25, 2020 · N605KS · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA202001273003Channel · corrodedDURING MBV INSPECTION, QC FOUND THE SERVICE DOOR CENTER SILL CORRODED AT PREVIOUS BLENDED AREAS.-C/A-REMOVED AND REPLACED SERVICE DOOR CENTER SILL IAW EMB 145 SRM 51-40-02.Jan 23, 2020 · N605KS · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA202001272006Web · gougedDURING MBV INSPECTION, QC FOUND 2 PREVIOUS REPAIR DOUBLERS ON CARGO DOOR INNER SKIN WEB WITH GOUGES-C/A-REMOVED AND REPLACED 2 PREVIOUS REPAIR DOUBLERS ON CARGO DOOR INNER SKIN WEB IAW EMB 145 SRM 52-30-01-RE ITEM #12. (REPAIR MATERIAL: DOUBLER 2024T3 0.050)Jan 22, 2020 · N605KS · Emb EMB145LR · Cargo/Baggage DoorsSDR SIMA202001272005Skin · crackedDURING MBV INSPECTION, QC FOUND THE CARGO DOOR HANDLE CUTOUT CRACKED AT AFT UPPER END.-C/A-CUT OUT DAMAGE AND INSTALLED FILLER AND DOUBLER TO CARGO DOOR HANDLE CUTOUT IAW ERS-EM-52MR-1052. (REPAIR MATERIAL: 2024-T3, 0.050)Jan 22, 2020 · N605KS · Emb EMB145LR · Cargo/Baggage DoorsSDR SIMA202001272004Profile · corrodedDURING MBV INSPECTION, QC FOUND THE CARGO DOOR LOWER PROFILE NUT PLATE HOLES CORRODED.-C/A-REMOVED AND REPLACED CARGO DOOR LOWER PROFILE IAW EMB 145 SRM 51-40-02.Jan 22, 2020 · N605KS · Emb EMB145LR · Cargo/Baggage DoorsSDR SIMA202001272007Beam · crackedDURING MBV INSPECTION, QC FOUND THE CARGO DOOR INNER BEAM ON VB4 BETWEEN HB3 AND HB4 CRACKED.-C/A-REMOVED AND REPLACED CARGO DOOR INNER BEAM ON VB4 BETWEEN HB3 AND HB4 IAW EMB 145 SRM 51-40-02 AND ERS-EM-5200-1051. (P/N INSTALLED: 145-25939-601)Jan 22, 2020 · N605KS · Emb EMB145LR · Cargo/Baggage DoorsSDR SIMA2020021131010Light · damaged8EA FLOOR PROXIMITY LIGHT PANELS DAMAGED-C/A-COMPLETE:REMOVED AND REPLACED ALL FLOOR PROXIMITY LIGHT PANELS IAW EMB 145 AMM 33-50-12.Dec 31, 2019 · N605KS · Emb EMB145LR · Emergency LightingSDR SIMA2020021131006Light · damaged#2, #4, #6, #7, AND #8 FLOOR PROXIMITY LIGHT STRIPS DAMAGED-C/A-COMPLETE:REMOVED AND REPLACED #2, #4 , #6, #7, AND #8 FLOOR PROX LIGHT STRIPS IAW EMB-145 AMM 33-50-12.Dec 31, 2019 · N605KS · Emb EMB145LR · Emergency LightingSDR SIMA2020021123107Light · brokenRH CABIN FLOOR EMERGENCY LIGHT STRIPS BROKEN (5 EA)-C/A-COMPLETE:REMOVED AND REPLACED 5 RH FLOOR EMERGNCY LIGHT STRIPS AS REQUIRED.Dec 31, 2019 · N605KS · Emb EMB145LR · Emergency LightingSDR SIMA2020021131008Light · inoperativeEMERGENCY LIGHT UNDER PANEL 233BLC AND COCKPIT STEP UP PANEL INOP-C/A-COMPLETE:REMOVED AND REPLACED WARDROBE EMERGENCY LIGHTS DC/AC INVERTER IAW EMB 145 AMM 33-50-11. OPC GOOD.Dec 31, 2019 · N605KS · Emb EMB145LR · Emergency LightingSDR SIMA2020021123009Light · brokenLH ANGLE EMERGENCY LIGHT STRIP FOR PANEL 231FF IS BROKEN-C/A-COMPLETE:REMOVED AND REPLACED LH ANGLE EMERGECNY LIGHT STRIP FOR PANEL 231FF IAW EMB 145 AMM 33-50-12.Dec 31, 2019 · N605KS · Emb EMB145LR · Emergency LightingSDR SIMA20191102001Acm · failedAT CRUISE FL 240 FA REPORTED PASSENGERS AT SEAT 11 B/C WERE REPORTING NOISES COMINF FROM LOWER RIGHT SIDE FOLLOWED BY CABIN SMOKE MERGENCY WAS DECLARED AND EMERGENCY PROCEDURES COMPLIED WITH DURING DESCENT SMOKE STOPPED IN CABIN LANDED SAFETY SAFELY IN CHS OVNov 2, 2019 · N605KS · Emb EMB145LR · Cabin Cooling SystemSDR SIMA20191101002Valve · failed#1 PACK OVLD AND #1 PACK VALVE FAIL IN FLIGHT CLIMBING THROUGH FL340. QRH PROCEDURE FOLLOWED.-C/A-FLIGHT CREW PLACARDED #1 PACK. MEL# 21-28 AUTH# 110034D-C MOC# 730088. CHANGED MEL 21-28 TO MEL 21-29 BOTH PACKS INOP AUTH 110034DM-C M PROCEDURES C/W AUTH 110034Nov 1, 2019 · N605KS · Emb EMB145LR · Cabin Cooling SystemSDR SIMA20191031003Light · inoperativeFWD MOST CENTER CEILING EMERGENCY LIGHT IN CABIN INOP-C/A-REMOVED AND REPLACED FWD MOST CENTER CEILING EMERGENCY LIGHT IN CABIN IAW AMM TASK 33-50-08-000-801-A AND 33-50-08-400-801-A. OPC GOOD. END.Oct 31, 2019 · N605KS · Emb EMB145LR · Emergency LightingSDR SIMA201910287001Duct · inoperativePACK 1 OVRLD MESSAGE IN FLIGHT COMPLETED QRH, PAX NOTED NOISE & SMELL IN CABIN-C/A-REMOVED AND REPLACED DUCT IAW AMM TASK 21-51-01.Oct 27, 2019 · N605KS · Emb EMB145LR · Air Distribution SystemSDR SIMA20190908002Light · inoperativeMAIN DOOR EXTERIOR EMERGENCY LIGHT INOP. C/A-REMOVED AND REPLACED MAIN DOOR EXTERIOR EMERGENCY LIGHT LAMP IAW AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. OPS CHECK GOOD.Sep 8, 2019 · N605KS · Emb EMB145LR · Emergency LightingSDR SIMA20190828001Fan · failedSTRONG FOUL ODOR COMING FROM RUNNING THE PACKS-C/A-FOUND STRONG ODOR COMING FROM GASPERFAN (PAX VENTS AND COCKPIT VENTS) DEFERED GASPER FAN AS PER MEL 21-4 (M) PROCEDURES C/W. REPLACED GASPER FAN IAW EMB 145 AMM 21-23-03 NORMAL OPERATION NOTED MEL 21-4 RESTOREAug 28, 2019 · N605KS · Emb EMB145LR · Air Distribution FanSDR SIMA20190725001Spar · crackedCRACK IN AFT SPAR 6.1 INCHES LONG LT IB FLAP. C/A-REPAIRED IAW ERS-EM-57MR-1140 PART A.Jul 25, 2019 · N605KS · Emb EMB145LR · Trailing Edge FlapsSDR SIMA20190508002Warning System · false activationBLEED 2 LEAK IN CLIMBOUT. C/A-PERFORMED LEAK CHECK OF NR 2 BLEED SYSTEM IAW MM 36-00-00 AND ETNEM-36-063. OPS CK AND LEAK CHECK GOOD,May 8, 2019 · N605KS · Emb EMB145LR · Pneumatic Indicating SystemSDR SIMA20190401101Warning Light · false indicationPACK 1 OVERLOAD DURING T/O ROLL. T/S PACK 1 OVERLOAD PER FIM TASK EMB145 FIM 21-51-00-810-801A STEPS 1-3 FOUND TO BE A TRANSITORY CONDITION OF THE A/C SYSTEM. PERFORMED OP CK OF THE A/C SYSTEM IAW EMB 145AMM 21-51-00 NO DEFECTS NOTEDMar 29, 2019 · N605KS · Emb EMB145LR · Cabin Cooling SystemSDR SIMA20190310004Skin · crackedRT FUSELAGE SKIN CRACKED AT FR 12A STR 6R. C/A-PERFORMED PERMANENT REPAIR RT FUSELAGE SKIN CRACKED AT FR 12A STR 6R IAW ERS-EM-53MR-3701.Mar 10, 2019 · N605KS · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20190310003Skin · crackedRT WINDSHIELD LATERAL POST UPPER SKIN CRACKED BETWEEN WINDSHIELD AND DV WINDOW OPENING. C/A-PERFORMED PERMANENT REPAIR ON RT WINDSHIELD LATERAL POST UPPER SKIN CRACKED BETWEEN WINDSHIELD AND DV WINDOW OPENING IAW ERS-EM-53MR-3701.Mar 10, 2019 · N605KS · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20190309002Connector · brokenEMERGENCY FLOOR LIGHT STRIP AT PANEL 241BF HAS BROKEN CONNECTORS. C/A-REPLACED BROKEN CONNECTORS ON EMERGENCY FLOOR LIGHT STRIP AT 241BF IAW SWPM 20-21-00 AND 20-00-03. CONNECTOR P/N M39029/32-248.Mar 9, 2019 · N605KS · Emb EMB145LR · Light System WiringSDR SIMA20190307005Skin · dentedFWD FUSELAGE 1 RT SKIN HAS DENT AT FR 4 BETWEEN STR 4R-6R. C/A-PERFORMED PERMANENT REPAIR ON FWD FUSELAGE 1 RT SKIN AT FR 4 AND STR 4R-6R IAW ERS-EM-53MR-3690.Mar 7, 2019 · N605KS · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20190307003Frame · dentedFRAME 4 BENT BETWEEN STR 4R AND 6R. C/A-PERFORMED PERMANENT REPAIR ON FR 4 AND STR 4R-6R IAW ERS-EM-53MR-3690.Mar 7, 2019 · N605KS · Emb EMB145LR · Fuselage Main, FrameSDR SIMA20190303006Skin · dentedDENT FWD OF CARGO DOOR BUMPER. C/A-PERFORMED PERMANENT REPAIR OF THE DENT FWD OF CARGO DOOR BUMBER IAW SRM 53-31-01.Mar 3, 2019 · N605KS · Emb EMB145LR · Fuselage Main, Plate/SkinSDR SIMA20190303005Support · crackedRT OMEGA BEAM INBD SUPPORT CRACKED AT FWD END OF REPLACEMENT PIECE BETWEEN FR47 AND FR48. C/A-REMOVED AND REPLACED RT OMEGA BEAM IAW SRM 53-23-02.Mar 3, 2019 · N605KS · Emb EMB145LR · Fuselage Miscellaneous StructureSDR SIMA20190226004Shunt · corrodedCORROSION ON APU CONNECTING BAR MOUNTING SUFACE SHUNT. C/A-PERFORMED PERMANENT REPAIR ON APU CONNECTING BAR SHUNT AND FR 80 IAW ERS-EM-53MR-3675.Feb 26, 2019 · N605KS · Emb EMB145LR · Fuselage Main, Attach Fittings
Back to N605KS