N941LT
Service difficulty reports · 231
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N941LT' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N941LT' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SIMA201904084007Fitting · chafedLH AILERON DAMPNER FITTING HAS CHAFING MARKS ON THE INSIDES OF TH FITTING. LH AILERON FITTING TO PCA HAS (2EA) INBD MIGRATED HAT BUSHINGS. -C/A-REMOVED AND REPLACED LH AILERON DAMPNER FITTING IAW EO-EM-27MR-112. RAR'D PCA ATTACH FITTING (INCLUDES HAT BUSHINSDR SIMA20190404001Bushing · migratedRH AILERON DAMPER FITTING HAD MIGRATED HAT BUSHING. RAR RH AILERON DAMPER FITTING IAW EO- EM-27MR-112.SDR SIMA201904083002Frame · corrodedFRAME 22 RT CORRODED AT FLOOR LEVEL. C/W REPAIR OF FR 22R IAW SRM 53-00-04RE AND 51-40-02.SDR SIMA2019040432909Door Sill · corrodedNUMEROUS SPOTS OF CORROSION ON CARGO SILL BETWEEN FRAMES 65 TO 68. -C/A-C/W RAR OF CARGO DOOR SILL IAW SRM 51-40-02.SDR SIMA2019040832807Support · crackedBAGGAGE DOOR MECHANISM FORWARD SUPPORT IS CRACKED. INSTALLED NEW SUPPORT IAW SRM 51-10-02.SDR SIMA2019040432806Shear Tie · crackedFRAME 68 SHEAR CLIP BETWEEN STR 7L AND 8L HAS 1 CRACK. ( 1,5 INCH TOTAL CRACK LENGTH) -C/A-INSTALLED FR68 SHEAR CLIP IAW SRM 51-40-02SDR SIMA2019040432805Shear Tie · crackedFRAME 73 SHEAR CLIP AT STRINGER 10L HAS 2 CRACKS. (1.5 INCH TOTAL CRACK LENGTH)-C/A-REPLACED SHEAR CLIP IAW SRM 51-40-02SDR SIMA2019040432804Support · crackedCARGO DOOR HOLD OPEN SUPPORT REINFORCEMENT AT FRAME 68 STRINGER 15L HAS 2 CRACKS. (1 INCH IN LENGTH TOTAL)-C/A-REPLACED SUPPORT REINFORCEMENT IAW SRM 51-40-02SDR SIMA201904013Intercostal · crackedNLG FORWARD INTERCOSTAL CRACKED-C/A-REPLACED INTERCOSTAL IAW SRM 51-40-02.SDR SIMA20190323006Connector · brokenFOUND LAST:LT FLOOR PROXIMITY EMERGENCY LIGHT (CLOSES TO THE LAV DOOR) HAS A BROKEN CONNECTOR. C/A-COMPLETE:REPLACED FLOOR PROX EMERGENCY LIGHT CONNECTOR IAW SWPM 20-21-00.SDR SIMA20190323003Light · damagedFOUND FLOOR EMERGENCY LIGHT STRIPS SIDEWALL ASSEMBLIES CRACKED, CHIPPED AND BROKEN BROKEN. C/A-COMPLETE:RAR FLOOR EMERGENCY LIGHT STRIPS IAW AMM 33-50-12.SDR SIMA20190323004Light · defectiveLT FLOOR PROXIMITY EMERGENCY LIGHT (IN THE FLOOR) AT FRM54. CONNECTOR WILL NOT CONNECT WITH THE PROX LIGHT CONNECTOR. C/A-COMPLETE: REPLACED LT FLOOR PROX EMERGENCY LIGHT @ FR54 IAW SWPM 20-21-00.SDR SIMA20190323005Wire · brokenLT FLOOR PROXIMITY EMERGENCY LIGHT WIRE BROKEN AT FRM54. C/A-COMPLETE: REPAIRED LT FLOOR PROXIMITY EMERGENCY LIGHT WIRE IAW SWPM 20-21-00.SDR SIMA20190308002Light · inoperativeSERVICE DOOR EMERGENCY LIGHT INOP. C/A-RAR SERVICE DOOR EMERGENCY DOOR LIGHT LAMP IAW 33-50-10-000-801-A AND 33-50-10-400-801-A. OPS CHECK GOOD.SDR SIMA20190305003Light · inoperativeSERVICE DOOR EMERGENCY LIGHT INOP. C/A-REMOVED AND REPLACED SERVICE DOOR EMERGENCY LIGHT IAW AMM 33-50-09-000-801-A AND 33-50-09-400-801-A. OPS CHECK GOOD. END.SDR SIMA20190220003Anti-Ice System · malfunctionedWG A/ICE FAIL DURING PNEUMATIC TEST AIRBORNE. RECEIVED CMC MESSAGE WING 2 ANTI-ICE LEAK INSPECTED NR 2 ACM AREA AND WING ROOT FOR LEAKS NO LEAKS NOTED PERFORMED. OPS CHECK OF ANTI-ICING SYSTEM IAW AMM 30-00-00 OPS CK OK.SDR SIMA201812187003Light · inoperativeLH OVERWING EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED LH OVERWING EMERGENCY LIGHT IAW EMB AMM 33-50-10 OPS CHECK GOODSDR SIMA201812032001Lamp · inoperativeLH OVERWING EMERGENCY LIGHT INOP-C/A-REMOVED AND REPLACED LAMP IN LH OVERWING EMERGENCY LIGHT ASSEMBLY IAW EMB AMM 33-50-10-000-801-ASDR SIMA20181109001Light · inoperativeLT OVERWING AFT EMERGENCY LIGHT INOP. REMOVED AND REPLACED LT OVERWING AFT EMERGENCY LIGHT LAMP IAW AMM TASK 33-50-10-000-801-A AND 33-50-10-400-801-A. OPS CHECK GOOD.SDR SIMA20181015002Conditioner · failedUPON DEPARTURE THE RIGHT WING FUEL INDICATION WENT TO 0. FOUND REFUEL/DEFUEL PANEL SWITCH IN "BATTERY" POSITION UPON AIRCRAFT ARRIVAL CONFIGURED NORMALLY IAW AMM 12-11-01. TROUBLESHOT IAW FIM TASK 28-41-00-810-845-A WITH NO FAULTS FOUND, REMOVED AND REPLACED FSDR SIMA201810087001Flashlight · inoperativeFORWARD CABIN FLASHLIGHT NOT WORKING. -C/A-FOUND FLASHLIGHT TO BE BAD. REPLACED FLASHLIGHT IAW AMM 33-50-16. NO FURTHER DEFECTS NOTED. FLASHLIGHT OPERATES NORMALLY NOW.SDR SIMA201810085002Flap · out of adjustMAIN SERVICE HAD VERY LOUD SQUEEL AFTER T/O FROM TOP OF DOOR. MAIN SERVICE DOOR INDICATED CLOSED ON MFD "TRANSFERRED TO NRWC 941-SGF-03683" JP678019-C/A-UPON INSP FOUND SIGNIFICANT GAP BETWEEN MAIN DOOR FAME AND FOLDING FLAP WHEN DOOR IS SHUT. PERFORMED MAIN DSDR SIMA201809042002Controller · lack of lubeCREW REPORTED PARKING BRAKE VERY DIFFICULT TO ENGAGE. LUBRICATED PARKING BRAKE CONTROL IAW AMM 32-44-10. OPS CHK GOOD.SDR SIMA201808276003Smoke Detector · false activationCARGO SMOKE INDICATION DURING FLIGHT, CARGO EXTINGUISHER DISCHARGED IAW AOM. INSPECTED THE CARGO BAY AND FOUND NO EVIDENCE OF SMOKE. REMOVED AND REPLACED THE SMOKE DETECTORS IAW AMM 26-15-01. OPS CHECKED GOOD.SDR SIMA2018080131002Light · inoperativeFOUND LT REAR EXTERNAL EMERGENCY LIGHT TO BE INOP. REPLACED LIGHT IAW AMM 33-50-10. OPS CHECK GOOD IAW AMM 33-50-00. NO FURTHER DEFECT NOTED.SDR SIMA2018072321002Control Unit · faultyINBND JAN DECLARED EMRG FOR SPOILERON FAIL IN FLIGHT. INTERROGATED CMC AND FOUND FAULT CODE GND SPLR ENG CKT FAULT AND SPBK LEVER SW/RELAY FAIL. REMOVED AND REPLACED SPOILER CONTROL UNIT IAW AMM-27-63-02. OPCK GOOD.SDR SIMA20180221004Cradle · crackedFWD CABIN FLASHLIGHT CRADLE CRACKED. REMOVED AND REPLACED FWD CABIN FLASHLIGHT CRADLE ASSEMBLY IAW AMM 33-50-16-000-801-A & 33-50-16-400-801-A OPS CHECK GOOD AT THIS TIME END.SDR SIMA20180204001Uplock · failedLOUD RHYTHIMIC BANGING NOISE FROM NOSE WHEEL AREA AFTER RETRACTING GEAR ON TAKE OFF. GEAR INDICATED UP. NOISE WENT AWAY AFTER GEAR WAS DOWN. NO RELATED NLG CMC MESSAGES. REMOVED AND REPLACED NLG UPLOCK BOX IAW AMM 32-33-07. LANDING GEAR NORMAL AND EMERGENSDR SIMA20180126005Battery · dischargedLT AND RT OVERWING EXTERNAL LIGHTS FAIL TO ILLUMINATE. REMOVED AND REPLACED NR 4 EMERGENCY POWER SUPPLY BATTERY AND CHARGER IAW AMM 33-50-04. OPS CHECK GOOD. BATTERY CHARGER ASSY P/N 11-0049 S/N 15271.SDR SIMA20180126006Light · inoperativeLT AND RT OVERWING EXTERNAL LIGHTS FAIL TO ILLUMINATE. REMOVED AND REPLACED LT AND RT OVERWING EXTERNAL LAMPS IAW AMM 33-50-10. OPS CHECK FAILED. CHARGER ASSY BATTER P/N BA5-0933-901 S/N C01638.SDR SIMA20180119003Power Supply · inoperativeDURING A CHECK, FOUND THE LEFT AND RIGHT OVERWING EMERGENCY LIGHTS INOPERATIVE. R & R THE POWER SUPPLY NR 4 IAW AMM 33-50-04. OPS CHECKED GOOD. NO DEFECTS NOTICED.SDR SIMA20171222003Power Supply · inoperativeBOTH RT AND LT OVERWING EMERGENCY LIGHTS INOPERATIVE. R & R THE NR 4 POWER SUPPLY AND BATTERY PACK IAW AMM 33-50-04-000-801-A, AND 33-50-04-400-801-A, OPS CHECKED GOOD.SDR SIMA20171222002Lamp · inoperativeSERVICE DOOR EMERGENCY LIGHT INOPERATIVE. REMOVED AND REPLACED THE LAMP IAW AMM 33-50-10-000-801-A, & 33-50-10-400-801-A. OPS CHECKED GOOD.SDR SIMA20171211005Lamp · inoperativeSERVICE DOOR EMERGENCY LT INOP-C/A-REMOVED AND REPLACED SERVICE DOOR EMERGENCY LAMP IN REFERENCE WITH EMB AMM 33-50-10-000-801-A AND 33-50-10-400-801-A. NO FURTHER DISCREPANCIES FOUND. END.SDR SIMA20171211004Battery Pack · inoperativeBOTH EXTERIOR OVERWING EMERGENCY LTS INOP-C/A-REMOVED AND REPLACED #4 EMERGENCY BATTERY AND POWER SUPPLY IAW ENVOY W/C 33-700-19 AND 33-700-17 OPS CHECK GOOD. BATTERY CHARGER ASSY P/N 11-0049 S/N 12701SDR SIMA20171210003Charger · inoperativeFOUND AFT EXTERIOR RH EMERGENCY LIGHT TO BE INOP DURING PS-1 CHECK-C/A-REMOVED AND REPLACED #4 BATTERY POWER SUPPLY IAW EMB 145 AMM 33-50-04-04. OPS CHECK GOODSDR SIMA20171110001Battery · dischargedLT AND RT AFT OVERWING EXIT LIGHTS INOP. REMOVED AND REPLACED NR 4 BATTERY AND CHARGER IAW WORKCARD 33-700-19 OPS CHECK GOOD. BATTERY CHARGER ASSY P/N 11-0049 S/N 19592.SDR SIMA20170609002Battery Pack · disconnectedEMERGENCY LIGHT POWER SUPPLY INOPERATIVE. INSPECTED THE POWER SUPPLY AND FOUND THE BATTERY TO HAVE BECOME DISSCONNECTED. CONNECTED THE BATTERY, AND OPS CHECKED GOOD. WORK DONE IAW AMM 33-50-04-400-802-A. NO FURTHER DEFECTS NOTED AT THIS TIME.SDR SIMA20170531009Engine · malfunctionedNR 2 ENGINE SPOOLED DOWN AT GATE, ENGINE OUT EICAS CAUTION MESSAGE. START STOP SELECTOR WAS IN RUN POSITION AT THAT TIME. COMPLIED WITH FIM TASK 72-00-00-810-815 , FIM TASK 72-00-00-810-809 AND PERFORMED OPERATIONAL TEST OF ENGINE AT MAXIMUM POWER IAW MM 7SDR SIMA20170530002Flashlight · inoperativeFLASHLIGHT ABOVE FA JUMPSEAT DOEN NOT WORK. REPLACED THE FLASHLIGHT.SDR SIMA20170503002Battery · dischargedRT EXTERIOR FUSELAGE FWD EMERGENCY LIGHT INOP. REMOVED AND REPLACED EMERGENCY LIGHT BATTERY AND CHARGER IAW AMM 33-50-04 OPC GOOD. LIGHT EMERGENCY P/N 30-2510-3. BATTERY CHARGER ASSY P/N 11-0049 S/N 24446.SDR SIMA20170320002Bulb · inoperativeAFT LT EXTERIOR EMERGENCY LIGHT INOPERATIVE. R & R THE BULB, OPS CHECKED GOOD IAW AMM 33-50-10SDR SIMA20170216001Thermostat · failedBLEED NR 1 OVERTEMP DURING CLIMB OUT OF 5,000FT. REMOVED AND REPLACED THE 1 ENGINE FAN AIR CONTROL THERMOSTAT IAW AMM 36-11-06. OPS CHECKED GOOD.SDR SIMA20161216002Ecu · failedFLAP LOW SPEED EICAS MSG FOLLOWED BY SPS ADVANCED MSG. WHEN FLAPS SELECTED ON APPROACH IN ICING CONDITIONS. DECLARED EMERGENCY.-C/A-DEFERRED FLAP CHANNEL 2, "M" PROCEDURE C/W.MEL 27-9 AUTH 120375DM-B MOC 607038. REMOVED AND REPLACED FLAP ELECTRONIC CONTROL UNISDR SIMA20161207007Inverter · inoperativeDURING OPERATION CHECK OF THE EMERGENCY LIGHTING SYSTEM, FOUND CEILING PANEL 253BLC AFT EMERGENCY EXIT LOCATOR SIGN INOP. AIRCRAFT WAS REMOVED FROM SERVICE FOR IMBV INSPECTION AND WILL BE RETURNED TO SERVICE AFTER IMBV INSPECTION. REMOVED AND REPLACED CEILINGSDR SIMA20161205002Light · inoperativeDURING OPERATIONAL CHECK OF THE EMERGENCY LIGHTING SYSTEM, FOUND PAX DOOR EMERGENCY LIGHT INOP. AIRCRAFT WAS REMOVED FROM SERVICE FOR IMBV INSPECTION AND WILL BE RETURNED TO SERVICE AFTER IMBV INSPECTION. REMOVED AND REPLACED PAX DOOR EMERGENCY LIGHT ASSEMBLYSDR SIMA20161128005Skin · crackedDURING IMBV INSPECTION, QA FOUND THE FUSELAGE EXTERNAL SKIN CRACKED AROUND 1 FASTENER AT FR78 LT BETWEEN STGR 5L-6L. AIRCRAFT WAS REMOVED FROM SERVICE FOR IMBV INSPECTION AND WILL BE RETURNED TO SERVICE AFTER IMBV INSPECTION. INSTALLED BUSHING ON FUSELAGE EXTESDR SIMA20161128012Skin · crackedDURING IMBV INSPECTION, QA FOUND CRACKS AROUND ONE FASTENER AT FR 77 BETWEEN STGR 3R AND 4R. AIRCRAFT WAS REMOVED FROM SERVICE FOR IMBV INSPECTION AND WILL BE RETURNED TO SERVICE AFTER IMBV INSPECTION. PERFORMED PERMANENT REPAIR BY INSTALLING A BUSHING ON FR SDR SIMA20161128013Skin · crackedDURING IMBV INSPECTION, QA FOUND CRACKS AROUND ONE FASTENER AT FR 78 BETWEEN STGR'S 5R AND 6R. AIRCRAFT WAS REMOVED FROM SERVICE FOR IMBV INSPECTION AND WILL BE RETURNED TO SERVICE AFTER IMBV INSPECTION. PERFORMED PERMANENT REPAIR BY INSTALLING A BUSHING ON RSDR SIMA20161126004Floorbeam · crackedDURING IMBV INSPECTION, QA FOUND CRACKS AROUND NUT PLATE HOLES ON LAV LT FLOORBEAM, ONE AT FR 59 AND ONE AT FR 61. AIRCRAFT WAS REMOVED FROM SERVICE FOR IMBV INSPECTION AND WILL BE RETURNED TO SERVICE AFTER IMBV INSPECTION. REPAIRED CRACKS AT NUT PLATE HOLES
Back to N941LT