SDR RRXQA002634Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES TO THE FLOOR PANEL AT STA 1000 - 1240 ROW 4, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVEDMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002649Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES IN PLANK CHANNEL ON THE NR 4 FLOOR PANEL AT STA 1000 - 1320, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-0May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002648Floorboard · damagedDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES TO THE NR 3 FLOOR PANEL AT STA 320 - 660, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WIMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002647Floorboard · damagedDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED AND ELONGATED HOLES TO THE FLOOR PLANK AT STA 800 TO 1000, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002646Floorbeam · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES TO THE FLOORBEAM TO PLANK ATTACH POINT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVED 8110-May 16, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002645Floorboard · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED ATTACH POINT HOLES ON THE FLOORBEAM AT NR 1 FLOOR PLANK FS 420 TO 600, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED REPAIR IAW EO NR 0May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002644Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED AND LONGATED HOLES TO THE NR 2 FLOOR PANEL AT STA 1000 - 1240, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NRMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002643Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES TO THE NR 2 FLOOR PANEL AT STA 320 - 620, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WIMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002642Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES TO THE FLOOR PANEL AT STA 1000 - 1320, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002640Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES TO THE FLOOR PANEL AT STA 230 - 500, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002638Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND LONGATED HOLES TO THE FLOOR PANEL AT STA 1000 - 1460 ROW 9 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-0May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002637Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES TO THE FLOOR PANEL AT STA 600 - 860, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002636Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES TO THE FLOOR PANEL AT STA 1000 - 1400, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002633Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES TO THE FLOOR PANEL NR 4 AT STA 235 - 320, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WIMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002632Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES AND ELONGATED HOLES IN THE FLOOR PANEL AT STA 660 - 800, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002631Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES ON THE FLOOR PANEL AT STA 860 - 1000 ROW 9, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002494Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES TO THE FLOOR PLANK AT STA 660 - 860, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVEMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002493Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES TO THE FLOOR PLANK AT STA 1240 - 1460 ROW 6, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITHMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002492Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES TO THE NR 3 FLOOR PLANK AT STA 225 - 320, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002491Floorboard · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE AND ELONGATED ATTACH FASTENER HOLES TO THE FLOOR PLANK TO FLOORBEAM ON NR 2 FLOOR PANEL AT STA 225 - 320, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002489Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOOR PLANKS AT FS 860 - 1000, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVEMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002488Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES TO THE FLOOR PLANK AT STA 600 - 860, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVEMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002487Floorboard · gougedDURING A MAINTENANCE VISIT FOUND DENTS AND GOUGES TO THE NR 2 FLOOR PLANK CHANNEL AT STA 1000 - 1240, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH AMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002486Floorboard · gougedDURING A MAINTENANCE VISIT FOUND DENTS AND GOUGES TO THE CENTER CHANNEL ON THE NR 2 FLOOR PLANK AT STA 800 - 1000 ROW 5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002484Floorboard · damagedDURING A MAINTENANCE VISIT FOUND ELONGATED HOLES ON THE FLOOR PANEL TO FLOORBEAM ATTACH FASTENER AT STA 1240 - 1460 ROW 12, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002483Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES TO THE FLOOR PLANK AT STA 660 - 1000 ROW 7, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002482Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES TO THE FLOOR PLANK AT STA 660 - 1000 ROW 6 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WIMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002478Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES TO THE NR 4 FLOOR PANEL AT STA 1000 - 1460 ROW 7, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED REPAIR IAW EO NR 00-047May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002477Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES TO THE NR 4 FLOOR PANEL AT STA 1000 - 1240 ROW 1 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002476Floorboard · damagedDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED AND ELONGATED HOLES TO THE FLOOR PANEL AT STA 320 - 600, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-04May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002458Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE FLOOR PLANK AT STA 235 - 660, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED REPAIR IAW EO NR 00-047 WITH APPROVEDMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002457Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE FLOOR PLANK AT STA 235 - 230, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVEDMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002456Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES IN THE FLOOR PLANK AT STA 225 - 320, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVEDMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002455Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE FLOOR PLANK AT STA 520 - 580, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVEDMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002454Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE FLOOR PANEL AT STA 225 - 420, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVEDMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002453Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES TO THE FLOOR PANEL AT STA 800 - 1000, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002451Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND SEVERAL MISDRILLED HOLES TO THE FLOOR PLANK AT FS 225, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVED 8110-3May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002449Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED HOLES ON THE FLOOR PLANK AT STA 320 - 600 LT ROW 2, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002447Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES IN THE FLOOR PANEL AT STA 320 - 660, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002445Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES TO THE FLOOR PANEL AT STA 660 - 860, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED AND INSTALLED REPAIR IAW EO NR 00-047 WITH APMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002444Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES IN THE UPPER AND LOWER SIDE AT STA 660 - 880 LT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002443Floorboard · crackedDURING A MAINTENANCE VISIT FOUND A CRACKED FLOOR PANEL ON UNDERSIDE AT STA 225 - 320, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVED 8110-3 DMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002442Floorboard · damagedDURING A MAINTENANCE VISIT FOUND LONGATED HOLES TO THE FLOOR PANEL AT STA 225 - 320, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVED 8110-3 DAMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002441Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES IN THE CABIN FLOOR PANEL AT STA 255 - 660, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WITH APPROVED 8May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002440Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED AND ELONGATED HOLES TO THE CABIN FLOOR PANEL AT STA 215 - 320, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW EO NR 00-047 WMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002367Floorboard · tool damageDURING A MAINTENANCE VISIT FOUND TOOLING MARKS GOUGED ON FLOOR PANEL AT STA 660 - 860, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. RECEIVED REPAIR AND INSTALLED IAW DC-8 SRM 53-2-0 AND EO NR 00-047 WMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002360Floorbeam · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS DRILLED HOLES IN THE FLOORBEAM AT STA 400 CUSP TO CUSP, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED DOUBLER IAW EO NR 00-047 WITH APMay 16, 2000 · N995CF · Doug DC862 · Fuselage Main, Floor BeamSDR RRXA002353Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND NUMEROUS MISDRILLED AND ELONGATED HOLES IN THE CABIN FLOOR PLANK AT STA 1000 TO 1320 ROW 5 RT, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. WELDED HOLES AND BLENDED IAMay 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002296Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND MISDRILLED HOLES TO THE FLOOR PANEL AT STA 1000 - 1460 ROW 3, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. PLUGGED DISCREPANT HOLES IAW EO NR 00-047 WITH APPROVED 8110May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor PanelSDR RRXA002295Floorboard · misdrilledDURING A MAINTENANCE VISIT FOUND A CRACK TO THE FLOOR PANEL AT STA 1000 - 1240 ROW 12, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8. STOP DRILLED CRACK IAW EO NR 00-047 WITH APPROVED 8110-3 DATED 4-2-0May 16, 2000 · N995CF · Doug DC862 · Fuselage Floor Panel
Back to N995CF