N616AE
Service difficulty reports · 184
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N616AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N616AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA20221025002Clamp · unsecureA/I BACK TO ORD DUE TO BLEED 1 LEAK DURING FLIGHT. EMERGENCY WAS DECLARED BUT WAS NOT OVERWEIGHT. FLT CHG EQP AND CONTINUED-C/A-PERFORMED VISUAL AND LEAK INSPECTION OF DUCT AIR BLEED LINES OF SYSTEM 1 IAW EMB 145 AMM TASK 36-11-09. RE-TORQUED V-BAND CLAMPS AT SDR SIMA20220717002Flashlight Assy · brokenFORWARD FLIGHT ATTENDANT FLASH LIGHT NOT CHARGING/HOLDER BROKEN-C/A-REMOVED AND REPLACED FORWARD FLIGHT ATTENDANT FLASH LIGHT ASSEMBLY IAW AMM 33-50-16. OPERATIONAL CHECK GOOD.SDR SIMA20220519002None · noneE1 FIREDET FAIL IN CRUISE-C/A-PERFORMED OPERATIONAL CHECK OF E1 FIRE DET SYS OPERATION CHECK GOOD AS PER AMM 26-10-00 NO DEFECTS NOTEDSDR SIMA20220513003None · noneAFTER REACHING CRUISE " E1 FIRE DET FAIL" CAME ON FOR APPROX 5 MINS. ENG INDICATIONS NORMAL. NO OTHER MSGS. OR TURBULENCE.-C/A-INSP. AND FOUND FIRE LOOP HITTING ENG. AT 6 DEFFERENT POINTS. REPOSITIONED LOOP AS REQUIRED. OPS CK OF FIRE LOOP IAW EMB 145 MM 26-10SDR SIMA20220323001None · noneE1 FIREDET FAIL CAME ON AND OFF 3 TIMES DURING FLIGHT. ALL OTHER INDICATIONS WERE NORMAL. "TRANSFERRED TO NRWC 616-DFW-04848"-C/A-RAR ENG1 FIRE DETECTOR SENSING ELEMENT IAW EMB145 AMM 26-11-01. OPERATIONAL CHECK GOOD. NO DEFECT NOTED. SEE NRWC# 616-DFW-04848 FSDR SIMA20220318001None · noneAFT EMERGENCY FLASHLIGHT INOP MEL 2532 - AUTH# 03-253M-C-C/A-RAR AFT FLASHLIGHT ASSEMBLY IAW EMB AMM 33-50-16-000-801-A AND 33-50-16-400-801-A. OPC GOOD. MEL RESTORED.SDR SIMA20220318002None · noneSERVICE DOOR EMERGENCY LIGHT INOP AND FOUND 2 BROKEN WIRES ON SERVICE DOOR EMERGENCY LIGHT-C/A-RAR SPLICES SP7377 AND SP7376 IAW SWPM-2430 20-21-00. OPS CHECK GOOD. END.SDR SIMA20220315001Flashlight · inoperativeAFT EMERGENCY FLASHLIGHT INOP-C/A-FLIGHT CREW PLACARDED AFT EMERGENCY FLASHLIGHT M PROCEDURES C/W MEL 25-32 AUTH 030253M-C MOC 607038SDR SIMA20220217001None · noneFLIGHT ATTENDANT FORWARD EMEERGENCY FLASHLIGHT INOP-C/A-REPLACED FWD FA EMERGENCY FLASHLIGHT OPS CHECK GOOD PE 25-60-11SDR SIMA20220124002None · noneEMERGENCY LIGHT ON SERVICE DOOR NOT ILLUMINATING AND WIRE BROKE OFF AT BULB.-C/A-REMOVED AND REPLACED SERVICE DOOR EXTERNAL EMERGENCY LIGHT ASSY IAW EMB 145 AMM 33-50-10. OP CHECKED GOOD.SDR SIMA20211119002None · noneFWD FA EMERGENCYFLASHLIGHT IS MISSING-C/A-RAR FWD FA EMERGENCY FLASHLIGHT. IAW E145 AMM 33-50-16SDR SIMA20211103003None · noneAFT EMERGENCY FLASHLIGHT MISSING MEL 25-32. AUTH #110026M-C. REF LOG PG 4676473/1.-C/A-RAR AFT EMEREGENCY FLASHLIGHT ASSY ON TOILET FWD PARTITION, BEHIND LAST DOUBLE SEAT IAW EMB 145 AMM 33-50-16. OPC GOOD. MEL ITEM RESTORED. (M) PROCEDURES REVERSED.SDR SIMA20210416003Warning Message · false activationBLEED 1 LEAK EICAS MSG IN AIR. HAPPENED AFTER OR DIRECTLY AFTER ENTERING ICING DID NOT DECLARE EMERGENCY-C/A-PERFORMED DUCT LINE INSPECTION AND CHECK IAW EMB 145 36-11-09 AND PERFORMED ENGINE BLEED VALVE OPERATIONAL CHECK IAW 36-11-05. OPS CHECK GOODSDR SIMA20210226002Flashlight · missingREAR CABIN EMERGENCY FLASHLIGHT MISSING-C/A-REPLACED CABIN CABIN FLASHLIGHT IAW ETN-EM-33-034 OPC GOOD NO FUTHER DEFECTS NOTEDSDR SIMA20210221003Battery Pack · inoperativeLEFT FWD WING TO FUSELAGE FAIRING EMERGENCY LIGHT INOPERATIVE. C/A-REMOVED AND REPLACED NR 1 EMERGENCY BATTERY AND NR 1 EMERGENCY CHARGER ASSY IAW WORK CARD 33-700-19. OPERATIONAL CHECK GOOD. NO DISCREPANCIES NOTED.SDR SIMA20210106001Lamp · inoperativeRT OVERWING EMERGENCY LIGHT INOPERABLE. C/A: R & R RT OVERWING EMERGENCY LIGHT LAMP, IAW EMB AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. OPERATIONS CHECK GOOD.SDR SIMA20200825001Roller · lack of lubeMAIN CABIN DOOR WOULDN'T OPEN FROM THE INSIDE.-C/A-LUB. THE MAIN DOOR FRAME ROLLERS AS REQUIRED.OPS. CHECK GOOD.NO DEFECTS NOTED AT THIS TIME.SDR SIMA202005197008Door Frame · corrodedCARGO DOOR FWD SIDE EDGE NUTPLATE HOLE CORRODED OUT OF LIMITS-C/A-REPAIRED CARGO DOOR FWD FRAME CENTER HOLE IAW EMB 145 SRM 52-30-04RESDR SIMA202005187004Door Sill · corrodedSERVICE DOOR LOWER CENTER FLOOR SILL CORRODED-C/A-REPAIRED MIDDLE AND FWD NUTPLATE HOLES OF SERVICE DOOR CENTER SILL, IAW EMB 145 SRM 53-21-02.SDR SIMA202005187003Door Frame · corrodedCARGO DOOR LWR SIDE EDGE 4 NUTPLATE HOLES CORRODED-C/A-REMOVED AND REPLACED CARGO DOOR LWR INBD FRAME IAW EMB 145 SRM 51-40-02SDR SIMA202005187007Door Frame · gougedCARGO DOOR LWR OTBD FRAME FWD CORNER GOUGED-C/A-REMOVED AND REPLACED CARGO DOOR OTBD FRAME IAW EMB 145 SRM 51-40-02SDR SIMA202005187006Profile · bentCARGO DOOR LOWER PROFILE IS BENT NEAR FORWARD ROLLER-C/A-REMOVED AND REPLACED CARGO DOOR LOWER PROFILE IAW EMB 145 SRM 51-40-02SDR SIMA202005187005Frame · dentedFRAME 72 BETWEEN STRINGERS 15R AND 17R HAS A DENT-C/A-REMOVED AND REPLACED FRAME 72 IAW EMB 145 SRM 51-40-02SDR SIMA202001221004Connector · dirtyMAIN DOOR EMERGENCY LIGHT INOP"TRANSFERRED TO NRWC 616-ORD-03398"-C/A-DEFERRED PER MEL 33-29. CLEANED MAIN DOOR EMERGENCY LIGHT ASSY ELECTRICAL CONNECTIONS IAW SWPM 20-50-00. OPS CHECK GOOD IAW EMB AMM 33-50-00. MEL RESTORED.SDR SIMA201911086001Lamp · inoperativeROW 12 B/C OVERHEAD EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED 12 B/C OVERHEAD EMERGENCY LIGHT LAMP IAW EMB 145 AMM 33-50-07-04. OPS CHECK GOOD.SDR SIMA201910076001Smoke Detector · false activationON TAXI RECIEVED BAGG SMOKE INDICATION. REMOVED AND REPLACED FWD CARGO SMOKE DETECTOR IAW AMM 26-15-01 OPC GOODSDR SIMA201908231007Engine · failedPOSSIBLE APU FIRE, SMOKE COMING FROM APU INTAKE. REMOVED AND REPLACED APU IAW W/C 49-800-05. OPS CHECK GOOD LEAK CHECK GOOD.SDR SIMA20190709003Control Valve · failedON FINAL APPROCH WHEN LANDING REAR EXTENDED BRAKE DEGRADED MASTER CAUTION INDICATION APPEARED DID GO AROUND CAUTION DISAPPEARED WHEN LANDING GEAR RETRACTED + REAPPEARED ON 2ND LANDING NO BRAKING ACTION DEGRADATION ON LANDING. CAUTION DID NOT DISAPPEAR "TRANSFESDR SIMA20190524002Valve · failedPAC 1 VALVE FAIL IN FLIGHT; PAC 1 & 2 OVLD IN FLIGHT; BURNING SMELL IN COCKPIT. SMELLED LIKE BURNT PLASTIC. NO COMPLAINTS OF BURNING SMELL IN CABIN. NO SMOKE OBSERVED IN COCKPIT. C/A-REMOVED AND REPLACED #1 PACK VALVE IAW AMM 21-51-01. PERFORMED OPERATIONAL TESDR SIMA20190517002Cradle · brokenAFT CABIN FLASHLIGHT CRADLE BROKEN. C/A-REMOVED AND REPLACED AFT FLASHLIGHT CRADLE IAW AMM TASK 33-50-16-000-801-A AND 33-50-16-400-801-A.SDR SIMA20190512002Light · inoperativeFLOOR EMERGENCY LIGHT STRIP AT ROWS 6A/7A INOP. C/A-REMOVED AND REPLACED EMERGENCY LIGHT STRIP IAW AMM 33-50-12 OPS TEST GOOD.SDR SIMA20190503001Battery · dischargedDURING PS-2 FOUND LH EXT EMERGENCY LIGHT BURNED OUT. C/A-REMOVED AND REPLACED LT FWD EXT EMERGENCY LIGHT ASSY IAW 33-50-10. EMERGENCY LIGHTS OPS CHECK GOOD IAW AMM 33-50-00. EMERGENCY LIGHTING BATTERY NR 4 P/N 2013-1A S/N 103874 AND 79164, NR 1 109569. BATTERSDR SIMA20181106004Connector · missingTHE EMERGENCY LIGHT STRIP CONNECTOR THAT CONNECTS TO THE EMERGENCY LIGHT STRIP AT FLOOR PANEL 251BF HAS MISSING CONNECTOR. INSTALLED SERVICEABLE CONNECTOR ON EMERGENCY LIGHT STRIP AT FLOOR PANEL 251BF IAW SWPM 20-21-00.SDR RAIA20180829004Fuse · blownNR 1 EMERGENGY LIGHT BATTERY HAD LOW VOLTAGE. R & R THE BATTERY, OPS CHECKED GOOD. THE BATTERY HAD A BLOWN FUSE.SDR RAIA201802010001Valve · defectiveA/C WOULD NOT PRESSURIZE AFTER TAKE OFF. R & R GROUND CONNECTION VALVE. PERFORMED OPS CHK OF PRESSURIZATION OPS CHECK GOOD.SDR RAIA201801310001Valve · defectiveUNABLE TO PRESSURIZE AIRCRAFT AFTER TAKE OFF. R&R GROUND CONNECTION VALVE PERFORMED OPS CHECK OF PRESSURIZATION, OPS CHECK GOOD.SDR RAIA201801220002Windshield · crackedF/O WINDSHIELD OUTER PLY SHATTERED. R & R F/O WINDSHIELD OPS CHECK GOOD.SDR RAIA201711190001Connector · dirtyUNCOMMANDED STEERING SWERVED ON GROUND. REMOVED AND CLEANED FEEDBBACK POT CONNECTOR. RECONNECTED AND HAD CREW PERFORM TAXI OPS CHECK OF STEERING. NO DEFECT NOTED.SDR RAIA201711110002Skin · crackedRIGHT FUSELAGE EXTERIOR SKIN AT FR 75 HAS 3 POSSIBLE CRACKS - MARKED. PERFORMED REPAIR ON RH FUSELAGE EXTERIOR SKIN AT FR 75.SDR RAIA201605240001Line · failedON TAKEOFF, RECEIVED A LANDING GEAR DISAGREE MESSAGE AND HYD SYS 1 FAIL AND HYDRAULIC SYS 1 LOW QTY. INSPECTED AND FOUND LT MLG ACTUATOR HYDRAULIC LINE FAILED. R & R HYD LINE PERFORMED OPS CHECK OF GEAR. OPS AND LEAK CHECK GOOD.SDR RAIA201605090001Button · inoperativeTHRUST RATING PANEL CLIMB BUTTON WOULD NOT ENGAGE. R & R THRUST RATING PBA. OPS CHECK GOOD.SDR RAIA201506250003Light · inoperativeSERVICE DOOR, NR 2 SHROUDED EMERGENCY LIGHT IS INOPERATIVE. MAINTENANCE REPLACED THE LIGHT, OPS CHECKED GOOD.SDR RAIA201506250002Light · inoperativeCOCKPIT STEP EXIT IDENTIFIER LIGHT NR 9 DOES NOT ILLUMINATE. MAINTENANCE REPLACED LIGHT, OPS CHECKED GOOD.SDR RAIA201506250001Light · out of positionMAIN DOOR EMERGENCY FLOOD LIGHT NR 13 SWITCHED WITH COURTESY LIGHT. MAINTENANCE SWITCHED LIGHTS TO THE CORRECT POSITION, OPS CHECK GOOD.SDR SIMA20150519008Battery · dischargedFLOOR PROXIMITY EMER EXIT LIGHTS FROM EMER EXIT ROW TO THE FRONT DO NOT ILLUMINATE. OPERATED APU TO CHARGE EMER BATTERIES. TURNED ON EMER LIGHTS. PERFORMED OPERATIONS CHECK IAW AMM 33-50-00-700-801-A. OPERATIONS CHECKED GOOD.SDR SIMA20150519006Warning System · false activationFLAP LOW SPEED ADVISORY APPEARED ON EICAS DURING CLIMB OUT. REINSTALLED FLAP DRIVE MOTORS IN ORIGINAL LOCATIONS IAW AMM 27-53-01. PERFORMED TAKEOFF FLAPS OPERATIONS CHECK IAW AMM 27-53-00-700-802-A. OPERATIONS CHECKED GOOD. CYCLED FLAPS MULTIPLE TIMES & COSDR SIMA20150510001Doubler · corrodedLOWER RT PARTITION DOUBLER ON FRAME 61 IS CORRODED BEYOND LIMITS. COMPLETED REPAIR TO RT PARTITION DOUBLER ON FRAME 61 IAW ERS-EM-53MR-1291.SDR SIMA20150503002Bearing · dislodgedRUDDER 1 LOWER CONTROL ROD BEARING ON VERTICAL STAB RETAINER RING IS DISLODGED. R & R RUDDER 1 LOWER HINGE FITTING ASSEMBLY IAW SRM 51-40-02.SDR SIMA20150503003Hinge · ratchetingRUDDER 1 UPPER CONTROL ROD. BEARING ON VERTICAL STAB IS RACHETING. R & R RUDDER 1 UPPER CTR HINGE FITTING ASSEMBLY IAW SRM 51-40-02.SDR SIMA20150503001Hinge · damagedVERTICAL STAB TO RUDDER 1 LOWER HINGE SHACKLE HAS PLAY. INSTALLED NEW HINGE FITTING ASSEMBLY IAW SRM 51-40-02 & ERS-EM-5500-287.