N785UA
Service difficulty reports · 189
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N785UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N785UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2009112303635Light · inoperativeEEL LIGHT INOP SEAT 2E AFT. REPLACED LIGHT ASSY, OPS CHECKS GOOD.SDR UALA2009091102868Controller · faultyANTI-ICE ENG R EICAS MSG. REPLACED RT ENG ANTI-ICE VALVE. RAN ENG, NO HELP. NEEDS MORE TIME FOR T/S. REMOVED AND SAFETY CONTROLLER ELECTRICAL PLUG AND VALVE LOCKED IN OPEN. CONFIRMED BAD CONTROLLER BY SWAPPING WITH LT ENGINE. REPLACED RT ENGINE ANTI ICE SDR UALA2009061901738Light · inoperativeEMERGENCY LIGHT AT SEAT 3FE INOP. REPAIRED EMERGENCY LIGHT AT SEAT 3FE. GROUND TEST OK.SDR UALA2009060501617Gcu · inoperativeELEC GEN SYS L STATUS MESSAGE. FOLLOWED BY GALLEY LOAD SHED INDICATIONS. BUS TIE SWITCH DID NOT INDICATE ISOLATED HOWEVER NO CONNECTION ON SYNOPTIC PAGE TO BUS TIE. APU GEN & BUG ALSO DID NOT INDICATE IT WAS POWERING THE L BUS. CREW CYCLED L GEN SWITCH TO SDR 2008UALA06296Battery · faultyAPU BATTERY AND APU CHARGER STATUS MESSAGE. REPLACED APU BATTERY & CHARGER. OP CHECKS NORMAL.SDR 2008UALA06000Connector · inoperativeFWD EMERGENCY LIGHT AT SEAT 3F INOP. SECURED CONNECTOR. OP CHECKS OKAY.SDR 2008UALA05999Connector · inoperativeAFT EMERGENCY LIGHT AT SEAT 1E INOP. SECURED CONNECTOR. OP CHECKS OKAY.SDR 2008UALA05998Light · inoperativeAFT EMERGENCY LIGHT AT SEAT 2E INOP. RELAMPED EMERGENCY LIGHT, TESTED GOOD.SDR UALA2008111305786Probe · faultyRECEIVED UNBALANCED FUEL EICAS TWICE WITH FAULTY R FUEL QUANTITY. REPLACED LEFT CTR TANK PROBE NR 2.SDR 2008UALA05786Indication Sys · malfunctionedGOT UNBALANCED FUEL EICAS TWICE WITH FAULTY R FUEL QUANTITY.SDR 2008UALA03287Unknown · odorBURNING ODOR IN BC GALLEY WHEN ALL COFFEEMAKERS ON. CHECKED COFFEEMAKERS, HOT PLATES, OVENS, CEILING LIGHTS, GALLEY LIGHTS AND A CHILLER ALL OK. NO BURNING SMELL ON ARRIVAL. COULD NOT DUPLICATE PROBLEM. AC OK FOR SERVICE.SDR 2008UALA03064Controller · shortedTHE "AIR SPLY L HTR" C-B ON P110 POS M16 WILL NOT RESET. SUSPECT HIGH PRESSURE CONTROLLER/FAN AIR SHORTED. REPLACED LT FAN HP CONTROLLER. RAN BOTH ENGINES. OPS OK. AC OK FOR SERVICE.SDR 2008UALA02981Controller · faultyLEFT ENGINE BLEED INOP IN FLIGHT. SUSPECT FAULTY HIGH PRESSURE FAN AIR CONTROLLER. REPLACED LT HPFAC RAN BOTH ENGINES. OP CHECKED GOOD. AC OK FOR SERVICE.SDR 2008UALA01492Unknown · odorLIGHT CHEMICAL-PLASTIC SMELL IN AFT GALLEY. COULD NOT LOCATE SOURCE.SDR 2008UALA01394Slide · unwanted deployDOOR 3R SLIDE DISCHARGED. SLIDE DEPLOYED ACCIDENTALLY. REPLACED DOOR SLIDE PER AMM 25-66-00 P.201, 25-66-01 P.401, REPLACED 'EPAS' RESERVOIR PER AMM 52-11-22 P.401. AC OK FOR SERVICE.SDR 2007UALA03780Starter · malfunctionedAPU START SYSTEM APUC DETECTED FAILURE IN THE ELECTRIC STARTER, FUEL SCHEDULING, IGNITION, OR LUBE DEPRIME SYSTEMS OR NO SIGNAL FROM ELMS TO THE APUC. 10-16-07 REPLACED APU IGNITOR PLUG NR 1 PER MM49-41-02, AND IGNITION LEAD NR 1 PER MM49-41-04. APU BITSDR 2007UALA03047Connector · unsecureFIRST CLASS SEATS 1E, 1F, 2E AND 2F FWD AND AFT EMERGENCY LIGHT ASSEMBLIES ARE INOPERATIVE. 08-31-07 SECURED POWER JUMPER PLUGS AT SEAT 2E. EEL LIGHT ASSY TESTED OK FOR SERVICE.SDR 2007UALA03046Sensor · leakingFOUND OIL LEAKING FROM COVER PLATE ABOVE OIL PRESSURE SENSOR AT APU LUBE CLUSTER, ALSO FOUND OIL LEAKING FROM GENERATOR FEEDER CABLES. FOUND GENERATOR SOAKED WITH OIL AND GENERATOR FEEDER CABLES ARCING AND BURNED. APU WAS FOUND LOW ON OIL. 08-31-07 REPLACSDR 2006UALA00555Hinge Fitting · lightning strikeLIGHTNING STRIKE WAS FOUND ON TOP RUDDER HINGE FITTING IN VERTICAL STAB. THE FITTING WAS DAMAGED BY LIGHTNING STRIKE AND IT WAS REPLACED.SDR 2005UALA01124Smoke · detectedELECTRICAL ODOR (HEAT) APPARENT AROUND DOOR 2R. OPENED CLOSET AT 2R AND SMOKE WAS SEEN TO EXIT. GALLEY POWER TURNED OFF AND ODOR DISSIPATED. REPLACED TRANSFORMER 10/11/05. SYSTEM HAS BEEN FUNCTIONING NORMALLY AS OF 11/10/05. PROBLEM APPEARS TO HAVE BEEN A OSDR 2004UALA00580Wedge · delaminatedLWR SURFACE OF TRAILING EDGE WEDGE DELAMINATED. MAJOR REPAIR ACCOMPLISHED. REPAIRED TRAILING EDGE WEDGE.SDR 2004UALA00579Wedge · delaminatedTRAILING EDGE WEDGE DELAMINATED AT LWR INBOARD END FROM RUBBING ON LEADING EDGE WING SKIN. MAJOR REPAIR ACCOMPLISHED. REPAIRED WEDGE.SDR 2004UALA00302Potable Water · failedPOTABLE WATER IS NOT WORKING AND LAVS STARTING TO BACK UP. ONE HOUR OUT OF LHR WATER PRESSURE WENT TO NO PRESSURE. FOUND AIR COMPRESSOR HAD FAILED. WITH ENGINES/APU RUNNING, BLEED AIR SHOULD HAVE BEEN THE ONE PRESSURIZING THE SYSTEM. THE APU BLEED AIR CHESDR 2003UALA00928Light · inoperativeEMERGENCY LIGHT INOPERATIVE AT SEAT 2F AFT POSITION. REPLACED LIGHT ASSY.SDR 2003UALA00336Skin · crackedNR 1 SLAT, OTBD LOWER L/E SKIN CRACKED. MAJOR REPAIR ACCOMPLISHED. CRACK REPAIRED W/EXTERNAL DOUBLER.SDR 2002UALA01699Cooling Fan · failedEQUIPMENT COOLING EICAS MESSAGE "EQP CLNG OVRID". EQUIPMENT COOLING MESSAGES HIT ON PREVIOUS FLIGHTS. PROBLEM WAS FIXED BY REPLACING THE RT EQUIPMENT COOLING SUPPLY FAN. SHOP REPORTS THAT THE FAN FAILED DUE TO DEFECTIVE BEARINGS.SDR 2002UALA00502Bellcrank · fracturedBELL CRANK FOUND FRACTURED ALONG WITH ADJACENT 113W1452-X PUSH ROD WITH ROD END FRACTURED. FOUND DAMAGED OVERWING FAIRING SPRT MLG BODY DOOR STOP STRUCTURE INSTL (49W4172-2,149W4175-1). MINOR DAMAGE (GOUGE TO INSIDE WALL OF I/B FLAP TRACK ON I/B FLAP). CLIPSDR 2001UALA02477Light · inoperativeEMERGENCY PROX LIGHT AT SEAT 42D IS INOP. BULB IN FLOOR PROXIMITY LIGHT ASSY FAILED. REPLACED FLOOR PROXIMITY LIGHT ASSY.SDR 2001UALA01789Light · damagedSEAT 1E AFTER EMERGENCY LIGHT DOES NOT WORK. FORWARD EMERGENCY LIGHT WORKS OK. LIGHT ASSEMBLY FOUND DAMAGED. REPLACED LIGHT ASSEMBLY. OPS CHECKED GOOD.SDR 2001UALA00512Floorbeam · crackedSTA 246 MID-CHORD HORIZ LEG CRACKED AT RBL 38.5. *S/D* REPAIRED PER SRM 53-10-51, REPAIR 2.SDR 2001UALA00049Display · failedSMOKE REPORTED AT 4R CACP ON TAXI OUT. AIRCRAFT RETURNED TO GATE. *S/D* BOTH BACKLIGHTS ON THE SCREEN FAILED CAUSING AN OVERHEAT CONDITION AT THE INSULATION OF THE BACKLIGHTS. THE TOUCHSCREEN WAS REPLACED. NO EVIDENCE OF ACFT ELECTRICAL PROBLEMS WERE NOTESDR 2000UALA00568Indicator · malfunctionedDURING CLIMBOUT-PASSING 15,000-BOTH ALTIMETER INDICATIONS ON THE PFD''S TURNED AMBER IN COLOR AND SURROUNDED BY AMBER BOX. DIVERTED IAD. *S/D* PER 777 FLIGHT MANUAL PAGE 19-63 FOR THE INFORMATION ABOUT THE BAROMETRIC SETTING THE FOLLOWING IS QUOTED THE DISSDR 2000UALA00566Idg · failedLT IDG DISCONNECTED ON T-O ROLL. DUMPED FUEL. RETURNED TO FIELD. *S/D* EICAS ELEC GEN SYS L WAS DISPLAYED WITH ASSOCIATED MAINTENANCE MESSAGES 24-30031 (GENERATOR CONTROL UNIT (L) HAS AN INTERNAL FAULT) AND 24-31611 (INTEGRATED DRIVE GENERATOR (L) EXCITER SDR 2000UALA00369Slide · leakingDURING SHOP OVERHAUL DOOR 4 RT SLIDE/RAFT ASSEMBLY (P/N: 62774-402, S/N: 0222) FAILED AIR RETENTION TEST. THE INFLATABLE ASSEMBLY (62424-402) TOP TUBE ASPIRATOR FLAPPER VALVE AND ASPIRATOR FLANGE WERE FOUND LEAKING (ASPIRATOR P/N: 62510-101). UNIT RETURNED TSDR 2000UALA00242Light · missingEMERGENCY LIGHT (FLOOR PROX) AT 2F MISSING. REPLACED LIGHT ASSEMBLY AT 2F, OPERATIONAL CHECK NORMAL.SDR 2000UALA00051Wire · chafedWHILE TROUBLESHOOTING INOPERATIVE FLUORESCENT LIGHT AT DOOR ONE LEFT, FOUND WIRE BUNDLE (W3251) ABOVE DOOR ONE LEFT WITH CHAFED AND BROKEN WIRES AND EVIDENCE OF OVERHEAT. *S/D* REPORTED THAT CONNECTOR BRACKET CRUSHED WIRE BUNDLE AGAINST FRAME OF FUSELAGE. SDR 99UAL900506Ballast · failedCREW REPORTS A BAD SMELL BY ROWS 42HJ AND 43CDE. SMELLS ELECTRICAL IN AREA OF CEILING PANELS. *S/D* INDIRECT CEILING LIGHT BALLAST AT ROW 43HJ FAILED. ASSEMBLY WAS REPLACED AND SYSTEM OPERATES NORMALLY.SDR 99UAL900451Compressor · stalledSHORTLY AFTER DEPARTURE IAD ENROUTE TO FRA, LEFT ENGINE INDICATED HIGH EGT ACCOMPLANIED BY ENGINE SURGE. ACCOMPLISH ENGINE SHUTDOWN AND RETURNED TO IAD. SUPPLEMENTAL DATA UPDATE COMPRESSOR STALL WAS CAUSED BY COMPRESSOR VARIABLE VANE SYSTEM FAILSAFED TO FULL SDR 98UAL900411Anti-Ice Valve · out of positionEN ROUTE, CREW GOT INDICATION OF LEFT ENGINE ANTI-ICE VALVE IN CLOSE POSITION. AIRCRAFT DIVERTED TO ORD.