N795UA
Service difficulty reports · 206
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N795UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N795UA' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2010020200425Pcu · leakingFOUND LEAK AT NR 4 SPOILER ACTUATOR. LEAK IS ONE DROP PER MINUTE OR LESS DURING ACTUATION. REQUIRES ACTUATOR. PART PLACED IN LOB. HYD SYS SERVICED. LEAK IS FROM STATIC SEAL AT BOTTOM OF ACTUATOR AND IS WITHIN CF LIMITS. REMOVED NR 4 SPOILER PCU. INSTALSDR UALA2010011300169Battery · faultyCREW REPORTS MAIN BATTERY AND MAIN BATTERY CHARGER EICAS MESSAGE ON TAXI OUT. BATT VOLTS 26VDC, 0 TO 1 AMP CHARGE INDICATED ON MX PAGE. NEED TO ACP TEST OF MAIN BATTERY & MAIN BATTERY CHARGER SYS BEFORE DEPARTURE. REPLACED BATTERY & MAIN BATTERY CHARGER. ALLSDR UALA2009082102584Gcu · failedELEC GEN OFF R-RESET ONE TIME DID NOT RESET. REPLACED R-GCU, MAT TEST PASSED, SCVD R-IDG, ENG RUN NORMAL, R-GEN CAME ON, NO FAULTS.SDR UALA2009072902282Accelerometer · inoperativeENG VIB MONITOR R RIGHT ENGINE AIRBORNE VIBRATION MONITORING (AVM) SYSTEM IS INOPERATIVE, OR LOSS OF TACHOMETER DATA. STATUS MSG-7706042 INACTV ER INTER -MAT MSG. 77-06042 INTERMIT. IN CRUISE. -INF- :MSG 77-06042 E-FLANGE ACCELEROMETER FAULT HIT AT HIGH INSDR UALA2009071602103Control Valve · malfunctionedPACK FCV R ONE (BUT NOT BOTH) OF THE TWO RIGHT PACK FLOW CONTROL VALVES (FCV) ARE NOT IN THE COMMANDED POSITION. R-PACK LWR FCV LOCKED CLOSED PER MEL. R-PACK LWR FCV REPLACED ALREADY. SUSPECT RIGHT PACK FLOW. REPLACED FLOW SENSOR. OPS CHECK CUTOUT FOUND SSDR UALA2009042701195Anti-Ice Valve · faultyRIGHT ENGINE ANTI-ICE VALVE INOP. FLIGHT DIVERTED. REPLACED ANTI-ICE VALVE CONTROLLER & RT ENG ANTI-ICE VLV.SDR UALA2009012600266Reservoir · faultyFOUND DOOR 3R EPAS RESERVOIR SQUIB PIN REMOVED RESERVOIR. INSTALLED SERVICEABLE 3R EPAS RESERVOIR.SDR UALA2009012200237Cable · stiffDOOR 3R ARM-DISARM STIFF. ACP CABLE REPLACEMENT. INSP ACCOMPLISHED. ACTUATION FORCE NORMAL. WORKED WITH DOOR LINER REMOVE AND REPLACE.SDR UALA2009012200248Cable · stiffDOOR 3L ARM-DISARM STIFF. DOOR 3L ARM-DISARM CABLE REPLACED.SDR UALA2008123007047Pressure Switch · faultyLT ENG FUEL FILTER INDICATION. REPLACED DIFFERENTIAL PRESSURE SWITCHSDR UALA2008120906794Cable · faultyDOOR 3R WOULD NOT DISARM ON ARRIVAL. DOOR DISARMED AND ARMED NORMALLY AFTER 10 MINUTES. DOOR HAS HISTORY AND WAS LIBERALLY COATED IN ICE RELEASE AND DOOR HEATER TEST NORMAL.SDR UALA2008120906793Cable · faultyDOOR 3L WOULD NOT DISARM ON ARRIVAL. DOOR DISARMED & ARMED NORMALLY AFTER 10 MINUTES. DOOR HAS HISTORY & AREA WAS LIBERALLY COATED IN INC RELEASE & DOOR HEATER TEST NORMAL.SDR UALA2008120506764Mechanism · lack of lubeTHE 3R IS ARMED AND FROZEN, PACK COVER REMOVED AND PINNED. CLEANED AND LUBED GIRT BAR MECHANISM SYSTEM CHECKS OK. PINS REMOVED AND STOWED IN POUCH; ACFT RETURNED TO NORMAL.SDR UALA2008120106700Light · brokenEXIT PATH LIGHT NOT SECURE. LIGHT HANGS BY WIRE. AFT EEL LIGHT AT SEAT 1F IS BROKEN AND REMOVED. REPLACED LIGHT EMERGENCY EVACUATION. CHECKED OK.SDR UALA2008112006575Light · inoperativeSEAT 2E REAR EEL LIGHT STRIP INOP.SDR 2008UALA06338Lamp · looseEMERGENCY EVAC LIGHT ON SEAT 1E DANGLING LOOSE. REPLACED LAMP, OPS NORMAL.SDR 2008UALA05612Light · inoperativeSEAT 2E EMERGENCY LIGHT INOP WHEN TESTED. FOUND LIGHTS INOP. REPLACED BOTH EMERGENCY LIGHTS AT SEAT 2E. BOTH OP CHECK GOOD.
SDR 2008UALA02496Filter · blockedRIGHT BACKUP GENERATOR FILTER BLOCKED UPON ARRIVAL. REPLACED RT BACK UP GENERATOR PER MM 24-25-01 OP AND LEAK CHECK GOOD. AC OK FOR SERVICE.SDR UALA2008111302332Fire Loop · faultyFIRE LOOP 2 ENG R RIGHT ENGINE FIRE DETECTION SYSTEM LOOP 2 FAILURE. STATUS MSG01- ACTIVE CLIMB INTERMITTENT; FIRE LOOP 2 (RIGHT ENGINE) IS SHORTED. DB- ENGINE FIRE DETECTION CARD (RIGHT) MSG02- ACTIVE CLIMB HARD; ENGINE FIRE DETECTION CARD (RIGHT) HAS AN ISDR 2008UALA02332Fire Detector · faultyFIRE LOOP 2 ENG R RIGHT ENGINE FIRE DETECTION SYSTEM LOOP 2 FAILURE. STATUS MSG01, ACTIVE CLIMB INTERMITTENT; FIRE LOOP 2 (RIGHT ENGINE) IS SHORTED. DB- ENGINE FIRE DETECTION CARD (RIGHT) MSG02, ACTIVE CLIMB HARD. ENGINE FIRE DETECTION CARD (RIGHT) HAS AN SDR 2008UALA01892Light · inoperativeEMERGENCY ESCAPE PATH LIGHT (AFT) IS INOP AT SEAT 3F. REPLACED LIGHT. OP CHKS GOOD.SDR 2008UALA01891Connector · looseEMERGENCY ESCAPE PATH LIGHT (BOTH) AT SEAT 1E ARE INOP. FOUND LOOSE CONNECTION UNDER SEAT. SECURED CONNECTION. AC OK FOR SERVICE.SDR 2008UALA00028Generator · malfunctionedELEC BACKUP GEN R RIGHT BACKUP GENERATOR OFF DUE TO A PROTECTIVE TRIP. SUSPECT SHAFT SHEARED. REPLACED LT BACK UP GENERATOR. OPS CHECKS GOOD. AC OK FOR SERVICE.SDR 2008UALA0028Unknown · unknownELEC BACKUP GEN R RIGHT BACKUP GENERATOR OFF DUE TO A PROTECTIVE TRIP.SDR 2007UALA05039Battery · faultyFOUND EMERGENCY FLASH LIGHT USED AT DOOR 3R. REPLACED BATTERY.SDR 2007UALA04824Engine · making metalUNABLE TO START NR 2 ENGINE. FOUND METEL ON NR 2 ENG MAIN GEARBOX CHIP DETECTOR. SUSPECT BEARING FAILURE. REPLACED NR 2 ENG. AC OK FOR SERVICE.SDR 2007UALA04711Wedge · damagedRIGHT MID FLAP TRAILING EDGE WEDGE IS CRUSHED AND CUT THROUGH. SUSPECTED TRAILING EDGE DAMAGED DURING GROUND MAINTENANCE. CATEGORY A REPAIR OF ACCOMPLISHED. NO FUTURE INSPECTION REQUIRED. AC OK FOR SERVICE.
SDR 2007UALA04710Skin · damagedNR 12 L/E SLAT LOWER SKIN NEAR MID HAS 6 INCH LONG CREASE. CUT OUT DAMAGE ON EXT SKIN AND INTERIOR NOSE BEAM, FABRICATED FILLER AND DOUBLER. INSTALLED REPAIR. AC OK FOR SERVICESDR 2007UALA04513Skin · nickedNICK WAS FOUND ON OUTER SKIN OF LWR FUSELAGE CENTER LINE, STA 529, STR 46R. INSTALLED DOUBLER REPAIR OF SKIN DAMAGE. OK FOR SERVICE.
SDR 2007UALA04512Skin · dentedDENT ON STA 277 ABOVE STR 28 LT. NDT, NO CRACKS OUT OF LIMITS. ACCOMPLISHED CAT B. REPAIR . REQ FUTURE REINSPECTION. NEW CF WILL BE CREATED. PERMANENT REPAIR WITHIN 16,000 FC OR NEXT HMV. AC OK FOR SERVICE.
SDR 2007UALA03957Circuit Card · faultyAPU FIRE CARD MESSAGE DISPLAYED. 10-23-07 REPLACED CARDS A9 & A12. MESSAGE CLEARED. AIRCRAFT RETURNED TO SERVICE.SDR 2007UALA03677Light · inoperativeSEAT 36C EEL LIGHT IS INOP. 10-05-07 REPLACED LIGHT. CHECKS GOOD.SDR 2007UALA03676Light · missingSEATS 1E & 1F EACH HAVE ONE EEL LIGHT MISSING. 10-05-07 REPLACED LIGHT IN EACH SEAT POSITION. CHECKS GOOD.SDR 2007UALA03084Brake Assy · malfunctionedLANDED UNDER AMBER ALERT DUE TO HYDRAULIC QUANTITY INDICATION. 08-31-07 AFTER TROUBLESHOOTING, THERE WAS EVIDENCE OF LEAKING & BRAKE CONTAMINATION W/ HYD FLUID, REPLACED NR 2 CENTER BRAKE ASSY, INCLUDING SUSPECTED LEAK SOURCE, THE HYDRAULIC COUPLING TO BRSDR 2007UALA02169Extinguisher · unserviceableWATER EXTINGUISHER-DOOR 1R MISSING SAFETY WIRE. [07-20-07] REPLACED EXTINGUISHER WITH SERVICABLE ONE. AIRCRAFT OK FOR RETURN TO SERVICE.SUSPECT SAFETY WIRE SNAGGED BY PASSENGER SERVICE EQUIPMENT AND BROKEN OFF.SDR 2007UALA00652Light · missingSEAT 3E AISLE SIDE MOVABLE ARM REST AFT EEL LIGHT IS MISSING. *S/D* REPLACED EEL LIGHT. OP CHECKS OK.SDR 2007UALA00596Warning System · activatedSTATUS MSG -APU-, BUT APU NEVER SHUT DOWN. REBOOTED ACFT, BUT NO HELP. AFTER TROUBLESHOOTING, DETERMINED THAT APU FIRE-OVERHEAT DETECTOR CARD WAS FAULTY. REPLACED CARD & APU OPERATED OK FOR SERVICE. SUSPECT DISTURBED CIRCUIT PATH ON CARD.SDR 2007UALA00180Light · inoperativeDOOR 1L EXTERIOR EMERGENCY SLIDE LIGHT INOPERATIVE. RELAMPED EXT EMERGENCY LIGHT AT DOOR 1L, OP CHECKS GOOD.SDR 2006UALA01774Light · looseFOUND EMERGENCY PATH LIGHTS 2E-1E LOOSE.SDR 2006UALA01762Light · looseFOUND EMERGENCY PATH LIGHTS AT 2E-1E LOOSE. FOUND AFT PATHLIGHT MISSING AT 1E. OTHERS OK. REPLACED MISSING LIGHT ELEMENT. OP CHECKS OK.SDR 2006UALA01692O-Ring · leakingLOW BOTTLE PRESSURE. ANALYSIS BY OEM DETERMINED BOTTLE FILL-VALVE O-RING WAS LEAKING. REPLACED FILL VALVE O-RING.SDR 2006UALA01605Slide · lowDOOR 1R SLIDE PRESSURE NOT IN GREEN ARC. REPLACED 1R DOOR SLIDE. SLIDE PRESSURE SHOWS IN GREEN AREA.SDR 2006UALA00103Fairing · damagedNR 1 ENGINE PYLON AFT FAIRINGS HAVE SUSTAINED HEAT DAMAGE TO LWR WEBS, STIFFENERS, CHORDS AND LWR PORTION OF THE FRAMES. NR 1 ENGINE PYLON AFT FAIRINGS HAVE SUSTAINED HEAT DAMAGE TO LWR WEBS, STIFFNERS, CORDS AND LWR PORTION OF THE FRAMES. INTERIM REPAIR WSDR 2004UALA00840Engine · failedLOSS OF OIL PRESSURE IN NR 2 ENGINE AND ENGINE VIBRATION. MAINTENANCE FOUND METAL ON THE MASTER & NR 4 BEARING CHIP DETECTORS, & METAL IN THE TAILPIPE. THE ENGINE WAS REPLACED IN SEA. TEARDOWN REVEALED THE THRUST BALANCE CAVITY ROTATING OUTER SEAL CAUGHT FISDR 2004UALA00747Light · inoperative3L CEILING EMERGENCY LIGHT INOPERATIVE. REPLACED LAMP.SDR 2003UALA00826Acm · seizedRT AIR CYCLE MACHINE CMC MESSAGE AND SMOKE ODOR REPORTED IN CABIN. SMOKE & ODOR REPORT IN THE CABIN WAS DUE TO HAZE & ODOR OF HOT METAL RELEASED BY SEIZED RT ACM. SUSPECT RT ACM FAILURE WAS DUE TO CLOGGED RT COND/REHEATER. RT ACM & RT COND/REHEATER WERE REPLSDR 2003UALA00655Doubler · damagedDOUBLER DAMAGE AT BS 660 STRINGER 25 L. MAJOR REPAIR ACCOMPLISHED. DOUBLER WAS REPAIRED.SDR 2001UALA01833Floorbeam · crackedSTATION 246 FLOOR BEAM MID-CHORD CRACKED AT LBL 38.5 NOTED CRACKING OF THE 141W8519-1 MID CHORD IS DUE TO THERMAL CONTRACTION THAT RESULTS IN HIGHER THAN EXPECTED IN-SERVICE LOADING OF THE DOUBLE DEPTH STATION 246 FLOOR BEAM. PART IS BEING REPAIRED.SDR 2001UALA00005Wire · damagedTWO ADJACENT EEL LIGHTS ON SEAT 1E INOP. REPLACED SEAT CABLE. CHECKS GOOD.SDR 2000UALA00784Light · inoperativeSEAT 3E AFT EEL LIGHT WILL NOT LIGHT. REPLACED LIGHT ASSY. OPS OK.