N768UA
Service difficulty reports · 221
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N768UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N768UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2009021700498Light · inoperativeLIGHT IN RT ENGINE FIRE SHUT-OFF SWITCH HANDLE IN CTR PEDESTAL DOES NOT ILLUMINATE DURING FIRE TEST. REPLACED RIGHT ENG FIRE CONTROL MODULE. ALL CHECKS AND INDICATIONS NORMAL.SDR UALA2009020200357Structure · bentRAMP DAMAGE AFT LARGE CARGO DOOR. CLOSING AND AFT LOWER CORNER CAUGHT THE LOADER RAILING BENT. REPAIRED PER SRM 52-30-01 4A AND 4B. HFEC INSP NO CRACKS FOUND.SDR UALA2009020200351Light · inoperativeEXT EMERGENCY LIGHT AT DOOR 2L IS OUT. RELAMPED EMERGENCY LIGHT, LIGHT OP CHECKS OK.SDR UALA2009012800308Controller · failedTHREE RIGHT PACK WENT INOP.SDR UALA2009012800307Duct · crackedRT ENG BLEED AIR SUPPLY DUCT CRACKED AT CONN TO RT PACK SUPPLY LINE. NEW DUCT IN HAND, INSTALLING NOW. CLOSE UP TO FOLLOW. OPS CHECKS GOOD AFTER REPLACEMENT OF RT ENG BLEED AIR SUPPLY DUCT DUE TO CRACKS.SDR UALA2009011300148Acm · faultyRT PACK TRIP AND ACM FAULT, LT PACK EICAS MSG STBY MODE AND ACM. STRONG ELECTRICAL-BURNING ODOR IN CABIN ON PACK FAILURE. REPLACED LT AND RT ACM. GROUND TESTS NO FAULTS.SDR UALA2008120806786Pressure Sensor · defectiveAPU FAILED DURING STARTING, AUTO SHUTDOWN (TWICE). REPLACED DELTA PRESSURE SENSOR, TOTAL PRESSURE SENSOR AND SURGE CONTROL VALVE. RAN APU AND DRY MOTORED ENGINE, OPS OK.SDR 2008UALA03631Unknown · smokeLAV COMPARTMENT DOOR DAMAGED AND LAV WASTE CONTAINER DAMAGED DUE TO SUSPECT LAV SMOKE IN LAV WASTE CONTAINER.SDR 2008UALA02614Bearing · making metalMETAL DEBRIS FOUND ON NR 2 ENG MAGNETIC CHIP DETECTOR. SEM CONFIRMED BEARING MATERIAL. A/C FERRIED TO SFO FOR ENGINE CHANGE. ENGINE REPLACED AT SFO ON 5/4/08. SHOP TEARDOWN REVEALED THAT THE NR 1 BEARING HAD ONE BALL WITH A LARGE AREA OF SPALLATION, AND ITSSDR 2008UALA02334Bottle · reads lowLOW BOTTLE. SUPPLEMENTAL, FILLER VALVE LOOSE. TIGHTENED FILLER VALVE AND TOPPED OFF CYLINDER.SDR 2008UALA02335O-Ring · leakingLOW BOTTLE. SUPPLEMENTAL, GAUGE FITTING BACK UP RING LEAKS. REPLACED BACK UP RING.SDR 2008UALA02003Light · missing1F MISSING 1 AFT EMERGENCY LIGHT STRIP. SUPPLEMENTAL DATA UPDATE, REPLACED LIGHT STRIP.SDR 2008UALA01828Slide · low pressureDOOR 2L SLIDE PRESSURE GAUGE BELOW GREEN BAND.SDR 2008UALA01590Light · inoperativeEEL LIGHT INOP 2F AFT POSITION. REPLACED EEL LIGHT IN SEAT 2F AFT POSITION.SDR 2008UALA01490Connector · bentTHE 4R DOOR EPAS RESERVOIR ELECTRIC PLUG PIN BENT.SDR 2008UALA01461Skin · delaminatedNR 11 SLAT OUTBOARD EDGE UPPER AND LOWER SURFACES DELAMINATED.SDR 2008UALA01460Skin · delaminatedNR 9 SLAT O/B EDGE DELAM ON UPPER AND LOWER SURFACE.SDR 2008UALA01440Panel · wornRIGHT O/B FLAP, UPPER SKIN PANEL IS WORN AT OUTBOARD END. REPAIR PER EN-57- 0028-01 AND EVA-71269. THE REPAIR IS APPROVED BY MANUFACTURER. THE REPAIR IS 12 MONTH LIMITED REPAIR AND A NEW 8100-9 MUST BE ISSUED TO COMPLY WITH 14 CFR 25.5 71 AND 26.43(D). OK TO SDR 2008UALA01439Skin · wornLEFT O/B FLAP I/B END, 12 FROM FRONT END, SKIN IS WORN. REPAIR PER EN-27- 51-21-028--21 AND EVA-71266. THE REPAIR IS APPROVED BY BAC, 8 100-9. THE REPAIR IS 12 MONTH LIMITED REPAIR, AND A NEW 8100-9 MUST BE ISSUED TO COMPLY WITH 1 4 CFR 25.571 AND 26.43 (D)SDR 2008UALA01400Skin · wornLEFT O/B FLAP, NEAR MID POINT, 30" FROM AFT END, SKIN IS WORN. REPAIR PER EN57-0 028-03 AND EVA-71266. THE REPAIR IS APPROVED BY BAC, 8100-9. THE REPAIR IS 12 MONTH LIMITED REPAIR, NEW 8100-9 MUST BE ISSUED TO COMPLY WITH 14 CFR25.571 AND 26.43(D). OK TO CF PSDR 2008UALA01374Support Fitting · wornNR 2 FLAP SUPPORT FITTING 2V JOINT OUTBOARD END BUSHING BORE IS WORN.SDR 2008UALA01373Support Fitting · wornNR 8 FLAP SUPPORT FITTING JOINT 8V, BOTH INBOARD AND OUTBOARD END BUSHING BORE HOLE IS WORN.
SDR 2008UALA01372Support Fitting · wornNR 1 FLAP SUPPORT FITTING, JOINT 1V INBOARD BUSHING BORE IS WORN.
SDR 2008UALA01369Spring · weakDOOR 3L SLIDE PACK LATCH LEVER SPRING IS WEAK, LATCH LEVER HAS NO OVERCENTER FORCE ENGAGEMENT.SDR 2008UALA01368Spring · weakNR 2L DOOR SLIDE LATCH HOOK SPRING IS WEAK AND LATCH LEVER HINGE IS WORN.SDR 2008UALA01299Support Fitting · wornNR 7 FLAP UNDER WING SUPPORT FITTING IS WORN ON OUTBD SIDE, IB END, NR 7V JOINT.SDR 2008UALA01298Bushing · wornNR 7 FLAP SUPPORT UNDERWING LINK, IB JOINT 7V BUSHING. WORN IS BEYOND LIMIT.SDR 2008UALA01055Retainer · wornWEAR WAS FOUND AT SEAL RETAINER OF NR 2 STRUT AFT FAIRING AT SAF STA 362, FAIRING OUTBOARD FRAME.SDR 2008UALA01054Frame · wornWEAR WAS FOUND AT FRAME OF NR 1 STRUT AFT FAIRING SAF STA 362 (OUTBOARD SIDE).
SDR 2008UALA01033Skin · dentedA DENT WAS FOUND ON EXTERNAL SURFACE OF DOOR 2L FWD LWR CORNER. SUSPECT EQUIPMENT DAMAGE DUE TO LOADING OR UNLOADING AC. CUT OUT DAMAGE AND ACP HFEC FOR CRACKED FREE INSP. FABRICATED AND INSTALLED DOUBLER WORK IS ACP ON AMECO GFS 21480 AT HMV3. ACFT OK FOR SSDR 2008UALA01023Skin · dentedA DENT WAS FOUND ON FUSELAGE SKIN AT STA 667, BETWEEN STR 26L AND 27L. DENT IS 4" X 5". CUT OUT DENT AND ACP HEFC INSP FOR DAMAGE FREE. ACP OPEN HOLE HFEC INSP FOR FASTENER HOLES. INSTALLED DOUBLER REPAIR. THE REPAIR IS CAT B REQUIRES FUTURE REINSPECTION AFSDR 2008UALA00341Light · brokenEMERGENCY LIGHTING STRIP BROKEN ON SEAT 2F. REPLACED LIGHT STRIP.SDR 2008UALA00262Power Supply · odorWHEN 6 CIRCUIT BREAKERS FOR EMERGENCY LIGHTS IN. ELECTRICAL ODOR C/B OUT NO ODOR. REPLACED EMERGENCY LIGHT POWER SUPPLY M33424 AND POWERED UP EMERGENCY LIGHTS. OPS TEST NOW OK, NO ODOR.SDR 2008UALA00176Acm · odorREPORT OF ODOR AND SLIGHT HAZE IN BUSINESS CLASS, ALSO NOTICED IN FLT DECK. ACCOMPLISHED TROUBLESHOOTING. REPLACED RECIRC FAN, BUT PROBLEM STILL EVIDENT. REPLACED LEFT SIDE AIR COND PACK AIR CYCLE MACHINE.SDR 2007UALA05103Light · inoperativeFOUND SEAT 3E AND SEAT 2F (1 OF 2) EMERGENCY PROX LIGHTS INOPERATIVE. REPLACED LIGHT ASSY.SDR 2007UALA04004Slide · misinstalledDOOR 2R ESCAPE SLIDE PACK IS FAULTY. 2R ESCAPE SLIDE PACK REPLACED. SLIDE APPEARED TO BE IMPROPERLY INSTALLED. AIRCRAFT OK SERVICE.
SDR 2007UALA04003Bracket · damagedDOOR 2R GIRT BAR PICK UP LINKAGE BRACKET DAMAGED. REMOVED FROM RT SIDE. REPLACED BRACKET AND REINSTALLED SLIDE. OK FOR SERVICESDR 2007UALA03742Engine · shutdownCREW REPORTED LEFT ENGINE AUTO SHUTDOWN, HIGH VIBRATION AND HIGH EGT.SDR 2007UALA03469Battery · reads lowAPU BATTERY NOT CHARGING.SDR 2007UALA03468Skin · delaminatedNR 9 SLAT OUTBOARD EDGE DELAM ON UPPER AND LOWER SURFACE.SDR 2007UALA03364Cover · misinstalledDOOR 4R AFT GIRT BAR DOESN'T SHOW ARMED. FOUND AFT GIRT BAR POSITION INDICATOR PLASTIC COVER IN UPSIDE DOWN POSITION. REINSTALLED COVER. GIRT BAR SHOWS ARMED.SDR 2007UALA03338Circuit Card · failedHYD PUMP DEM C1 MESSAGE. ACP FAILED GROUND TEST. REPLACED C1 LOGIC SPEED CONTROL CARD AND OPS TEST OK IAW AMM 29-11-15.SDR 2007UALA01894Lamp · missingFOUND SEAT 1E HAS AFT EMERGENCY LIGHT MISSING. [06-26-07] RELAMPED. TESTED GOOD.SDR 2007UALA00958Ground Stud · corrodedCEILING LIGHTS AT SEAT 3E & SEAT 9D ARE OUT. FOUND EMERGENCY AREA LIGHTS INOP AT SEVERAL SEATS. TROUBLESHOOTING REVEALED THAT GROUND BLOCK CORROSION IS INHIBITING STRUCTURAL GROUND. REPLACED GROUNDING STUD. EEL SYSTEM OP CHECKS OK.SDR 2006UALA02397Skin · damagedFUSELAGE SKIN STA 650 BELOW STR 34 RT IS DAMAGED. MAJOR REPAIR ACCOMPLISHED TO FUSE SKIN STA 650 BELOW STR 34 RT. DOUBLER REPAIR INSTALLED. OK FOR RETURN TO SERVICE. SUSPECT DAMAGED BY GROUND EQUIPMENT.SDR 2006UALA00044Bulb · burned outEXTERIOR EMERGENCY SLIDE LIGHT INOP AT DOORS 1R AND 2L.SDR 2005UALA01208Light · inoperativeSEAT 1E EMERGENCY PROX LIGHT INOP. REPLACED FOWARD EEL LIGHT AT 1E.SDR 2005UALA01144Housing · damagedLOSS OF LEFT BLEED AIR. MAINTENANCE FOUND A 5 INCH DIAMETER HOLE IN FAN INLET DIFFUSER HOUSING (FIDH) DUE TO BROKEN FLANGE ATTACHING THE FIDH TO THE HEAT EXCHANGER. REPLACE FAILED FIDHSDR 2005UALA00698Skin · delaminatedNR 11 SLAT OUTBD EDGE UPPER AND LOWER SURFACES DELAMINATED. REPAIRED AND NDT INSPECTED IAW 777 AMM 57-43-99-803. INITIAL INSP REQUIRED AT 50 CYCLES AND EVERY 500 CYCLES THEREAFTER UNTIL A PERMANENT REPAIR IS ACCOMPLISHED AT NEXT HMV. THIS LOCALIZED DELAM ISSDR 2005UALA00695Skin · delaminatedNR 9 SLAT OB EDGE DELAMINATED ON UPPER AND LOWER SURFACE. REPAIRED AND NDT INSPECTED IAW 777 AMM 57-43-99-803. INITIAL INSP REQUIRED AT 50 CYCLES AND EVERY 500 CYCLES THEREAFTER UNTIL A PERMANENT REPAIR IS ACCOMPLISHED AT NEXT HMV. THIS LOCALIZED DELAM IS S