N663UA
Service difficulty reports · 347
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N663UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N663UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2013100291656Control Panel · damagedHEADING SELECT KNOB FALLING APART. HEADING SELECT INOPERATIVE. MODE CONTROL PANEL REPLACED IAW AMM 22-11-02, MCDP TEST 04 CARRIED OUT, ALL SATISFACTORY.SDR CALA2013090691073Control Panel · inoperativeHDG SELECT BINDS WITH BANK LIMIT. MODE CONTROL PANEL SECTOR BANK LIMIT SELECTOR INOPERATIVE. REPLACED MODE CONTROL PANEL IAW MM. TEST CHECKED GOOD.SDR UALA2013072305171Duct · splitRIGHT PACK COMPRESSOR OUTLET DUCT SPLIT AT COMP OUTLET TEMP SENSOR BOSS. REPLACED DUCT ASSY, LEAK CHECKED AND TESTED IAW MM 21-51-00 PG 501 ALL GOOD. REPLACED ELBOW FITTING & ACCOMPLISHED PACK TEST WRT MM. ALL INDICATIONS CHECKED OK. ALSO LEAK CHECK ACCOMPLISDR UALA2013071604991Pump · malfunctionedLEFT CENTER FUEL PUMP ON WITH ENGINES SHUTDOWN AT GATE.SDR UALA2013071104848Pressure Switch · malfunctionedLEFT FUEL PUMP LOW PRESSURE LIGHT DOES NOT COME ON. CLEANED AND INSPECTED LT CENTER FUEL PUMP PRESSURE SWITCH. ACCOMPLISHED FUEL PRESSURE INDICATING OPS CHECK.SDR UALA2013070804738O-Ring · failedHYDRAULIC FLUID DRIPPING FROM RT WING INBD OF RT ENGINE PYLON. REMOVED UNDER WING PANELS ON RT SIDE NEAR INBD CANOE. ACCOMPLISHED CHECK IAW MM 29-11-00. OPERATED ALL CONTROLS SPOILERS AND FLAPS NO LEAKS FOUND, QTY 0.95 & STEADY. ACCOMPLISHED STATIC LEAK CSDR UALA2013062704508Line · leakingHYD LEAK, RT WING JUST INBD OF INBD AILERON. FOUND DC MOTOR OPERATED SHUTOFF LATERAL CONTROL EMPENNAGE VALVE LEAKING. CYCLED LATERAL CONTROL VALVE, AND TIGHTENED PRESSURE LINE, NO LEAKS NOTED.SDR UALA2013062004288Line · leakingFOUND LEAK ON FLEX LINE BETWEEN STAB TRIM CONTROL MODULE AND STAB TRIM ACTUATOR. REPLACED LINE, LEAK CHECKED NORMAL.SDR UALA2013061804231Actuator · leakingLEFT HYDRAULIC SYS DOWN TO .85 ON ARRIVAL. NOTED HYD FLUID ON TAIL AREA OF ACCESS PANEL TO HORIZONTAL STABILIZER. SERVICED HYD SYS TO FULL. CLEANED TAIL AREA ENTERED ACCESS PANEL TO HORIZONTAL STABILIZER BAY FOUND LEFT AP ELEVATOR SERVO ACTUATOR ROD LEAKINGSDR UALA2013052403605Sdu · failedSATCOM INTERMITTENT. CALLS TO DISPATCH DO NOT STAY CONNECTED. REPLACED SDU IAW AMM, GROUND CHECKS NORMAL.SDR UALA2013042402846Inlet · dentedNR 1 ENGINE INLET COWL DENTED. REPAIRED.SDR UALA2013042402845Fairing · delaminatedRIGHT ENGINE PYLON INBD AFT FAIRING HAS DELAMINATION. PERFORMED METAL BOND REPAIR PER AMM.SDR UALA2013042202781Fastener · missingWHILE PERFORMING MF8840, FOUND ONE MISSING FASTENER ON NR 2 ENGINE OUTBD PYLON HEATSHIELD. REPAIRED.SDR UALA2013040302179Satcom · faultyNO COMM DISPLAYED ON ACARS DISPLAY UNIT OVER OCEAN, ACARS SENDS OK IN VHF RANGE. ACCOMPLISH CHRONIC REVIEW. PLACARD SATCOM DUE TO HISTORY PER 2325A, C-B'S COLLARED. REMOVED AND REPLACED SAT DATA UNIT IAW AMM. OPS CHECK GOOD REF 23-25-00. SEE 8262003 FOR PSDR UALA2013040202122Display · failedUPPER EICAS FAILED. REMOVED AND REPLACED UPPER EICAS DU, OPS CHECK NORMAL.SDR UALA2013040102069Relay · faultyCAPT PITOT LIGHT AND EICAS MESSAGE ON ENGINE START. REPEAT WRITE-UP. RELAY K241 PART N.770540- 2 AND K516 PART N. BACR13CG2A. REPLACED SPEED CARD TEST PERFORMED IAW AMM. PITOT HEAT TEST PERFORMED IAW AMM.SDR UALA2013032802009Display · intermittentNO COMMS DISPLAYED ON ACARS DISPLAY UNIT, OVER OCEAN. ACARS SENDS OK IN VHF RANGE. REPLACED SDU PER AMM, GROUND CHECKED NORMAL.SDR UALA2013031101425Doubler · dentedDENT ON EXISTING DOUBLER REPAIR 2 INCHES BELOW STR 16L BS 768. MAJOR REPAIR ACCOMPLISHED. REMOVED EXTERNAL REPAIR DOUBLER 2 INCHES BELOW STR 16L AT BS 768 IAW B757-200 SRM 51-40-02 FIG 8. FABBED, LOCATED, AND DRILLED DOUBLER AND FILLER IAW B757- 200 SRM 53-SDR UALA2013031101405Latch · brokenFWD CARGO DOOR, CARGO HANDLING PANEL, BOTTOM LATCH BROKEN. DEF PER CDL. REMOVED DOOR AND STOWED IN FORWARD CLOSET IN CABIN. REPLACED LATCH AND SECURED ACCESS PANEL TO FWD CARGO CONTROL AREA.SDR UALA2013030501315Lock Ring · missingLOCKING RING MISSING FROM BOTTOM PANEL OF COCKPIT DOOR. REPLACED LANYARD RINGS.SDR UALA2013021400868Control Panel · no testWEATHER RADAR TEST MODE DOES NOT TEST PROPERLY. TEST MODE CONTINUES TO DISPLAY AND, UNABLE TO DE-SELECT. REPLACED WEATHER RADAR CONTROL PANEL AS PER MM AND ACCOMPLISHED SYSTEM TEST AS PER MM.SDR UALA2013013000562Connector · unsecureCOCKPIT TEMP EICAS. BITE CHECK AUX ZONE CONTROLLER, SHOWS CTR YEP CONTROL FAULT. FOUND CONNECTOR ON CTR AUX TEMP SELECTOR LOOSE. SECURED CONNECTOR, BITE CHECK ZONE CONTROLLERS, NO FAULTS. CLEARED EICAS MSG. SIGN OFF TEXT SHOULD STATE: SECURED CONNECTORS INSDR UALA2012122807447Insulation · delaminatedNR 2 ENGINE THRUST REVERSER LEFT HALF HAS DELAMINATED FIRE SEAL INSULATION ON LOWER QUADRANT. RE-ADHERED FIRE SEAL INSULATION TO INNER THRUST REVERSER HALF ON LOWER QUADRANT. FIRE SEAL IS STILL IN PARTIAL CURE. ALL SEAMS MUST BE SEALED. THERE IS A PART OF THESDR UALA2012121707264Stator · faultyRIGHT ENGINE EEC C1 STATUS MSG, RTFL. REPLACED NR 2 ENGINE EEC ALTERNATOR STATOR. RAN ENGINE, NO MESSAGES, INDICATIONS NORMAL.SDR UALA2012121707255Gcu · faultyRIGHT GENERATOR TRIPPED OFF-LINE JUST AFTER TAKEOFF. A/C POWER AVAILABLE FROM APU. FLIGHT CONTINUING TO MUC. TOMC PLANNING TO DEFER RIGHT ENGINE GENERATOR IN MUC. REPLACED APU GCU.SDR UALA2012121207202Sdu · faultyVOICE ON SATCOM NOT WORKING. ACARS CAN USE OK. MSG "LOW GAIN" ON LINE 6 OF CDU. REPLACED SATELLITE DATA UNIT PER MM. CALLED SAMC, OPS CHECKED NORMAL.SDR UALA2012121207201Idg · faultyRIGHT GENERATOR OFF, RESET DID NOT WORK. REPLACED IDG PER MM. RAN ENGINE LOADED GENERATOR TO 71%. OPS CHECKED GOOD. RE-SERVICED IDG AND ACCOMPLISHED LEAK CHECK. NO LEAKS FOUND.SDR UALA2012121207176Power Unit · faultyUNABLE TO OPEN AFT CARGO PIT DOOR EITHER MANUALLY OR ELECTRICALLY. REPLACED AFT DOOR LIFT LATCH POWER UNIT, OPS CHECK GOOD.SDR UALA2012120406952Eec · faultyCREW REPORTS THEY HAVE A "R ENG EEC C1" STATUS MSG. TRIED TO CYCLE THE SYSTEM, ENGINE SHUTDOWN AND RESTART. MSG CLEARED WITH RESTART OK. TO DEFER PER MEL 7321H. BITE FAULT CH A N2 RANGE FAIL. REPLACED RIGHT ENG EEC REF MM 73-21-04 RAN ENG NO STATUS MESSAGE.SDR UALA2012110906450Skin · damagedE+E DOOR, EXTERIOR SKIN FOUND TO HAVE MINOR PITTING. ORIGINAL MATERIAL THICKNESS IS .050", MATERIAL REMAINING AFTER BLENDOUT IS .039" RIGHT SIDE & .044" LEFT SIDE. FABRICATED AND INSTALLED 2 EACH REPAIR DOUBLERS PER SRM 52-40-01, REPAIR 5, ON NON ROUTINE 468SDR UALA2012110906449Floorbeam · corrodedBS 303 RBL 54 TRANSVERSE FLOORBEAM UPPER CHORD CORRODED (TOP SIDE). MATERIAL REMAINING OUT OF LIMITS PER SRM 53-00-01 IN 5 AREAS BETWEEN RBL 37 TO RBL 63. REMOVED DAMAGED SECTION OF T-CHORD AND FABRICATED AND INSTALLED REPAIR ANGLES, STRAPS, SHIMS AND CLIPS SDR UALA2012110906448Lap Joint · damagedBS 1582 LAP SEAM APPEARS TO BE UNEVEN, ENTIRE CIRCUMFERENCE OF FUSELAGE, AFT PRESSURE BULKHEAD ATTACHMENT POINT. MAINT TEXT: ACCOMPLISHED ALL REQUIRED INSPECTIONS AND ACCOMPLISHED STRINGER SHIMMING REPAIRS AT THE FOLLOWING LOCATIONS: SECTION 46, STR'S 3R, 12SDR UALA2012110906445Fitting · damagedBS 1582, STRINGER END FITTING AT STRINGER 34 LEFT, SECTION 46 IS DAMAGED. MAJOR REPAIR ACCOMPLISHED: REPLACED THE STRINGER 34 LEFT END FITTING, P/N 146T0307Y1 AND LOCATED AND DRILLED PER SRM AND INSTALLED PER SRM.SDR UALA2012101705922Skin · damagedMJR RPR. LOWER EXTERNAL FUSELAGE SKIN TOOLING DAMAGE BETWEEN BS 1329-1351 AT STR 35L-36L. BLENDED OUT DAMAGE & FOUND MATL LOSS OUT OF SRM LIMITS. CUT OUT DAMAGE & ACP HFEC REF NDT MAN 51-00-19. NO DEFECTS. FABRICATED & INSTALLED AN EXTERNAL DOUBLER & FILSDR UALA2012101705921Skin · damagedUNDER PAINT TOOLING BLENDOUT AT STR 2 RIGHT NEXT TO THE TCAS ANTENNA. EVALUATED DAMAGE & FOUND MATERIAL LOSS OUT OF SRM LIMITS. CUT OUT DAMAGE & ACP HFEC REF NDT MAN 51-00-19. NO CRACKS. FABRICATED & INSTALLED EXTERNAL DOUBLER & FILLERS REPAIR REF SRM 53-0SDR UALA2012101805974Skin · damagedUNDER PAINT TOOLING BLENDOUT AT STR 2 RIGHT NEXT TO THE TCAS ANTENNA. EVALUATED DAMAGE & FOUND MATERIAL LOSS OUT OF SRM LIMITS. CUT OUT DAMAGE & ACP HFEC REF NDT MAN 51-00-19. NO CRACKS. FABRICATED & INSTALLED EXTERNAL DOUBLER & FILLERS REPAIR REF SRM 53-0SDR UALA2012101705920Skin · crackedEXTERIOR FUSELAGE LOWER SKIN LEFT SIDE DENTED, BS 610 - BS 632, STR 32L - STR 33L. EVALUATED DENT & FOUND CRACKED OUTER SKIN. CUT OUT DAMAGE & ACP NDT OF CUT-OUT REF NDT MAN 51-00-19. FABRICATED & INSTALLED EXTERNAL DOUBLER & FILLER REPAIR REF SRM 53-00-01.SDR UALA2012101005743Floorbeam · corrodedMAIN CABIN FLOORBEAM AT STA 852 AT RBL 74.81 UPPER SURFACE HAS CORROSION. MAJOR REPAIR ACCOMPLISHED: CORROSION IS OUT LIMITS IAW SRM 53-00-51, PG 102. FABRICATED & INSTALLED T-CHORD, FILLER & SPLICE ANGLE IAW SRM 53-00-51, REPAIR 3.SDR UALA2012101005742Shear Tie · corrodedAFT CARGO COMPARTMENT BILGE, SHEAR TIE CORRODED BS 1395 - 1396, STR 39L - 39R. MAJOR REPAIR ACCOMPLISHED: REMOVED CORROSION, FOUND TO BE OUT OF LIMITS. FABRICATED & INSTALLED NEW SHEAR TIE IAW SRM 51-40-02.SDR UALA2012101005741Shear Tie · corrodedAFT FUSELAGE LOWER INTERNAL BILGE AREA WEB TIES CORRODED AT SEVERAL AREAS BS 1540, STR 36R - STR 39R. MAJOR REPAIR ACCOMPLISHED: REMOVED CORROSION ON SHEAR TIE STA 1540 BETWEEN STR 39R-38R, ARE OUT OF LIMITS. INST 3EA NEW SHEAR TIES STA 1540, STR 36R-39R IASDR UALA2012101005740Structure · dentedBULK CARGO DOOR FWD LOWER CORNER HAS 6 EA DENTS 1" TO 5.5" FROM FWD EDGE, 1.5" TO 6.25" FROM BOTTOM EDGE. DAMAGE FOUND TO BE OUT OF LIMITS IAW SRM 52-30-01, DET VI NOTE J. REPAIRED IAW SRM 52-30 -01, FIG 201. THIS REPAIR IS CATEGORY A.SDR UALA2012092105349Indicator · out of toleranceAFT RIGHT DOOR LOAD LIMITER INDICATOR NUT OUT OF LIMITS, MORE THAN 1-8 INCH FROM HOUSING. REMOVED AND REPLACED AFT RIGHT DOOR LOAD LIMIT INDICATOR IAW B767 AMM.SDR UALA2012083104914Gcu · poppedRIGHTT ENGINE IDG VALVE C/B POPPING. THIS IS M31 CB(28VDC). IT IS CHRONIC AND MEL 7521D CANNOT BE USED TO DF THE RIGHT IDG VALVE, DUE TO STATING AFTER DEACTIVATION OF THE VALVE PUSH THE C/B IN. THIS ITEM NEEDS TO BE FIXED OR PROVISION OF MEL GET CHARGED. RSDR UALA2012082904861Warning Message · illuminatedRIGHT WING SLIDE DOOR EICAS MESSAGE.SDR UALA2012083104921Charger · faultyDURING PREFLT EICAS MESSAGE MAIN BATTERY CHARGER ON STATUS PAGE CANNOT ERASE. REMOVED & REPLACED BATTERY CHARGER, OPS CHECKS GOOD.SDR UALA2012082804837Wire · damagedOFF GATE, AFTER ENG START, CIRCUIT BREAKER M31 FOR RT ENGINE IDG VALVE TRIPPED. REPLACED CIRCUIT BREAKER AS PRECAUTION. WIRE W3538-017-20 REPLACED. PERFORMED ENGINE IDLE RUN FOR 5 MINUTES ALL INDICATIONS NORMAL. WIRE REPLACED IAW SWP AND WDM 24-11-21.SDR UALA2012082104682Oil Cooler · faultyCB M31 POPPED OUT WITH NO FURTHER INDICATIONS DF420. IDG AIR OIL COOLER DEACTIVATED IN OPEN POS SECURED TO CLOSE BY ELECTRICAL HARNESS. CB PULLED AND SECURED. REPLACED IDG AIR OIL HEAT EXCHANGER AND VLV NO LEAKS, NO FAULTS, NO MESSAGES.SDR UALA2012080604206Transmitter · leakingNR 1 ENG OIL PRESSURE INDICATION FAULT, TEMPERATURE AND QUANTITY NORMAL; OIL PRESSURE FLUCTUATING OR INTERMITTENT. WENT TO 400 PSI AFTER CLIMB POWER SELECTED INTERMITTENT NORMAL TO 400 PSI. NO LEAKS FOUND AFTER OIL PSI TRANSMITTER REPLACED. STATIC RUN CHESDR UALA2012071103737Slide · damagedDOOR 1R EVACUATION SLIDE BUSTLE HAS DAMAGE FROM GALLEY CONTAINER. BUSTLE HAS PUNCTURE APPROX 2 BY 2 INCHES LOCATED 6 INCHES FROM BOTTOM OF BUSTLE ON TRAILING EDGE, TWO GOUGES APPROX 18 INCHES AND 24 INCHES FROM BOTTOM OF BUSTLE. REMOVED BUSTLE AND INSPECTED SDR UALA2012061503293Actuator · faultyRIGHT PACK INOP, LIGHT ON. EICAS MSG 'RIGHT PACK TEMP 'DISPLAYED. PERFORMED BITE CHECK THAT REVEALED BAD PACK EXHAUST ACTUATOR. REMOVED AND REPLACED RIGHT PACK EXHAUST ACTUATOR. WORKS OK. NO FAULTS.