N656AE
Service difficulty reports · 202
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N656AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N656AE' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR HNAA2026101901011Firewall · crackedAPU FIREWALL WAS CRACKED ABOVE UPPER LEFT APU MOUNT ATTACH BRACKET. PERFORMED DOUBLER AND FILLER REPAIR ON APU FIREWALL IAW ETD2026-145-017372, REV A AND EO1-53-26-0511.SDR HNAA2026101901020Gusset · corrodedL/H FLOOR OMEGA BEAM GUSSET #2 HAS CORROSION IN MULTIPLE AREAS. RAR L/H FLOOR OMEGA BEAM GUSSET #2 IAW EMB 145 SRM 51-40-02 AND SRM 51-40-09.SDR HNAA2026101901019Seat Track · corrodedR/H LOWER SEAT TRACK #2 HAS CORROSION IN MULTIPLE AREAS. REMOVED AND REPLACED R/H LOWER SEAT TRACK #2 IAW EMB 145 AMM 53-01-06.SDR HNAA202610191018Seat Track · corrodedLEFT LOWER SEAT TRACK NR 2 WAS CORRODED IN MULTIPLE AREAS. R & R THE SEAT TRACK NR 2 IAW AMM 53-01-06.SDR HNAA202610191017Seat Track · corrodedRIGHT UPPER SEAT TRACK NR 1 WAS CORRODED IN MULTIPLE AREAS. REMOVED AND REPLACED THE SEAT TRACK NR 1 IAW AMM 53-01-06.SDR HNAA202610191016Gusset · corrodedCENTER FLOOR OMEGA BEAM GUSSET BETWEEN FR-44/45 HAS CORROSION. R & R CENTER FLOOR OMEGA BEAM GUSSET BETWEEN FR-44/45 IAW SRM 51-40-02 AND SRM 51-40-06SDR HNAA202610191015Floor Support · corrodedRT FLOOR SUPPORT NR 5 HAS CORROSION IN MULTIPLE AREAS. REMOVED AND REPLACED THE RT FLOOR SUPPORT IAW SRM 51-40-02.SDR HNAA2026101901014Seat Track · corrodedRIGHT LOWER SEAT TRACK NR 3 HAD CORROSION IN MULTIPLE AREAS. REMOVED AND REPLACED THE RT LOWER SEAT TRACK IAW AMM 53-01-06.SDR HNAA2026101901013Seat Track · corrodedLEFT LOWER SEAT TRACK NR 5 HAD CORROSION IN MULTIPLE AREAS. R & R LT LOWER SEAT TRACK IAW AMM 53-01-06.SDR HNAA2026101901012Seat Track · corrodedLEFT UPPER SEAT TRACK NR 4 WAS CORRODED IN MULTIPLE AREAS. REMOVED AND REPLACED THE SEAT TRACK NR 4 IAW AMM 53-01-06.SDR HNAA2026101901010Floor Support · corrodedRIGHT FLOOR SUPPORT CORRODED BETWEEN FRAMES 18 & 19. PERFORMED DOUBLER REPAIR ON RT FLOOR SUPPORT IAW ETD2026-145-016742 AND EO1-53-26-0491.SDR HNAA2026101901009Shear Tie · crackedSHEAR TIE ON FR 73 BTWN STRINGERS 8R AND 9R HAD A POSSIBLE CRACK. R & R SHEAR TIE IAW SRM 51-40-02.SDR HNAA2026101901008Attach Bracket · crackedPASSENGER DOOR INTERNAL HANDLE ATTACH BRACKET WAS CRACKED. REMOVED AND REPLACED THE HANDLE ATTACH BRACKET IAW SRM 51-40-02.SDR HNAA2026101901007Hinge Fitting · excess playRUDDER LOWER HINGE FITTING HAD PLAY. R & R RUDDER HINGE FITTING IAW SRM 51-40-02, & SRM 51-20-01.SDR HNAA2026081400719Panel · faultedON CLIMB OUT BLEED 2 LEAK EICAS MSG. REMOVED RT PACK PANEL AND RT PACK VALVE PANEL FOR VISUAL INSPECTION OF BLEED LINES. NO DEFECTS NOTED DURING INITIAL INSPECTION. REINSTALLED PANELS WITH RETAINED HARDWARE.SDR HNAA2026061900550Regulator Valve · abnormalBLD VLV FAIL MSG DISPLAYED ON T/O ROLL. NO RELEVANT CMC MESSAGES ARE PRESENT. VERIFIED E2 WAS AT FAULT C/W MX PROCEDURE. FACT 18JUN26 03:29 PHL R+R BLEED VLV #2 IAW AMM 36-11-05 REQUIRES OPS+LEAK CHECK-SS 37112 18JUN26- INSTALLED BLEED VLV 2 IRW AMM 3SDR HNAA2026012300075Inverter · abnormal1ST ROW EMERGENCY LIGHT STRIP AND SERVICE DOOR EXIT SIGN INOP FACT 22JAN26 07:25 ROA R&R #200 INVERTER PER AMM 33-50-11 PN ON 7824-1 PN OFF 7824-1SDR HNAA2025123100869Light · inoperativeFWD EMERGENCY LIGHT STRIP INOP. RAR STRIP IAW AMM 33-50-12. OPS CHECK GOOD.SDR HNAA2025103100731Lamp · inoperativeEMERGENCY LIGHT 261BF INOPERATIVE. R & R EMERGENCY LIGHT 261BF IAW AMM 33-50-08. ACFT OK FOR SERVICE.SDR HNAA2025091400636Warning Message · illuminatedBAGGAGE DOOR OPEN MESSAGE DURING FLIGHT. BAGGAGE DOOR WARNING / POSITION WARNINGSDR HNAA2025081800575Light · inoperativeROWS 8/9 AND 10/11 EMERGENCY LIGHT FLOOR PROXIMITY STRIPS INOPERATIVE. R&R #400 FLOOR PROXIMITY LIGHT IRT AMM 33-50-12 R&R#5 EMERGENCY LIGHT AC/DC INVERTER IRT AMM 33-50-11 PN ON 1013194 FLOOR PROX LIGHT PN OFF 6636-7 FLOOR PROX LIGHT PN ON 1330312 AC/DC INVSDR HNAA2025070700465Strut · dischargedLDG AIR GRND FAIL WITH E1-E2 REV DISAGREE MESSAGE IN FLIGHT MESSAGE DISAPEARED WHEN GEAR DOWN AND LOCKED. SERVICED NLG SHOCK STRUT IAW AMM 32-20-01. PERFORMED AIR/GROUND SYSTEM SIMULATION ADJUSTMENT TEST IAW 32-63-00 & SWUNG GEARS MULTIPLE TIMES. NO DEFECTS NSDR HNAA2025033100192Ballast · failedFUMES NOTICED BY MAIN CABIN DOOR. FACT 29MAR25 00:41 CLT INSPECTED AND FOUND SIDEWALL LIGHT BALLAST AT 1A TO HAVE A BURNT ODOR. R+R BALLAST IAW AMM 33-21-03. OPS CHECK GOOD. NO MORE BURNING ODOR SMELTSDR HNAA2024091900832Unknown · fumesSLIGHT SMELL OF FUMES IN FLT DECK AND CABIN AROUND 26000FT. SMELL OCCURRED WHEN F/A WAS USING TEMP CONTROL. FACT 19SEP24 07:24 CLT PERFORED FIM TASK# 21-20-00-810-801-A. BLOCKS 1-11. NO DEFECTS NOTED. PACKS 1-2 RAN FOR EXTENDED TIME WITH NO FUMES DETECTED. SDR HNAA2024071800545Floor Support · corroded00179 UPON REMOVAL OF FLOOR BEAM CAP @ FRM 59 - 61 FOUND FLOOR BEAM TO HAVE EXCESSIVE CORROSION @ FRM 60 + 10" Y= + 479.0 AND REQUIRES REPAIR. COMPLETED ALL STEPS OF EMB ETD2024-145-017954 REV: / DATED 07/01/2024. REPAIR MATERIAL: 2024-T3 .08SDR HNAA2024071800544Shear Tie · not reported00166 SHEAR CLIP ON FRAME 65 BETWEEN STR15L-17L REQ REPLACED/REPAIR.SDR HNAA2024071800543Floor Support · corroded00135 CORROSION FOUND ON +479.0 FLOOR BEAM CAP BETWEEN FRM 59-61. REMOVED AND INSTALLED NEW SERVICEABLE FLOOR BEAM GUSSET PN: 145-26437-001 IAW EMB-145 SRM 51-20-03-PR AND 51-40-02-PRSDR HNAA2024071800542Floorbeam · corroded00133 FLOOR BEAM CAP AT FR22 AND Y +479 IS CORRODED. : REMOVED AND REPLACED DAMAGED FLOOR BEAM CAP (DOUBLER P/N 145-22461-011) IAW EMB-145LR SRM 51-40-02-PR.SDR HNAA2024071800541Floorbeam · corroded00131 RH FLOOR BEAM CAP AT Y +479 AT FR20 IS CORRODED. REMOVED AND INSTALLED NEW SERVICEABLE FLOOR BEAM CAP P/N 145-22461-011 IAW EMB-145LR SRM 51-40-02-PRSDR HNAA2024071800540Beam · corroded00073 MULTIPLE SPOTS OF CORROSION FOUND ON BOTTOM AREA OF BAGGAGE DOOR SURROUND STRUCTURE. REMOVED AND INSTALLED BEAM ASSY PN# 145-25480-603 (CARGO DOOR SILL) @ AFT CARGO DOOR LOWER SILL IAW EMB145-LR SRM 51-40-02-PRSDR HNAA2024052100428Pitot System · faultedPITOT 2 INOP CAUTION MESSAGE DISPLAYED. FACT 20MAY24 14:22 CLT R+R # 2 PITOT SENSOR IAW AMM 34-13-01. PERFORMED PITOT/STATIC SYS 2 LEAKAGE TEST IAW AMM 34-13-00-790-803A/500 PERFORMED OPS CK IAW AMM 30-31-00-700-803A/500SDR HNAA2024012600036Insulation · unsecureIN CRUISE STRONG ELECTRICAL BURNING SMELL IN FLIGHT DECK. FACT 26JAN24 01:13 TRI RAN PACK SYSTEMS 1 AND 2 USING APU AND ENGINE BLDS, INSPECTED AND OPERATED FLIGHT DECK EQUIPMENT WITH NO SMELLS NOTED. INSPECTED PACKS 1 AND 2 AND UNDERFLOOR DUCTS FOR OBVIOUSDR HNAA2023112000420Unknown · unknownDURING TAKE OFF WENT OFF. REVERSIONARY SWITCHED. EICAS SCREEN SHOWED PFD AND WOULD NOT RETURN. AFTER TOUCHDOWN EICAS SCREEN BLANKED OUT. R&R EICAS IAW AMM 34-22-01 AND R&R EICAS BEZEL IAW MM 31-41-02. PERFOREMD OPS CHECK IAW AMM 34-22-00. OPS CHECK GOOD. A/CSDR HNAA2023111600381Unknown · unknownEXCESSIVE NOSE WHEEL SHIMMY AFTER WHICH EICAS SCREEN WENT BLANK UNTIL SPEED WAS REDUCED. R+R'D NOSE WHEEL ASSYS IAW AMM 32-49-05. GREASED TORQUE LINGS AND TAXIED A/C 20 KNOTS, NO EXCESSIVE SHIMMY NOTED. A/C OKAY FOR SERVICE.SDR HNAA2023092600348Unknown · unknown3FLOOR STRIP EMERGENCY LIGHTS FROM LAV DOOR TO SEAT #12 ARE INOP. R & R INVERTER # 6 IAW AMM 33-50-11 OP TEST GOODSDR HNAA2022090700257Fadec · faultedHUNG START OF #2 ENG FOLLOWED BY EXHAUST FUMES. OIL NOTED DRIPPING FROM #2 LOWER COWLING. RAN E2 OFF FADEC A WITH NO DEFECTS NOTED. RAN E2 OFF FADEC B WITH HUNG START MULTIPLE TIMES. R/R FADEC 2B IAW AMM 73-22-01NO FIX. NO SIGN OF OIL LEAK DURING E2 ENGINE RSDR HNAA2022090700256Engine · hung startENGINE 2 HUNG START, AFTER START WAS ABORTED FUMES WERE NOTED IN CABIN AND FLIGHT DECK. INSPECTED #2 ENGINE FOR POSSIBLE FUEL LEAK. NONE FOUND. PERFORMED #2 ENGINE START FROM APU BLEEDS, PACKS OFF, AND #1 ENGINE BLEEDS, WITH PACKS OFF. BOTH TIMES ENGINE STARTSDR HNAA2022021000075Not Reported · not reportedPDIS 656 27-62 2706562 09FEB22 CLT CLOSE
IN FLT SPEED BRAKE HANDLE TO CLOSE, SPOILER FAIL MSG, A/C ROLLED RT AND AUTO PILOT FAILED. RAN QRH WITH SPOILERS REMAINING CLOSED REST OF THE FLIGHT DURING DECENT ABOUT 13K FT
FACT 09FEB22 16:08 CLSDR HNAA2022021000072Not Reported · not reportedE894481 - THE PASSENGER DOOR FORWARD FRAME EDGE HAS CHAFE SPOTS FROM CONTACT WITH THE LINER .... REMOVED AND REPLACED PASSENGER DOOR FORWARD FRAME IAW EMB145 SRM 51-40-02.SDR HNAA2022020700065Not Reported · not reportedE894714 - RH WING RIB 21 UPPER FLANGE CRACKED .... PERFORMED REPAIR TO RH WING RIB 21 IAW EO1-57-22-0005.SDR HNAA2022020700064Not Reported · not reportedE894713 - LH WING RIB 21 UPPER FLANGE CRACKED .... PERFORMED REPAIR TO LH WING RIB 21 IAW EO1-57-21-0376SDR HNAA2022020700059Not Reported · not reportedE893957 - REAR ELECTRONICS DOOR HAS DENT APPROXIMATELY 3" BELOW HANDLE .... ACCOMPLISHED REPAIR OF REAR ELECTRONIC COMPARTMENT DOOR SKIN APPROX. 3 INCHES BELOW HANDLE IAW EO1-52-21-0373.SDR HNAA2022021000074Not Reported · not reportedE896607 - R/H ENGINE CONTAINMENT RING GOUGED AT LOWER SURFACE .... BLENDED OUT GOUGE ON RH ENGINE CONTAINMENT
RING LOWER SURFACE IAW EMB 145 SRM 51-- 10-03. NO DAMAGE LIMITS FOR THIS AREA. MAPPED DAMAGE AND SENT OUT FOR FURTHER EVALUATION IAW PIEDMONT MPPM 13SDR HNAA2022021000073Not Reported · not reportedE894799 - LH INBD FLAP SHROUD HINGE HAS 2 FASTENERS THAT ARE PULLING THRU AT INBD END .... REMOVED LH INBOARD FLAP SHROUD HINGE
SECTION WITH 2 FASTENERS PULLING THROUGH AT INBOARD END, PREPPED AND INSTALLED SERVICEABLE HINGE SECTION IAW EMB 145 SRM 51-20-03, SDR HNAA2022020700063Not Reported · not reportedE894680 - STR 2L CHAFED BTW FR 20-21 .... REPAIRED STR 2L CHAFE BETWEEN FRAMES 20 - 21 IAW PIEDMONT EO1-53-22-0001.SDR HNAA2022020700061Not Reported · not reportedE894625 - THE RH WALL #1 FLOOR SUPPORT HAS CORROSION NEAR FRAME 24 AND FRAME 28 .... PERFORMED BLEND OUT OF DAMAGE ON RH WALL #1 FLOOR SUPPORT NEAR FRAME 24 AND FRAME 28 IAW EMB 145 SRM 51-10-03. REMAINING THICKNESS AT BLENDED AREAS ON THE RH WALL #1 FLOOR SUPSDR HNAA2022020700060Not Reported · not reportedE894621 - THE LH CENTER SEAT TRACK #3 HAS EVIDENCE OF CORROSION ON SEVERAL SPOTS ALONG ITS ENTIRE LENGTH .... REMOVED AND REPLACED THE LH CENTER SEAT TRACK #3 IAW EMB 145 AMM 53-01-06.SDR HNAA2022020700066Not Reported · not reportedPAX DOOR ENTRANCE FWD AND AFT FLOOR BOARD SUPPORT BRACKETS ARE CORRODED. RAR PAX DOOR ENTRANCE FWD AND AFT FLOOR SUPPORT BRACKETS IAW EMB-145 SRM 51-40--02.SDR HNAA2022020700067Not Reported · not reportedE895312 - FRAMED CRACKED ON UNDERSIDE AT FR 72 AT STR 16L .... REMOVED AND REPLACED FRAME 72 (LH SIDE FRAME SECTION) IAW EMB145 SRM 51-40-02SDR HNAA2022020700062Not Reported · not reportedE894627 - THE RH WALL #2 FLOOR SUPPORT HAS CORROSION BETWEEN FRAMES 33 AND 35 .... REMOVED AND REPLACED SERVICEABLE RH WALL #2 FLOOR SUPPORT IAW EMB 145 SRM 51-40-02.