N638AE
Service difficulty reports · 156
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N638AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N638AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA20170125001Flashlight · inoperativeFWD CABIN FLASHLIGHT INOPERATIVE. REMOVED AND REPLACED FWD CABIN FLASHLIGHT IAW AMM 33-50-16-000-801-A AND 33-50-16-400-801-A OPS CHECKED GOOD.SDR SIMA20161222002Power Supply · inoperativeLT FWD OVERWING EMERGENCY EXIT LIGHT INOP. R&R NR 1 BATTERY POWER SUPPLY IAW AMM 33-50-04. EMERGENCY LIGHTS OPS CHECK GOODSDR SIMA20160904002Light · inoperativeDURING PS-1 CHECK FOUND FORWARD FLOOR PROXIMITY STRIP INOPERATIVE. EMERGENCY LIGHTING PROXIMITY STRIP. R & R FORWARD FLOOR PROXIMITY EMERGENCY LIGHTING STRIP IAW AMM 33-50-12. PERFORMED OPS CHECK OF EMERGENCY LIGHTING SYSTEM IAW AMM 33-50-00. OPS CHECK GOOSDR SIMA20160901006Light · inoperativeAFT CABIN CEILING EMERGENCY LIGHT INOPERATIVE. R & R AFT CABIN CEILING EMERGENCY LIGHT LAMP IAW AMM TASK 33-50-08-000-801-A AND TASK 33-50-08-400-801-A. OPS CHECK GOOD.SDR SIMA20160717001Bolt · shearedFA REPORTED MAIN CABIN DOOR HANDLE LAST 2 INCHES OF TRAVEL DIFFICULT AND DOOR SEAL SQUEALING IN FLIGHT. FOUND BOLT ON MAIN PAX DOOR HANDLE BOX ASSY SHEARED. INSTALLED NEW BOLT IAW AMM 20-10-01. ALSO LUBRICATED DOOR AND ALL MECHANISMS IAW AMM 52-18-00. OPS CHSDR SIMA20160715002Control Module · failedCREW REPORT ELECTRICAL BURNING ODOR NEXT TO PASSENGER DOOR. CABIN LIGHTS CONTROL MODULE FOUND BAD. REMOVED AND REPLACED IAW AMM 33-21-01 AND OPS CHECKED GOOD. NO OTHER ELECTRICAL BURNING ODORS NOTICED.SDR SIMA20160710003Control Module · failedARRIVAL, ACFT NO POWER SELECTED, BUT GPU AVAILABLE LIGHT, NOT SELECTED) FO TURNED BATTS ON MFD SHOWED GPU VOLTAGE AT 37.7 V INTERIOR SIDE WALL LIGHTS ON ALL LEFT HAND SIDE INOP AND SHE (FA) SMELLED A FAINT BURNING ODOR. REMOVED AND REPLACED CONTROL MODULE I.SDR SIMA20160519001Roller · lack of lubeFLIGHT ATTENDANT HAS DIFFICULT TIME CLOSING THE MAIN DOOR. THE TOP PART OF THE DOOR STAYS OPEN. LUBED AIRFRAME DOOR ROLLERS. PERFORMED OPERATIONS CHECK OF MAIN PAX DOOR IAW AMM 52-18-00. OPERATIONS CHECKED GOOD.SDR SIMA20160301005Skin · crackedFRAME 75, STRINGER 1R - 3R, UPPER AREA FASTENER HAS CRACKS. PERFORMED PERMANENT REPAIR IAW ERS-EM-53MR-1959.SDR SIMA20160301006Skin · crackedFRAME 75, STRINGER 1L - 3L, UPPER AREA SKIN HAS CRACKS. PERFORMED PERMANENT REPAIR OF UPPER SKIN AT FRAME 75, STRINGER 1L - 3L, IAW ERS-EM-53MR-195.SDR SIMA20160301001Reinforcement · crackedREINFORCEMENT FRAME ABOVE LT WINDSHIELD LATERAL POST CRACKED, PERMANENT REPAIR. R & R REINFORCEMENT ABOVE LATERAL POST IAW ERS-EM-53MR-203.SDR SIMA20160226005Skin · corrodedSKIN CORROSION FRAME 65 - 66, BETWEEN STRINGER 21L - 21R. ACCOMPLISHED PERMANENT REPAIR IAW ERS-EM-53MR-1944.SDR SIMA20160226006Wire · damagedLEFT NR 1 EMER LIGHT STRIP WIRES PULLED OFF. R & R LT NR 1 FLOOR EMER LIGHT STRIP IAW AMM 33-50-12.SDR SIMA20160226007Wire · brokenLEFT 66 FLOOR PROXIMITY LIGHT STRIP HAS BROKEN WIRE AT BASE OF LIGHT. R & R NR 6 PROXIMITY LIGHT STRIP IAW AMM 33-50-12.SDR SIMA20160226008Wire · brokenLEFT NR 5 FLOOR PROXIMITY LIGHT STRIP HAS BROKEN WIRE AT BASE OF LIGHT. R & R NR 5 PROXIMITY LIGHT STRIP IAW AMM 33-50-12.SDR SIMA20160226004Skin · corrodedCORROSION ON SKIN, FRAME 67, BETWEEN STRINGER 21L - 21R. ACCOMPLISHED PERMANENT REPAIR IAW ERS-EM-53MR-1945.SDR SIMA20160223002Skin · corrodedE492453 INTERNAL SKIN CORRODED, BETWEEN FRAME 13 - 14, STRINGER 21L - 20L. PERFORMED PERMANENT REPAIR OF INTERNAL SKIN CORROSION IAW ERS- EM-53MR-1933.SDR SIMA20160208009Inverter · inoperativeNUMBER 1 EMER FLOOR LIGHT STRIP INOPERATIVE. R & R NR 2 EMER LIGHT DC & AC INVERTER IAW AMM 33-50-11. COMPLIED WITH OPERATIONAL CHECK OF THE EMER LIGHTING SYS.SDR SIMA20160208007Inverter · inoperativeFORWARD GALLEY LOWER EXIT IDENTIFIER INOPERATIVE. R & R NR 2 EMER LIGHT DC & AC INVERTER IAW AMM 33-50-11. FWD GALLEY LWR EXIT IDENTIFIER LIGHT CHECKED GOOD. COMPLIED WITH OPERATIONAL CHECK OF THE EMER LIGHTING SYS.SDR SIMA20160208006Holder · crackedFOUR EACH PROXIMITY LIGHT HOLDERS, TWO EACH RT SIDEWALLS & ONE RAMP PANEL TRIM ARE CRACKED. R & R FOUR EACH PROXIMITY LIGHT HOLDERS, TWO EACH RT SIDEWALLS & ONE RAMP PANEL TRIM IAW AMM 33-50-12.SDR SIMA20160208008Battery · disconnectedCABIN AFT FLASHLIGHT INOPERATIVE. UPON FURTHER INVESTIGATION FOUND INTERNAL BATTERY DISCONNECTED. RE-CONNECTED BATTERY AS REQUIRED. OPERATIONAL CHECKED GOOD.SDR SIMA20160208005Wire · damagedEMERGENCY LIGHT STRIPS HAVE DAMAGED WIRE INSULATION AT FLOOR PANELS 241DF, 251DF & 251HF. REPAIRED EMER LIGHT STRIP WIRES, TWO EACH AT FLOOR PANELS 241DF, 251DF & 251HF IAW SWPM 20-21-00, FOR OPERATIONS CHECK SEE E495678.SDR SIMA20160105001Light · inoperativeRIGHT WING, EXT EMER LIGHT INOPERATIVE. R & R BULB RT WING LIGHT EMER IAW AMM 33-50-10. NO DEFECT NOTED.SDR SIMA20150621002Light · inoperativeLEFT SIDE CTR FAIRING EXTERNAL EMER LIGHT INOPERATIVE. R & R LT OVERWING EMER LIGHT LAMP IAW AMM 33-50-07. OPERATIONS CHECKED OK.SDR SIMA20150417002Sign · inoperativeCEILING EMER EXIT ILLUMINATED SIGN AT OVERWING EXITS IS INOPERATIVE ON FWD SIDE. R & R FWD CEILING EMER EXIT ILLUMINATED SIGN AT OVERWING EXITS IAW AMM 33-50-15. OPERATIONS CHECKED GOOD.SDR SIMA20150408006Power Supply · inoperativeAISLE EMER LIGHT AT ROW 3 INOPERATIVE. R & R AISLE EMER LIGHT LAMP AT ROW 3 IAW AMM 33-50-08-000-801-A & 33-50-08-400-801-A, NO FIX. R & R NR 1 EMER LIGHT BATTERY POWER SUPPLY IAW WC 33-700-19. OPERATIONS CHECKED GOOD. EMER LIGHT BATTERY PN 2013-1ASMI, SN SDR SIMA20150408007Light · inoperativeCOCKPIT EMER LIGHT INOPERATIVE. R & R COCKPIT EMER LIGHT LAMP IAW AMM 33-50-08-000-801-A & 33-50-08-400-801-A.. OPERATIONS CHECKED GOOD.SDR SIMA20150122002Light · inoperativeOVERWING EMER LIGHT OUT. R & R LIGHT BULB IAW AMM 33-50-07.SDR SIMA20141125004Pressure Switch · failedABORTED TAKEOFF DUE TO NR 2 PACK OCLD & NR 2 PACK OVERHEAT CAUTION MESSAGES. R & R OF HIGH STAGE PRESSURE SWITCH.SDR SIMA20141103001Flashlight · defectiveCAPTAIN`S FLASHLIGHT DIM. R & R CAPTAIN`S FLASHLIGHT IAW AMM 33-50-16. OPERATIONS CHECKED GOOD.SDR SIMA20141022002Coupling · damagedTRANSFERRED FROM LOG PAGE 3715116 ITEM 1 MEL 21-27. C PACK 1 OVLD PACK 1 OVLD EICAS MSG DURING TAKEOFF ROLL. TAKEOFF ABORTED LOW SPEED. INSPECTED & FOUND COUPLING 11 WITH LARGE HOLE BLOWN THROUGH IT. R & R COUPLING IAW AMM 21-51-03 & ETN-EM-21-056. OPERASDR SIMA20140914005Cowling · crackedWHILE ACCOMPLISHING PART C OF ERS-EM-54DF-164, HFEC INDICATED 2 1/2 INCH CRACK, 3/8 INCH FWD OF RIVET ROW, LT LOWER ENG COWL, IN LOWER FWD AREA, IN 6 INCH X 6INCH PRIMED AREA AFTER CONTOURED. R & R LOWER ENG COWLING IAW AMM 71-11-01.SDR SIMA20140908002Warning System · activatedHI SPEED ABORT 80 KNOTS GPWS INOPERATIVE. TERR INOP CAUTION. ITEM DEFERRED IAW MEL 34-10. PERFORMED HIGH ENERGY STOP INSPECTION IAW MM 5-20-16 NO DEFECTS NOTED AT THIS TIME.SDR SIMA20140730007Sign · inoperativeEMERGENCY EXIT SIGN ON FWD BULKHEAD IN FRONT OF 3B INOPERATIVE. INSPECTED CONNECTORS FOR NR 3 DC & AC INVERTER. RECONNECTED AS REQUIRED. OPERATIONS CHECKED EMER LIGHT IAW AMM 33-50-00. OPERATIONS CHECKED GOOD AT THIS TIME.SDR SIMA20140725001Warning System · false activationBLEED 2 LEAK INDICATION ON EICAS ONLY, APPLIED PROCEDURE & MSG REMAINED. WENT OUT AFTER APPROX 10 - 12 MINUTES. NO FURTHER INDICATION. PERFORMED LEAK TEST OF RT BLEED. OPERATIONS CHECK & LEAK CHECKED GOOD IAW AMM 36-00-00. NO FURTHER DEFECT NOTED.SDR SIMA20140429002Control Unit · failedON LANDING BRAKE DEGRADE MSG FLASHED ON EICAS BRAKES WORKED ABOUT 1/2 NORMAL. USED THRUST REVERSE TO STOP. BRAKE TEMP ON OTBD BRAKES HIGH TO MID AMBER RANGE. INBD BRAKE TEMP LOW TO MID GREEN RANGE. R & R BCU IAW AMM 32-41-02, OPERATIONS CHECKED GOOD.SDR SIMA20140317001Roller · dirtyPASSENGER DOOR DIFFICULT TO OPEN. CLEANED & LUBRICATED MAIN DOOR FRAME ROLLERS IAW EMB MM 53-21-02. OPERATIONS CHECK OF DOOR OK IAW MM 56-10-01.SDR SIMA20140228002Flashlight · defectiveFIRST OFFICER`S FLASHLIGHT CHARGING STATION NOT CHARGING. REPOSITIONED FIRST OFFICER`S FLASHLIGHT 33-5-16 AMM WORKING GOOD.SDR SIMA20140210003Spar · crackedRIGHT SPAR III CRACKED AT HARNESS CUTOUT. PERFORMED PERMANENT REPAIR ON RT SPAR III IAW ERS-EM-57MR-074.SDR SIMA20140209001Spar · crackedLEFT SPAR III CRACKED AT THE HARNESS CUTOUT. PERFORMED PERMANENT REPAIR ON LT SPAR III IAW ERS-EM-57MR-083.SDR SIMA20140203004Skin · crackedFOUND LT LATERAL WINDSHIELD POST SKIN CRACKED. CUT OUT DAMAGE, INSTALLED DOUBLER & SHIMS IAW ERS-EM-53MR-203.SDR SIMA20140116007Light · unknownLEFT NR 1 PROXIMITY LIGHT STRIP IS INCORRECT. R & R LT NR 1 PROXIMITY LIGHT STRIP IAW AMM 33-50-12.SDR SIMA20140116006Wire · brokenEMERGENCY FLOOR PROXIMITY LIGHT STRIPS NR 2, 5 & 6 HAVE BROKEN OR DAMAGED WIRES. R & R NR 2, 5 & 6 EMERGENCY PROXIMITY LIGHT STRIPS TO COVER PANEL AS REQUIRED.SDR SIMA20140116005Wire · brokenEMERGENCY LIGHT STRIP WIRE IS BROKEN BETWEEN FRAMES 43 & 44. INSTALLED SPLICES SP9115 & SP9116 TO EMERGENCY LIGHT STRIP WIRE BETWEEN FRAMES 43 & 44 IAW SWPM 20-21-00 STEP 5.SDR SIMA20131107001Roller · lack of lubeMAIN CABIN DOOR HARD TO OPEN, CLOSE AND LOCK. LUBRICATED MAIN CABIN DOOR FRAME ROLLERS IAW 52-11-00. CHECKED GOOD IAW AMM 52-10-01.SDR SIMA20131002001Flashlight · inoperativeF/A'S FLASHLIGHT INOPERATIVE. R & R FLASHLIGHT IAW CMM 25-60-02. OPS GOOD.SDR SIMA20130915002Lamp · inoperativeSERVICE DOOR OVERHEAD EMERGENCY LIGHT INOPERATIVE. R & R SERVICE FOOR OVERHEAD EMERGENCY LIGHT LAMP IAW AMM 33-50-09-000-801-A AND 33-50-09-400-801-A. OPS CHECKED GOOD.SDR SIMA20130727008Lamp · inoperativeLEFT OVERWING EMERGENCY LIGHT INOP. R & R LAMP IAW AMM TASKS 33-50-10-000-801-A/ 33-50-10-400-801-A. OPS CHECKED GOOD.SDR SIMA20130606001Holder · defectiveTHE CREW REPORTED THE F/A’S FLASHLIGHT WOULD NOT STAY SECURED IN ITS CHARGER. THE ACFT WAS REMOVED FROM SERVICE. R & R THE F/A’S FLASHLIGHT IAW AMM 33 51 01. THE OPS CHECK WAS GOOD. THE ACFT WAS RETURNED TO SERVICE.SDR SIMA20130502004Circuit Breaker · trippedON FLIGHT 3250 THE CREW REPORTED THAT ON TAXI-IN, INTPH 2 CB POPPED (33B). THE CREW NOTICED AN ELECTRICAL BURNING ODOR. THE AIRCRAFT WAS REMOVED FROM SERVICE. CHECKED WIRE HARNESS' BEHIND GLARESHIELD PTT SWITCH, F/O HEADSET JACK PANEL, #2 ACP. NO EVIDENCE