N8733M
Service difficulty reports · 30
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N8733M' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N8733M' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA2026092100094Fairing · cracked#1 ENGINE PYLON AFT FAIRING PLUME SUPPRESSOR CRACK DAMAGE REF TTG8Q01E23UB #1 ENGINE PYLON AFT FAIRING PLUME SUPPRESSOR CRACK DAMAGE FOUND END OF CRACK TO BE 1.400 FROM CENTERLINE OF CLOSEST RIVET ROW. REPAIRED PER SRM 54-50-70-2R-7 WITH ALLOWABLE DEVIATION PESDR SWAA2026090180716Fairing · crackedNR 1 ENGINE AFT FAIRING HEAT SHIELD PLUME SUPPRESSOR HAS A FIVE INCH CRACK 28 INCHES FORWARD OF AFT TIP. PERFORMED TIME LIMITED REPAIR IAW EA 26-154-02358. AIRCRAFT OKAY FOR CONTINUED SERVICE.SDR SWAA2025101624375Flashlight · inoperativeAFT INBD FLASHLIGHT INOPERATIVE. PERFORMED OPERATIONAL CHECK OF FLASHLIGHT PER AMM 25-64-00. OPS CHECK OK.SDR SWAA2024122780275Battery · inoperativeEMERGENCY EXIT BATTERY AT M1671 STA 727 +13 WL 212 RBL 68 WILL NOT CHARGE.<[01] OPENED AIR GRILL PANEL AT ROW 21 FED IAW AMM 33-51-06-960-802 STEP 4.D(3)(B).<BR><BR>REMOVED; REPLACED AND ACCOMPLISHED OPS CHECK FOR EMERGENCY BATTERY AT M1671 IAW AMM 33-51-06-96SDR SWAA2024122780276Battery · inoperativeEMERGENCY EXIT BATTERY AT M1676 STA 500C +7 WL 213 RBL 67 WILL NOT CHARGE.<[01] OPENED AIR GRILL PANEL AT ROW 8 FED IAW AMM 33-51-06-960-802 STEP 4.D(3)(B).<BR><BR>REMOVED; REPLACED AND ACCOMPLISHED OPS CHECK FOR EMERGENCY BATTERY AT M1676 IAW AMM 33-51-06-960SDR SWAA2024122780274Battery · inoperativeEMERGENCY EXIT BATTERY AT M2335 STA 500C +7 WL 213 LBL 67 WILL NOT CHARGE.<[01] OPENED AIR GRILL PANEL AT ROW 8 CBA IAW AMM 33-51-06-960-802 STEP 4.D(3)(B).<BR><BR>REMOVED; REPLACED AND ACCOMPLISHED OPS CHECK FOR EMERGENCY BATTERY AT M2335 IAW AMM 33-51-06-960SDR SWAA2024122777454Lens · missingFWD HORSESHOE PANEL CEILING EMERGENCY LIGHT LENS COVER IS MISSING<[01] INSTALLED FWD HORSESHOE PANEL CEILING EMERGENCY LIGHT LENS COVER IAW AMM-33-51-03-960-802<BR>A TAG #A79453;[02] VERIFIED ITEM 1<BR><BR>AUDIT C/WSDR SWAA2024122673290Bracket · cracked(DOT1447-12) AFT CARGO L/H BULKHEAD SUPPORT BRACKET AT STA 867 LBL15 WL157 HAS EVIDENCE OF CRACK<[01] 01 - REMOVED AND REPLACED L/H BULKHEAD SUPPORT BRACKET AT STA 867; LBL 15 AND WL157 PER [SRM 51-40-02-0G-0-D00069 (GENERAL - FASTENER INSTALLATION AND REMOVALSDR SWAA2024122773135Channel · corroded(151-#002) CORROSION ON U CHANNEL COMMON TO FLOOR SUPPORT AT B.S 747 TO 767; RBL 22; WL 158.<[01] 01 - REMOVED AND REPLACED 'U' CHANNEL (INTERCOSTAL) IN AFT CARGO PIT BETWEEN BS 747 TO BS 767 AT RBL 22 AND WL 158 PER [SRM 51-40-02-0G-0-D00069 (GENERAL - FASTENSDR SWAA2024122773066Bracket · corroded(DOT# A 147-08) FWD CARGO AFT BULKHEAD STA 520 LOWER SUPPORT BRACKET HAS CORROSION IN MUTIPLE AREAS BETWEEN RBL 24 TO LBL 24 UPPER SIDE OF BRACKET DOT # A147-09<[01] 01 - REMOVED AND REPLACED LOWER SUPPORT BRACKET IN FWD CARGO PIT AT AFT BULKHEAD STA 520 PER [SDR SWAA2024122673133Support Angle · corroded(151-#004) CORROSION ON FLOOR TO SIDEWALL SUPPORT FROM B.S 727H TO 847; LBL 22; WL 158.<[01] REMOVED; FABRICATED AND INSTALLED NEW Z-ANGLE FROM B.S 727H TO 847 AND SPLICE SIDEPLATE ON STA 727J+7'; LBL 22; WL 158 I.A.W SRM 53-00-53-2R-5;[02] VERIFIED ITEM 1<BR>SDR SWAA2024122673134Shield · corroded(151-#001) CORROSION ON SHIELD PLATE IN AFT CARGO COMPT. AT B.S 767 TO 787; RBL 22. WL 158.<[01] 01 - REMOVED AND REPLACED SHIELD PLATE IN AFT CARGO COMPARTMENT BETWEEN BS 767 TO BS 787 AT RBL 22 AND WL 158 PER [SRM 51-40-02-0G-0-D00069 (GENERAL - FASTENER INSSDR SWAA2024122772269Floor Panel · corrodedDOT 7L-015: AFT CARGO FLOOR PANEL 140EF IS CORRODED AT FASTENER HOLES<[01] EVALUATED AREA ON FLOOR PANEL 140EF; DAMAGE REMOVED HAS A MORE THAN 3 INCHES IN LENGHT; MORE OF THE LIMITS PERMITTED; THEREFORE IS OUT OF LIMITS I.A.W. SRM 53-00-53-1A-1. FABRICATED NEWSDR SWAA2024122772266Floor Panel · corrodedDOT 7L-016: AFT CARGO FLOOR PANEL 140BF IS CORRODED AT FASTENER HOLES<[01] EVALUATED ALLOWABLE LIMITS: DAMAGE IS MORE THE MAXIMUN LENGTH PERMITTED (MAXIMUN 3.0 IN) FOUND OUT OF LIMITS IAW SRM 53-00-53-1A-1 ITEM 5 B A AND FABRICATED NEW FLOOR PANEL 140 BF IAW ASDR SWAA2024122772270Floor Panel · corrodedDOT 7L-017: AFT CARGO FLOOR PANEL 140CF IS CORRODED AT FASTENER HOLES<[01] UPON FURTHER INVESTIGATION FOUND THERE TO BE A TOTAL OF 38 INCHES OF CORROSION WITH A MAX ALLOWED LENGTH OF CORROSION BEING 3 INCHES FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1 RECESDR SWAA2024122772271Floor Panel · corrodedDOT 7L-018: AFT CARGO FLOOR PANEL 140DF IS CORRODED AT FASTENER HOLES<[01] UPON FURTHER INVESTIGATION FOUND A TOTAL OF 42 INCHES OF CORROSION WITH A MAX ALLOWED LENGTH OF CORROSION BEING 3 INCHES FOUND PANEL 140DF TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1 RECESDR SWAA2024122772267Floor Panel · corrodedDOT 7L-019: AFT CARGO FLOOR PANEL 140AF IS CORRODED AT FASTENER HOLES<[01] UPON FURTHER INVESTIGATION FOUND A TOTAL OF 30 INCHES OF CORROSION WITH A MAX ALLOWED LENGTH OF 3 INCHES FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-1 RECEIVED REPLACEMENT MATERIAL PNSDR SWAA2024122771469Floor Panel · corrodedDOT 7L-009: FWD CARGO FLOOR PANEL 120CF HAS CORROSION AT FATENER HOLES<[01] EVALUATED AREA ON FLOOR PANEL 120CF; DAMAGE REMOVED HAS A MORE THAN 3 INCHES IN LENGHT; MORE OF THE LIMITS PERMITTED; THEREFORE IS OUT OF THE LIMITS I.A.W. SRM 53-00-53-1A-1<BR><BR>FABSDR SWAA2024122771471Floor Panel · corrodedDOT 7L-010: FWD CARGO FLOOR PANEL 120DF HAS CORROSION AT FASTENER HOLES<[01] EVALUATED ALLOWABLE LIMITS: DAMAGE IS MORE THE MAXIMUN LENGTH PERMITTED (MAXIMUN 3.0 IN) FOUND OUT OF LIMITS IAW SRM 53-00-53-1A-1 ITEM 5 B AND FABRICATED NEW FLOOR PANEL AMM 50-10-04SDR SWAA2024102852657Lamp · inoperativeAFT EMERGENCY EXIT SIGN 3EA LAMPS INOP<[01] R&R INOP LAMPS AT AFT EMERGENCY EXIT SIGN PER AMM 33-51-01. OPS CHECK GOOD.SDR SWAA2024102852656Lamp · inoperativeR1 DOOR EMERGENCY EXIT LIGHT 2EA LAMPS INOP<[01] R&R INOP LAMPS ON R1 OVERDOOR EMERGENCY EXIT SIGN PER AMM 33-51-01. OPS CHECK GOOD.SDR SWAA2024050983340Slide · out of positionFWD ENTRY DOOR SLIDE SKIRT SHOWING<[01] REINSTALLED FWD ENTRY DOOR LOWER SKIRT BACK IN PLACE PER AMM 25-66-01 AND A/C OKAY TO CONTINUE.SDR SWAA2024031463149Battery Pack · no testAFT EMERGENCY POWER BATTERY PACK AT STA 952 WL 290 LBL 14 WILL NOT HOLD CAPACITY FOR 15 MINS<[01] RNR AFT L/H BATTERY PACK PER AMM 33-51-06SDR SWAA2024031463148Battery Pack · no testMID EMERGENCY POWER BATTERY PACK AT STA 565 WL 213 LBL 68 WILL NOT HOLD CAPACITY FOR 15 MINS<[01] RNR MID L/H EMERGENCY POWER BATTERY PACK PER AMM 33-51-06SDR SWAA2024031463147Battery Pack · dischargedFWD EMERGENCY POWER BATTERY PACK AT STA 310 WL 290 RBL 6 WILL NOT HOLD CAPACITY FOR 15 MINS<[01] RNR R/H FWD EMERGENCY PACK PER AMM 33-51-06SDR SWAA2024031463146Battery Pack · no testFWD BATTERY AT STA 317 WL 290 LBL10 CAPACITY WILL NOT HOLD 15 MINS<[01] 01 - REMOVED AND REPLACED PER [AMM 33-51-06-960-802-MAX (POWER SUPPLY - BATTERY PACK REPLACEMENT - PERMANENT)]SDR SWAA2023121832599Flashlight · inoperativeEMERGENCY FLASHLIGHT AT AFT CABIN F/O INBD SIDE NOT TESTING<[01] RESEATED EMERGENCY FLASH LIGHT AT AFT CABIN F/O INBD SIDE IAW AMM25-64-00.OPS CK GOOD.SDR SWAA2023110317144Battery · inoperativeAFT GALLEY INBOARD EMERGENCY FLASHLIGHT INDICATOR FLASHES RED<[01] R&R AFT GALLEY INBOARD EMERGENCY FLASHLIGHT BATTERY PER AMM 25-64-00SDR SWAA2022072733321Light · faultyFA NOTED A ELECTRICAL SMELL IN AFT GALLEY; SWITCHED OFF WORK LIGHT; SMELL WENT AWAY THEN CAME BACK AND DIVERT TO HNL. INSP A/C AND ISOLATED ODOR TO AFT GALLEY WORK LIGHT C/W CONDITIONAL INSP AMM 05-51-56. OPS CHECKED AFT DOOR AREA HEATER PER AMM 21-45-00 OPSSDR SWAA2021120950519Light · inoperativeSIDEWALL LIGHT INOP AT EMERGENCY EXIT SEAT 14F. ; / [01] OK TO CONT. PER MEL# 33-21-01A SP1 AUTH# 37473. R/R EMERGENCY EXIT SIDEWALL LIGHT ASSY. AT 14 DEF IAW AMM 33-21-00. OPS CK GOOD.
Back to N8733M