What was found
APU WILL NOT START EGT 715 & RPM 25 THEN SHUT DOWN PERFORMED BITE CHECK AND SHOWS NO ACCELL LAST 2 START ATTEMPTS WITH PT SENSOR. SEE 49-11-00 FOR T/S INFO. TESTED HYD GEN PER MM. REPLACED STARTER AND APU STARTED NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
APU WILL NOT START EGT 715 & RPM 25 THEN SHUT DOWN PERFORMED BITE CHECK AND SHOWS NO ACCELL LAST 2 START ATTEMPTS WITH PT SENSOR. SEE 49-11-00 FOR T/S INFO. TESTED HYD GEN PER MM. REPLACED STARTER AND APU STARTED NORMAL.