N918SW
Service difficulty reports · 210
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N918SW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N918SW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA200922622Connector · looseEMERGENCY EXIT LIGHT BY MAIN DOOR INOP. (FLT 6639) RE-SEATED CONNECTOR.SDR SWIA200922464Light · inoperativeNR 2 AFT CEILING EMERGENCY LIGHT INOP. (FLT 5849) RELAMPED EMERGENCY LIGHT.SDR SWIA200922293Light · damagedEMERGENCY FLOOR LIGHTING AFT STRIP DAMAGED. (FLT 6510) REPLACED LIGHT STRIP SECTION.SDR SWIA200922269Light · inoperativeCABIN EMERGENCY LIGHT IN CEILING INOP. (FLT 6484) RELAMPED EMERGENCY LIGHT.SDR SWIA200922166Selector Valve · failedGEAR DISAGREE DISPLAYED. (FLT 6589) REPLACED NLG SELECTOR VALVE (GEAR DOORS).SDR SWIA200921204Connector · looseFLT 6562 - EMERGENCY EXIT LIGHT BY CABIN DOOR NOT ILLUMINATING. RESEATED CONNECTOR.SDR SWIA200921176Bracket · out of adjustFLT 6503 - NOSE GEAR WOULD NOT RETRACT AFTER TAKEOFF. ADJUSTED NOSE GEAR PROX SENSOR BRACKET.SDR SWIA200921006Battery Pack · inoperativeFLT 5855 - EMERGENCY LIGHTS INOP. REPLACED ALL FOUR EMERGENCY LIGHT BATTERIES.SDR SWIA200820448Bracket · crackedC-CHECK, FS 280 LEFT BRACKET, RIGHT SIDE OF COCKPIT FLOOR OPENING, CRACKED. REPAIRED PER REO.SDR SWIA200820447Support · crackedC-CHECK, FS 280 LBL 9 SUPPORT CLIP CRACKED. REPAIRED PER REO.SDR SWIA200820446Support · crackedC-CHECK, FS 280 RBL 9 SUPPORT CLIPS CRACKED. REPAIRED PER REO.SDR SWIA200820445Support · crackedC-CHECK SUPPORT AND CLIP AT FS 625 CRACKED. REPLACED PER SRM.SDR SWIA200820444Isolator · crackedC-CHECK, THREE ISOLATORS FORWARD SIDE OF AFT PRESSURE BULKHEAD CRACKED. REPLACED PER SRM.SDR SWIA200819815Acm · failedFLT 6006 - RECEIVED A PACK HI TEMP CAUTION MESSAGE ALONG WITH REPORTED LIGHT SMOKE IN CABIN. REPLACED RIGHT PACK AIR CYCLE MACHINE IAW AMM 21-12-00. OPS AND LEAK CHECK GOOD, P/N 782790-15, S/N OFF 200106038.SDR SWIA200819706Adg · deployedADG DEPLOYED DURING FLIGHT. RESTOWED ADG AS REQUIRED.
SDR SWIA200718997Pump · leakingFLT 6670 - SYSTEM 2 HYDRAULIC QUANTITY DROPPED TO 0 PERCENT IN FLIGHT. REPLACED NR 2 ENGINE DRIVEN HYDRAULIC PUMP IAW AMM 29-11-01. OPS CHECK AND LEAK CHECK GOOD.SDR SWIA200718988Rib · damagedRIGHT WING RIB AT WS389 IS DAMAGED. REPLACED RIGHT WING RIB AT WS 389 IAW REO 601R-57-21-899.
SDR SWIA200718987Spar · damagedFORWARD OUTBOARD WING SPAR ON RIGHT WING HAS DAMAGE AT WS 339. REPAIRED WING SPAR DAMAGE AT WS 335-353 IAW CRJ 200 REO 601R-57-21-898.
SDR SWIA200718228Acm · failedLEFT PACK BRIEFLY HAS AN ODOR OF SMOKE, MADE A LOUD NOISE AND THEN OVERTEMPED. REPLACED LEFT AIR CYCLE MACHINE IAW AMM 21-51-10-401.SDR SWIA200718100Sign · missingAFT RED EMERGENCY EXIT SIGN IS MISSING. REPLACED AFT RED EMERGENCY EXIT SIGN IAW AMM 33-51-00.SDR SWIA200717755Window · crackedDESCENDING THRU 9,000 FT RIGHT WINDOW CRACKED. REPLACED RIGHT SIDE WINDOW IAW CRJ MM 53-12-01 AND RII 56-220-1000, PN OFF: NP139322-001 SN OFF: 02014H6515.SDR SWIA200717663Selector Valve · malfunctionedUPON GEAR EXTENSION GOT A GEAR DISAGREE AND TOWER CONFIRMED THAT THE NOSE GEAR WAS STILL UP. PERFORMED MANUAL RELEASE GEAR EXTENSION AND RECEIVED THREE GREEN INDICATIONS. REPLACED NLG SELECTOR VALVE ASSY IAW CRJ 200 MM 32-33-10. OPERATIONAL CHECKS GOOD.SDR SWIA200717662Selector · malfunctionedUPON GEAR EXTENSION, GOT A GEAR DISAGREE WITH THE NOSE GEAR REMAINING UP. EXTENDED GEAR MANUALLY WITH ALL GEAR EXTENDING NORMALLY. REPLACED NLG SELECTOR VALVE ASSY IAW CANDAIR REGIONAL SET MM 32-22-25 PG 401.SDR SWIA200717654Valve · malfunctionedAFTER SELECTING GEAR DOWN NOSE GEAR DID NOT COME DOWN. RECYCLED GEAR HANDLE THREE TIMES, NO HELP. MANUALLY EXTENDED NOSE GEAR. REPLACED NLG PRIORITY VALVE IAW RJ 200 MM 32-33-15. OPERATIONAL CHECKS GOOD, P/N; 4622.SDR SWIA200617611Floorbeam · crackedFS 280 LBL9 LOWER ANGLE CRACKED ON FLOOR SUPPORT BEAM AND RBL9 I/B AND O/B 280 CLIPS ARE CRACKED, DISCOVERED DURING C-CHECK INSPECTION. INSTALLED REPAIR ANGLES AND CLIPS AT STA 280 RBL9 LOWER PER CRJ200 REO 601R 53-171 REV 'C' REPAIR SCHEME 'B' .SDR SWIA200617610Frame · crackedFS 280 LBL9 LOWER FRAME/EVIDENCE OF CRACKS ON FLOOR SUPPORT BEAM AND LBL9 I/B AND O/B 280 CLIPS ARE CRACKED, DISCOVERED DURING C-CHECK INSPECTION. INSTALLED I/B AND O/B CLIPS AND FILLERS.SDR SWIA200616213Trim Switch · inoperativeCREW REPORTS NR 2 STAB TRIM SWITCH INOP. REPLACED NR 2 STAB TRIM SWITCH REF AMM 27-41-05, OPERATIONAL CHECKS GOOD.SDR SWIA200516004Pdu · malfunctionedON APPROACH "FLAPS HALFSPEED" STATUS MESSAGE CAME ON. REPLACED FLAP PDU PER CRJ MM 27-51-00. OPERATIONAL CHECK GOOD.SDR SWIA200515739Floorbeam · crackedMAIN CABIN OVER PRESSURE FLOOR AT STA 461.00 BL 9 FLOORBEAM ANGLE CRACKED. ITEM FOUND AT C-CHECK INSPECTION. FLOORBEAM INSTALLED AS REQUIRED IAW EO 600-31068 AND SRM 51-42-06; 51-42-21.SDR SWIA200515738Angle · crackedCRACKED SUPPORT ANGLE FS 621; LBL 45; WL 73.5. ITEM FOUND AT C-CHECK INSPECTION. REPAIR PARTS INSTALLED AS REQUIRED AND ALL WORK DONE IAW REO 601R-53-61-004 SRM 51-42-06 AND 51-42-21.SDR SWIA200515737Floorbeam · crackedL-BRACKET CLIP AT INBOARD RIGHT HAND 9' LBL ATTACHMENT TO 280 FS FLOORBEAM IS CRACKED AT TOP RADIUS. ITEM FOUND AT C-CHECK INSPECTION. INSTALLED CLIP STA 280 INBOARD RBL 9 IAW CRJ200 SRM 51-42-06 PG 1-17.SDR SWIA200515736Clip · crackedL-BRACKET (CLIP) AT OUTBOARD LEFT HAND 9' LBL ATTACHMENT TO 280 FS BEAM IS CRACKED. ITEM FOUND AT C-CHECK INSPECTION. INSTALLED CLIP LEFT HAND INBOARD STA 280.00 LBL 9 IAW CRJ200 SRM 51-42-06 PG 1-4.SDR SWIA200514786Adc · malfunctionedDURING FLIGHT FROM ORD, CAPTAIN`S ALTIMETER JUMPED ERRATICALLY BETWEEN 22.00 - 32.00. UNABLE TO RESET WITH BARO KNOB TO PROPER SETTING. DIVERT TO CAK. REMOVED AND REPLACED NR 1 ADC IAW AMM 34-11-00. OPERATIONAL CHECK GOOD. A/C REMAINS CAT II & RVSM.SDR SWIA200514487Pressure Switch · malfunctionedON SHORT FINAL RECEIVED SPOILERONS FAULT AND OUTBOARD GROUND SPOILER FAULT STATUS MESSAGES. REMOVED AND REPLACED ANCP LOW PSI SWITCH 1B. PERFORMED SECU CHECKS IAW 27-61-05. OPERATIONAL CHECK GOOD.SDR SWIA200514408Window · crackedCAPTAINS SIDE WINDOW HAS MULTIPLE CRACKS THAT SPAN THE LENGTH OF WINDOWS. REMOVED AND REPLACED LT SIDE WINDOW IAW AMM 56-12-01. P/N NP139322-5, S/N OFF 01352H5316.SDR SWIA200514327Control Unit · malfunctionedSTAB TRIM AND MACH TRIM CAUTION ILLUMINATED AFTER TAKEOFF. REMOVED AND REPLACED HSTCU IAW CRJ 200 MM 27-41-01. OPERATIONAL CHECK GOOD.SDR SWIA200414091Lamp · burned outRIGHT FORWARD EXTERIOR EMERGENCY EXIT LIGHT INOPERATIVE. RELAMPED EXTERIOR EMERGENCY EXIT DOOR LIGHT IAW CRJ MM 33-51-21. OPERATIONAL CHECK GOOD.SDR SWIA200414065Battery · inoperativeBACK EMERGENCY LIGHTS INOPERATIVE. REMOVED BATTERY AND CLEANED CONTACTS. OPERATIONAL CHECK GOOD.SDR SWIA200413975Battery · inoperativeEMERGENCY LIGHTS AFT OF EXIT ROW INOPERATIVE. REMOVED EMERGENCY BATTERY AND CLEANED CONTACTORS, RE-INSTALLED AFT BATTERY. OPERATIONAL CHECK GOOD.SDR SWIA200413946Control Unit · malfunctionedFLAPS FAIL MESSAGE ON APPROACH TO LANDING. REMOVED AND REPLACED FECU IAW CRJ MM 27-51-05. OPERATIONAL CHECK GOOD.SDR SWIA200413805Actuator · malfunctionedNR 2 STAB TRIM FAILED TO ENGAGE. REMOVED AND REPLACED HSTA, IAW CH. 27-42-01 AND REPLACED MCU IAW MM CH. 27-42-05. OPERATIONAL CHECK GOOD. P/N: 7062-3 S/N OFF: 117.SDR SWIA200413763Switch · malfunctionedON APPROACH STAB TRIM CHANNEL 1 DISENGAGED. REMOVED AND REPLACED CAPTAINS STAB TRIM SWITCH AND STAB TRIM/MACH TRIM POND ASSY IAW MM 27-41-00 AND 27-41-25. OPERATIONAL CHECK GOOD.SDR SWIA200413682Trim Panel · malfunctionedINFLIGHT, MACH TRIM AND CHANEL 1 STAB DISENGAGED. REMOVED AND REPLACED STAB TRIM/MACH TRIM PANEL FOR IAW CRJ 200 MM 27-41-20. OPERATIONAL CHECK GOOD.SDR SWIA200413543Control Unit · looseFLIGHT SPOILERS FAULT STATUS MESSAGE DISPLAYED ON ED2. RESECURED NR 1 SECU IN RACK. OPERATIONAL CHECK GOOD.SDR SWIA200413423Warning Light · illuminatedFLT SPOILERS FAULT STATUS MSG CYCLES ON AND OFF, TAXIED BACK TO GATE. PERFORMED FAULT ISOLATION PROCEDURES OF FLIGHT SPOILERS SYSTEM. NO DEFECTS NOTED.SDR SWIA200413318Pdu · malfunctionedFLAPS HALFSPEED STATUS MESSAGE. REMOVED AND REPLACED POWER DRIVE UNIT FOR FLAPS IAW 27-52-01. OPS CHECKS GOOD.SDR SWIA200412989Bulb · inoperativeMAIN CABIN DOOR EXTERIOR EMERGENCY EXIT LIGHT INOP. RELAMPED BULB, OPS CHECK GOOD.SDR SWIA200412854Actuator · malfunctionedFLAPS FAIL CAUTION MESSAGE ON WHEN FLAPS SELECTED AT APPROXIMATELY 13,000 FT. REMOVED AND REPLACED RIGHT NR 1 AND LEFT NR 1 ACTUATOR (FLAP), IAW 27-53-01, 27-53-05, AND RII 27-412. OPS CHECKS GOOD. S/N OFF RIGHT: 3392.SDR SWIA200412821Bpsu · malfunctionedFLAPS FAIL AT -0- WHEN SELECTED. REMOVED AND REPLACED RIGHT AND LEFT FLAP BPSU, LEFT FLAP ACTUATOR IN THE NUMBER 3 POSITION AND THE RIGHT NR 3 FLAP ACTUATOR. RIGHT BPSU S/N OFF: 0801, ACTUATOR P/N: 853D100-19, LEFT S/N OFF: 1945. RIGHT S/N OFF: 1941. OPS SDR SWIA200412836Floorbeam · crackedCARGO PIT FS 621.00 RBL 42.0 FLOORBEAM ANGLE IS CRACKED. DISCOVERED DURING C-CHECK INSPECTION. REPAIRED DAMAGE IAW CRJ REO 601R-53-61-117 REV-A.