N659UA

Service difficulty reports · 330

Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE n_number = 'N659UA' AND registry_match = 'registration'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR 2008UALA05615Structure · corrodedAFT PIT, UPPER CHORD FOR WEB AT STR 33L CORRODED ON THE LOWER SURFACE. *S/D* MAJOR REPAIR ACCOMPLISHED. INSTALLED NEW ANGLE.Sep 6, 2008 · N659UA · Boeing 767322 · Fuselage Main, StructureSDR 2008UALA05614Frame · damagedAFT PIT STA 1197+66 FRAME CAP HAS FLAKED PAINT AND LIGHT SURFACE CORROSION FROM LBL 48 - RBL 10. MAJOR REPAIR ACCOMPLISHED. INSTALLED NEW FRAME CAP.Sep 6, 2008 · N659UA · Boeing 767322 · Fuselage Main, FrameSDR 2008UALA05613Shear Tie · corrodedAFT PIT AT STA 1219, LBL 4 - RBL 4, CORROSION ON ANGLE AT FRAME ATTACH TO SKIN. *S/D* MAJOR REPAIR ACCOMPLISHED. FABRICATED & INSTALLED NEW SHEAR TIE.Sep 6, 2008 · N659UA · Boeing 767322 · Fuselage Internal Mounting StructureSDR 2008UALA05570Web · crackedNR 1 PYLON STA 156 WEB AT OUTBOARD DRAIN HOLE IS CRACKED, MIGRATED BEYOND EXISTING STOP DRILL. MAJOR REPAIR ACCOMPLISHED. FOUND 2 CRACKS AT INBOARD DRAIN HOLE. STOP DRILLED CRACKS. FABRICATED & INSTALLED A DOUBLER REPAIR.Sep 2, 2008 · N659UA · Boeing 767322 · Nacelle/Pylon Miscellaneous StructureSDR UALA2008111305605Connector · damagedFWD CARGO COMP BELOW FLOOR-EQUIP COOLING SUPPLY AIR OVERHEAT SWITCH CONNECTOR WIRE HAS INSULATOR DAMAGE AND BARE CONDUCTOR EXPOSED 19 INCHES UPSTREAM OF CONNECTOR D00644. REPAIRED WIRE IAW BSWPM 20 -30-12 AND OPS CHECKED GOOD.Aug 31, 2008 · N659UA · Boeing 767322 · Air Conditioning System WiringSDR 2008UALA05605Wire · damagedFWD CARGO COMP BELOW FLOOR-EQUIP COOLING SUPPLY AIR OVERHEAT SWITCH CONNECTOR WIRE HAS INSULATOR DAMAGE AND BARE CONDUCTOR EXPOSED 19 INCHES UPSTREAM OF CONNECTOR D00644.Aug 31, 2008 · N659UA · Boeing 767322 · Air Conditioning System WiringSDR 2008UALA05559Floorbeam · corrodedCABIN FLOORBEAM FRAME CORRODED STA 284 RBL 17. *S/D* MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGED SECTION OF FLOORBEAM TEE AND FABRICATED A NEW TEE REPAIR ANGLE. DAMAGED T-CAP REMOVED BETWEEN RBL 17 - RBL 22 AND WL 208. Aug 31, 2008 · N659UA · Boeing 767322 · Fuselage Main, Floor BeamSDR 2008UALA05558Floorbeam · corrodedMAIN CABIN FLOORBEAM T-CAP CORRODED AT BS 1502 AND LBL 28. *S/D* MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGED SECTION OF T-CAP. FABRICATED A-1 AND -2 REPAIR ANGLES, -3 STRAP AND 4 EACH SHIM AND INSTALLED. Aug 31, 2008 · N659UA · Boeing 767322 · Fuselage Main, Floor BeamSDR 2008UALA05557Floorbeam · corrodedMAIN CABIN FLOORBEAM T-CAP CORRODED UNDER STEEL SUBFLOOR AT BS 1518 AT BL 0. MAJOR REPAIR ACCOMPLISHED. REMOVED DAMAGED T-CAP SECTION. FABRICATED AND INSTALLED A NEW T-CHORD, SPLICE ANGLES & SPLICE STRAPS.Aug 31, 2008 · N659UA · Boeing 767322 · Fuselage Main, Floor BeamSDR 2008UALA05556Stiffener · crackedSTA 246 FLOORBEAM FWD SIDE VERT STIFFENER CRACKED AT LBL 26. MAJOR REPAIR ACCOMPLISHED. REMOVED AND INSTALLED NEW STIFFENER.Aug 31, 2008 · N659UA · Boeing 767322 · Fuselage Miscellaneous StructureSDR 2008UALA05523Ground Wire · damagedBARE WIRE EXPOSED AT TOP LEFT BURNDY BLOCK CONNECTION, HEATER TAPE GROUND, APPROX LOCATION AFT SIDE OF FLOORBEAM STA 266.5, LBL 68. REPLACED B97 HEATER TAPE GROUND WIRE.Aug 28, 2008 · N659UA · Boeing 767322 · Electrical Power System WiringSDR UALA2008111305420Spring · faultyL-2 DOOR MANUAL DEPLOY GAS CYLINDER INOP. REPLACED GAS SPRING.Aug 22, 2008 · N659UA · Boeing 767322 · Passenger/Crew DoorsSDR 2008UALA05418Latch · gougedRIGHT OVERWING SLIDE COMPARTMENT DOOR LATCH NR 3 SLIDER GOUGED. FOUND NR 3 LATCH GOUGED. REPLACED LATCH. OPS CHECKS GOOD.Aug 22, 2008 · N659UA · Boeing 767322 · Escape SlideSDR 2008UALA05417Latch · gougedRIGHT OVERWING SLIDE COMPT DOOR LATCH NR 1 SLIDER GOUGED. FOUND NR 1 LATCH GOUGED. REPLACED LATCH. OPS CHECKS GOOD.Aug 22, 2008 · N659UA · Boeing 767322 · Escape SlideSDR 2008UALA05420Cylinder · inoperativeL-2 DOOR MANUAL DEPLOY GAS CYLINDER INOP.Aug 22, 2008 · N659UA · Boeing 767322 · Passenger/Crew DoorsSDR 2008UALA05419Spring · weakR-1 DOOR DEPLOYMENT BAR GAS SPRING WEAK. REPLACED SPRING. OPS OKAY FOR SERVICE.Aug 22, 2008 · N659UA · Boeing 767322 · Service DoorsSDR 2008UALA04369Housing · crackedLT OVERWING DISCONNECT HOUSING CRACKED. REMOVED & REPLACED DISCONNECT HOUSING.Aug 20, 2008 · N659UA · Boeing 767322 · Escape SlideSDR 2008UALA03622Transmitter · malfunctionedFLIGHT CREW REPORT SLIGHT SPLIT BETWEEN LEFT AND RIGHT T/E FLAP INDICATOR NEEDLES NORMAL AT 1 AND 25 BUT SLIGHT SPLIT AT UNITS 5, 10 & 15. REPLACED LEFT FLAP POSITION TRANSMITTER NR 1 PER AMM CH 27-51-45 OP CHECK NORMAL. AC OK FOR SERVICE.Jun 27, 2008 · N659UA · Boeing 767322 · Trailing Flap Position Indicating SystemSDR 2008UALA00676Connector · damagedEMERGENCY EEL LIGHT INOPERATIVE AT SEAT 5AB. SECURED CONNECTOR.Feb 5, 2008 · N659UA · Boeing 767322 · Light System WiringSDR 2008UALA00612Smoke Goggles · crackedCAPTAIN'S SMOKE GOGGLES BROKEN AND CRACKED. REPLACED GOGGLES. ACFT OK FOR SERVICE.Feb 3, 2008 · N659UA · Boeing 767322 · Emergency EquipmentSDR 2007UALA03366Structure · leakingLEFT MAIN FUEL QTY DECREASED WITH LT CENTER FUEL PUMP ON AND 30,000 LBS IN CENTER TANK. AFTER TROUBLESHOOTING, FOUND LT FUEL TANK DRY BAY HAS RUNNING FUEL LEAK. RESEALED LEAK AT BOTTOM STRINGER BETWEEN LEFT TANK AND OUTBOARD OF DRYBAY AT 1700. ACCOMPLISHED Aug 23, 2007 · N659UA · Boeing 767322 · Wing Main, Frame StructureSDR 2007UALA03279Indicator · faultyFLAP INDICATOR NEEDLES OUT OF LIMITS FOR FLAPS 5, 15 & 20. CHECKED FLAP POSITION TRANSMITTER NR 1 AND NR 8 RIGGING FOUND OK. CLEANED TRANSMITTER CANNON PLUGS. EXTENDED AND RETRACTED FLAPS SEVERAL TIMES USING NORMAL AND ALTERNATE MODES. BOTH IND. NEEDLES FOLAug 20, 2007 · N659UA · Boeing 767322 · Trailing Flap Position Indicating SystemSDR 2007UALA03032Door Frame · corrodedFWD CARGO PIT, FOUND CORROSION ON ANGLE FRAME INSIDE NEXT TO ROLLOUT STOP 3RD FROM MOST FORWARD POSITION AT STA 575. 08-31-07 REMOVED CORROSION VERIFIED MATERIAL LOSS WITHIN LIMIT. OK FOR SERVICE.Aug 5, 2007 · N659UA · Boeing 767322 · Fuselage Main, StructureSDR 2007UALA02940Housing · leakingCREW REPORT: FUEL BALANCE EXCEEDED 1400 LBS DURING 4 HOUR FLIGHT. TURNED ON ALL FUEL PUMPS & CHECKED FUEL TANK QTY AFTER 1 HOUR. NO LEAKS OR UNWANTED FUEL TRANSFER NOTED. CHECKED PER MM 28-11-95. LOCATED LEAK NEAR RT CTR AUX FUEL DRIP STICK NR 1 HOUSING. Jul 30, 2007 · N659UA · Boeing 767322 · Fuel StorageSDR 2007UALA02652Wire Harness · damagedELECTRICAL BURNING ODOR WITH SMOKE FROM MID GALLEY (416) AFT COUNTER HOTPLATE AREA. C/B FOR HOTPLATE H41 HAS BEEN PULLED AND BURNING ODOR AND SMOKE HAS DISSIPATED. HOTPLATE WAS NOT HOT BUT AREA AROUND HOTPLATE WAS HOT, POSSIBLE DAMAGED WIRING HARNESS. [08-1Jul 15, 2007 · N659UA · Boeing 767322 · Electrical Power System WiringSDR 2007UALA02497Hose · damagedRIGHT OFF WING ESCAPE SLIDE INFLATION HOSE FROM INFLATION CYLINDER IS CONTAMINATED WITH HYDRAULIC FLUID AND IS DETERIORATED. [08-08-07] HOSE IS DETERIORATED AND WALLS HAVE COLLAPSED FROM LONG TERM CONTACT WITH HYDRAULIC FLUID. REPLACED HOSE ASSY. SLIDE Jul 9, 2007 · N659UA · Boeing 767322 · Escape SlideSDR 2007UALA01954Light · damagedEMERGENCY FLOOR LIGHTING IN 1ST CLASS HAS BEEN TORN OFF OF FLOOR BY CATERING. [07-03-07] REPLACED EMERGENCY FLOOR LIGHTING.Jun 8, 2007 · N659UA · Boeing 767322 · Emergency LightingSDR 2007UALA01875Placard · looseEMERGENCY EXIT SIGN RIGHT SIDE LOOSE BETWEEN FIRST AND BUSINESS CLASS. [07-03-07] REPOSITIONED PHOTO LUMINESCENT AISLE PATH REF TO MM 33-50-99, CKD OKAY.Jun 6, 2007 · N659UA · Boeing 767322 · Placards and MarkingsSDR 2007UALA01464Power Supply · shortedSEAT 5C ARMREST GETTING HOT. *S/D* TROUBLESHOOTING, DISCOVERED PAX HAD SPILLED GLASS OF CHAMPAGNE OVER ARM REST. CONDUCTIVE LIQUID CAUSED INTERNAL SHORTING. C/B`S POPPED. DISCONNECTED LUMBAR CONTROL & POWER TO SEAT. REPLACED LUMBAR SWITCH PCU PCN 560-414May 10, 2007 · N659UA · Boeing 767322 · Passenger Compartment EquipmentSDR 2007UALA01340Tail Cone · puncturedTAIL CONE 18 INCH PUNCTURE AT STA 1898. [SUP 05-16-07] MAJOR REPAIR ACCOMPLISHED: MANUFACTURED & INSTALLED STRUCTURAL FILLERS AND DOUBLER REPAIR.Apr 28, 2007 · N659UA · Boeing 767322 · Aerodynamic FairingsSDR 2007UALA00509Latch · faultyLT OVERWING COMPARTMENT DOOR LATCH FAILED INTEGRATOR TORQUE TEST AT 275 INCH-LBS. REPLACED 4 SLIDE LATCHES PER MM25-65-09. DOOR TORQUE CHECK GOOD. LATCHES CHATTER IN LOCKED POSITION AND A FRET CHANNEL DEVELOPS OVER TIME.Feb 17, 2007 · N659UA · Boeing 767322 · DoorsSDR 2007UALA00508Pin · shearedRT OVERWING SLIDE PACK GUIDE PIN FOUND SHEARED WHEN SLIDE WAS REMOVED, AND REQUIRES A NEW INSERT. SUPPLEMENTAL DATA UPDATE, INSTALLED INSERT IN SLIDE PACK DOOR USING RMS5-28TY7, REF BOAC DRWG 416T2024. INSTALLED GUIDE PIN. AC RETURNED TO SERVICE STATUS.Feb 17, 2007 · N659UA · Boeing 767322 · Escape SlideSDR 2007UALA00507Feeder Cable · looseFOUND RT SEATS 29FG-35FG EEL LIGHTS INOP. FOUND FEEDER CABLE CONNECTING TO EEL TRACK LOOSE. RECONNECTED CABLE. OPS CHECKS NORMALLY.Feb 17, 2007 · N659UA · Boeing 767322 · Light System WiringSDR 2007UALA00506Feeder Cable · brokenFOUND LT 1ST CLASS EEL LIGHTS INOPERATIVE. REPAIRED BROKEN EEL CABLE. OPS CHECKS NORMALLY.Feb 17, 2007 · N659UA · Boeing 767322 · Light System WiringSDR 2007UALA00505Slide · unreliableFOUND PRESSURE LINE FOR LT OVERWING SLIDE AT BS 1153 IS KINKED AT BEND. REPLACED SLIDE. OK FOR SERVICE. SLIDE PROBLEM ROOT CAUSE: SUSPECT PRESSURE LINE MISROUTED DURING REFURBISHMENT & INSTALLATION RESULTING IN DOWNWARD LOAD ON LINE.Feb 17, 2007 · N659UA · Boeing 767322 · Escape SlideSDR 2007UALA00504Slide · unreliableRT OVERWING EXIT SLIDE, FOUND TO BE UNLACED DURING THE FIRST OPENING OF OVERWING SLIDE DOOR FOR INTEGRATOR TEST. REPLACED SLIDE. READY FOR SERVICE. SLIDE PROBLEM ROOT CAUSE: SUSPECT IMPROPER CINCHING DURING SLIDE REFURBISHING & REINSTALLATION AGGRAVATED BFeb 17, 2007 · N659UA · Boeing 767322 · Escape SlideSDR 2007UALA00495Cable · disconnectedFOUND DOORS 1R AND 2R SLIDE AFT CABLES DISCONNECTED FROM PACK BOARD. DOOR 1R & DOOR 2R SLIDES, AFT CABLES DISCONNECTED FROM PACK BOARD. BY-093796. REINSTALLED CABLES ON BOTH. OK FOR SERVICE. SLIDE PROBLEM ROOT CAUSE: SUSPECT IMPROPERLY CONNECTED DURING REFUFeb 16, 2007 · N659UA · Boeing 767322 · Escape SlideSDR 2007UALA00462O-Ring · failedLEFT OFF-WING SLIDE CYLINDER HAS LOW BOTTLE PRESSURE AND WHITE INDICATOR IS NOT IN THE ARM INDICATOR WINDOW. REPLACED CYLINDER PER MM 25-65-02. A/C READY FOR SERVICE. SUSPECT O'RINGS LEAKING DUE TO HARDENING.Feb 14, 2007 · N659UA · Boeing 767322 · Escape SlideSDR 2007UALA00214Oxygen Bottle · underservicedFOUND CREW OXYGEN PRESSURE BELOW LIMITS. SERVICED CREW OXYGEN CYLINDER. HOLDS PRESSURE; OK FOR RETURN TO SERVICE. SUSPECT PERIODIC CHECKING BY CREW DEPLETES SUPPLY.Jan 24, 2007 · N659UA · Boeing 767322 · Crew Oxygen SystemSDR 2007UALA00213Oil System · leakingDURING CLIMB TO FL 350 QTY DECREASED TO 0 CURRENTLY LEVEL AT FL350 SHOWING 0 OIL QTY L ENG.Jan 22, 2007 · N659UA · Boeing 767322 · Turbine Engine Oil SystemSDR 2007UALA00167Unknown · smokeAFTER NR 2 ENG START GROUND REPORTED SMOKE FROM BOTTOM OF ENG COWL. ENG SHUTDOWN BY CREW. SECOND START ATTEMPT NO ROTATION AND HAD R START VLV LT PER CREW. REPLACED STARTER & STARTER VALVE. SUSPECT BEARING DRAG.Jan 19, 2007 · N659UA · Boeing 767322 · Engine (Turbine/Turboprop)SDR 2006UALA00604Toilet · malfunctionedRETURNED TO IAD DUE TO A WATER LEAK IN THE MAIN CABIN. TOILET OVERFLOWED AND WATER KEPT RUNNING UNTIL CREW CLOSED LAV WATER VALVE.Mar 17, 2006 · N659UA · Boeing 767322 · LavatoriesSDR 2005UALA01318Slide · unserviceableDAMAGED BEARINGS. THIS TYPE OF EVENT HAS HAPPENED BEFORE AND BOEING IS WORKING ON IMPROVED FABRICATION MATERIALS TO ADDRESS THIS CONDITION. SLIDE WAS REMOVED FROM THE AIRCRAFT AND SENT TO THE COMPONENT SHOP WHERE BEARINGS WERE REPLACED.Nov 20, 2005 · N659UA · Boeing 767322 · Escape SlideSDR 2005UALA01238Angle · crackedNR 1 PYLON MID SPAR AT STA 233.120 RT SIDE, ANGLE IS CRACKED AT THE 2ND FROM INBOARD ATTACH FASTENER. NR 1 PYLON MID SPAR P/N 311T3157-1 AT STA 233.120 RT SIDE, ANGLE IS CRACKED AT THE 2ND FROM INBOARD ATTACH FASTENER, VERIFIED WITH HFEC. THIS IS THE CLOSE-ONov 7, 2005 · N659UA · Boeing 767322 · Nacelle/Pylon Miscellaneous StructureSDR 2005UALA01245Wire · burnedEMPENNAGE INSIDE AT BS 1809 RT SIDE BELOW CENTER HORIZONTAL STAB FEEDER WIRE BUNDLES, INSULATION NOT SECURE, LOOSE ON APU FEEDER SPLICES AND FEEDER WIRES FOUND BURNT. *S/D* THE FEEDER WIRE, SPLICE AND CONNECTOR WERE REPLACED.Nov 6, 2005 · N659UA · Boeing 767322 · APU System WiringSDR 2005UALA01246Battery · inoperativeEEL OVERHEAD LIGHTS AT SEATS 8B, 6B, 5B, 1B AND FWD OF 1B PLUS FWD LAV EEL LIGHT BAR INOP. *S/D* RESEATED BATTERY ON THE POWER SUPPLY.Nov 6, 2005 · N659UA · Boeing 767322 · Emergency LightingSDR 2006UALA01177Latch · wornR/W, O/W SLIDE COMPARTMENT, NR 4 AND 3 LATCHES ARE WORN. REMOVE AND REPLACE LATCHES IAW B767 MM25-65-98.Oct 29, 2005 · N659UA · Boeing 767322 · Emergency EquipmentSDR 2004UALA00485Stiffener · crackedSTA 246 FLOORBEAM RBL 46 FWD SIDE STIFFENER CRACKED (BUCKLED). MAJOR REPAIR ACCOMPLISHED. REPLACED STIFFENER.May 22, 2004 · N659UA · Boeing 767322 · Fuselage Main, Floor BeamSDR 2004UALA00484Fitting · crackedLEFT INBOARD T/E MAIN FLAP MIDDLE AFT FLAP HINGE FITTING CRACKED ON INBOARD SIDE NEAR FLAP AFT SPAR. INSTALLED ANGLE REPAIR.May 22, 2004 · N659UA · Boeing 767322 · Trailing Edge FlapsSDR 2004UALA00483Fitting · crackedRT WING INBOARD FLAP, MIDDLE T/E HINGE FITTING IS CRACKED AT SPAR. INSTALLED ANGLE REPAIR.May 22, 2004 · N659UA · Boeing 767322 · Trailing Edge Flaps
Back to N659UA