N919XJ
Service difficulty reports · 148
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N919XJ' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N919XJ' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR REXA2015100800936Angle · corrodedCORROSION ON LT OVERWING SILL ANGLE AT FS 708.00 & FS 797.00 AROUND FASTENER HOLE. REPAIRED CORROSION IAW SRM 53-41-51-101-001-A02 & EA REPAIR NR CRJ953-03720.SDR REXA2015100700945Fairing · crackedLEFT ENG LOWER AFT HINGE LINE FAIRING 433BB HAS APPROX 1" CRACK THROUGH FASTENER HOLE.
REINSTALLED CLIP & C CHANNELS TO CN 24-4230-206 IAW SRM 51-42-06-001-001-A01 & SRM 51-42-10-001-001-A01. EXTERIOR PAINT ON FAIRING 433BB IAW REO 670-78-33-998.SDR REXA2015100700943Drag Angle · crackedPASSENGER DOOR, AFT DRAG ANGLE CRACKED, PREVIOUS REPAIR. REPAIRED CRACKED PAX DOOR IAW SRM 52-11-04-201-002-A01.SDR REXA2015100600940Panel · chafedPANEL 599AB HAS A DEEP GOUGE ON THE INBD EDGE OF THE PANEL. RECEIVED NEW PANEL 599AB, REFER TO MASTER PANEL BOOK M-212 PG 74 FOR REMOVAL & INSTALLATION. LOCATED, DRILLED & COUNTERSUNK NEW PANEL 599AB, PN 601R13440-1 IAW SRM 51-40-11-001-001-A01.SDR REXA2015100600939Panel · chafedPANEL 584JB IS CHAFED AT CUT OUT FOR FLAP VANE ACT ROD. RECEIVED NEW PANEL 584JB, PN CC670-14178-1, REFERENCE MASTER PANEL BOOK M212 PAGE 76 FOR REMOVAL & INSTALL OF PANEL 584JB. LOCATED, DRILLED & COUNTERSUNK NEW PANEL 584JB, PN CC670-14178-1, IAW SRM 51-40SDR REXA2015100600938Panel · chafedPANEL 584EB IS CHAFED AT CUT OUT FOR FLAP VANE ACT ROD. RECEIVED NEW PANEL 584JB, PN CC670-14178-1. REFERENCE MASTER PANEL M212 PG 75 FOR REMOVAL & INSTALLATION. LOCATED, DRILLED & COUNTERSUNK NEW PANEL 584EB, PN CC670-14177-1, IAW SRM 51-40-11-001-001-01.SDR REXA2015100400969Door Sill · corrodedCORROSION ON SERVICE DOOR SURROUND STRUCTURE, LOWER AFT SILL FROM FS 349.00 - 364.00. REO:670-53-00-390, REV DATED 01/22/14 COMPLIED WITH IN ITS ENTIRETY.SDR REXA2015100100944Mechanism · bindingRIGHT FWD, AFT OVERWING EMER EXITS FAIL THE DOOR HANDLE FUNCTIONAL TEST. DOORS OPEN AT 55 LBS, SHOULD BE UNDER 40 LBS. REMOVED FWD EMER EXIT DOOR LINER FOR ACCESS IAW AMM 25-26-09-000-801 A02. LUBRICATED FWD OVERWING EXIT IAW AMM 12-20-52-640-816 A01, DOOR SDR REXA2015092800972Handle · lack of lubeCREW HATCH EXTERNAL HANDLE WILL NOT POP OUT WHEN ENGAGING PUSH BUTTON. LUBRICATED CREW ESCAPE HATCH & SUCCESSFULLY DISENGAGED & RE-ENGAGED EXTERNAL HANDLE TEN TIMES IAW AMM 12-20-525-640-804 A01.SDR REXA2015060900570Engine · flamed outDURING CLIMB OUT AT 296KTS AT F190 LOUD BANG RT ENG FLAME OUT, VIB N2, FOLLOWED BY ENG OIL P-199, FOLLOWED CHECK LIST. R & R RT ENG IAW 900-72-430-902 & 900-72-430-906. REFER TO 527345 NON-ROUTINE WORK CARD. EMER WAS DECLARED, ACFT LANDED SAFELY WITHOUT INCSDR REXA2015041400404Battery Pack · dischargedDURING FLIGHT ATTENDANT PREFLIGHT INSPECTION, THE OVERHEAD, EMER EXIT SIGN & 2 SEAT LEVEL SIGNS AT ROW 13 DO NOT ILLUMINATE. R & R EPSU BATTERY PACK & CHARGER IAW 33-51-17. OPERATIONS CHECKED GOOD. NO FURTHER DEFECTS NOTED AT THIS TIME.SDR REXA2015041400402Battery Pack · dischargedNOTED EMER LIGHT AT SEAT 10 & 11 ARE INOPERATIVE. REPLACED BATTERY PACK AT PS37 PN ON & OFF AD-2013-1A IAW AMM CH 33-51-17. XN OFF 145968, SN ON 79988 IAW JC 33-900-701. OPERATIONS CHECKED GOOD.SDR REXA2015032900352Flashlight · inoperativePILOT SIDE FLASHLIGHT INOPERATIVE. R & R PILOT FLASHLIGHT IAW AMM 25-61-02. OPERATIONS CHECKED GOOD.SDR REXA2015030500282Light · unsecureLUMINESCENT STRIPING FOR EXIT LIGHTING ON FLOOR IN GALLEY UNSECURED. RESECURED FLOOR STRIP AS REQUIRED OK FOR SERVICE.SDR REXA2014122801237Door Frame · obstructedMAIN BOARDING DOOR WOULD NOT OPEN. TRIED BOTH INSIDE AND OUTSIDE HANDLES. COULD NOT GET THEM TO BUDGE. MAINTENANCE APPLIED FORCE ON BOTH INSIDE AND OUTSIDE SIMULTANEOUSLY, WHICH RESULTED IN A LOUD, SHARP, BANG, AND THE DOOR OPENING. CLEARED DEBRIS FROM DOSDR REXA2014090900943Sign · inoperativeUPPER FWD FACING OVERWING EMER EXIT SIGN DOES NOT LIGHT. REPLACED PS43 IAW 33-51-17. OPERATIONS CHECKED GOOD.SDR REXA2014013000173Panel · chafedRIGHT WING INBD FLAP NR 3 VANE PANEL 684ET CHAFFED. LOCATED & DRILLED PANEL RECEIVED IAW CRJ900 SRM 51-42-06-001-001-A01.SDR REXA2014012900172Fireshield · chafedRIGHT LOWER COWL ENG DRAINS FIRE SHIELD IS CHAFED AT THE FWD OTBD CORNER. REPAIR IAW EO R540490 USING ONE CORNER FROM A NEW FIRE SHIELD PN CN624-3170-203. RT LOWER TR IS PN CN 624-0104-003 & SN SB087. REPAIRED CHAFE ON RT LOWER COWL ENG DRAIN FIR SHIELD IAWSDR REXA2014012900171Skin · chafedFUSELAGE SKIN & RIVET CHAFED AT FS 918.5, STRINGER 27 FROM EXCESSIVELY LONG SCREW BODY FAIRING 196DR. REPAIRED CHAFED IN FUSELAGE SKIN AT FS 918.5 AT STRINGER 27 IAW CRJ900 EO R3528.SDR REXA2014012900170Strap · crackedJOINT STRAP AT PANEL 195DL & 196DR AFT LOWER FUSELAGE CTR SEAM CRACKED AFT END R & R JOINT STRAP ON PANEL 196DR & 195DL IAW NR 5670538200021. NO FURTHER DAMAGE FOUND.SDR REXA2014012700169Panel · chafedLEFT INBD FLAP INBD VANE PANEL 684ET CHAFED. OBTAINED NEW LT INBD FLAP INBD VANE PANEL 684ET. BACK DRILLED & COUNTERSUNK PANEL 684ET IAW CRJ 900 SRM 51-40-11. APPLIED PRIMER & TOP COAT IAW CRJ 900 SRM 51-25-06 7 CRJ 900 SRM 51-25-16.SDR REXA2014012600168Panel · chafedRIGHT INBD WING FLAP PANEL 684JB HAS CHAFE DAMAGE. REPLACED RT INBD WING FLAP PANEL 684JB WITH PN CC670-14178-1. DRILL & COUNTERSUNK HOLES IAW CRJ 900 SRM 51-40-11-001-001-A01 IAW CRJ900 IPC 57-51-32.SDR REXA2014012300154Pin · backed outLEFT WING, AFT OVER WING EMERGENCY LIGHT WIRE, PULLED OUT. RECEDED PIN INTO CONNECTOR IAW CRJ 900 ESPM 20-16-05. PERFORMED OPERATIONAL TEST OF EXTERIOR EMERGENCY LIGHTS IAW CRJ 900 AMM 33-51-15-710-801-A01. OPERATIONS CHECKED GOOD AT THIS TIME.SDR REXA2013121702225Target · defectiveAFTER TAKEOFF WE PUT THE LG HANDLE TO THE UP POSITION & THEN WE GOT THE GEAR DISAGREE MASTER WARNING MESSAGE & THE PROX SYS FAULT 1 STATUS MESSAGE. RAN THE NON-NORMAL LIST & LANDED AT DSM, THE GEAR NEVER CAME UP. ALL THE GEAR PINS WERE OUT. INSTALLED TARGETSDR REXA2013110502170Light · missingEMERGENCY LIGHT STRIP IN GALLEY IS MISSING. REPLACED EMERGENCY LIGHT IAW AMM 33-51-01.SDR REXA2013092501845A/C Pack · odorAFTER TAKEOFF, STRONG SULFUR ODOR NOTICED. LEFT PACK OAT 65C AND WOULDN'T COOL OFF. SELECTED MANUAL MODE TEMP CONT TEMP COOLED OFF. ODOR WENT AWAY. INSPECTED LEFT DUCT FOR PROBLEMS. NO ODOR DETECTED.SDR REXA2013081601469Fuel Nozzle · leakingF/A REPORT A STRONG ODOR IN CABIN. ODOR BEGAN WHEN PACKS STARTED. STRONG "OILY" ODOR. ODOR IMPROVED AFTER A TIME, BUT REMAINED IN THE CABIN. ODOR SEEMED STRONGER IN SOME AREAS. PRIMARILY AROUND ROWS 5 AND 6. WHEN PACKS WERE OFF, ODOR WENT AWAY. FOUND LEAKSDR REXA2013041400486Glowstrip · missingPHOTO LUMINESCENT STRIP IS MISSING FROM ROW 7AB. OK TO DEFER PHOTO LUMINESCENT STRIP AT 7AB PER MEL 33-51-1G. MOC NOTIFIED. PLACARD INSTALLED MM02 UPDATED. REPLACED PHOTO LUMINESCENT STRIP AT SEAT 7AB IAW 33-51-01. P/N PL88-900LH00. ITEM REMOVED FROM MM0SDR REXA2012070500940Battery Pack · inoperativeALL EMERGENCY LIGHTS AFT OF EMERGENCY EXITS ARE INOPERATIVE. REMOVED AND REPLACED EPSU BATTERY PACK PS38 IAW 33-51-17. OPS CHECKED GOOD.SDR REXA2012030400047Battery · dischargedNOTED MULTIPLE INTERIOR AND EXTERIOR EMERGENCY LIGHTS ARE INOP. REPLACED BATTERIES AT PS38 AND PS43. REF CRJ900 AMM CH 33-51-17. P/N 2013-1A. S/N ON AT PS38 74272. S/N ON AT PS43 84841. ALL CHECKS GOOD.SDR MALA110245Intercostal · corrodedINTERCOSTAL AT FS 364.00 STRINGER 27 LT HAS CORROSION. REMOVED CORRODED INTERCOSTAL AND INSTALLED NEW INTERCOSTAL IAW SRM 51-42-06.SDR MALA110244Floorbeam · corrodedCOCKPIT FLOORBEAM ANGLE CORRODED ON FWD SIDE OF BS 280, MARKED DOT 68A004. R & R FLIGHT DECK FLOORBEAM ANGLE AT FS 280 IAW SRM 51-42-00.SDR MALA110243Floor Support · corrodedCABIN FLOOR SUPPORT AT SERVICE DOOR CORRODED, MARKED DOT 68A008. REMOVED CORROSION FROM CABIN FLOOR SUPPORT IAW SRM 51-21-06, SUPPORT IS WITHIN LIMITS IAW SRM 53-21-23 RE APPLIED FINISH IAW SRM 51-25-16.SDR MALA110242Threshold · corrodedSERVICE DOOR THRESHOLD CORRODED, MARKED DOT 68A009. R & R SERVICE DOOR THRESHOLD IAW SRM 51-42-06.SDR MALA110241Web · crackedFWD EQUIPMENT BAY RT SIDE WEB IS CRACKED NEXT TO ADG PUMP. FABRICATED & INSTALLED A TITANIUM REPAIR DOUBLER IAW REO 670-53-11-509.SDR MALA110240Sill · corrodedCABIN FLOOR SILL CORRODED ON AFT SIDE OF 280 BEAM RT SIDE AT RBL 43, MARKED DOT 68A005. REMOVED LIGHT SURFACE CORROSION ON AFT SIDE OF 280 BEAM RT SIDE AT RBL 43, SRM 51-21-06 AND FINISH COATS SRM 51-21-16.SDR MALA110239Bulkhead · corrodedSTATION 280 BULKHEAD CORRODED ON LT SIDE OF FLT DECK ENTRANCE ON UPPER SIDE OF 280 BEAM, MARKED DOT 68A006. REMOVED 3 BLIND RIVETS TO FACILITATE THE REMOVAL OF CORROSION. REMOVED CORROSION FROM STA 280 BULKHEAD IAW SRM 51-21-06. UT INSPECTION SHOWED A MATERSDR MALA110134Light · damagedFWD GALLEY AREA EMERGENCY FLOOR PATH LIGHTING DAMAGED. REPLACED FWD GALLEY AREA FLOOR PATH LIGHTING IAW AMM 33-51-01.SDR MALA110079Stringer · damagedFOUND DAMAGED STRINGER NR 8R AT STA 1155 DAMAGE DEPTH .053, W .2958, L .622. DAMAGE REMOVED FROM STR 8R ES 1162,00 AND TEMPORARY REPAIRED IAW REO 690-53-61-161. ALSO, INITIATED PWI TO COMPLETE PERMANENT REPAIR WITHIN 1200 FLT HRS.SDR MALA110071Light · missingEMERGENCY FLOOR PATH LIGHT STRIP FWD LT GALLEY MISSING TOP PIECE. INSTALLED EMERGENCY FLOOR PATH STRIP PIECE AND FILM BY FWD GALLEY IAW MM 33-51-01.SDR MALA110042Mount · crackedNOTED CRACK THRU TOP RIVET ON AFT DOOR MOTOR MOUNT. REPAIRED DAMAGE IN ZONE 4 ON PAX AFT STAIR SIDE PANEL USING REO 670-52-11-104 AS REF. ACCOMPLISHED EDDY CURRENT INSPECTION OF REPAIRED AREA AND CUTOUT EDGES PER NDTM 51-20-006 CRACK FREE AT THIS TIME.SDR MALA20110041Drag Angle · crackedNOTED 1,5 INCH CRACK IN RADIUS OF AFT DRAG ANGLE NEAR THE SUPPORT WHEEL PULLEY BRACKET AREA ON FWD PAX DOOR. REPAIRED AFT DRAG ANGLE USING SRM 52-11-04 & REO 690-52-11-026 AS REF.SDR MALA100123Light · detachedF/A REPORTS LUMINESCENT STRIP IN FRONT OF GALLEY TRASH CAN IS DETACHED. REPLACED LUMINESCENT STRIP, FRONT GALLEY LT SIDE.SDR MALA100109Connector · damagedUPON INSP FOUND EMERGENCY FLOOD LIGHT IN ROW 2 TO BE INOP. REPOSITIONED PIN ON CONNECTOR.SDR MALA100012Light · missingFLOORTRACK LIGHTING MISSING FROM GALLEY 2. REPLACED EMERGENCY FLOOR TRACK LIGHTING IN GALLEY 2.SDR MALA090155Glowstrip · looseGLOW STRIP ON FLOOR BY FRONT GALLEY GARBAGE CAN NEEDS TO BE RESECURED. REPLACED EMERGENCY FLOOR PATH MARKING AT LT GALLEY.SDR MALA090123Light · looseFA REPORTED THAT THE FLOOR TRACK LIGHTING STRIP WAS LOOSE. REPLACED FLOOR LIGHTING STRIP.SDR MALA080038Unknown · odorHOT PLASTIC SMELL NOTED IN FLIGHTDECK DURING DESCENT, LANDING ,TAXI IN DTW. ARRIVED AT A/C COULD NOT SMELL ANYTHING. RAN PACK'S FULL NOT COULD NOT SMELL ANYTHING JUST THE NEWNESS OF THE A/C COULD NOT DUPLICATE THE SMELL. INSPECTED THE VENT'S COULD NOT SEE A