N768UA
Service difficulty reports · 221
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N768UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N768UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2011111406222Module · faultyTAT STATUS MSG DISPLAYED WITH GROUND PROX WINDSHEAR AND EPR INDICATION FAILING. MSG 34-25800. ACCOMPLISHED TROUBLESHOOTING PER FIM 34-21 TASK 809, REPLACED TAT PROBE PER MM & INPUT-OUTPUT MODULE (IOM) PER MM. MESSAGES CLEARED AND SYSTEM OPERATES NORMAL.SDR UALA2011092605195Interface Unit · failedENTERTAINMENT SYSTEM AUDIO AND VIDEO INOPERATIVE. REPLACED VIDEO INTERFACE UNIT PER AMM. REACTIVATED ENTERTAINMENT SYSTEM LOADED VIU & CONFIG DATABASE. PAX AUDIO AND VIDEO ENTIRE CABIN NORMAL OPERATION AFTER CONFIG DATABASE INSTALL COMPLETE.SDR UALA2011091404981Module · faultyZMU ISSUES. RPL ZMU-2 FOR TROUBLESHOOTING IAW MM. OPS CHECKS NORMAL.SDR UALA2011091404980Module · faultyCACP TEST INDICATES BAD ZMU NR 3. REPLACED ZMU3 PER AMM.SDR UALA2011090904888Module · faultyLIGHTS IN BACK ZONE OF ECONOMY WON'T COME ON. REPLACED ZMU NR 3 PER MM.SDR UALA2011082204494Unknown · malfunctionedLEFT AIMS HAS A FAULT ON CPM-GG (M011) THAT WILL NOT UNLATCH. TRIED LOADING SOFTWARE NO HELP, SWAPPED WITH M10 IN SAME BACKPLANE & PROBLEM FOLLOWED, UNITS RETURNED TO ORIGINAL POSITION. REPLACED CPM-GG M11 IN LEFT AIMS CABINET PER MM, CHECKS OKAY.SDR UALA2011081804392Receptacle · damagedPRIMARY POWER RECEPTICAL DAMAGED. WIRE W4032-0001-20 (AL) CONDUCTOR IS DISCOLORED & HAS BROKEN STRANDS AT DP30A TERMINAL LUG. WIRE W4032-0002-20 (AL) IS DISCOLORED AT TERMINAL INSULATOR. REPLACED PRIMARY EXT POWER RECEPTACLE UP TO INSULATOR SUPPORT.SDR UALA2011081104226Control Panel · malfunctionedWXR SYS STATUS MSG DISPLAYED. MAT SHOWS WXR SYS CTRL PANEL HAS AN INTERNAL FAULT. WXR SYS TEST FAILED. DEFECT PLACED ON MEL 3443F FOR REPAIR. REPLACED CONTROL PANEL PER AMM.SDR UALA2011062002988Acm · malfunctionedRT PACK TRIP REPLACED RIGHT ACM, OPS CHECK NORMAL. ALSO REPLACED ASCPC, ALL NO HELP, PACK TRIPS IN 8 MIN OR LESS. REPLACED RIGHT PACK FLOW SENSING VENTURI PER MM.SDR UALA2011060302709Actuator · leakingDURING W-A NOTICED HEAVY HYD LEAK COMING FROM LT MAIN GEAR TILT ACTUATOR. REPLACED LT GEAR TILT ACTUATOR PER MM. LEAK CHECK OK. PART IS A LOAN UNIT.SDR UALA2011042902090Heat Exchanger · crackedRIGHT AIR COND HEAT EXCHANGER IS CRACKED. REPLACED HEAT EXCHANGER PER MM, OPS CHECKED GOOD.SDR UALA2011042101940Transceiver · out of toleranceFWD XCVR IS OUT OF TOLERANCE. TRANSCEIVER FOUND DEFECTIVE. REPLACED TRANSCEIVER. OPS ARE NORMAL.SDR UALA2011041401807Sensor · faultySTATUS MSG HEAT TAT. REPLACED TAT PROBE AND PROBE HEAT RELAY K30331, OPS CHECK GOOD.SDR UALA2011030901147Unknown · leakingFUEL LEAKING FROM NR 11 DRAIN TUBE NR 2 ENGINE (13 DROPS PER MINUTE). NR 2 ENGINE WAS IDLE, RAN FOR 5 MINUTES. INSPECTED DRAIN TUBE 30 MINUTES AFTER SHUT DOWN. NO DROPS NOTED.SDR UALA2011022400912Module · faultyCABIN AREA CONTROL PANEL AT DOOR 1L IS FAILING TO BOOT AT POWER UP. REPLACED AND TESTED CACP, PANEL OPS CHECKED GOOD.SDR UALA2011022400911Light · inoperativeSEAT MOUNTED EMERGENCY EXIT LIGHT AT SEAT 1F IS INOPERATIVE. REPLACED LIGHT ASSY, OPS CHECKS GOOD.SDR UALA2010110104045Terminal Block · corrodedFOUND GROUND BLOCK GB21351-AC COMING APART AND CORRODED. PART IS LOCATED BY SEAT 22 AB. STA 1357 REF WIRING DIAGRAM. PSU'S OPEN FOR ACCESS. CLEANED & TREATED MINOR SURFACE CORROSION UNDER GROUND BLOCK. NEW GROUND BLOCK RIVETED IN PLACE. NEEDS WIRES HOOKED UP ASDR UALA2010102904021Converter · faultedSTATUS MSG ELEC BACKUP SYS DISPLAYED IN FLT. FOUND MX MESSAGE 24-48801, OCCURRED AT ENGINE START AND IN CRUISE. REPLACED BACKUP GENERATOR CONVERTER.SDR UALA2010102103892Oil Cooler · leakingNR1 ENG OIL LOSS. ACP OIL SERVICE FOR NR1 ENG BETWEEN 0.5 AND 1.5 HOUR AFTER ENGINE SHUTDOWN (ON ARRIVAL). ONCE AMOUNT OF OIL ADDED IS DETERMINED NEED TO ACCOMPLISH OIL SVC ASAP. SERVICED NR1 ENG OIL. 15 QUARTS ADDED. REPLACED NR 1 ENG NR 4 BEARING COMPARTMENSDR UALA2010100703719Tab · crackedRUDDER TAB SKIN IS CRACKED ON THE LEADING EDGE LH SIDE APPROXIMATELY THREE INCHES FROM TOP. REMOVED RUDDER TAB. RUDDER PCU LOCK IS INSTALLED, RUDDER PCU CIRCUIT BREAKERS ON POWER SUPPLIES PULLED AND TAIL HYD POWER SWITCHES ARE IN SHUTOFF. REMOVED PANELS, HARSDR UALA2010092903609Guide Vane · crackedENG FAILED DUE TO NGV WITH BURN THROUGH IN THE OUTER PLATFORM RADIUS. HPT STG 1 NGV AFT OF THE IGNITORS. NGV HAS 2 EA CRACKS INTO THE PLATFORM RADIUS WITH BURN THROUGH IN THE RADIUS OF THE AFT CRACK. THERE IS A INTERSECTING CRACK (AXIALY) WITH BURN THROUGH. SDR UALA2010091403413Generator · faultyCREW REPORTS APU GENERATOR IS INOPERATIVE. REPLACED GENERATOR, OPS CHECKED NORMAL.SDR UALA2010091403424Lamp · inoperativeEMERGENCY LIGHT OUTSIDE OF DOOR 2L IS OUT. REPLACED LAMP.SDR UALA2010090703273Sensor · malfunctionedRT PACK EICAS MESSAGE AT GATE. REPLACED RT CTC & R COMPRESSOR TEMP SENSOR M21206 IAW MM. TESTS PASSED WITH NO FAULTS & MESSAGES CLEARED.SDR UALA2010062802303Valve · faultyPACK L 1) OVERHEAT AT LT PACK OUTLET OR LT PACK COMPRESSOR OUTLET OR LT PACK FLOW CONTROL VALVES (FCVS) ARE CLOSED DUE TO: FCVS FAILED CLOSED, FCVS LATCHED CLOSED BY CABIN TEMP CONTROLLER (CTC) BECAUSE OF FAULT, OVERHEAT, OR PACK FLOW SENSING FAILURE, OR BOTHSDR UALA2010051901683Controller · faultyPACK FCV L 1 (BUT NOT BOTH) OF THE 2 LT PACK FLOW CONTROL VALVES (FCV) ARE NOT IN THE COMMANDED POSITION. STATUS MSG-2124001 LATCHED ER MODE: DURING T-S OBSERVED LT LOWER FLOW CONTROL VALVE REMAINING FULLY OPEN EVEN SELECTING PACK OFF. LOCKED LWR FLOW CONTROLSDR UALA2010051901674Controller · malfunctionedLT OZONE CONVERTER INOP DUE TO LT PACK LWR FLOW CONTROL VALVE DEACTIVATED CLOSED. OZONE CONVERTER HAS BEEN DEFERRED IN COMPLIANCE WITH MEL CARD 21445. DF931 FOR LT PACK LOWER FCV CLEARED. REOPENED ON 18MAY10 FOR: LOWER FCV FAULT CAME BACK DF931. PERFORMED FAUSDR UALA2010051701659Slide · unwanted deployDOOR ESCAPE SLIDE AT DOOR 2R DEPLOYED INADVERTANTLY. REMOVED DOOR 2R SLIDE. REPLACED SLIDE WITH NEW (1) IAW AMM.SDR UALA2010041201226Socket · meltedBUSINESS CLASS GALLEY OVHD LIGHTING POSSIBLE OVERHEAT- SHUTOFF : FOUND BURNING SIGNS AT LIGHT ASSY ABOVE WARMING OVEN W32. BULB AND SOCKET MELTED. INSPECTED AREA, NO ABNORMALIES NOTED OUTSIDE OF LIGHT ASSY. DISCONNECTED ASSY AND TURNED ON CEILING LIGHTS, OPSDR UALA2010041201216Bulb · meltedBUSINESS CLASS GALLEY OVERHEAD LIGHTING POSSIBLE OVERHEAT-SHUTOFF. FOUND BURNING SIGNS AT LIGHT ASSY ABOVE WARMING OVEN W32. BULB AND SOCKET MELTED. INSPECTED AREA, NO ABNORMALITIES NOTED OUTSIDE OF LIGHT ASSY. DISCONNECTED ASSY AND TURN ON CEILING LIGHTS,SDR UALA2010031700889Light · inoperativeEEL LIGHT AT SEAT 39C IS INOPERATIVE. REPLACED LIGHT ASSY, CHECKS GOOD.SDR UALA2010031500858Valve · closedNO WATER IN FWD MID-LAVS, FLIGHT DIVERTED. UPON ARRIVAL ALL FC AND BC GALLEY AND SINK DRAINS FULL AND NOTHING DRAINING OUT OF DRAIN MAST. LT RMM FOUND CABLE ON GRAY WATER DRAIN RESTRICTOR VALVE UNATTACHED, ALLOWING VALVE TO REMAIN IN THE CLOSED POSITION. PESDR UALA2010010400054Connector · damagedPACK L OVERHEAT AT LT PACK OUTLET OR LT PACK COMPRESSOR OUTLET OR LT PACK FLOW CONTROL VALVES (FCV) ARE CLOSED DUE TO: FCVS FAILED CLOSED, FCVS LATCHED CLOSED BY CABIN TEMP CONTROLLER (CTC) BECAUSE OF FAULT, OVERHEAT, OR PACK CONTROL SWITCH COMMANDED OFF, OR NSDR UALA2009122403996Seal · leakingUPON ARRIVAL, FUEL WAS LEAKING FROM THE FWD SIDE OF PANEL 533BB (5TH PANEL OUT FROM WINGROOT) UNDER WING ACCESS PANEL. REPLACED SEAL AND MESH GASKET. LEAK ABATED.SDR UALA2009122303985Control Valve · malfunctionedPACK FCV L STATUS MSG. ON LT PACK TROUBLESHOOTING, BOTH PACK FCVS HAD DIFFERENT PROBLEM ON GROUND TEST. SWAPPING ONE BENEATH THE OTHER UPPER AND LOWER PACK FCV. NOW THE UPR FLOW CONTROL VALVE OPS & INDICATION NORMAL. TEST THROUGH CABIN CTLR PASSED. THE LOSDR UALA2009122303984Antenna · damagedUPON ARRIVAL FOUND RT VHF ANTENNA DAMAGE. ANTENNA FOUND DAMAGED. REPLACED RT VHF ANTENNA. OP CHKS GOOD.SDR UALA2009091402887Idg · malfunctionedLEFT ENGINE DRIVEN GENERATOR (IDG, GCB) INOPERATIVE AND ASSOCIATED IDG DISCONNECTED. CHECKED NR 1 IDG OIL LEVEL AND BACKUP GENERATOR OIL LEVEL AND FOUND FULL. REPLACED IDG.SDR UALA2009072702226Battery Pack · no testMED 1R HAS EPAS BATTERY THAT WON'T TEST. REPLACED EPAS BATTERY PACK. OP'S CHECKED GOOD.SDR UALA2009072702225Light · inoperativeSEATS 1E & 3E IN FIRST CLASS EMERGENCY FLOOR PROX LIGHTS INOP. REPLACED AFT EMERGENCY PROX LIGHT IN BOTH SEATS.SDR UALA2009062601807Wire · damagedFOUND DAMAGED WIRES AT APPROX STATION 1615 UNDER FLOOR PANELS. PICTURES HAVE BEEN POSTED ON RVI SITE. APPROX 3 DOZEN WIRES DAMAGED, OF THESE APPROX 2 DOZEN TWISTED RYB WIRES BURNT THRU, REMOVED TIES & LACING CORD, APP 5 FT ALONG W5081 BUNDLE, PNL, ALONG RT SSDR UALA2009061501705Lamp · inoperativeSEAT 2E EMERGENCY LIGHT FWD INOP. REPLACED LAMP ASSY, OPS CHECK NORMAL.SDR UALA2009061501704Lamp · inoperativeSEAT 1E EMERGENCY LIGHT OUT AFT. REPLACED LAMP ASSY, OPS CHECK NORMAL.SDR UALA2009061001648Battery · faultyAPU DID NOT START, APU STATUS MSG, APU CHARGER MSG ALSO. RESET APU BATTERY CHARGER CB ON P320. APU BATT NOT CHARGING. SUSPECT CHARGER AT FAULT. REPLACED BATTERY AND CHARGER, ALL TESTED OKAY.SDR UALA2009051101320Light · missingAFT EEL LIGHT MISSING AT SEAT 1E. REPLACED AFT EEL LIGHT, OP CHECKS GOOD.SDR UALA2009032700895Light · inoperativeEMERGENCY EXIT LIGHT ON SEAT 3E, AFT LIGHT IS INOP. RPL LAMP ASSY, OPS CHECK OKAY.SDR UALA2009031000750Idg · failedR IDG FAILURE. RTFL.SDR UALA2009031000702Starter · wornAPU CONTROL APUC DETECTED FAILURE OF REDUNDANT CONTROL FUNCTION OR LOSS OF ONE ARINC 629 CHANNEL. STATUS MSG01- NOT ACTIVE ENGINE START HARD; ELECTRIC STARTER MOTOR HAS BRUSH WEAR. DB- APU CONTROLLER (APUC) MSG-4910760 INACTV ES HARD. REPLACED STARTER MOTOSDR UALA2009030300702Starter · faultyAPU CONTROL APUC DETECTED FAILURE OF REDUNDANT CONTROL FUNCTION OR LOSS OF ONE ARINC 629 CHANNEL. STATUS MSG01- NOT ACTIVE ENGINE START HARD; ELECTRIC STARTER MOTOR HAS BRUSH WEAR. DB- APU CONTROLLER (APUC) MSG-4910760 INACTV ES HARD. REPLACED STARTER MOTORSDR UALA2009031000611Duct · faultyAPU HAD MULTIPLE SHUTDOWNS. REPLACED FLEXIBLE SURGE DUCT, APU OPS CHECK GOOD. FOUND TO INSULATION BLANKET BAD, ALSO UNDER AFT MOUNT. NEED TO PULL APU TO REPLACE. OPS 1. DROP APU REPLACED TOP AND SIDE INSUL BLANKETS 107441 PCN 295-1005, 295-6040 AND REINSTASDR UALA2009022300611Sensor · faultyAPU HAD MULTIPLE SHUTDOWNS. TOTAL PRESSURE APU PNEUMATIC CLUSTER SENSOR.