N663UA
Service difficulty reports · 347
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N663UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N663UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2012050702651Connector · contaminatedAIR RETURN DUE TO STAB TRIM INDICATION. TROUBLESHOOTING FOUND STAB WOULD RUN AT FULL SPEED IN NOSE UP DIRECTION AND HALF SPEED IN NOSE DOWN DIRECTION. IN BLOCK 6 OF FIM FOUND STAB WOULD NOT GO IN NOSE DOWN DIRECTION 104400 ALSO HAD 0.2 OHMS, AND IN NOSE UP DISDR UALA2012041202209Seal · leakingMAINT REPORTS FUEL LEAK FROM RT WING ACCESS PANEL INBOARD NR 5 DRIP STICK. PANEL 641KB MOLDED RUBBER SEAL DAMAGED. MOLDED RUBBER SEAL REPLACED PER AMM. FUEL LEAK CHECK PERFORMED. FOUND NO LEAK.SDR UALA2012040202051Sliding Window · defectiveCAPTAIN'S SLIDING WINDOW DEFECTIVE. REMOVED CAPTAIN'S SLIDING WINDOW IAW MM.SDR UALA2012040202053Window · defectiveCAPTAIN'S NR 3 FIXED WINDOW DEFECTIVE. REMOVED AND INSTALLED NEW WINDOW IAW MM 56-11-10.SDR UALA2012040202052Window · damagedFIRST OFFICER'S FIXED WINDOW DAMAGED. INSTALLED NEW WINDOW IAW MM.SDR UALA2012032601910Sdu · inoperativeSATCOM INOP FROM ORD TO LHR. REPLACED SDU PER MM.SDR UALA2012032001800Intercostal · gougedINTERCOSTAL IN AREA OF DAMAGE IS DENTED. REMOVED DAMAGE INTERCOSTAL. REPLACEMENT PART ON ORDER. PER ENGINEERING REMOVED 5 FASTENERS AND MAPPED OUT DAMAGE AREA FOR SKIN THICKNESS CHECK. ACCMP'D THICKNESS INSP OF BLENDED AREA, FOUND THICKNESS BLEND TO BE .046SDR UALA2012031401662Structure · damagedDAMAGE AT RT FUSELAGE STATION 1373 BELOW STRINGER 28R REQUIRES BLENDING TO REMOVE DAMAGE AND HFEC. BLENDED 4 AREAS REF SRM 53 -00-01, AND ACP'D HFEC INSPECTION OF DAMAGED AREAS REF NDT MAN PART 6 FOUND NO CRACKS. TWO UPPER DAMAGED AREAS OUT OF SRM ALLOWABLE SDR UALA2012031201633Computer · faultyRIGHT ELEVATOR POSITION INDICATION INOP DURING FLT CONTROL CHECK. ALL 3 HYD SYSTEMS PRESSURIZED. CYCLE FCC AC CB'S, NO HELP. SWITCHED EICAS COMPUTER FROM LEFT, RIGHT AND BACK TO AUTO, NO HELP. VERIFIED OPERATION 908-12. RPL'D LEFT EICAS COMPUTER PER MM, CSDR UALA2012030801520Iru · faultyLEFT IRS FAULT ON ALIGNMENT. REPLACED LEFT IRU PER MM, ACCOMPLISHED TEST 30 PER MM. OPS CHECK GOOD.SDR UALA2012020600689Actuator · faultyRUDDER RATIO LIGHT & EICAS MSG, RTFL. FAULT BALL FOUND IN PCA POSTION ON BOTH RRCM'S. REPLACED RRCA WITH BORROWED PART S-N 1008. OPS CHECKS GOOD, NO FAULTS.SDR UALA2012012400505Anti-Ice Valve · faultyLEFT ENG ANTI-ICE VALVE LIGHT ON. VERIFIED SOLENOID AND VALVE OPERATION PER MEL ITEM 3021C. MEL REF: 3021C. PARTS: 643-9002 MR30133 VALVE ASSY. REPLACED WITH NEW TAI VLV, OPS CHECKED NORMAL PER MMSDR UALA2012012300476Unknown · malfunctionedLEFT ENG ANTI ICE VALVE LT ON WITH ENG SHUT DOWN AND SWITCH IN OFF POS. CLEANED ELEC CONNECTOR ON ENG INLET THERMAL ANTI-ICE VLV. LIGHT EXTINGUISHED. PROBLEM RECURRED.SDR UALA2011121906971Door · openAT DEPARTURE CENTER FUEL PUMPS REMAINED ON WHEN THEY SHOULD HAVE SHUTOFF. FOUND FUELING DOOR AJAR SECURED FUELING DOOR, OPS CKS OKAY.SDR UALA2011121406870Thrust Reverser · damagedFOUND RT ENG INB TR DAMAGED AND STRUT FAIRING COVER MISSING AT THE 9 O'CLOCK POSITION. DAMAGE IS APPROX 7"X .5" WIDE WITH A DEPTH OF .5". PER AVO #1103 COMPLETED REPAIR STEPS 1-5. SEALANT NEEDS TO BE CONFIRMED CURED AND STEP 6 & 7 NEED TO BE COMPLETED. REF ESDR UALA2011113006566Battery · activatedEEL LIGHTS ON SEATS 19J THRU 22J ARE INOP. REPLACED CHARGER AND BATTERY, CHECKS GOOD.SDR UALA2011113006565Light · inoperativeEXTERNAL EEL LIGHT INOP BY NR 1 RIGHT DOOR. REPLACED LIGHT ASSY, CHECKS GOOD.SDR UALA2011110706072Actuator · out of adjust5 UNITS LEFT RUDDER TRIM NEEDED BOTH AT CRUISE AND DESCENT. ADJUSTED TOP RUDDER PCA FOR CTR SYS INPUT ROD PER MM. AIRCRAFT TRIM DISCREPANCY CHECK ACCOMPLISHED PER MM.SDR UALA2011110706071Unknown · malfunctionedRT ELEVATOR MOVEMENT INDICATOR DOESN'T MOVE. DEFERRED PER SAMC. IF NEEDED REPLACE XMTR PER MM. RPL : TROUBLESHOOT PER FIM 27-3 1-00, NO FAULTS FOUND. REPLACED RIGHT ELEVATOR POSITION CB (4102 ) PRECAUTIONARY. ELEVATOR POSTION INDICATONS ARE NORMAL.SDR UALA2011110706066Transmitter · faultyAT CRUISE, LEFT OIL PRESS FLUCTUATED FROM 190-400,THEN STAYING FROM 350-400. ALL ELSE NORMAL. REPLACED NR 1 ENG OIL PRESSURE TRANSMITTER PER MM. ACP'D ENG RUNS AND OIL PRESSURE INDICATIONS NORMAL. NO LEAKS NOTED.SDR UALA2011101705606Light · inoperativeCOCKPIT EMERGENCY LIGHT INOPERATIVE. REPLACED EMERGENCY LIGHT ASSY, OPS CHECKED OKAY.SDR UALA2011092905279Actuator · leakingON ARRIVAL FOUND EVIDENCE OF HYDRAULIC LEAKING LEFT SIDE FUSELAGE BY APU. FURTHER INVESTIGATION SHOWED FLUID COMING FROM LOWER RUDDER AFT TRAILING EDGE DRAIN HOLE. FOUND UPPER RUDDER PCU PISTON SEAL LEAK POINT SEAPING UNDER 5 DROPS PER MINUTE AND CYCLE.SDR UALA2011091204942Adapter · leakingFUEL LEAK FROM THE TOP OF LEFT ENGINE FROM THE FUELING LINES. MAINT TEXT: DURING FUELING OPERATION, FUEL LEAKING FROM PYLON DRAIN AND IMMEDIATELY OUTBOARD OF FWD PYLON AREA ADJACENT TO L/E SLAT. FOUND FUEL LEAKING AT INBD FUELING ADAPTER, TIGHTENED ALL BOLTSSDR UALA2011090904871Cooling Fan · inoperativeEQUIPMENT COOLING OVERHEAT. REPLACED EQUIP COOLING SUPPLY FAN 1 DUE TO PRIOR HISTORY, VIBE SENSOR TRIPS NEW SUPPLY FAN, TRIED NEW VIBE SENSOR, STILL TRIPS NEW FAN. ORDERED ANOTHER NEW FAN OSTF U4874, NEED TO REPLACE FAN AGAIN.SDR UALA2011090704853Skin · damagedFUSELAGE DAMAGED RT SIDE JUST AFT OF WING TO BODY FAIRING. GOUGED STA 1197 & 48 BETWEEN STRINGERS 32R AND 33R GOUGE IS 17 INCHES LONG BY 1-4 INCH WIDE AND 3-8 INCH AT THE DEEPEST POINT. PHOTOS ON THE RVI SITE. DAMAGE WAS CUTOUT AND RPR'D REF SRM RPR 14 BY ISDR UALA2011081504322Shutoff Valve · failedLT ENG BLEED VALVE STUCK CLOSED ON GROUND. BITE TEST OF AIR SUPPLY MODULE FAULTS "PRSOV". REPLACED PRSOV FAILED HEALTH CHECK. REPLACED PRSOV. RAN NR 1 ENG PRSOV, OPERATES NORMAL.SDR UALA2011080404074Windshield Wiper · defectiveF/O WINDSHIELD WIPER WON'T STOP. ALSO THE CAPT'S OUTER PORTION OF WINDSHIELD WIPER DOES NOT CLEAN RAIN FROM WINDOW. REPLACED F/O WIPER ARM ASSY IAW MM. REPLACED CAPT'S WIPER BLADE. OPS CHECK NORMAL.SDR UALA2011080304059Idg · failedELEC GEN DRIVE R RIGHT IDG FAULT (LOW INTERNAL OIL PRESSURE). REPLACED IDG PER MM AND ALSO REPLACED IDG DRIVE SEAL.SDR UALA2011080204005Idg · failedCREW REPORT: JUST PRIOR TO TAKING RUNWAY L AC BUS FAILED. ACP TROUBLESHOOTING PER TABLE 102 REF MM P163 FOR DP TRIP AND MAIN BUS-OVERLAP. ALL WIRE CHECKS SAT. CREW ALSO REPORTED THE LEFT GENERATOR CONTROL TRIPPED AND THE LEFT TIE BUS ALSO FAILED. BOTH THESDR UALA2011080103925Idg · failedPER INBOUND CREW, LEFT BUSS TRIPPED ON THROTTLE ADVANCE DURING T/O. RESET AS REQUIRED. ITEM HAS HISTORY. DUE HISTORY OF THIS FAULT, THIS ITEM IS GENERALLY CAUSED BY A DEFECTIVE IDG. SUSPECT IDG INSTALLED BY PREVIOUS STATION FOR ANOTHER TYPE FAULT, NEEDS RPSDR UALA2011080103924Idg · disconnectedLEFT GENERATOR DRIVE EICAS & DRIVE LIGHT ON DRIVE DISCONNECTED. REPLACED NR 1 ENGINE IDG, OPS CHECKED NORMAL.SDR UALA2011080103923Ignition Sys · failedAPU WILL NOT START. REPLACED IGNITION UNIT.SDR UALA2011080103922Battery Pack · faultyEXIT SIGN DOOR 1R AS WELL AS FLOOR LIGHTING STRIP BY SAME DOOR ARE FLASHING ON AND OFF. REPLACED POWER SUPPLY BATTERY PACK M1552, OPS CHECKED OKAY.SDR UALA2011062703168Connector · unsecureEMERGENCY LIGHT ON SEAT 19K IS INOPERATIVE. SECURED SEAT CONNECTOR, CHECKED GOOD.SDR UALA2011062703167Battery Pack · inoperativeEMEGENCY LIGHT BY FWD GALLEY IS INOPERTIVE. REPLACED BATTERY, WORKS NORMAL.SDR UALA2011062703166Battery Pack · inoperativeSMALL EMERGENCY EXIT SIGN BY DOOR 1 RIGHT IS INOPERATIVE. REPLACED BATTERY, WORKS NORMAL.SDR UALA2011062703165Light · inoperativeEMERGENCY LIGHT ABOVE FLIGHT DECK DOOR IS INOPERATIVE. RESEATED LIGHT ASSY. WORKS NORMAL.SDR UALA2011062703164Lamp · inoperativeEXTERNAL EEL LIGHT ON AFT RT DOOR IS INOPERATIVE. RELAMPED & REPLACED POWER SUPPLY ASSY, WORKS NORMAL.SDR UALA2011052002492Unknown · malfunctionedFLAP LT ON FMA W-FLAPS IND UP & VERIFIED UP VISUALLY AT 250 KTS. FMA CLR'D LATER. *SUPPLEMENTAL DATA UPDATE* PERFORMED MCDP GRD TEST PER MM, FOUND LAST FLT FAULTS, AP CTR MODE ERR, DIAGNOSTIC CODES, 110780, 120780, 130780, NO CURRENT FAULT ON TEST 30, FLAP SDR UALA2011051802443Switch · faultyCREW REPORTED CENTER TANK RIGHT FUEL PUMP PRESSURE LIGHT IS NOT ON WITH PUMP SELECTED ON PRIOR TO START. REPLACED THE LOW PRESSURE SWITCH S424 PER AMM. NO LEAKS NOTED. PRESSURE SWITCH SWAPPED FROM S806 R FUEL JETTISON PUMP. LOW PRESSURE SWITCH S806 INOP. RSDR UALA2011040101576Pump · faultyPRIOR TO START RIGHT CENTER FUEL PUMP SHOWED ON. DEFERRED RT CENTER FUEL PUMP AS PER MEL 2822H. ACP TEST OF RT CT OVERRIDE JETTISON PUMP PER MM, TEST OKAY. OPERATED PUMP TO TRANSFER FUEL FROM THE AUX TANK TO LEFT AND RIGHT MAIN TANKS, PUMP OPERATED OKAY. SDR UALA2011021600813Skin · missingRT ENGINE REAR STATOR MISSING WHOLE LOWER SKIN, UPPER SKIN BEGINNING TO COME OFF. INSPECT INTERMEDIATE CASE STRUT FAIRING IAW MM. INSPECTED COMPRESSOR INTERMEDIATE CASE STRUT AT 3 O'CLOCK POS. LOWER FAIRING MISSING. DAMAGE. CF IAW AMM.SDR UALA2011021000702Charger · faultyMAIN BATTERY CHARGER STATUS MSG WILL NOT CLEAR. CHANGED APU CHARGER WITH MAIN BATTERY CHARGER. STATUS MESSAGE CLEARED, CHARGER OPERATES SATISFACTORY.SDR UALA2011012800493Oxygen Mask · misinstalledOXYGEN MASK INSP FOUND NUMEROUS O2 MASKS NOT PROPERLY PACKED. REPACKED AND STOWED 416 PASSENGER O2 MASKS IAW MM.SDR UALA2011012600436Light · missingRT REAR ENTRY DOOR IS MISSING EMERGENCY LIGHT ILLUMINATION FOR DOOR RELEASE HANDLE. REPLACED RT REAR (4RT) EMERGENCY LIGHT ASSY. OPS CHECKS GOOD.SDR UALA2010122704713Shutoff Valve · intermittentBLEED AIR DUCT PRESSURE INTERMITTENTLY SURGING BTWN 20-40 PSI AT ALTITUDES BELOW 8000 FT. OCCURRED TWICE ON CLIMB POWER SETTINGS (1.46 EPR). ON ARRIVAL IDLE POWER (1.02-.99EPR) WITH BOTH ISOLATION VALVES CLOSED AND RT PRESSURE WAS SLIGHTLY HIGHER SURGING. SEEMSDR UALA2010121304545Windshield · failedWINDOW EICAS MESSAGE DISPLAYED. INOP LIGHT ILLUMINATED & DID NOT EXTINGUISH WHEN SWITCH WAS RECYCLED TO OFF/ON. SWAPPED WINDOW HEAT CONTROLLER, NO HELP. SUSPECT BAD WINDOW. WINDSHIELD CONTROL BITE FAILED, UNIT REPLACED; NOW FAULTS WINDOW 3R. INTERNAL RESISTASDR UALA2010121304540Circuit Card · faultyRAMP REPORTED WHILE TOWING ACFT TO GATE EQUIPMENT COOLING HORN CAME ON AND AT GATE FOUND FWD EQ SUP FAN 1 STATUS MESSAGE. T-S IAW FIM 21-23-08 PAGE 107 BLOCK 6, WILL NEED RELAYS K1325, K1326 TO CONT. T-S. REPLACED RELAY K1319 AND NO HELP. REPLACED M876 EQUIP SDR UALA2010121304538Control Unit · faultyRECENT HISTORY OF 'SPOILER' EICAS MSG WITH 'PCA' FAULT BALL SET ON SCM 2L. DUE TO RECENT HISTORY OF 'SPOILER' EICAS MSG WITH 'PCA' FAULT BALL SET ON SCM 2L. DUE TO SUCCESSFUL RESET AFTER REMOVAL & CLEANING OF PCA CONNECTORS; REMOVE INSPECT AND REPLACE IF NECESDR UALA2010101903865Drain Valve · leakingRIGHT TANK FUEL SUMP HAS FUEL SEEP AT OUTER CIRCUMFERENCE. REPLACED RT TANK SUMP DRAIN VALVE. OPS NORMAL.
Back to N663UA