N655UA
Service difficulty reports · 383
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N655UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N655UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2013041202526Wire · damagedLEFT ENGINE FIRE LOOP 2 STATUS MESSAGE INTERMITTENTLY IN FLT. FOUND FIRE LOOP WIRES INSULATION AND BROKEN STRANDS DEFECTIVE. WIRE REPAIRED IAW MM 71-51-00. GROUND FUNCTIONAL TESTED GOOD.SDR UALA2013041202525Clamp · defectiveNR 1 ENGINE FEEDER CABLE CLAMP INSULATION BAD AT 10:00 POSITION. REPLACED DEFECTIVE CLAMP.SDR UALA2013040202126Fairing · out of toleranceREF CF0606 NEED TO REMOVE STRUT BIFURICATION PANEL AT THE 12 O'CLOCK POSITION ON THE NR 2 ENGINE. REPLACED OUTBOARD BIFURICATION FAIRING AT THE 12 O'CLOCK POSITION.SDR UALA2013040102108Precooler · crackedFOUND NR 2 ENGINE PRECOOLER HOUSING CRACKED AT LEFT SIDE FORWARD LOWER CORNER. REMOVED NR 2 PRECOOLER IAW MM. INSTALLED PRECOOLER IAW AMM.SDR UALA2013032802012Switch · faultyAPU FAULT NO START 2 ATTEMPTS. APU INOP. DF. REF MEL 49 11D. INF- :BIT APUC FAULTING THE FAN VALVE. INF- :IPC 49-51-00-00K PAGE 1 ITEM 100. (PCN 645-3645). RPL- :DISREGARDED NUISANCE OIL COOLER FAN AIR VALVE. VALVE HAS BEEN ELIMINATED REF POST SB 49-73-9SDR UALA2013032601900Lens · damagedEMERGENCY LIGHT LENS COVER AT SEAT 14AB IS DAMAGED. REPLACED LENS.SDR UALA2013032601899Power Supply · inoperativeEMERGENCY LIGHTS ARE INOPERATIVE ON LEFT SIDE FROM SEAT 24AB TO SEAT 33AB. REPLACED POWER SUPPLY AND BATTERY NEAR SEAT 29AB, OP CHECKED OKAY.SDR UALA2013032601898Connector · inoperativeEMERGENCY LIGHT IS INOPERATIVE ON RIGHT AFT CABIN NEAR R2 DOOR. SECURED LOOSE CONNECTOR, OPS NORMAL.SDR UALA2013032601897Line · damagedTWO .375 INCH DIAMETER STAINLESS STEEL TUBING DAMAGED FROM CHAFING; HAS FLAT SPOT APPROX .750 INCH LONG BY.125 IN WIDE LOCATED APPROXIMATELY 6 INCH FWD OF MAIN OIL FILTER ON NR 1 ENG. REMOVED LINES. REPLACED DAMAGED LINES.SDR UALA2013032601901Lens · missingEMERGENCY LIGHT LENS COVER IS MISSING AT SEAT 8AB. REPLACED LENS.SDR UALA2013031801625Blade · damagedNR 1 ENGINE BLADE NR 15 REQUIRES REWORK. ACCOMPLISHED BLEND IAW MM72-31-02-801 AND ACP HFEC INSPECTION PER NTM UAL PART6 72-31-401.SDR UALA2013030801391Bleed Valve · inoperativeAPU BLEED VALVE INOPERATIVE CLOSED. FLT CREW CONFIRMED VALVE CLOSED. REPLACED APU BLEED VALVE PER AMM, OPS CHECK GOOD WITH NO DEFECTS NOTED.SDR UALA2013030701358Faucet · leakingMID LAV LEAKING WATER ON FLOOR. MID LEFT LAV WATER SINK LEAKING SHUTOFF WATER OFF TO SINK NO OTHER LEAKS NOTED. FOUND WATER LEAKING FROM FAUCET. REPLACED FAUCET, OPS GOOD. NO FURTHER LEAKS NOTED. OK TO CONTINUE.SDR UALA2013030701359Tire · crackedRIGHT NOSE TIRE GROOVE CRACKING. REMOVED AND REPLACED RIGHT NOSE TIRE AND WHEEL ASSEMBLIES PER AMM.SDR UALA2013020800763Bleed Valve · failedNR 2 PRSOV FAILED HEALTH CHECK. SOLENOID FAILED TO ACTUATE WHEN ENERGIZED. REPLACED NR 2 ENGINE PRSOV IAW MM. NO LEAK PRESENT. SYSTEM OPERATED NORMAL PER MM.SDR UALA2013020400690Audio Panel · inoperativeCAPTAIN`S FLIGHT INTERPHONE IS NOT WORKING. ALL OTHER COMMS FUNCTION ON CAPTAIN`S PANEL, WORK NORMAL. REPLACED CAPTAINS AUDIO CONTROL PANEL,OPS CHECKED GOOD.SDR UALA2013020100589Windshield · faultyCAPTAINS WINDOW HEAT INOPERATIVE. REPLACED WINDOW PER AMM 5 6-11-01. COMPLETED UP TO ITEM 12 AND FIRST TORQUE.SDR UALA2013020100588Terminal Block · damagedTERMINAL BLOCK TB322 SENSOR 1 ON CONNECTOR IS SEPARATED FROM MOUNTING IN AVIONICS BAY. RESECURED TB322 BLOCK 6 AND PINNED TO NORMAL POSITION IAW WDM 30-41-11 PAGE 1. 1 SHEET 2.SDR UALA2012122107361Actuator · faultyDURING CLIMB, 7.5 UNITS OF LT TRIM NEEDED AND DURING CRUISE 4.5 UNITS LT TRIM NEEDED. FOUND NR 6 SPOILER DROPS AFTER HYDRAULIC. REMOVED DURING DROP TEST. REPLACED NR 6 SPOILER ACTUATOR PER MM 27-61-02 .SDR UALA2012121407238Light · inoperativeFLOOR EEL INOP: IN FRT OF RT MID LAV AND CLOSET. REPLACED EEL LIGHT STRIP ACCORDING TO AMM, OPS CHECK GOOD.SDR UALA2012101705918Wire · damagedACRID ODOR IN AFT GALLEY. DIMINISHED AFTER TURNING OFF CHILLERS AND LIGHTS IN GALLEY. FOUND A BURNED SPEAKER WIRE. FOUND 3 GALLEY CART PIGTAILS DAMAGED. REPLACING SPEAKER & WIRE AND REPAIRED AND REPLACED GALLEY CART PIGTAILS.SDR UALA2012100205573Starter · faultyAPU WILL NOT START EGT 715 & RPM 25 THEN SHUT DOWN PERFORMED BITE CHECK AND SHOWS NO ACCELL LAST 2 START ATTEMPTS WITH PT SENSOR. SEE 49-11-00 FOR T/S INFO. TESTED HYD GEN PER MM. REPLACED STARTER AND APU STARTED NORMAL.SDR UALA2012081404495Controller · failedRIGHT ENGINE PRC FAILED PNEUMATIC HEALTH AND PRV SHAFT HAS EXCESS PLAY. REPLACED PRC PER AMM AND PRV PER AMM. ACP'D BLEED SHIFT, ALL PRESSURES AND INDICATIONS NORMAL.SDR UALA2012080804302Controller · malfunctionedBLEED LT RT SIDE AND RT ENG HPSOV EICAS AND STATUS MESSAGE. REPLACED HPC PER AMM. ALL PRESSURES & INDICATIONS NORMAL HIGH POWER RUN.SDR UALA2012080704248Warning Light · false activationRT ENG BLEED LGT AND R ENG HPSOV EICAS MSG DURING DESCENT WITH ENG BLEED SW ON, AND ENG RUNNING. DUCT PRESSURE IS 15PSI. ACCOMPLISHED AIR SUPPLY CONTROL SYSTEM TEST PER AMM TASK 36-23-00-715-001. NO FAULTS NOTED ON AIR SUPPLY BITE MODULE.SDR UALA2012071103744Panel · damagedFWD PIT SIDE WALL PANEL DAMAGED BEYOND REPAIR REF FCD2553-01115. REPLACED PANEL.SDR UALA2012070503602Light · inoperativeNUMBER 2 FIRE BOTTLE DISCHARGE LIGHT INOPERATIVE.SDR UALA2012070103499Controller · faultyRIGHT ENG HPSOV EICAS ILLUMINATED. OCCURED WHEN POWER STABILIZED AT LEVEL OFF. TROUBLESHOT HPSOV-HPC SYSTEM. REPLACED HPC FOR FAILURE. PERFORMED AIR SUPPLY BITE SYSTEM TEST, OPS CHECK GOOD.SDR UALA2012062903468Failsafe · corrodedAFT CARGO BAY BS 1562 FAILSAFE CORRODED BETWEEN STR 39L -39R AT FUSELAGE DRAIN HOLE. REMOVED CORROSION FROM FAILSAFE & FOUND MATL LOSS WITHIN LIMITS OF SRM 51-10-02.SDR UALA2012062203391Wire · openWHEN MOVING SWITCH FOR EMERGENCY LIGHTS CONTROL TO OFF POSITION ON THE P5 PANEL LIGHTS ARE ILLUMINATED. FOUND OPEN WIRE W1240-005 3-20 IN ROW 31 CEILING OVERHEAD AREA. REPAIRED AND INSTALLED SPLICE IAW B767-300 SWPM 20-30-12. OPS CHECK GOOD IAW 767 AMM 31-5SDR UALA2012062203373Oxygen Mask · misinstalledLEFT CABIN O2 MASKS PACKED INCORRECTLY. REPACKED LEFT CABIN O2 MASKS AND CLOSED PSU'S REF B767-300 AMM 35-21-14.SDR UALA2012061503277Oxygen Mask · misinstalledRIGHT PSU O2 MASK INCORRECTLY PACKED. REPACKED RT O2 MASK PER AMM.SDR UALA2012060303066Fastener · burnedFOUND 26 BURNED FASTENERS ON RIGHT FORWARD FUSELAGE BETWEEN STA 246 AND 434, STRINGERS 24 TO 28. REMOVED AND REPLACED 26 BLIND FASTENERS ON NR 4999N00397 IAW B767-300 SRM 53-00-01 REPAIR 8.SDR UALA2012032601926Wire Harness · brokenFOUND EGT HARNESS AT PROBE NR 2 BROKEN. HARNESS IN NR 1 ENG REPLACED PER MM.SDR UALA2012030201313O-Ring · leakingAFTER 5 MIN IDLE FOUND LEAKAGE AROUND THE OIL TANK CAP AREA. REPLACED OIL TANK CAP O-RING PER A-CK J-C.SDR UALA2012030201307Fireseal · missingPANEL 437AR AFT FIRE SEAL MISSING. REPAIRED FIRE SEAL SECTION.SDR UALA2012021500932Fmu · faultyRT ENG FUEL FILTER IND, RTFL. PUMP METERING VALVE READY TO BE RMV'D. NR 2 ENG FUEL PUMP & FUEL METERING UNIT RMV'D FOR LOG2. ACCMP'D REMOVAL REF MM 73-11-01 PAGE 412 PARAGRAPH 3A AND MM 73-21-03 PARAGRAPH 3 E 2. INSTALLED NEW FUEL PUMP AND FUEL METERING USDR UALA2012020600718Regulator · leakingPRIOR TO COA 615671 FOUND O2 SYSTEM LEAKING WHEN SUPPLY WAS SHUTOFF. OXYGEN LEAK EXCEEDS LIMITS. OXY PRESS REG RPLC'D, OPS CK LEAK CKD SYS GOOD.SDR UALA2012013000599Blade · nickedUNFILED NICK ON OUTER BLADE (7 O'CLOCK) POSITION ENG NR 1. FOUND NR 4 FAN BLADE WITH NICK AT LEADING EDGE 0185 INCH DEEP ABOUT FIVE EIGHT INCH FROM EDGE AND ONE TREE QUARTER OF INCH AT END. ACCOMPLISHED BLADE BLEND PER AMM. BLADE WILL REQUIRE EDDY CURRENT ISDR UALA2012012300482Brake · damagedNR 1R BRAKE LEAKING AND PUCKS DAMAGED ON ARRIVAL. REPLACED BRAKE PER MM.SDR UALA2012012300477Computer · inoperativeTMC INOPERATIVE. REPLACED TMC PER MM. OPERATED NORMAL, AIRCRAFT REMOVED FROM CATIII, ACCOUNT OF TMC CHANGE SEE DEFERRED ITEM FOR CATIII CHECK.SDR UALA2012010600149Gcu · faultedLT GENERATOR FAULT, FLIGHT DIVERTED. CARRIED OUT BPCU BITE CHECK. FOUND LEFT GENERATION SYSTEM FAULTS. REPLACED LT GCU AND IDG REF MM. FURTHER T- S REQUIRED DUE FAULTS STILL EXISTING. ITEM TRANSFERRED TO SMC6 AS FAULT NOW WITH DAMAGED C901 CONTACTOR IN P3SDR UALA2012010300056Display · failedACARS CDU BLANKING. REPLACED ACARS CDU.SDR UALA2011121406869Controller · failedRT ENG BLEED OFF AND NO AIR AVAILABLE FOR RT ENGINE ANTI ICE, ACCOMPLISHED PNEUMATIC HEALTH CHECK ON RT ENG PRIORITY VALVE PER MM. FOUND WIRE W3508-009-18 CHAFED TO GROUND APPROX 14" AWAY FROM D11116P. REPAIRED INSULATION PER SWPM. ALSO PRC FAILED HEALTH CHECSDR UALA2011121406868Control Valve · malfunctionedRIGHT PACK OFF-RIGHT BLEED OFF PROBLEMS. ACCOMPLISH RIGHT PACK LOW LIMIT VALVE TEST PER MM. ACCOMPLISH PACK TEMP CONTROLLER BITE PROCEDURE PER MM. IF NO FAULTS FOUND WITH THE LOW LIMIT VLV OR PACK TEMP CONT BITE, REPLACE THE RIGHT PACK FLOW CONTROL VLV PCSDR UALA2011121406843Linkage · unsecureON WALKAROUND FOUND STEERING LINK AT NLG WITH ONE BOLT LOOSE AND THE OTHER ONE NOT INSTALLED. REPLACED MISSING BOLT AND CHKD IAW MM, CKD OKAY. BOLT REPLACED IS IAW ECRA3251-01031 INSTALLED SUBSTITUTE BOLT NAS67004U15 AND TWO EXTRA WASHERS CKD OK AS PERMANENTSDR UALA2011121206782Shutoff Valve · leakingRIGHT BLEED ISSUE, RTFL. PRSOV LEAKING. REPLACED PRSOV. LEAK CHECKED LINE TO PRSOV, OK. COMPLETED RUN UP BLEED SHIFT, OK. ALL PRESSURES NORMAL.SDR UALA2011112906554Circuit Card · inoperativeFWD CARGO ARM LIGHT INOPERATIVE. REPLACED CIRCUIT CARD PER MM, ALL TESTS PASSED.SDR UALA2011112106405Pressure Switch · faultyLOW PRESS LT ON RT FWD FUEL PUMP NOT ON WITH SWITCH IN OFF POSITION. LT TESTS GOOD ON IND LT. REPLACED AFT RT FUEL PRESSURE SWITCH PER MM.SDR UALA2011101905670Computer · inoperativeTMC CONTROL PANEL INOPERATIVE. REPLACED TMC, OP CHECKED NORMAL.