N617AE
Service difficulty reports · 197
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N617AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N617AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR HNAA2022082500249Bolt · shearedON T/O ROLL, ENG REF A/I DISAGREE DISPLAYED. MESSAGE REMAINED ON TAXI IN ALONG WITH E2 A/I VLV FAIL DISPLAYED ON TAXI. DURING E2 A/I VLV DEACTIVATION LOCKING BOLT ON A/I VLV SHEARED OFF. R&R E2 A/I VLV IAW AMM 36-11-05. SEE NEXT SEQ THIS LP FOR NEW DISCREPANSDR HNAA2022081500248Proximity Sensor · malfunctionedAFTER ROTATION NLG WILL NOT RETRACT LG LEVER DISAGREE MESSAGE DISPLAYED ON EICAS ... CMC DISPLAYS 2 OCC OF LG UP/DN PROX SW/LGUE FAIL & LG NOSE UP PROX SW FAIL.T/S W/FIM 32-61-00-810-802-A DIA 001.COMPLETED BLKS 1 THRU 5 ONLY FINDING LOOSE C/P ON PROX SW.R/R SDR HNAA2022041900166Proximity Switch · failedAFTER GEAR RETRACTION LOUD NOISE HEARD FROM NOSE BAY AREA. C/W QRH SPEED BELOW 250 KNOTS. GEAR INDICATED UP AS NORMAL. HYD PRESSURE NORMAL. TROUBLESHOOTING, R & R NLG DOOR SOLENOID VALVE WITH SERVICEABLE VALVE. WORK DONE IN REF TO AMM 32-33-02. DID NOT FIX.SDR HNAA2021081900387Bleed Valve · faultedBLD 1 VALVE CLOSED MSG IN FLT AND WOULD NOT CLEAR UNTIL STARTED APPROACH. R & R BLD 1 VLV REGULATOR IAW AMM 36-11-05.NO FIX. CONTINUE T/S. R/R PANEL ASSY AIR COND / PNEUMATIC IAW AMM 20-13-10 OPS CHECK GOOD OK FOR SERVICE.SDR HNAA2021061400261Solenoid Valve · faultedLOUD AIR NOISE AND VIBERATION FROM NLG AREA AFTER RETRATION OF GEAR. R&R NLG DOOR SOLENOID VALVE REF 32-33-02. LEAKS AND OP CKS GOOD OK FOR SERVICE.SDR HNAA2021010500005Clamp · looseICE CONDDITION. A/I INOPERABLE AND WING A/I FAIL MESSAGES ON EICAS WITH WING 1 AND 2 VALVE FAIL AND WING 2 A/I LEAK MESSAGES ON CMC. FOUND SERVERAL LOOSE CLAMPS IN NR 2 PACK AREA. TIGHTENED CLAMPS AS REQ. OPERATIONS AND LEAK CHECKED WITH CREW, IAW AMM 30-0SDR HNAA2020090100250Connector · damagedAFTER TAKEOFF, GEAR LEVER SELECTED UP, LANDING GEAR STAYED DOWN WITH AMBER INDICATIONS. CREW C/W ARH LANDING GEAR STAYED DOWN. TROUBLESHOT IAW AMM 32-32-00-700-802-A STEPS J2(F) AND J2(G) FAILED, 2.5 VDC WAS INTERMITTENTLY READING ON P0037 BETWEEN PINS A ANDSDR HNAA2020072700233Unknown · odorDURING TAKE OFF, AT 100KTS, A BURNING SMELL IN COCKPIT WAS NOTICED BY FO AND CAPT. REJECTED TAKE OFF. WITHIN 5 SECONDS BURNING SMELL DISSIPITATED. INSPECTED AND RAN BOTH ENGINES WITH BLEEDS ON AND OFF FOR 20 MINS. INSPECTED NOSE BAY COMPARTMENT NO DEFECTS SDR HNAA2020052310156Warning System · malfunctionedNO TAKE OFF CONFIG WARNING ON TAKE OFF. RERACKED AWU IAW AMM 31-51-01-04. OPS CHK GOOD. OKAY FOR SERVICE.SDR HNAA2020052210155Pressure Switch · failedNO TAKE OFF CONFIG WARNING ON TAKEOFF. RNR PARK BRAKE PRESS SW IAW AMM 32-44-07-04. OPS CHECK GOOD OKAY FOR SERVICE.SDR HNAA2020052310154Pressure Switch · failedPARKING BRAKE ON LIGHT PRESENTED INFLIGHT AND WILL NOT EXTINGUISH. RNR PARK BRAKE PRESS SWITCH IAW AMM 32-44-07-04. OPS CHECK GOOD OKAY FOR SERVICE.SDR HNAA2020051800150Inverter · inoperativeL/H EMERGENCY DOOR MAIN EXIT LIGHT INOP (EXIT IDENT SIGN). REMOVED AND REPLACED EXIT IDENT SIGN IAW AMM 33-50-13. NO FIX TROUBLE SHOOT PER FAULT ISOLATION MANUAL 33-50-0-810-804-A. REMOVED AND REPLACED INVERTER #4 IAW AMM 33-50-11 OPTS CHECK GOOD.SDR HNAA2019122700393Nut Plate · corrodedCORRODED NUTPLATE HOLES ON CARGO CUTOUT STRUCTURE LOWER CENTER SILL. R & R THE CARGO DOOR SILL IAW SRM 51-40-02.SDR HNAA20191227001Yoke · crackedLEFT ENGINE FWD LOWER YOKE HAS CRACK ON FWD LOWER CORNER. R & R LH FWD YOKE FITTING AND GUSSET PLATE IAW EO1-71-19-0565.SDR HNAA2019122700395Profile · corrodedCARGO DOOR LOWER I/B PROFILE CORRODED AROUND NUTPLATES....FIX:R&RD CARGO DOOR LWR INBD PROFILE IAW EMB145 SRM 51-40-02SDR HNAA2019122700392Nut Plate · corrodedCARGO DOOR WEB HAS 2 AREAS AROUND NUTPLATES CORRODED. REPAIRED IAW EMB SRM 52-30-01RE AND EO1-52-19-0557SDR HNAA2019122700397Skin · crackedCARGO DOOR SKIN WAS CRACKED AT THE AFT END OF THE HANDLE. INSTALLED A REPAIR DOUBLER AND FILLER IAW EO1-52-19-0555.SDR HNAA2019122700396Skin · gougedLH WING LEADING EDGE NR 1 EXTERIOR HAD ONE GOUGE. FABRICATED AND INSTALLED A REPAIR IAW SRM 51-20-01, AND EO1-57-19-0566.SDR HNAA2019111100351Warning Message · false activationPDIS 617 27-41 2119051 10NOV19 PHL CLOSE
MAIN PITCH TRIM INOP MSG DURING FLIGHT.
FACT 10NOV19 16:43 PHL
T/S IN REF TO FIM TASK 27-43-00, ELECTRICAL CHECKS G
OOD. OPS CHECK IN REF TO AMM 27-40-00. OPS CHECK GOO
SDR HNAA2018120500303Display · malfunctionedDIS 617 34-28 1723962 29NOV18 MHT CLOSE
SITTING AT GATE WITH ELECTRICAL POWER ON. EICAS SHUT DOWN FOLLOWED BY ELECTRICAL FUMES SMELT IN COCKPIT. NO C/BS POPPED.
HISTORY: NO
FACT 29NOV18 04:2SDR HNAA2018062600128Sign · inoperativeEMERGENCY SIGN INOPERATIVE BY SEAT 12A. R & R EMERGENCY SIGN. OPS CHECKED GOOD.SDR HNAA2018032600069A/C Pack · seizedDURING PUSHBACK STRONG RUBBER BURNING ODOR GENERATED, ODOR STOPPED ONCE PUSHBACK WAS COMPLETE. MX INSPECTED AND FOUND NR 1 PACK SEIZED. R &R THE NR 1 ACM IAW AMM 21-51-03. OPS CHECKED GOOD. LEAK CHECKED GOOD. OK FOR SERVICE.SDR HNAA2018032100064Duct · detachedWITH BOTH PACKS RUNNING ON APU, THE NR 2 PACK WAS SELECTED OFF AND NR 1 PACK MADE AN ABNORMAL NOISE, THE FLT DECK FILLED WITH SMOKE AND ODOR. INSPECTED, NO FUMES OR ODOR WITH THE NR 2 PACK. FOUND THE RECIRCULATION FAN DUCT OFF, REINSTALLED THE DUCT. OPS SDR HNAA2017092500328Light · inoperativeRIGHT EMERGENCY DOOR UPPER EXIT LIGHT IS INOPERATIVE. R & R THE LIGHT IAW AMM 33-50-14-000/400-801-A. OPS CHECKED GOOD. OK FOR SERVICE.SDR HNAA2017073100257Relay · damagedDURING INSPECTION OF RELAY K0058 & RELAY BASE XK0058, SAID RELAY AND BASE FAIL STEP-11IN FCD1-30-165-0276. FOUND DAMAGE AND BURNED PINS ON PITOT STATIC NR 3. BOTH RELAYS K0058, AND RELAY SOCKET XK0058 AND PINS WERE R & R.SDR SIMA20170615015Wire · brokenLEFT NR 6 EMERGENCY LIGHT STRIP HAS BROKEN WIRES. REMOVED AND REPLACED THE LIGHT IAW AMM 33-50-12.SDR SIMA20170615010Holder · crackedNR 1 LT FLOOR EMERGENCY LIGHT STRIP HOLDER CRACKED. REMOVED AND REPLACED THE EMERGENCY LIGHT HOLDER IAW AMM 33-50-12.SDR SIMA20170615016Light · crackedNR 1 RT EMERGENCY LIGHT STRIP CRACKED. REMOVED AND REPLACED THE EMERGENCY LIGHT IAW AMM 33-50-12.SDR SIMA20170615011Light · crackedLEFT NR 6 PROXIMITY LIGHT EXTRUSION CRACKED. REMOVED AND REPLACED THE LIGHT IAW AMM 33-50-12.SDR SIMA20170615014Holder · crackedNR 2 LT FLOOR LIGHT STRIP HOLDER CRACKED. REMOVED AND REPLACED THE NR 2 EMERGENCY LIGHT HOLDER IAW AMM 33-50-12.SDR SIMA20170615013Skin · bentRIGHT EMERGENCY EXIT EXTERNAL SKIN UPPER EDGE BENT. CONTOURED BENDED IAW SRM 51-10-08.SDR SIMA20170615012Stiffener · crackedFOUND APU COWLING PROFILE 17D CRACKED APPROX 28 INCHES FROM FWD EDGE. COMPLETE:REPAIRED THE APU COWLING INTERNAL STIFFENER IAW SRM 53-32-17.SDR SIMA20170615009Bracket · corrodedCORROSION ON RT EMERGENCY ESCAPE HATCH INTERNAL LOWER BRACKET. REMOVED AND REPLACED RT EMERGENCY EXIT LOWER BRACKET IAW SRM 51-40-02.SDR SIMA20170615008Bracket · crackedBRACKET IS CRACKED ON INTERNAL FUSELAGE AT FRAME 20 STRINGERS 3L. REMOVED AND REPLACED BRACKET ON INTERNAL FUSELAGE AT FRAME 20 STRINGERS 3L IAW SRM 51-40-02.SDR SIMA20170615007Door Sill · corrodedCARGO DOOR CENTER SILL IS CORRODED ON FWD END. REMOVED AND REPLACED CARGO DOOR CENTER SILL WITH NEW SERVICEABLE SILL IAW SRM 51-40-02.SDR SIMA20170615006Connector · disconnectedEMERGENCY EXIT LIGHT IN 233ALC IS INOP. UPON FURTHER INVESTIGATION FOUND ELECTRICAL CONNECTOR ABOVE MAIN DOOR REGION CEILING PANEL DISCONNECTED. RECONNECTED ELECTRICAL CONNECTOR IAW AMM 25-22-04. EMERGENCY EXIT LIGHT IN 233ALC OPERATIONAL CHECKS GOOD IAW AMM 3SDR SIMA20170615005Connector · disconnectedLT COCKPIT BULKHEAD EMERGENCY EXIT LIGHT INOP. UPON FURTHER INVESTIGATION FOUND ELECTRICAL CONNECTOR ABOVE MAIN DOOR REGION CEILING PANEL DISCONNECTED. RECONNECTED ELECTRICAL CONNECTOR IAW AMM 25-22-04. EMERGENCY EXIT LIGHT IN LT COCKPIT BULKHEAD OPERATIONAL CSDR SIMA20170611001Connector · disconnectedLEFT FWD OVERWING EMERGENCY LIGHT INOPERATIVE. FOUND EMERGENCY LIGHT BATTERY CHARGER NR 1 CONNECTOR REMOVED FROM CHARGER. SECURED THE CONNECTOR, OPS CHECKED GOOD IAW AMM 33-50-00.SDR SIMA20170601001Light · inoperativeEMERGENCY EXIT LIGHT INOPERATIVE. REMOVED AND REPLACED THE EXIT LIGHT IAW AMM 33-50-14, OPS CHECKED GOOD.SDR SIMA20170419001Warning Message · illuminatedHIGH SPEED ABORT FOR MASTER WARNING SPS 1-2 INOPERATIVE, AT 120 KTS. NORMAL BRAKING AND NO OVERHEATING ON BRAKES. -TIGHTENED SPC MOUNTING TRAY KNOBS AS NEEDED. PERFORMED OPS CHECKS IAW AMM 27-36-00. OPS CHECKS GOOD.SDR SIMA20161023001Light · inoperativeEMERGENCY LIGHTS STRIP INOPERATIVE SEATS 7-11.SDR SIMA20161023002Charger · inoperativeEMERGENCY LIGHTS INOPERATIVE AT SEATS 7-11. REMOVED AND REPLACED THE NR 3 EMERGENCY POWER SUPPLY AND BATTERY PACK IAW AMM 33-50-04. OPS CHECKED GOOD.SDR SIMA20160509003Light · inoperativeLEFT EMER LIGHT FWD OF WING INOPERATIVE. R & R EMER LIGHT FWD OF WING IAW AMM 33-50-10-000-801 & 33-50-10-400-801. OPERATIONS CHECKED GOOD.SDR SIMA20160331001Rod · defectiveMAIN CABIN DOOR WILL NOT OPEN. DEPLANED VIA SERVICE DOOR. R&R ROD CONNECTED TO CAM ASSEMBLY FOR PAX DOOR FLAP ASSEMBLY IAW AMM 52-18-02. OPERATIONS CHECKED GOOD.SDR SIMA20160208003Stringer · dentedDENT & SCRATCH AT FRAME & STRINGER 8R WITH 1 MISS-DRILLED HOLE IN STRINGER 8R. PERFORMED PERMANENT REPAIR OF DENT, SCRATCH & MISS-DRILLED HOLE ON FRAME 75, STRINGER 8R IAW ERS-EM-53MR-1904.SDR SIMA20160205003Wire · brokenEXIT SIGN ON COCKPIT HAS A BROKEN WIRE. PERFORMED SPLICE REPAIR TO WIRE W762-8044-20 IAW SWPM 20-21-00.SDR SIMA20160205004Connector · missingEMERGENCY LIGHT STRIP NR 8 CONNECTOR AT FLOOR PANEL 261BF MISSING, ACFT SIDE. INSTALLED MISSING CONNECTORS SP9212 WIRE W192-8832-22 & SP9213 WIRE W192-8833-22 IAW SWPM 20-50-00. CONTACT PN M39029-32-248.SDR SIMA20160202004Skin · crackedLEFT UPPER FUSELAGE SKIN HAS 2 CRACKS. ONE ABOVE STRINGER 2L, & ONE BELOW STRINGER 2L. PERFORMED PERMANENT REPAIR OF LT UPPER SKIN AT FRAME 75 ABOVE & BELOW STRINGER 2L IAW ERS-EM-53MR-1902.SDR SIMA20160202002Wire · brokenLEFT NR 5 FLOOR PROXIMITY LIGHT STRIP HAS BROKEN WIRE AT BASE OF LIGHT. R & R NR 5 PROXIMITY LIGHT STRIP IAW AMM 33-50-12.SDR SIMA20160128004Support · corrodedLAVATORY WASTE BUCKET HAS CORROSION. FABRICATED & INSTALLED DOUBLER ON LAVATORY TOILET WASTES VLV SUPPORT IAW 145 SRM 53-31-02.
Back to N617AE