N946SW
Service difficulty reports · 218
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N946SW' AND registry_match = 'registration' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N946SW' AND registry_match = 'registration' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWIA201231058Connector · out of adjustFORWARD SECTION OF FLOOR LEVEL EMERGENCY LIGHTS OUT. (FLT 5599) ADJUSTED FLOOR EMERGENCY CENTER LIGHT STRIP CONNECTION.SDR SWIA201231010Charger · failedRIGHT WING EMERGENCY EXIT LOWER FORWARD LIGHTED SIGN IS INOPERATIVE. (FLT 6495) REPLACED NR 3 CHARGER ASSEMBLY IN REFERENCE TO AMM.SDR SWIA201230967Connector · dirtyEMERGENCY LIGHT STRIP ON FLOOR IS OUT BETWEEN ROWS 6-10 AND UNDERNEATH RIGHT OVERWING EXIT. (FLT 5561) CLEANED CONNECTION ON FLOOR LIGHTING STRIP AT SEAT 6-9 C/D.SDR SWIA201230001Light · inoperativeNR 2 OVERHEAD EMERGENCY LIGHT IS OUT. (FLT 6255) RELAMPED EMERGENCY LIGHT.SDR SWIA201229575Priority Valve · failedNOSE DOOR OPEN, GEAR DISAGREE. (FLT 5486) REPLACED NLG PRIORITY VALVE, PN OFF 4622, SN OFF 876.SDR SWIA201229483Light · inoperativeNR 2 OVERHEAD EMERGENCY LIGHT IS OUT. (FLT 6402) RELAMPED EMERGENCY LIGHT.SDR SWIA201229120Hydraulic System · contaminatedUPON LANDING GEAR RETRACTION FROM FAT RECIEVED GEAR DISAGREE. (FLT 5439) BLEED AIR FROM NR 3 HYD SYSTEM AND SERVICED TO PROPER LEVEL.SDR SWIA201128953Light · inoperative3RD OVERHEAD EMERGENCY LIGHT INOPERATIVE. (FLT 5338) RELAMPED EMERGENCY LIGHT.SDR SWIA201128789Light · inoperativeNR 2 FLOOD EMERGENCY CEILING LIGHT INOPERATIVE. (FLT 6380) RELAMPED EMERGENCY LIGHT.SDR SWIA201128517Light · inoperativeNR 3 OVERHEAD EMERGENCY LIGHT IS OUT. (FLT 5362) RELAMPED EMERGENCY LIGHT.SDR SWIA201128120Windshield · failedCAPTAIN'S WINDSHIELD BEGAN ARCING AND THEN SHATTERED. (FLT 6496) REPLACED CAPTAIN'S WINDSHIELD.SDR SWIA201127953Light · inoperativeNR 2 OVERHEAD EMERGENCY LIGHT IS INOPERATIVE. (FLT 5407) RELAMPED EMERGENCY LIGHT.SDR SWIA201127425Light · inoperativeNR 3 CEILING EMERGENCY LIGHT IS OUT. (FLT 6442) RELAMPED EMERGENCY LIGHT.SDR SWIA201127390Light · inoperativeNR 3 AND NR 4 OVERHEAD EMERGENCY LIGHTS ARE OUT. (FLT 6330) RELAMPED EMERGENCY LIGHTS.SDR SWIA201126664Button · dirtyMAIN CABIN DOOR WILL NOT OPEN. (FLT 5558) MCD POWER ASSIST BUTTON STUCK ON. CLEANED MCD ASSIST BUTTON.SDR SWIA201126183Skin · damagedCARGO DOOR CUTOUT IS DENTED AT AFT LOWER CORNER EXTERIOR SKIN. (C-CHECK) REPAIRED PER SRM.SDR SWIA201126127Floorbeam · cracked(C-CHECK) FS 280 FLOORBEAM CRACKED AT UPPER RADIUS. REPAIRED PER REO.SDR SWIA201126116Bulkhead · cracked(C-CHECK) FS 621 BULKHEAD WEB CRACKED ABOVE CARGO DOOR TRACK. REPAIRED PER REO.SDR SWIA201024034Light · inoperativeCENTER CEILING CABIN LIGHT INOP AT ROW 13. (FLT 5814) RELAMPED CEILING LIGHT.SDR SWIA200923346Door · obstructedMAIN CABIN DOOR WILL NOT OPEN. (FLT 5838) REMOVED ICE BUILDUP.SDR SWIA200922593Connector · loosePASSENGER DOOR EMERGENCY EXIT LIGHT SIGN INOP. (FLT 6151) RE-SECURED CONNECTION.SDR SWIA200922553Light · inoperativeRIGHT WING CENTER EMERGENCY EXIT LIGHT INOP. (FLT 6611) RELAMPED EMERGENCY LIGHT.SDR SWIA200922266Case · crackedLEFT ENGINE LOW PRESSURE TURBINE CASE CRACKED BEYOND LIMITS. (C-CHECK) REPLACED ENGINE.SDR SWIA200922252Structure · crackedCRACK AT FS 559. (C CHECK) REPAIRED PER REO.SDR SWIA200922250Fitting · crackedLINTEL FITTING ZONE 200 CRACKED. (C CHECK) REPAIRED PER REO.SDR SWIA200921922Control System · fodON ROTATION ELEVATOR HESITATED AND DID NOT GIVE FULL AUTHORITY MOMENTARILY. (FLT 6655) REMOVED FOD FROM AFT EQUIPMENT BAY.SDR SWIA200921747Sign · inoperativeEXIT SIGN AT THE FOOT OF THE MAIN DOOR INOP. (FLT 6605) RELAMPED EXIT SIGN.SDR SWIA200921202Window · crackedFLT 6561 - LEFT WINDOW SHATTERED IN FLIGHT. REPLACED WINDOW, PN OFF 601R33033-11 SN OFF 02329H2005.SDR SWIA200921091Lamp · burned outFLT 6660 - ONE OF THE FIVE BULBS ON THE SERVICE DOOR EXIT SIGN INOP. RELAMPED.SDR SWIA200920828Unknown · smokeFLT 6019 - AFTER TAKEOFF, FLIGHT ATTENDANT REPORTED SMOKE IN CABIN. REPLACED WATER SEPARATOR FILTERS ON BOTH ACM'S. ACCOMPLISHED COMPRESSOR WASH AND RUNS ON BOTH ENGINES.SDR SWIA200820535Inverter · dischargedFLT 6704 - EMERGENCY LIGHTS INOP IN AFT CABIN. REPLACED NR 4 INVERTER.SDR SWIA200820301Target · out of adjustAFTER TAKE OFF NOSE GEAR WOULD NOT RETRACT. (FLT 6491)ADJUSTED CENTERING TARGET ON NOSE STRUT.SDR SWIA200820279Bracket · bentGEAR DISAGREE MESSAGE, NOSE GEAR DID NOT RETRACT, MAIN GEAR RETRACTED (FLT 5899). REPLACED BENT NOSE CENTERING PROXIMITY SENSOR BRACKET.SDR SWIA200819967Door · dirtySERVICE DOOR IS HARD TO OPEN FROM OUTSIDE. FLIGHT 6490. INSPECTED, CLEANED AND LUBED SERVICE DOOR AND SEAL IAW AMM 52-41-00. OPS CHECK GOOD.
SDR SWIA200819841Windshield · crackedFLT 6146 - RIGHT SIDE WINDSHIELD INNER PLY CRACKED WHILE PARKED AT GATE. REPLACED RIGHT WINDOW IAW AMM 56-12-01, P/N NP-139322-2, S/N OFF 02346H2842.SDR SWIA200819499Relay · faultyFLT 6399 - EMERGENCY LIGHTS ARE ON DURING FLIGHT. INSTALLED A/C ESSENTIAL BUSS SENSE RELAY K1XD AS REQUIRED.SDR SWIA200819247Coalescer Bag · odorFLT 5932 - RECEIVED A SMOKE TOILET CAUTION MESSAGE. REPLACED LEFT AND RIGHT COALESCER BAGS IAW 21-51-13 CMM. PERFORMED ENGINE RUNS IAW 71-00-00. NO DEFECTS NOTED.
SDR SWIA200718982Duct · contaminatedFLT 5870 - "SMOKE TOILET" MESSAGE ILLUMINATED AFTER TAKEOFF. INSPECTED AIR CONDITIONING AND LAV SMOKE DETECTION SYSTEM AND REMOVED RESIDUAL CONTAMINATION IN DUCTING. NO FURTHER DEFECTS NOTED AT THIS TIME.SDR SWIA200718964Acm · failedFLT 6389 - AFTER TAKEOFF, SMOKE TOILET CAUTION MESSAGE APPEARED. RETURNED TO FIELD. REPLACED NR 2 ACM PER CRJ 200 21-51-1A.SDR SWIA200719304Bearing · corrodedRIGHT ENGINE AFT THRUST FITTING BEARING IS CORRODED, FOUND AT C-CHECK. REPLACED ENGINE AFT THRUST FITTING BEARING PER CRJ200 AMM 71-22-01-400-801.
SDR SWIA200719303Bearing · corrodedFOUND AT C-CHECK, LEFT ENGINE AFT THRUST FITTING BEARING IS CORRODED. REPLACED LEFT ENGINE AFT THRUST FITTING BEARING PER CRJ200 AMM 71-22-01-400-801.
SDR SWIA200719302Floorbeam · crackedFS 280 AND LBL9 LOWER SUPPORT ANGLE IS CRACKED, FOUND AT C-CHECK. INSTALLED REPAIR PARTS AT LBL9.0 AND FS 280 LOWER SUPPORT ANGLE IAW CRJ200 REO 601R-53-11-171.SDR SWIA200719301Bulkhead · crackedCRACK ON COPILOTS BULKHEAD WEB AT STA 280.00 AND WL73.00 RBL11.00, FOUND AT C-CHECK. INSTALLED REPAIR PARTS IAW CRJ200 REO 601R-53-11-1292, DATED 12/03/07.
SDR SWIA200718739Light · inoperativeFLT 1902 - FOUND FORWARD FLOOR EMERGENCY LIGHTING STRIP IS INOP. REPLACED FORWARD FLOOR LIGHT STRIP IAW AMM 33-50-00.SDR SWIA200617017Doubler · crackedDOUBLER CRACKED BETWEEN STR 9 AND 13, DISCOVERED DURING C-CHECK INSPECTION. INSTALLED NEW DOUBLER FOR RT 640 FRAME PER SRM 51-42-06 PG 1-17 AND SRM 51-42-21 PG 17 STEP 9 PN 601R36002-4/5B.SDR SWIA200617016Doubler · crackedDOUBLER CRACKED BETWEEN STR 9 AND 13, DISCOVERED DURING C-CHECK INSPECTION. INSTALLED NEW FRAME DOUBLER PN 601R36002-3SB AT LT STA 640 BETWEEN STR 9 AND 12 IAW CRJ200 SRM 51-42-06 PG 1-17 AND 51-42-21 PG 1-9.SDR SWIA200617015Beam · crackedRIGHT SIDE ENGINE BEAM CRACKED AT APPROX FS 625.30 RBL 36.20 AND WL 111.09, DISCOVERED DURING C-CHECK INSPECTION. INSTALLED REPAIR PARTS ON RT ENGINE BEAM PER REO NR 601R-53-61-358.SDR SWIA200617014Beam · crackedLEFT SIDE ENGINE BEAM CRACKED AT APPROX FS 625.30 LBL 36.20 AND WL 111.09, DISCOVERED DURING C-CHECK INSPECTION. INSTALLED REPAIR PARTS AS PER CRJ200 REO 601R-53-61-358 AND RII 51-401.SDR SWIA200617013Handle · crackedPAX DOOR OUTER HANDLE CRACKED, DISCOVERED DURING C-CHECK INSPECTION. INSTALLED PAX DOOR OUTSIDE HANDLE (SERVICEABLE) PER CRJ 200 AMM SUBTASK 52-11-03-420-003 THROUGH ITEM 21.SDR SWIA200617012Intercostal · crackedFS 484 RBL 36 INTERCOSTAL CRACKED, DISCOVERED DURING C-CHECK INSPECTION. INSTALLED NEWLY FABRICATED ANGLE AS PER CRJ200 SRM 51-42-21 PG 13-18.